Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 CrAccepted-AOC | ₹3.7 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹3.9 Cr+₹18.4 L (4.96%)Rejected-Finance | ₹3.9 Cr+₹18.4 L (4.96%) | L2 | Rejected-Finance Other Than L1 |
Tender Value
₹3.6 Cr
EMD Value
₹4.4 L
Closing Date
9 Sept 2023, 9:00 amClosed
HQ,Chief Engineer Lucknow Zone ,Lucknow
HQ,Chief Engineer Lucknow Zone 17, Carriappa Marg Lucknow Cantt PIN -226002
PROVN OF OT FOR MH AYODHYA.
2023_MES_586208_3
CELZ/AYOA/T-06 OF 2022-23
Open Tender
Civil Works
Lump-sum
300 days
AGE (I) AYODHYA
Please refer tender documents
8 documents required · 8 mandatory
₹2,000
AGE (I) Ayodhya
₹4.4 L
Yes
29 Sept 2023
12 Aug 2023
11 Sept 2023
12 Aug 2023
9 Sept 2023
27 Aug 2023
Amount
Sch 'A' Part-I (Buildings & Structures Work) Note : This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5.
Total amount of Sch 'A' Part II (Site clearance, excavation and earth work)
Total amount of Sch 'A' Part III (Internal Water Supply )
Total amount of Sch 'A' Part IV (Internal Electrification)
Total amount of Sch 'A' Part V (Sewage Disposal)
Total amount of Sch 'A' Part VI ( Fire Alarm System)
Total amount of Sch 'A' Part VII (Area Drainage)
Total amount of Sch 'A' Part VIII (Road/Path/Culvert)
Total amount of Sch 'A' Part IX (External Water Supply )
Total amount of Sch 'A' Part X (External Electrification )
Sch 'A' Part - XI (Miscellaneous Items for B&R AND E&M) Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 signifies this fact only.
INTERNAL WATER SUPPLY S&F Two way Angle cock Angle valve, cast copper alloy, chromium plated fancy type, screwed down, high pressure screwed both ends for iron pipe 15 mm bore complete all as per specified & directed.
S&F health faucet (1.50 meter tube) with hook (hand spray ) with CP body, complete all as specified & directed.
INTERNAL ELECTRIFICATION M&L for point wiring complete for One light/Fan/Exhaust fan/Bell point controlled by one switch with PVC insulated and unsheathed ,FRLSH cable 1.5 sqmm (nominal area), ISI marked,multi stranded copper conductor cable including ISI marked not less than 20 mm dia medium grade PVC conduit concealed in wall , roof/floors, factory made pressed steel concealed terminal boxes not less than 1.6mm thick of reqd size including 1.5 Sqmm PVC ,FRLSH cable insulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified & directed.
All as per item no 14 of above but for One 5 pin 5 Amp switch socket out let point on an independent board complete all as specified & directed.
M&L for point wiring complete with PVC insulated and unsheathed,FRLSH cable 2.5 sqmm (nominal area) ,ISI marked, stranded copper conductor single core including ISI marked not less than 20mm dia medium grade PVC conduit concealed in wall and MS conduit in roof/floor slab, pressed GI concealed terminal boxes not less than 1.6mm thick of reqd size including 2.5 Sqmm,FRLS cable PVC insulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as per specified & directed.
S&F LED batten Tube light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 FT 20 W), luminaire lumen >2000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficiency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification. Complete all as specified and directed
S&F LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 10 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficiency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification. Complete all as specified and directed.
S&F LED Building security light fitting with aluminum pressure die cast housing, high purity PC Fresnel diffuser with silicon gasket for IP-65 protection, power consumption <30 W/ (30W) & luminaire lumen >3500 lm and system efficiency > 120 lm/W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor >0.95 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 35/40 mm dia /suitable dia light grade bend to shape security light fitting with necessary MS clamp 25 mm wide and 6 mm in thickness in suitable length not more than 30 CM and max length of pipe 1.5 MITRE long with one code of anti corrosive primer and two coats aluminum paint including nuts, bolts and washers complete all as specified and directed.
S&F MCCB 4 pole ,415 V ,AC fixed type 200 amps with breaking capacity 25 KA complete all as specified and directed.
S&F MCCB VTPN DB double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed.
M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 meter deep below normal ground level) with top edge of plate not less than 1.5 meter. below ground level connecting to galvanised earth lead wire 4.0 mm dia as earth lead upto 7.5 meters long connected by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe medium grade, 15 mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 40 x 40 x 3mm fixing with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 meter long placed on top edge plate, common salt and charcoal filling, with fixing arrangement, funnel, wire mesh and earth work in hard / dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 meter, all as per electrical plate No 3 of SSR 2009 Part-I and connection all as specified and testing on completion. Note: The cost of excavation and earth work, PCC pit and pit covers, funnel and watering pipe, wire mesh, charcoal dust and common salt,20/ 40mm dia, medium grade, GI pipe as protection to GI wire 4.0 mm as main earthing lead from earth electrode to main TPN MCCBs DB/MCB DB/ test point length not less than 7.5mtrs) shall be deemed included in the unit rate for earthing and testing complete all as specified and directed .
SEWAGE DISPOSAL RCC Septic tank conventional types designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 type type B2 using 40 mm graded stone aggregate below foundation, RCC M30 design mix in walls ,base slab ,baffle walls and and roof slab including beam etc with vent soft, manhole opening with cover connection etc complete with effected depth of 1.5 meter and over all depth 3 metre for 50 users complete all as specified ,shown on Drg No. TD/750 sheet 1/2 to 2/2 complete all as specified and directed.
Soakage wells 1.80 meter dia and 4.50 meter effective depth, excavation, in any type of soil, foundation in pcc 1:3:6, walls of honey combed masonry with top ring of M-30 concrete including intercepting chamber and screen chamber made of brick masonry in cm,RCC cover slab in M-25 / SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size complete all as specified ,shown on Drg No TD/576 sheet 1/2 and 2/2 complete all as specified and directed.
FIRE ALARM SYSTEM M & L for Earthing complete with galvanised steel earth plate electrode 60x60cmx 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the plate not less than 1.25 meter below normal ground level, connected to galvanised 32 mm x 6 mm earth strip by means of nuts, bolts, washer of GI steel as shown on electrical plant No 3 of MES schedule part I connected to earthing test point and testing on completion with including necessary excavation and earth work, earth electrode, earthing lead from electrode to equipment /substation , adequate quantity of charcoal dust and common salt , test point pcc (1:3:6) type C-I (using 20mm graded black trap/granite/basalt stone aggregate) for earth pit with 40x40x6mm mild steel angle iron frame for cover,pre-cast RCC (1:2:4) type B-I (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 15mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, 7.5 meter only from the top of earth electrode are deemed to be included under this item and additional earth lead, if any, required at site shall be measured and paid for separately under appropriate item of schedule `A' complete all as specified and as directed
EXTERNAL ELECTRIFICATION Supply, installation, testing and commissioning of copper wound step down Transformer, outdoor type floor mounted complete with standard fittings, HT, 11 KV, 3 phase, LT, 433 volts at no load, 3 phase, 4 wire, 50 Hz AC of capacity 315 KVA with oil immersed naturally cooled, delta connected on HV side and star connected on LV side in accordance with vector symbol DY-II with neutral brought out on secondary side and having taping in step of ± 2.5 %/ ± 5%, and ± 7.5% to be changed by means of hand operated off load tap changing gear arrangement including first fill of transformer oil as per IS-355, oil temperature gauge 96mm dia type, dehydrating breather with first fill of dehydrating agent, oil conservator, explosion vent, ring and terminal marking plate, oil level gauge, oil drain and filter valve, lifting lugs, extra bushing with internal connection with neutral on LT side, out side cable box for providing independent earthing and two earthing terminal for transformer body earthing and including all fittings/ accessories as specified in SSR Part-I and IS:2026 including RCC/PCC foundation as per manufacturer's recommendation all specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm complete all as specified and directed.
S&F in repairs Cable End jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
Supply and fix HT 11 KV, out door type gang operated air-break switch, Triple pole, mechanically operated, mounted on insulator and steel, frame, with operating mechanism worked from ground level, for current rating upto 400 Amps complete all specified and directed.
Supply and fix Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed.
Supply and fixing stay assembly complete with accessories shown in electrical plate No 1 with stay rod of 20 mm dia including loop insulator suitable for 11 KV (size 90x140 mm) with clearance of hole 25.5mm and MS stay plate size 300 x 300 x 6mm, stay clamps etc complete all as specified and directed.
Supply and fixing stay wire of galvanised iron stranded of size 7/4 mm complete all as specified and directed.
Supply and Fix Steel tubular swaged poles 11.0 meters long complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 all complete all as specified and directed.
M/L for Cement concrete for filling in foundations or making good of Road, PCC Floor, supports etc. Type B1, 1:2:4, using 20 mm graded stone aggregate including necessary form work and fair finishing of exposed surface of concrete / facia finish with cement mortar complete all as specified and directed.
BLANK
Earth continuity conductor or main earthing lead fixed to walls or to poles or any other indicated situation for loop earthing with 25mm x 4 mm galvanised iron strip complete all as specified and directed.
Supply, laying and testing 400 sqmm 3.5 core cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and as directed .
Supply, laying and testing 150 sqmm 3.5 core cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and as directed .
Supply, laying and testing 95 sqmm 3.5 core cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and as directed .
Supply, laying and testing 16 sqmm 4 core cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor complete all as specified and as directed .
M & L for C I cable rout indicator / Marker with necessary HV cable marking including fixing in PCC complete all as specified and directed.
M&L for mild steel work with angle iron, channel etc as in post and struts in fencing including cutting tops to shape, as directed, drilling holes, notching for wire etc flat iron fillets (for securing wire mess etc) including all necessary drilling, bolting or riveting etc complete all as specified and directed.
M&L for chain link fencing galvanised including line wires 4 mm dia, mesh size 150x100mm weight not less than 2.3 Kg/sqm and type of standards rails, straining bolts etc. Including provision of binding wire and fixing complete all as specified and directed.
TELEPHONE CONDUIT Supply and fix Rigid non metallic PVC conduit (medium quality) (ISI marked) 2 mm thick exclusive of boxes (junction/terminal) 20 mm dia for telephone wiring including all fittings such as tees, bends, reducers, bell mouth tube ends and all fixing such as couplers, bolt, nuts, saddles, pipe hooks etc complete all as specified and directed.
S&F PVC junction box (1 to 4 way) of size 20 mm complete all as specified and directed.
Supply and fix telephone socket RJ 14, 1 module complete all as specified and directed.
HOT WATER Supply, Install, Test & Commissioning, Water Resistant / Splash Proof (IPX-4), Whirl flow technology, Electric Water Storage Heater (Geyser) 25 Liters capacity, Vertical Type, 5 Star Rated, ISI Marked, Energy Efficient, having Feroglass coated / Anode Rod protected inner container / Tank, Incoloy Glass Coated Heating Element, High Density PUF insulated, Multi Function Safety Valve, Fire Retardant ISI Marked Heavy duty 3 core cable with shock Resistant Plug Top, Temperature Sensitive LED indicators, Adjustable Temperature Setting, 0.8MPa high working Pressure, Complete including suitable size Anchoring / Grouting Bolts with Nuts & Washers, necessary grouting in PCC incl earthing testing for the Geyser complete all as specified and directed.
Supply, Fix & Connect, Heavy duty PVC wired flexi connection pipe accessory 450mm with check nuts suitable for Hot water application complete all as specified and directed.
HAND DRYER & SCRUB SINK :- Supply and fix 3 Bay Scrub Sink Automatic sensor with option for foot operation of stainless steel body, material SS 304-18 SWG rust proof material with soap dispenser for Operation theater complete all as specified and directed. Make CMD Model NO CMPP3SSASF /TRION / RYD/AIR /HUMIDIN /EAPAIR
Supply, install, testing and commissioning of Electronic infra red Sensor operated Automatic Hand Dryer with air flow at temp 47 to 52 OC (approx), with heating element (approx 1500 watt) protected by thermal cut-off and thermoplastic fan wheel coupled with single phase induction motor suitable for 220-240 Volt, 50 Hz AC supply model: Optima Hand Dryer, Code: HDR-SAP-M99 ACS of including fixing arrangement complete all as specified and directed.
UPS Supply , install and testing Online UPS 30 KVA for 30 min back up three phase AC input 300 to 450V and out put three phase 360 V ± 1% of capacity 30 KVA including batteries, battery tray and racks powder coated painted including UPS supply wiring complete all as specified and directed. (a) Voltage Input - 360Volt AC, 50 Hz (b) Phase input - 3 Phase (c) Input power factor>0.95 (d) Output voltage - 360 Volt AC ± 1% (e) Output frequency -50Hz (f) Output power factor - as per manufacturers (g) Battery type- External battery bank with battery tray/racks (No of batteries and capacity required for 30 Min backup on full load) (h) Battery charging time fully - upto 8 hrs (i) Inbuilt Isolation Transformer of suitable size (j) Efficiency over all->90%, Inverter.>92% (k) Alarm & Indication: Battery mode, low battery, over load, fault, load/ battery level utility power, Inverter, Bypass over load etc. (l) MCBs for Input and output as per required capacity. (m) Cooling fan as per manufacturer's designed.
BLANK
Submain wiring with two single core 1.5 sqmm FRLS copper con-ductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit concealed in wall surface / ceiling for sub main connection including 1.5 sqmm FRLS PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note : Two single core 1.5 sqmm copper conductor, one run PVC conduit and one run of 1.50 Sqmm earth wire shall be considered and measured as one unit.
WATER COOLER supply and installation of Water Cooler of capacity 80 liter storage and nominal cooling capacity 40 liter per hour, connecting to GI tubing by means of and including PVC pipe connection with brass coupling, nuts at both ends
Supply and fixing of Refrigerator of capacity 190 to 210 liter, electric driven, single phase, 230 volts AC 50 Hz 5 star rated with inverter including plug top 5/15 Amps and necessary electric connection complete all as specified and directed.
OT LIGHT (Major OT) Supply, installation, commissioning and testing of LED based ceiling suspended double dome Operation Theater Light with provision only for Camera to be fitted inside the dome as and when required at later stage in compliance with medical device electric standard IEC-60601-2- 41, with each dome consisting of minimum 30 LED's and maximum 120 LED's housed in dome with diameter ranging between 500 mm, suspended through a ceiling assembly with spring arm system to provide precise positioning of the OT light as required during surgery complete with UPS including sealed Maintenance free batteries to provide instantaneous backup in case of power failure for 30 minutes complete with all necessary wiring for hanging arrangements as per manufacturers guidelines with following specifications :- TECHNICAL SPECIFICATION FOR MAIN DOME AND SATELLITE DOME (a) Intensity @ 1 Meter (Lux) 160000+10% (b) Adjustable Field diameter (cm) 14-38 (c) Depth of illumination L1+L2 (cm) > 100 Color (d) Rendering Index (CRI) (Ra) 95 + 3% (e) Color temperature (K) 4500+10% (f) Intensity control (%) 25-100 (g) field focusing control by sterllizable handle (h) Intensity control by control panel on lamp head ELECTRICAL & MECHANICAL SPECIFICATIONS (i) Power Supply input voltage (V) 220-230 V Power (ii) Consumption (W) < 150 (iii) Frequency (Htz) 50/60 (iv) Dome Diameter 500-700 mm (v) LED service life (hrs) > 40,000
OT LIGHT (Minor OT) Supply, installation, commissioning and testing of LED based ceiling suspended double dome Operation Theater Light with provision only for Camera to be fitted inside the dome as and when required at later stage in compliance with medical device electric standard IEC-60601-2- 41, with each dome consisting of minimum 30 LED's and maximum 120 LED's housed in dome with diameter ranging between 500 mm, suspended through a ceiling assembly with spring arm system to provide precise positioning of the OT light as required during surgery complete with UPS including sealed Maintenance free batteries to provide instantaneous backup in case of power failure for 30 minutes complete with all necessary wiring for hanging arrangements as per manufacturers guidelines with following specifications :- TECHNICAL SPECIFICATION FOR MAIN DOME AND SATELLITE DOME (a) Intensity @ 1 Meter (Lux) 120000+10% (b) Adjustable Field diameter (cm) 14-38 (c) Depth of illumination L1+L2 (cm) > 100 Color (d) Rendering Index (CRI) (Ra) 95 + 3% (e) Color temperature (K) 4500+10% (f) Intensity control (%) 25-100 (g) field focusing control by sterllizable handle (h) Intensity control by control panel on lamp head ELECTRICAL & MECHANICAL SPECIFICATIONS (i) Power Supply input voltage (V) 220-230 V Power (ii) Consumption (W) < 150 (iii) Frequency (Htz) 50/60 (iv) Dome Diameter 500-700 mm (v) LED service life (hrs) > 40,000
MODULAR OT EQPT (Minor/Major) "M & L for under deck insulation for RCC roof with bonded fiber glass wool of density 48 Kg/Cum, 75 mm thick, suitably factory laminated with aluminium foil having flange on one side, backed up by scrim and Kraft paper, comprising of the following (insulating material shall conform to BS - 476, Part 4,5, 6 & 7):-“(a) S & F 50 x 50 mm or 75 x 75 mm slotted angles 50 mm wide, fixed to the ceiling by means of rawl plug 600 mm centre to centre.“(b) Supply and draw GI tie wire 22 Gauge from vertical slots, for holding the insulating material in position with and including GI washer.“(c) S & F aluminium foil, adhesive tape 50 mm for sealing of aluminium foil flanges.“(d) Providing additional support to the insulation with and including chicken wire mesh of size 12.5 mm x 0.51 mm (24 SWG) hexagonal construction, stretched firmly over the insulation and fixed all as specified and directed.
BLANK
Supply, installations, testing and commissioning Laminer air flow system Plenum unit for laminar flow diffuser will be made of thick aluminium or steel sheet. The complete unit will have factory prepared fine sealing system along with proper test certificates. The plenum will be supplied at site duly sealed in factory made packing. The Caracas of the plenum will be made of 1.6 mm sheet which will have an external flange on the housings in such a manner that the air is passed only through the minipleat Hepafilters .Each Minipleat heap Filter will be accompanied by a test certificate of this regard will be provided along with the unit. The Laminar flow system will have anodized aluminum or steel perforated diffuser grill. The laminar flow system will have such design that it provides cleanliness of class 100. (< = 100 particles/ft3) and bacteriological class B (< = 20 cfu/m3). The absolute filters installed in the plenum will be suitable for applications for Laminar flow and clean rooms, these absolute filters will be mini pleat HEPA filters having extruded anodized aluminium or steel , 75 mm deep frame and 90mm deep frame, The filter will provide flow uniformity exceeding +-2.5% meeting following specifications: Protective grids –Aluminum or steel Perforated sheet duly Anodized. Separators - Continuous thermo plastic chord (HOT MELT TECHNOLOGY) Imported Sealant- Polyurethane Gasket One piece polyurethane - 5 EN 1822 class H14 0.3 micron DOP efficiency >- 99.999% Final pressure drop - 600 Pa (maximum) Maximum operating temperature - 80 degree centigrade Maximum RH- 90 percent Designed in accordance with HTM 2025 standard.
Supply, installations, testing and commissioning of Surgeon Control panel : 9 service tiles control panel should be built to HTM 2025 standard and Electrical Regulation included with following features: (a) Elapsed Time clock whose control module meets IP67 and includes tactile push buttons and status 1.8” RED LED indicators. (ii) Real Time Digital clock with battery back up having 1.8” GREEN Display. (iii) 3 Channel ( 2 for Peripheral light and 1 for plenum )General Theatre lighting controls with 0-10V dimming range. (iv) Air conditioning controls and indicators.( Temperature & Humidity). (v) Gas Alarm – 4 gases and Vacuum (vi) Hands Free Phone on panel. (vii) Display Room Air Pressure
Supply and installations of Twin X Ray View Plate with Fluorescent lamps with all accessories complete all as specified and directed.
Supply, installations, testing and commissioning of OT pendant, supply voltage 100-230 V, AC 50/60 Hz ceiling mounted and suspended part moving by 340 degrees included with following features: (a) 2 Nos O2 Outlets, 2 OS Vacuum, 1 No Air 4 bar Outlets. (b) Provision of 6 Nos Electrical Switch/socket. (c) Provision of IV Stand. (d) An Equipment carrier with maximum Load capacity of 100 KGs to be provided complete all as specified and directed.
Sub main wiring with four single core 10 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit concealed in wall surface / ceiling for sub main connection including 10 sqmm FRLS PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note : Four single core 10 sqmm copper conductor, one run PVC conduit and one run of 10 Sqmm earth wire shall be considered and measured as one unit.
BLANK
BLANK
MEDICAL GAS Supply, installations, testing and commissioning of copper pipe of size 15 mm outlet dia with 0.90 mm wall thickness, seamless, deoxidized, non arsenical, half hard, lempered and degrees manufactured as per BS 6017 of 1981 table 2, Gu-DHP complete all as specified and directed.
Supply, installations, testing and commissioning of copper pipe of size 12 mm outlet dia with 0.70 mm wall thickness, seamless, deoxidized, non arsenical, half hard, lempered and degrees manufactured as per BS 6017 of 1981 table 2, Gu-DHP complete all as specified and directed.
Supply, installations, testing and commissioning of duplex Vacuum Plant 35 CFM Capacity, 3 phase comprising of the following: (i)Duplex reciprocating vacuum pump of 35 CFM capacity-01 No (ii)Receiver tank of 500 ltr capacity with auto drain valve (iii)The pump should supply with Suitable capacity of motor as per manufacturer requirement (iv) It should be supply with suitable vacuum pressure switches Associated accessories & Electricals. - 01 Set.
Supply, installations, testing and commissioning of Extruded Aluminium bed head panel, 1.2 meter in length, 4 Nos of gas outlets( Oxygen, Nitrous oxide, vacuum & compressed air) with required accessories, 04 Nos of electrical Switch/ sockets ,railing facility, vacuum jar holder, IV Rod, Nurse call system, medicine holder basket complete all as specified and directed.
DG SET Supply, erecting, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 256 KW (320 KVA), water cooled, with AMF panel 415 Volts(AC Three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet , outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Jassai.(Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation( of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB guidelines and Comprising of followings:-
(i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection ,4/6 cylinders, four stroke, confirming to ISO3046/BS 5514, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 256 KW (320 KVA) at outdoor atmospheric conditions at MH Faizabad ,(Taking all derating factor into consideration), 12/24 Volt (as per manufacturer recommendations) electric battery start, complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system(Shut down, High water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc .
(ii) ALTERNATOR: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 256 KW (320 KVA) Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class "H", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine. (iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications. (iv) AMF CONTROL PANEL: Factory made cubicle type floor mounted LT Panel board, indoor type made out of MS angle not less than 40X40X5 mm, and 2 mm thick MS CRCA sheet , front opening type protection class IP-54 , duly powder coated after seven tank process with electrolytic grace copper bus bar of 500 Amps capacity for four poles, with all standard switchgear and protection, internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of followings:-
(v) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and ox, 70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, labeling certification etc as laid down in GSR No 371(E) dt 17 May 2002. (vi) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M (vii) Diesel storage tank of capacity adequate for storage of diesel for 12 hours operation of Gen Set. (viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. (Note : 01 Number 19mm thick rubber mat of size 2mx1m as specified shall be provided. The rate quoted shall be deemed to be inclusive of these provisions.
FIRE FIGHTING Supply, install, Connecting, Testing and Commissioning on PCC Platform, Booster Fire pump, electrically driven horizontal end roof Suction, centrifugal type, 30 Mtr Head, 450 LPM, 2900 RPM having a minimum discharge pressure of 3.5kg/Cm² at roof with suitable M S channel Base duly painted suitable for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing / Body, Bronze impeller and Stainless Steel shaft, Bronze shaft sleeve, mounted on heavy duty bearings, suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity, suitable for automatic operation with non over loading power characteristics for frequent start / stop operation including necessary heavy duty gasket, G I Bolts, G I Nuts, G I Washers etc all as specified and directed.
Supply and fix Pressure gauge 100 mm (4'') dia 0 - 14Kg/cm² pressure rating all as directed.
Supply and fix 80mm bore hand operated butterfly valve of pressure rating not less than 15Kg/cm² flanged type including necessary heavy duty gasket, G I Bolts, G I Nuts, G I Washers etc all as directed.
Supply and fix MS flanged pipe 80 mm NB heavy duty with flanged ends heavy duty ISI marked with all fittings like elbow, tee, bend, socket, reducers, flange, taper, nut, bolt, heavy duty gasket, G I Bolts, G I Nuts, G I Washers etc. fixed on walls or floor or roof with necessary clamps / supports made out of suitable size Ankle Iron and MS Flat for building/ trenches duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer all as specified and directed
Supply and fix MS flanged pipe 25mm NB heavy duty with flanged ends heavy duty ISI marked with all fittings like elbow, tee, bend, socket, reducers, flange, taper, nut, bolt, heavy duty gasket, G I Bolts, G I Nuts, G I Washers etc. fixed on walls or floor or roof with necessary clamps / supports made out of suitable size Ankle Iron and MS Flat for building/ trenches duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer complete all as specified and directed.
Supply and fix Cast Copper Alloy 25mm bore hand operated Ball Valve duly threaded all as directed.
Supply and fix on wall using Anchoring bolts at suitable location, fabricated First Aid Hose Reel Drum for Fire Fighting fixed / swinging wall mounted type ISI marked along with ISI marked Thermo Hybrid Compound hose pipe 10 Kgf/cm² 30 Mtr long, 20mm dia conforming to IS:12585 suitable for fire hose drum with 25mm threaded inlet and 20mm outlet all complete all as specified and directed.
Supply and fix Yard hydrant Post / Stand Post 80mm Dia GI both end flanged type 1.5m Height duly painted with 2 coats of Signal Red Synthetic Enamel paint including necessary heavy duty gasket, G I Bolts, G I Nuts, G I Washers etc complete all as specified and directed.
Supply and fix flanged outlet TWO way inlet Breeching (fire brigade inlet connection suction collecting head) having Cast Iron Body consisting of four nos 63mm dia instantaneous type Gun metal adaptors / Couplers with PVC blank cap and chain including necessary heavy duty gasket, G I Bolts, G I Nuts, G I Washers etc. complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of 25 Sqmm 3.5 Core complete all as specified and directed.
S & F 5000 Ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position complete all as specified and directed.
Supply only Fire Extinguisher CO2 based with squeeze grip of capacity 4.5 KG complete all as specified and directed.
Supply only Fire Extinguisher ABC powder based with squeeze grip of capacity 4 KG complete all as specified and directed.
Supply & Fix sheet metal enclosure with socket plug top Triple pole and earth enclosure with a three pin and earth plug socket with one triple pole MCB 32 Amp complete all as specified and directed.
Sub main wiring with two single core 6 sqmm copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit medium grade not less than 20mm dia concealed in wall surface / ceiling for sub main connection including 6 sqmm PVC FRLSH insulated multistranded un-sheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified. Note:- Two single core 6 sqmm copper conductor, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit.
Sub main wiring with four single core 6 sqmm copper conductor, PVC FRLSH insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit medium grade not less than 25 mm dia concealed in wall surface / ceiling for sub main connection including two runs of 6 sqmm PVC FRLSH insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified (Note:- four single core 6 sqmm copper conductor as 3 phase, one run PVC conduit and two runs of 6 sqmm earth wire shall be considered & measured as one unit.
SNG BUILDERS AND ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .