| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC CAMP INS CHILKA CHHATRAGARH PO NB CHILKA ODISHA 752037 | CHILKA | KHORDHA | ODISHA | 752037 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.4 L+₹60,302.90 (3.81%)Rejected-Finance AT AMRITPUR PO NB CHILKA VIA BALUGAON DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹16.5 L+₹66,234.30 (4.18%)Rejected-Finance AT DUNGAMAL NH 5 PO INS CHILKA VIA BALUGAON DIST KHORDHA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹16.6 L+₹77,418.40 (4.89%)Rejected-Finance AT DUNGAMAL NH 5 PO INS CHILKA DISTT KHORDHA ODISHA 752030 | KHORDHA | ODISHA | 752030 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹17.8 L+₹2.0 L (12.6%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
22 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Chilka
Garrison Engineer Chilka PO INS Chilka Distt Khordha Odisha 752037
REPAIRS TO ROOF, CEILING, WALL, STAIRCASE, RAILING AND CERTAIN CONNECTED WORKS TO CERTAIN BUILDINGS AT INS CHILKA UNDER GE CHILKA
2022_MES_553855_1
GE/CHL/8826 OF 2022-23
Open Tender
Civil Works
Item Rate
182 days
Garrison Engineer Chilka
MES Enlisted Contractor of class E category a i
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Chilka
₹30,000
Yes
15 Dec 2022
23 Sept 2022
29 Oct 2022
23 Sept 2022
22 Oct 2022
8 Oct 2022
23 Sept 2022 - 30 Sept 2022
Amount
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not packing) removing of serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for coloured non skid ceramic tiles not less than 7 to 8 mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M&L for coloured non skid ceramic tiles not less than 7 to 8 mm thick, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M&L for coloured glazed ceramic tiles in vertical surface 375mmx250mmx 6 to 7mm / 450mmx300x6to7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
M&L for coloured glazed ceramic tiles in vertical surface 300mmx200mmx 6 to 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
Taking down existing waterproofing treatment complete of any description from brick or RCC wall and RCC slab by scrapping including removal of rubbish where directed to a distance not exceeding 100M complete all as specified and as directed.
M&l water proofing treatment to roof as per per manufacturer's instructions with the following specification:-. (a) 15 mm thick plastering in cement mortar 1:4 mixed with and including water proofing compound @3% by weight of cement including preperation of roof surfaces. (b) Applying evenly a coat of bitumineous primer @ 0.5 litre per Sqm (c) Applying evenly a coat of hot blow bitumen 85/25 grade @ 1.2 Kg per Sqm (d) Applying APP based polymeric membrane minimum 3 mm thick and minimum weighing 3kg/sqm laid on primed surface by LPG forced torch application with a side & end overlaps of minimum 100 mm. (e) Applying evenly a coat of hot blown bitumen 85/ 25 grade @ 1.2 Kg per Sqm over water proofing membrane (f) Applying a coat of bituminous based aluminium primer @ 100 gm/Sqm on top including sealing all joints by thermo fusion complete all as per manufacturer's instructions
Demolition of cement concrete un reinforced of any description and in any position above roof slab as in padding, coping etc including removal of old materials to a distance not exceeding 100 m complete complete all as specified and as directed.
M&L 25 mm thick cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate mixed water proofing compound as in roof padding to receive the toping layers complete all as specified and directed .
M&L cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed .
Taking down cement plaster on brick or stone wall or on concrete surfaces including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
M&L for 15 mm thick rendering (in two layers) on brick work or concrete sufaces, Ist layer 10 mm thick in cement mortar 1:4 and 2nd layer in cement mortar 1:4 mixed with WPC @ 3% by weight of cement , surface finished even and fair complete all as specified and as directed. Note :- Water proofing compound shall be measured and paid separately.
Supply only water proofing compound complete all as specified and as directed.
M&L 15 mm thick rendering on brickwork or concrete surfaces of wall in cement mortar 1:6, surface finished even and fair complete all as specified and as directed.
M&L 5 mm thick rendering in cement mortar 1:3 on ceiling , surface finished even and fair complete all as specified and as directed.
M&L for applying two coats of weather proof acrylic emulsion (Anti dust) paint exterior grade (100% acrylic) over a coat of alkali guard anti efflorescence primer as per manufacturer's instruction including preparation of new external surfaces of walls of any description over 10 cm width or girth etc on column/ pillars, RCC chhajja and facia etc complete all as specified and as directed.
M&L for applying two coats of oil bound distemper over a coat of alkali resistant primer including preperation of newly plastered surfaces of wall complete all as specified and as directed.
M&L applying three coat of white wash on wall including preparation of newly plastered surfaces of wall complete all as specified and as directed.
M&L applying three coat of white wash on ceiling including preparation of newly plastered surfaces of ceiling complete all as specified and as directed.
Demolition of brick or stone masonary work built in cement mortar including all quoins ,arches,pillars etc complete all as specified and as directed.
M&L for brick work with fly ash bricks, straight or curved on plain exceeding 6m means radius built in cement mortar 1:6 complete all as specified and as directed.
M&L brickwork with fly ash bricks, straight or curved on plan to any radius as in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for re-fixing or removal from site complete all as specified and as directed.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for re-fixing or removal from site complete all as specified and as directed.
Taking up or down 25 mm bore steel tubing and connections, including cleaning for re-fixing or removal from site complete all as specified and as directed.
Fixing only 15 mm bore old GI steel tubing and connections in new or old position (Walls, ceiling, floors etc) complete all as specified & directed.
Fixing only 20 mm bore old GI steel tubing and connections in new or old position (Walls, ceiling, floors etc) complete all as specified & directed.
Fixing only 25 mm bore old GI steel tubing and connections in new or old position (Walls, ceiling, floors etc) complete all as specified & directed.
S&F 15 mm bore galvanised iron tubes, 'medium grade' with all fittings such as bends, elbow, rducers etc and fixed complete to walls and ceilings or laid in floor complete all as specified and as directed.
S&F 20 mm bore galvanised iron tubes, 'medium grade' with all fittings such as bends, elbow, rducers etc and fixed complete to walls and ceilings or laid in floor complete all as specified and as directed.
S&F 25 mm bore galvanised iron tubes, 'medium grade' with all fittings such as bends, elbow, rducers etc and fixed complete to walls and ceilings or laid in floor complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc, including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed.
S&F 75 mm bore PVC (SWR) soil, waste and vent pipes single socketed in any length with adhesive joints, fixed to walls complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) soil, waste and vent pipes single socketed in any length with adhesive joints, fixed to walls complete all as specified and as directed.
S&F 75mm bore PVC (SWR) junction single, (single T) equal or unequal complete all as specified and as directed.
S&F 110mm bore PVC (SWR) junction single, (single T) equal or unequal complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) bend any radius complete all as specified and as directed.
S&F in repair 50 mm bore Low density polyethylene pipe(LDPE) of pressure rating 6kgf/cm2 as in waste pipe to wash hand Basin/Kitchen sink /urinal complete all as specified and as directed.
S&F Stack clamps for 110 mm bore pipe made out of flat iron 50mmx 5 mm and 16mm dia round iron stays including bolts and nuts and securing ends of stays to wall or roof complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
M&L for framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; ramed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe 290.Gde-E-165 complete all as specified and as directed .
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed.
M&L reinforced cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, shelves and the like complete all as specified and as directed.
M&L reinforced cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in chajjas complete all as specified and as directed.
Use and waste of formwork to beam ,slab,chajjas and similar items including edges, rough finished surface of concrete complete all as specified and as directed.
M&L Mild steel TMT bar 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for column hooking end and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed.
Dismantling of wall and ceiling board (fibre, pulp) insulation etc any thickness including cover fillets complete all as specified and as directed.
S&F GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27 mm fixed to sorrounding wall using nylon sleeves and screws at 450mm center to center/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm center to center with GI cleat and steel expansion fasteners with including ceiling section(n.exc 1.2m length)of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to intermediate channel at 457mm center to center of grid size 605mm x 605 mm complete all as specified and as directed.
M&L for 12mm thick gypsum board in ceiling fixed with screws as per manufacutrer's instructions complete all as specified and directed
M&L applying two coat of oil bound distemper on ceiling including one coat of primer incluidng preperation of surfaces complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting any gauge , thickness , including Nainital or similar pattern roof covering complete all as specified and directed.
S&F pre -painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall,fixed with self tapping screw complete all as specified and as directed.
S&F pre -painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and as directed.
Disconnecting existing water tank of capacity exceeding 250 litre and not exceeding 500 litre, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and re-fixing in position (Cleaning repairing, etc. measured separately) complete all as specified and as directed.
S & F in repair vitreous china squatting pan of Orissa pattern long pan size 580x440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including lime concrete bedding and necessary connection complete all as specified and as directed
S&F in repair vitreous china wash down water closet pan (Pedestal pattern) ,white including fixing bolts (excluding flushing cistern & Pipe) including necessary connection to trap and flushing pipe complete all as specified and as directed.
S&F in repair 10 litre capacity PVC valveless, syphonic action type, low level flushing cistern ,white. with inlet,ball valve, float and handle including brackets complete all as specified and as directed.
Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&l water proofing treatment to sunken floors as per per manufacturer's instructions with the following specification:-. (a) 15 mm thick plastering in cement mortar 1:3 mixed with and including water proofing compound @3% by weight of cement. (b) Applying evenly a coat of bitumineous primer @ 0.5 litre per Sqm (c) Applying evenly a coat of hot blow bitumen 85/25 grade @ 1.2 Kg per Sqm (d) Applying APP based polymeric membrane minimum 3 mm thick and minimum weighing 3kg/sqm laid on primed surface by LPG forced torch application with a side & end overlaps of minimum 100 mm. (e) Applying evenly a coat of hot blown bitumen 85/ 25 grade @ 1.2 Kg per Sqm over water proofing membrane (f) Testing for water tightness by water ponding at least 72 hours.
M&L for PCC 1:5:10 type E-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
M&L 50mm thick cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate mixed with water proofing compound @3% by weight of cement as in sunken floor, surface finished even and fair without using extra cement complete all as specified and as directed. Note :- WPC shall be measured and paid separately under respactive item.
Fixing only in repair exisitng water closet Vitreous China, semi-pedestal pattern (Anglo-Indian type) including white colour seat cover and connection to drain and to flush pipe & mild steel chromium plated or aluminised hinging device etc (excluding flushing cistern and flush pipe) complete all as specified and as directed.
M&L for vitrified ceramic tiles 9 to10 mm thick (square / rectangular) polished of approved shade, area of each tiles not exceeding 0.36 Sqm, in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match (light shade) in and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
S&F 0.80mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with L- type or J-type cranked hook bolts as in roofs, walls etc with grade of zinc coating 275 complete all as specified and as directed
S&F 2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with L- type or J-type cranked hook bolts as in roofs, wall etc. complete all as specified and as directed
M&L for removing of small plant/roots and other foreign materials from roof ,chajja etc and removing the same to a distance of 50 m and making good in cement mortar 1:3 or in cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as required on ground to the building upto 13 m height from ground level complete all as specified and as directed.
S&F in repair chromium plated fancy type hand faucet with hose & hook for EWC including all necessary fitting complete all as specified. Make :- Prayag Cat No 452 or equivalent as approved.
S&F in repair vitreous china urinal bowl flat back, size of 465mm X 355 mm X 265mm white( minimum) with grating and union and waste coupling including fixing plugs, beading urinal against wall in cement mortar 1:2 securing urinals to plugs including 60mm long brass screws, pointing around urinal back in cement complete all as specified and as directed.
S&F in repair PVC connections 15mm size with PTMT nuts and washers of length 600mm complete all as specified and as directed.
S&F in repair 40 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F in repair 15mm bore dia, Bib taps chromium plated , fancy type screwed down for iron pipe and fixed complete all as specified and directed. .
S&F in repair 75 mm diameter of outlet PVC (SWR) floor trap with grating including jointing with solvent cement complete all as specified and as directed.
S&F in repair 0.71 mm thick plain aluminium sheeting Alloy 31000 H4 in stepped flashing (measured as the minimum rectangle from which the places can be cut) complete all as specified and as directed.
M&L 25mm thick pre-formed filler (bituminous pad) for crumple /expansion Joints with joint sealing compound Grade A (normal)complete all as specified and as directed.
D RAVICHANDRAN
RCB CONSTRUCTION
UDAYA BHANU NAYAK
M/S JAGANNATH SASMAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .