Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹13.7 L+₹1.4 L (11.2%)Rejected-Finance | L2 | Rejected-Finance Second Lowest amount quoted | |
| 3 | L3₹14.6 L+₹2.3 L (18.4%)Rejected-Finance MAIN ROAD RANJHI BAZHAR JABALPUR MP PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | L3 | Rejected-Finance Third Lowest amount quoted | |
| 4 | L4₹14.7 L+₹2.4 L (19.5%)Rejected-Finance | L4 | Rejected-Finance Fourth Lowest amount quoted | |
| 5 | L5₹15.4 L+₹3.1 L (25.5%)Rejected-Finance 01 PATHWALIYA GONDA GONDA GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | L5 | Rejected-Finance Fifth Lowest amount quoted |
Tender Value
₹15.6 L
EMD Value
₹31,200
Closing Date
3 Jul 2020, 6:00 pmClosed
Shri B M Verma, IDSE, EE(SG)
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2020_MES_351892_1
8258/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Garrison Engineer (East) Jabalpur
E b(i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹31,200
Yes
14 Aug 2020
11 Jun 2020
6 Jul 2020
11 Jun 2020
3 Jul 2020
26 Jun 2020
11 Jun 2020 - 25 Jun 2020
Amount
M&L for point wiring for one ceiling/exhaust fan point controlled by one switch and regulator with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm (FRLS), with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm (FRLS) stranded for earth continuity wire, to be drawn in and including, PVC medium grade conduit not less then 20 mm dia with MS sheet metal sunken switch/Terminal box 1.2 mm thick and hylam switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface all as directed and specified Make of cable - FINOLEX / PLAZA / HAVELLS/POLYCAB & Make of PVC conduit & conduit accessories - PLAZA / FINOLEX/ KALINGA. Note : (i) Making good to match with the adjoining surface shall be included in the quoted rate. (ii) Rate shall be included for Cutting/chases of wall/floor/ceiling
S&F Switch piano flush type single pole one way 5 amps. Make : Havells/C&S/Anchor
S&F Ceiling rose, surface bakelite 65x50 mm three terminal complete all as specified Make : Havells/C&S/Anchor
M&L for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm (FRLS), earth continuity conductor of size 2.5 Sqmm (FRLS) to be drawn through in and including non metallic PVC conduit medium grade 25 mm dia with fittings (ISI marked) fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 4 sqmm and one wire of 2.5 sqmm & PVC conduit shall be measured as one unit.
M&L for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6 Sqmm (FRLS), earth continuity conductor of size 4 Sqmm (FRLS) to be drawn through in and including non metallic PVC conduit medium grade 25 mm dia with fittings (ISI marked) fixed on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i)Two wires of 6 sqmm and one wire of 4 sqmm & PVC conduit shall be measured as one unit.
Supply and fixing Exhaust Fans (Steel body) AC single phase 230/240 Volt of size 300 mm sweep with Louvre shutter including regulator and accessories like nuts, bolts for fixing to walls, trusses, sheets & cutting holes if required and making good with existing surface etc. complete all as specified and directed. Make : Havells/Crompton/Bajaj. Note : Exhaust fans shall be ISI marked..
Supply and fixing Exhaust Fans (Steel body) AC single phase 230/240 Volt of size 380/400 mm sweep with Louvre shutter including regulator and accessories like nuts, bolts for fixing to walls, trusses, sheets & cutting holes if required and making good with existing surface etc. complete all as specified and directed. Make : Havells/Crompton/Bajaj. Note : Exhaust fans shall be ISI marked..
M&L for point wiring for one 3 pin 15 Amps socket outlet point on independent board with PVC insulated unsheathed stranded copper conductor cable of size 2.5 Sq mm (FRLS), with PVC insulated unsheathed stranded copper conductor cable of size 2.5 Sq mm (FRLS) stranded for earth continuity wire, to be drawn in and including, PVC medium grade conduit not less then 20 mm dia with MS sheet metal sunken switch/Terminal box 1.2 mm thick and hylam switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface all as directed and specified Make of cable - FINOLEX / PLAZA / HAVELLS/POLYCAB & Make of PVC conduit & conduit accessories - PLAZA / FINOLEX/ KALINGA. Note : (i) Making good to match with the adjoining surface shall be included in the quoted rate. (ii) Rate shall be included for Cutting/chases of wall/floor/ceiling
S&F earth enclosure with 2 pin earth plug socket complete with MCB SP 20/25 Amp, flush mounting type Make - LEGRAND/ABB/L&T
S&F MCB DB made of sheet steel , powder painted with nuetral bus bar 200 A, neutral link, earth bar and Din rail , 230 Volts SPN with 12 ways Double door IP-43-IK09 protection grade, Make -L&T/LEGRAND/ABB
S&F MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32Amps complete all as specified Make -L&T/LEGRAND/ABB
S&F MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating complete all as specified Make -L&T/LEGRAND/ABB
S&F MCB DB made of sheet steel , powder painted with neutral bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 ways Double door, Make -L&T/LEGRAND/ABB
S&F MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps complete all as specified Make -L&T/LEGRAND/ABB
S&F XLPE insulated armoured and PVC sheathed "heavy duty" electric cable with aluminium conductor 1100 volts grade laid in trenches, passing through pipes /ducts including testing complete of cross sectional area and size 4 Core, 25 sqmm :- Note:- Rate is inclusive of cable gland & cable lugs. Make : Havells/GLOSTER/Poly Cab
Excavation in trenches for laying of cables ,poles and stay in any type of soil not exceeding 1.5 mtr wide and n. exc 1.50 mtr deep and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc. 25cm complete all as specified and directed by Engr-in-Charge.
Removing excavated soil n.exc 50 mtr and depositing where directed at a level n. exe 1.5mtr above the starting point complete all as specified and directed.
S&F 50mm bore GI steel tubing "light grade" for cable protection passing under road /floor or for fixing to poles complete all as specified and directed Make - JINDAL/ ZENITH/ TATA/ PRAKASH
M&L unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified. Note : Measurement shall be done after puning down of sand.
M&L Brick covering with width equal to length of bricks as mechanical protection to cable with well burnt sub class `B` old size bricks laid dry and flat complete all as specified and as directed.
RELIABLE PRODUCTS AND SERVICES
ELCON
GAUTAM ELECTRIC WORKS
S K TRADERS
M/S BHATIA CONSTRUCTIONS
RAVI TEJ BUILDERS
ANAMIKA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .