Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹37,776.92Qualified Make: zebronic
Model: Zebronics 1KVC UPS WITH 45 MIN BACKUP(LB1000XL) EP 16 FIRST FLOOR IMAM UD DIN SHOPPING COMPLEX HYDERPORA BYEPASS SRINAGAR SRINAGAR JAMMU KASHMIR 190014 | BUDGAM | JAMMU AND KASHMIR | 190014 | Make: zebronic
Model: Zebronics 1KVC UPS WITH 45 MIN BACKUP(LB1000XL) | ₹37,776.92 | L1 | Qualified |
| 2 | Not yet disclosed by govt. Qualified Make: PARADYNE
Model: PARADYNE 1 KVA LI UPS | Make: PARADYNE
Model: PARADYNE 1 KVA LI UPS | - | - | Qualified |
| 3 | Not yet disclosed by govt. Qualified Make: PARADYNE
Model: PARADYNE 1 KVA LI UPS | Make: PARADYNE
Model: PARADYNE 1 KVA LI UPS | - | - | Qualified |
| 4 | Not yet disclosed by govt. Qualified Make: PARADYNE
Model: PARADYNE 1 KVA LI UPS | Make: PARADYNE
Model: PARADYNE 1 KVA LI UPS | - | - | Qualified |
| 5 | Not yet disclosed by govt. Qualified Make: BPE
Model: BPE 1KVA LI UPS 7AH*2NOS BATTERY 2YEARS | Make: BPE
Model: BPE 1KVA LI UPS 7AH*2NOS BATTERY 2YEARS | - | - | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
25 Aug 2018, 2:00 pmClosed
Line Intractive UPS with AVR Average Turn Over of Last 3 Years 1 Lakh (s) Experience with Gov. Required 5 Year (s) Line Intractive UPS With AVR ( 10 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/216 1.0/216 Technology MOSFET-PWM MOSFET-PWM
IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single phase sinewave 230v AC
50Hz Single phase sinewave 230v AC
50Hz
Single Phase Quasi-Sin-wave 230 V AC
50 Hz Degree of protection IP 20 IP 20 Inverter Efficiency (%) >/= 70% >/= 70% Warranty for the battery from the date of delivery 1 year 1 year
3 Years Warranty for Line Interactive UPS 1 Year 1 Year
2 Years
5 Years
3 Years Installation and commissioning instructions No - 1/4 CONSTRUCTIONAL Type of enclosure Mild steel - AC out put for printer (not through inverter) No Yes
No Inverter out put socket AC out put for printer (not through inverter) Not applicable 2 Three pin
3 Three pin
Hard wiring
Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 Yes - 2/4 pt-5/sec-1 Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes - Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date - - Name Of Lab - - Address of Lab - - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sorabh Kumar Mathur 181201
On Akhnoor Rajouri Road
1 Km from Akhnoor Bus Stand 10 30
432093
GEM/2018/B/61102
Line Intractive UPS with AVR
30 days
Jammu And Kashmir; Jammu
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Average Turn Over of Last 3 Years 1 Lakh (s) Experience with Gov. Required 5 Year (s) Line Intractive UPS With AVR ( 10 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/216 1.0/216 Technology MOSFET-PWM MOSFET-PWM | - | - | - |
| IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single phase sinewave 230v AC | - | - | - |
| 50Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz | - | - | - |
| Single Phase Quasi-Sin-wave 230 V AC | - | - | - |
| 50 Hz Degree of protection IP 20 IP 20 Inverter Efficiency (%) >/= 70% >/= 70% Warranty for the battery from the date of delivery 1 year 1 year | - | - | - |
| 3 Years Warranty for Line Interactive UPS 1 Year 1 Year | - | - | - |
| 2 Years | - | - | - |
| 5 Years | - | - | - |
| 3 Years Installation and commissioning instructions No - 1/4 CONSTRUCTIONAL Type of enclosure Mild steel - AC out put for printer (not through inverter) No Yes | - | - | - |
| No Inverter out put socket AC out put for printer (not through inverter) Not applicable 2 Three pin | - | - | - |
| 3 Three pin | - | - | - |
| Hard wiring | - | - | - |
| Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 Yes - 2/4 pt-5/sec-1 Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes - Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date - - Name Of Lab - - Address of Lab - - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sorabh Kumar Mathur 181201 | - | - | - |
| On Akhnoor Rajouri Road | - | - | - |
| 1 Km from Akhnoor Bus Stand 10 30 | - | - | - |
Exempted
31 Aug 2018
5 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_432093.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .