Amount
Part I- CIVIL AND PLUMBING WORKS Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil.
Excavating trenches of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,for all depth including getting out the d soil,& then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposing of surplus excavated soil as directed, within lead of 50m. All kinds of soil. Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia
Providing and laying in position cement concrete of specified grade INcluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Shelves (Cast in situ)
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral-staircases.
Edges of slabs and breaks in floors and walls
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor V level Thermo-Mechanically Treated bars
Providing and laying in position machine batched and machine mixed design mix M 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).
All works upto plinth level
All works above plinth level upto floor V level
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry (with F.P.S. bricks).
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for flooring, staircase treads , riers and landings, kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm
Providing and fixing machine cut, mirror/ eggshell polished , Marble stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different inished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of atching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in- Charge. 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadore etc.
Providing and fixing 50cm long aluminium kicking plate 100x3.15 mm anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with necessary screws etc. complete.
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 12 mm uPVC or aluminum powder coated U beading
Extra for providing frosted glass panes 5 mm thick instead of ordinary float glass panes 5 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid eparately).Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completelyfixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window - ANY)
Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately).Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Three track three panels sliding door made of (big series) frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door - any area )
Providing and fixing SS 304 sliding door bolts, including all necessary screws et.
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing & fixing glass panes with putty and glazing clips in upvc windows, windows, clerestory windows, all complete with : 5 mm thick glass panes
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm Thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. Red sand stone
Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.5 metre .
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of size 600 mm x 1200 mm or as decided / approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade all complete as per the directions of Engineer-in- charge.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Second class teak wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :
providing and fixing heavy duty ball bearing Butt hinges Brand Name : Dorset - Size : 127 x 76 x 3 inch alongwith necessary screws
Providing and fixing door lever handle brand Dorset product name Cornus
Providing and fixing lever handle with mortice lock dorset make New antic model 8inch havey plate 6×4 hardness lock body with havey cylinder combo pack
Providing and fixing door stopper HAFELE Stainless Steel Wall Mounted Door Stopper 72 mm with Screw Cover (Screws Not Seen)
Providing and fixing Hettich Door Closer with Standard arm, Fire rated, HSA 10 F: EN 2/3/4 Item code: 9227816 HSA 10 D EN: EN 2/3/4 Rack And Pinion (Symmetric) Mechanism Door Closer Finish : Silver
Providing and laying rectified Glazed Ceramic floor tiles of size 600 mm x 600 mm or as decided / approved by Engineer-in-charge (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.11.41.4 Size of Tile 1200x1200 mm
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conf`orming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Single tee without door 110x110x110 mm
Bend 87.5° 110 mm bend
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Finishing interior and specified exterior wall/ RCC surfaces with Apex ultima water based paint of Asianpaint brand- 2 coats on one coat of trucare acrylic wall putty Asian paint brand - complete as per manufacturer's specifications
Finishing interior and specified exterior wall/ RCC surfaces with Apex ultima water based paint of Asianpaint brand- 2 coats on one coat of trucare exterior wall primer Asian paint brand - complete as per manufacturer's specifications
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work on steel surface
Polishing wooden surface with melamine polish after sanding with sand paper no. 180 , then 320, then applying 2 coats of wood tech epoxy insulator then dent filling with wood tech filler then staining wood tech wood stains interiors by spraying and application of Melamyne. Then applying wood tech PU luxury wood finish coating of Asian paints brand
Providing and laying Vimzinc standing seam system using Quartz Zin type sheeting with specified purlins of cold bend z section 200x80x20x2.5 items complete with all accessories, nuts , washers, screws, cleats , plates etc. complete item as per attached drawing
Providing , filling and levelling in floor with Autoclaved aerated Cement ( AAC ) blocks
Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete.
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 20 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints ( 10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineerin- charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer
Extra for providing and mixing hardening compound of approved quality as per manufacturer’s specification in cement concrete.
Providing and laying in position bitumen hot sealing compound for expansion joints etc. 16.46.1 Using grade ‘A’ sealing compound. per cm
Providing and fixing water closets Jaquar company Florentine series Code :FLS- WHT-5953UFSM Description : Rimless Wall Hung WC with UF soft close slim seat cover, Hinges and all Accessories Size:360x545x380mm . Item includes all accessories, all type of piping,white cement, sundries , brackets etc. Complete
Providing and fixing Jaquar Wash Basin Aria ARS WHT 39903 Type:Table Top Colour:White Shape:Rectangle Dimensions:700 x 435 x 135 mm Item includes all accessories, piping, white cement, sundries , brackets etc. Complete
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge . concealed work including cutting chases and making good the walls etc.,
20 mm nominal outer dia .Pipes.
25 mm nominal outer dia .Pipes.
32 mm nominal outer dia .Pipes.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Circular tank
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore
Providing and fixing C.P. brass Single Lever Basin Mixer Jaquar brand exposed part Range :Aria Code :ARI-CHR-39233NK Description :Exposed Part Kit of Single Lever Basin Mixer Wall Mounted Consisting of Operating Lever, Cartridge Sleeve, Wall Flange, Nipple & Spout (Compatible with ALD-233N & ALD-235N)
Providing and fixing C.P. brass Single Lever Basin Mixer Jaquar brand concealed part Allied Code :ALD-CHR-233N Description :Concealed Body for Single Lever Basin Mixer Wall Mounted, But without Exposed Parts
Providing and fixing C.P. brass Bib Cock Jaquar brand Range :Aria Code :ARI- CHR-39037 Description :Bib Cock with Wall Flange
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of Jaquar brand Angle Valve with Wall Flange PRODUCT CODE: ARI-CHR-39053 PRODUCT RANGE: ARIA
Providing and fixing health faucet ( hand shower ) Jaquar brand Range :Allied Code :ALD-CHR-573 Description :Hand Shower (Health Faucet) with 8mm Dia 1.2 Meter Long Flexible Tube and Wall Hook
Providing and fixing exposed part of Divertor mixer Jaquar brand Model:ARI 39065K Type Of Mounting:Wall Mounted Type of Mixer:Manual No. Of Connections:2.0 Connection Possible To:Spout,Overhead Shower,Hand Shower,Body Shower Description:Single Lever Exposed Parts Kit of Divertor Consiting of Operating Lever, Wall Flange (with seals) & Button Only (Suitable for Item ALD-065)
Concealed Body for Single Lever Diverter 40mm Cartridge Range :Allied Code :ALD-CHR-065N Description :Concealed Body for Single Lever Diverter 40mm Cartridge with Button Assembly, Cartridge Sleeve (Button On Top) But without Exposed Parts
Providing and fixing Jaquar Round Shape Multi Flow Hand Shower HSHCHR1939 by Jaquar Features Product Type : Overhead Shower Size : 100 mm Finish : Chrome Shape : Round Material : ABS. The item to be executed inclusive of all types of piping and allied parts.
Providing and fixing Jaquar brand Overhead Shower Range :Rain Showers Code :OHS-CHR-35497 Description :Overhead Shower 200X200mm Square Shape Single Flow (ABS Body Chrome Plated with Gray Face Plate) with Rubit Cleaning System. The item to be executed completely inclusive of all types of piping and allied parts.
Jaquar Concealed Flush Tank JCS WHT 2400WS Brand Jaquar Model JCS WHT 2400WS Finish White Type Of Installation Concealed Type Of Mounting Wall Mounted Type of Frame Half Frame Flush Type Mechanical Suitable For Wall Hung WC Description Single piece slim concealed cistern with wall mounting frame, installation kit and "S-Type" drain pipe connection set for inclusive of wall hung WC oflush control plate The item to be executed completely inclusive of all types of conncting piping and allied parts.
Providing and fixing Jaquar Artize Soap Dish Holder Brass Chrome Plated Range :Kubix Prime Code :AKP-CHR-35731P Description :Soap Dish Holder
Providing and fixing Jaquar Towel Rack Hotelier Series AHS 1581H Jaquar Model AHS 1581H Location of Use Shower Area Series Hotelier Finish Chrome COMBINED DIMENSIONS 600 x 250 mm Model Fin Code AHS-CHR-1581H DESCRIPTION Towel Rack With Lower Hanger (Stainless Steel) With Hook
PROVIDING AND FIXING Jaquar Towel Ring Square Continental Series ACN 1121N Brand Jaquar Model ACN 1121N Location of Use Basin Series Continental Finish Chrome COMBINED DIMENSIONS 210 x 210 mm Model Fin Code ACN-CHR-1121N DESCRIPTION Towel Ring Square With Round Flange
Providing and fixing square-mouth S.W. gully trap class SP1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100 mm size P type. With sewer bricks conforming to IS : 4885
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportionof 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :250 mm dia. R.C.C. pipe
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 ement : 3 coarse sand) finished with floating coat of neat cement and making
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with S.F.R.C. cover and frame heavy duty, HD-20 grade designation) 560 mm internal diameter onforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : 19.28.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineerin-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and fixing soil, waste and vent pipes in uPVC SWR pipings including all fittings with or without doors . Only length is to be measured from GT , Manhole to Cowl or fittings. 110 mm dia
Providing and Fixing Delhi quatrz stone cladding of approved quality approximately in 9"x9"x4" stone sizes in approved irregular pattern with around 10 mm th. Grooves laid with 1:4 Cement , badarpur/coarse sand mortar , with recessed pointing in 1:2 Cement sand mortar in approved design. The work shall be done as per approved sample and any deviation shall have to be rectified at the risk and cost of the contractor. The cladding shall be done on the walls , in floors and on steps
P/F CPVC union approved make CPVC pipes i/c cutting and making all complete as per the directions of Engineer-in-charge.
25 mm nominal bore
32 mm nominal bore
P/F CPVC ball valve (gate valve) of approved make in CPVC pipes i/c cutting and making all complete as per the directions of Engineer-in-charge.
25 mm nominal bore
32mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length and 15 mm nominal bore
Providing and fixing CP Grating Square Grating, Size: 5" X 5"SS304 Brand Onida Shape Square Material Stainless Steel Size 5" x 5"/6" x 6" Cat No 60/3025 Model No 5120/5121 125 mm nominal dia with 25 mm waste hole/without hole
Extra for lapatto finish Granite in lieu of polished granite in item 11.56
Extra for providing 8 mm th float glass in place of 5 mm th glass in Item 34
Extra for providing 3-4mm Grout joint in tiles with letticrete epoxy grout
Extra for providing and finishing superior exposed brick work including recessed pointing as in existing Girls hostel as per approval
Extra for using shuttering ply in the soffits of slabs to achieve exposed RCC finish in addition to Item 4 c
Filling and compaction with Construction debris available at the College within 500 m Lead.
Core cutting in RCC slabs upto 200 mm thickness from 75mm to 162 mm dia for plumbing pipes
Core cutting in RCC beams upto 300 Thickness from 75mm to 162 mm dia for plumbing pipes
roviding and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
All works upto plinth level
All works above plinth level upto floor V level
Brick work with common burnt clay machine moulded F.P.S. (non modular) bricks of class designation 12.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand).
PART – II ELECTRICAL WORK
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 Sq.Mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate,suitable GI box and earthing the point with 1.5 Sq.Mm FRLS PVC insulated copper conductor single core cable etc. as required:Group A
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.:Group A
Wiring for twin control light point with 1.5 Sq.Mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 Sq.Mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for power plug with 2 x 4 Sq.Mm. FRLS PVC insulated, copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 no 4 Sq.Mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Providing and fixing hexagonal fan box circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Supply and drawing following pair, 0.5 sq.mm. FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed steel/ PVC conduit as required.2 Pair
Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches in recess etc as required:1 or 2 Module (75 mm x 75 mm)
Supplying and drawing co- axial TV cable RG-11 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinnned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required.
Supplying and fixing of following sizes of medium classPVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
15/16 amp switch
6 pin 15/16 amp socket outlet
Telephone socket outlet
TV antenna socket outlet
Bell Push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
1 or 2 Module (75mm x 75mm)
8 Module (125mm x 125mm)
12 Module (200mm x 150mm)
Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required.
1 or 2 Module
8 Module
12 Module
SITC of 10 watt mirror light fixture made of extruded aluminium housing suitable for 220 Volt AC with system lumens output of 2000 or higher colour temp. 6500K and efficacy better than 100 lumens/watt, with integral electronic driver, general colour rendering index (CRI) Ra > 80. Service life L70 (tq 25 °C) = 50,000 h. IK02/0,2 J, P.F>0.95, THD<10%, Protection IP20 etc complete as reqd.
SITC of 1200mm (Nominal Size) LED luminaire of 36-40 watt made of extruded aluminium housing suitable for 220 Volt AC with system lumens output of 2000 or higher colour temp. 6500K and efficacy better than 100 lumens/watt, with integral electronic driver, general colour rendering index (CRI) Ra > 80. Service life L70 (tq 25 °C) = 50,000 h. IK02/0,2 J, P.F>0.95, THD<10%, Protection IP20 etc complete as reqd.
SITC of 12-15W LED Recessed Downlighter with a nominal system lumen output of 1300 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70 with LG7 Complaint,new backlit design . The luminaire should have a color temperature between 4000K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF > 0.95. The luminaire housing should made of aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance etc complete as reqd.
SITC of 12-15W LED surface Downlighter with a nominal system lumen output of 1300 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70 with LG7 Complaint,new backlit design . The luminaire should have a color temperature between 4000K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF > 0.95. The luminaire housing should made of aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance etc complete as reqd.
Supplying, Installation, Testing and Commissioning of surface mounting IP-65, 10 Watt LED bulk head light fitting with polycarbonate diffuser, single phase, 100-270V AC, effiicacy 100 Lumens/ watt complete with integral electronic driver etc complete as reqd.
SITC of LED flood light fixture suitable for 70 Watt for area lighting. Optical system of high-quality UV and temperature-resistant optical lens systems with rotationally symmetrical light distribution. Floodlight housing of die-cast aluminum, powdercoated, highly weather resistant. Luminaire luminous flux 6000lm, luminous efficiency of luminaire 100 lm/W. correlated colour temperature (CCT) 6500 K, general colour rendering index (CRI) Ra > 70. Service life L70(tq 25 °C) = 50,000 h. IK05/0,2 J, P.F>0.95, THD<10%, Protection IP65 etc complete as reqd.
Providing and fixing of LED bollard luminaire of 10 Watt of height minimum 582mm as required, correlated colour temperature (CCT) 6000 K,operating voltage 120-277V. Impact resistance IK10 with LDPE protector. Service life L70(tq 25 °C) = 50,000 h. surge protection upto 10KV, Protection IP66 etc complete as reqd.
SITC OF BED LAMP FITTING switable for BC / EC LED lamp made out of stainless steel housing with antique finish with rotating neck etc as per requried .
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying, Installation, Testing and Commissioning of following sizes Heavy duty Exhaust Fan with Aluminium Louvers including connection with 3 core PVC insulated PVC sheathed flexible copper conductor cable on the existing window opening / Structure / Box complete etc. as required :300 mm sweep 900 rpm.The exhaust fan shall be fixed on minimum 10 mm thick bakelite sheet having suitable opening for exhaust fan.
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
SITC of free standing floor mounted dust and vermin proof compartmentalised IP54 cubical panels made out of CRCA sheet , required hardware ,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panels in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment /switchgear . Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure. Also TP&N aluminium busbar for 300 Amps of suitable rating for connections and other required Accessories. All complete as per CPWD specifications and direction of Engineer-in-charge.(Panels shall be TTA approved) (Including voltmeter,ammeter,indication lamp,CT,setector switch)
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
100 A, 16 KA,TPMCCB
63Amp DPMCB
Supplying of following sizes one number XLPE insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade UG Cable etc complete as required
4 x 25 Sqmm
2X16 sqmm
2X10 Sqmm
3.5X50 sqmm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
4 X 25 sq. mm (28mm)
2 X 10 sq. mm (19mm)
2 X 16 sq. mm (22mm)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way double door
12 way double door
Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB)suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required:single pole
Supplying and fixing 63 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required:63 Amps
Supply and fixing modular type A/C box complete with 16amp socket outlet 6 to 32 amp SPMCB, cover plate,connection testing and fixing etc as reqd
SITC of 1.5 Tr capacity air conditioner, 5 star rated Inverter type having only cooling facility suitable for operation of 215±10% volt, 50 HZ, A.C supply with ecofriendly gas having cordless remote control, fittings & required one copper conductor cable to connect unit to socket out with 3 pin 25 amp plug top. Installation and commission of unit to be complete in all respect with satisfaction of engineer-in- charge.Completed with upto 3 mtr refrigerant pipe and copper conductor cable of suitable size duly insulated with nitrile rubber tubular insulation between each set of indoor & outdoor units including making hole in the wall with the help of core cutter including repairing etc as per specification.(Note: The outdoor unit & indoor unit shall have copper coil for condenser and evaporater)
SITC of 1.5 Tr capacity air conditioner, 5 star rated Inverter type having only cooling facility suitable for operation of 215±10% volt, 50 HZ, A.C supply with ecofriendly gas having cordless remote control, fittings & required one copper conductor cable to connect unit to socket out with 3 pin 25 amp plug top. Installation and commission of unit to be complete in all respect with satisfaction of engineer-in- charge.Completed with upto 3 mtr refrigerant pipe and copper conductor cable of suitable size duly insulated with nitrile rubber tubular insulation between each set of indoor & outdoor units including making hole in the wall with the help of core cutter including repairing etc as per specification.(Note: The outdoor unit & indoor unit shall have copper coil for condenser and evaporater)
Supplying, Installation and welding the copper pipe with the existing pipe of 1.5 TR /2.0 TR refrigerant copper pipe work with fitting duly insulated with 19/13 mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specification all piping inside the room shall be properly supported with M. S. hanger / angles / clamping arrangement, dash fasteners suitably run on existing cable tray etc. as required.
Supplying and Laying of one number 3 core 1.5/2.5 sqmm pvc insulated and pvc sheathed round wire on wall/surface/with refrigerant pipe etc for AC.
3 c (2.5 sqmm) Electrical wiring from MCB to outdoor units (BIS)
6 sq mm Electrical wiring from MCB to outdoor units as / BIS
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - 25 mm nominal outer dia Pipes- recessed in walls
Voltage stabilizers 4 KVA for A/C
SITC of 1.5TR AC Outdoor unit powder coated stand required as per site condition wall / Floor Mounted.
Comprehensive Annual Maintenance of 1.5 Tr capacity Inverter type Split AC as per manufacturer recommendation including servicing of the AC ,Refrigerant gas charging , replacement of compressor, motor,wiring,etc complete with all parts required for healthy and proper functioning of the Air Conditioning.(Nothing will be provided by the department during the period)
Year 1 (after Defect Liability Period of One Year)
Supply and fixing of Gyeaser/ water heater 25 Ltrs capicity complete as read (Make:-Hevells - WB025 or eqvialent Recold/Smith)
Supply installation testing and commissioning R.O.water purifier (Kent Grand 8 L RO + UV +UF Water Purifier (White)
Supplying, installing, testing & commissioning of Domestic Water Lifting Pumps to feed Overhead Tank. (1HP) including all fittings as per direction of Engineer-in- charge. Location - Near underground water tank Part III Miscellaneous
If there are any extra items which are not covered in items given above they shall be paid at a fixed percentage below or above DSR 2018 as per the percentage decided in the beginning. Please quote the net percentage rate here . For example if the contractor wants to quote 5% below DSR 2018 please fill .95 . So that amount shall become Rs. 1,90,000/-
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .