| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹19.9 L+₹2.9 L (17.3%)Rejected-Finance | L2 | Rejected-Finance Not being lowest |
Tender Value
₹15.5 L
EMD Value
₹31,000
Closing Date
20 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer Shillong Zone
HQ Chief Engineer Shillong Zone SE Falls Shillong 793011
PROVN OF TWO(2) BOREWELLS AT LEIMAKHONG
2020_MES_347213_1
CESZ/LEI/09 OF 2020-2021
Open Tender
Water Equipments/ Meter/ Drilling/ Boring
Item Rate
180 days
LEIMAKHONG
As per NIT / Tender Doc
2 documents required · 2 mandatory
₹500
GE 869 EWS
₹31,000
Yes
8 Aug 2020
23 May 2020
22 Jun 2020
23 May 2020
20 Jun 2020
8 Jun 2020
26 May 2020 - 1 Jun 2020
90 days
Amount
NOTE (Applicable for all items):- The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A' BOQ
Shifting of T&P to site and back for and including Electric logging of bore precise delineation of granular zones & also the quality of ground water including report interpretation complete all as specified and as directed. Note:- Electrical logging shall be carried out by any approved Govt. Agency.
Supplying assembling , jointing and lowering 6.35 mm (minimum) wall thickness & 200 mm diameter(internal) ERW MS casing pipes conforming to IS-4270-2001 or IS 3589 (Steel tubes used for water wells) and fixing in position (including necessary cleaning internal and external surfaces and painting inside and outside of pipes with two coats of anti corrosive black bituminous paint suitable for drinking purpose over a coat of Zink oxide primer) in different depth as directed, screwed, socketed, plain ended, jointed with heavy duty suitable size collar(stiffners) and necessary electric arc welding surrounding the pipe with 04 Nos stiffners of flat iron 40mm x 6mm thick, 300mm long both sides complete all as specified and as directed. Note:-Pipes shall be of length 06 Mtr unless required in smaller lengths as per borewell requirement.
Supplying assembling , jointing and lowering 6.35 mm (minimum) wall thickness & 150 mm diameter(internal) ERW MS casing pipes conforming to IS-4270-2001 or IS 3589 (Steel tubes used for water wells) and fixing in position (including necessary cleaning internal and external surfaces and painting inside and outside of pipes with two coats of anti corrosive black bituminous paint suitable for drinking purpose over a coat of Zink oxide primer) in different depth as directed, screwed, socketed, plain ended, jointed with heavy duty suitable size collar(stiffners) and necessary electric arc welding surrounding the pipe with 04 Nos stiffners of flat iron 40mm x 6mm thick, 300mm long both sides complete all as specified and as directed. Note:-Pipes shall be of length 06 Mtr unless required in smaller lengths as per borewell requirement.
Supply assembling , jointing and lowering 6.35 mm wall thick & 150 mm internal (low carbon galvanised) (LCG) 'V' wire cage type strainer pipe conforming to IS -8110-2000 of slot 1 mm and fixing in position (including necessary cleaning internal and external surfaces and painting inside and outside of pipes with two coats of black paint suitable for drinking purpose over a coat of primer) in different depth as directed and welded with MS pipe and jointed with heavy duty suitable size collar complete with butt welding surrounding the pipes complete all as specified and as directed. Note:-Pipes shall be of length 06 Mtr unless required in smaller lengths as per borewell requirement.
Supply and fixing of MS Taper reducer 200x150 mm having 10 mm wall thickness heavy duty with and including socket threaded as per IS 226 : 1975 for jointing casing/blank pipe of bore well including necessary welding work complete all as specified and as directed. Note: - (i) Quoted rate shall deem to be inclusive of Arc welding , machining, welding materials and anti-corrosive black bituminous paint suitable for drinking purpose both internal and external surface of pipe.
Supplying assembling , jointing, welding and lowering bail plug having not less than 3.00 mtrs long and 150mm bore dia MS ERW pipe (conforming to IS -226 : 1975) having wall thickness 6.35 mm and one end closed by 6 mm thick MS plate welded and fixing in position (including necessary cleaning internal and external and painting inside of pipes with two coat with black paint suitable for drinking purpose) and fixed at bottom of casing pipe plain ended and jointed by suitable size socket with full welding complete to made leak proof complete all as specified and directed.
Supply and placing pea gravel packing (gravel size 3mm to 5 mm as per IS or as per Geologist report) throughout annular space of the tube well assembly & slotted pipe of bore well up to required depth complete all as specified and as directed. Note: - (i) Measurement of pea gravel shall be taken in measuring box at site & the same shall be record in MB duly signed by Engineer-in-Charge before packing surrounding the tube well assembly (From the total volume 10% of the volume shall be deducted & net volume thereafter shall be considered for the purpose of the payment).
Supply and fixing well cap in two parts out of MS plate 6mm thick for covering tube well internal dia 200mm & 100mm depth duly welded with locking arrangement, including making holes for passing submersible cable & one run of support chain complete all as specified and directed. Note:- After complition of the work well cap will be used to keep the borewell closed untill the submersible pumping set is installed.
M&L for development of tube well with air compressor as per IS : 11189-1985 of suitable capacity till sand/mud free water of potable quality is obtained and to achieve minimum discharging capacity of 61000 LPH/ Max yield complete all as specified and directed by GE. Note: - Compressor with accessories and fuel shall be arranged by the contractor at the own cost.
M&L for development of tube well as per IS : 11189-1985 by over pumping 25 % using suitable size/type pump after completion of Srl Item No 10, Including Yield testing for both tube well as per IS : 2800-2 1979. Note: - (i) Yield test of both borewell shall be carried out in the presence of representative of Accepting Officer. (ii) "V" Notch & other equipment included diesel driven pump set including fuel shall be arranged by the contractor at the own cost.
Supply only strata sample box with glass cover 3 mm thick having internal dimension 1000mm x 600mm x 100mm made out of 20mm thick wrought Ist class hard wood shisham with hinges, hasp and staple including polishing complete with samples at various depth every 2 Mtr interval met in boring including lithological log strata chart in duplicate complete all as specified and as directed. Note:- The contractor should also make and provide a record of discharge, draw down and depth to water level duly recoreded in duplicate for official information and record.
M&L for sanitary sealing of tube well with PCC (1:2:4) type B1 of suitable size using 20mm graded aggregate of size 1Mtr x 1Mtr x 1Mtr wth embedded gravel feed pipe of 80 mm size 2 Mtr long with capacity complete all as specified and as directed.
Testing of raw water for all parameters, chemical and bacteriological aspect such as ph value, dissolved solids, hardness as CaCo3, calcium, magnesium, chlorides, sulphates, nitrate, alkalinity,iron,turbidity NTU,miniral oil, colour hazen units, taste,odour,total coliform per 100 ml(microbiological test) & E coil per 100 ml(microbiological test), Arsenic & fluoride test (As per IS 10500:2012) as per norms of WHO from Reasonal Research Lab Jorhat/Defence Research Lab Tezpur or any Govt. Approved/recognized laboratory as approved by GE complete all as specified and directed. Note:- The Sample of raw water will be forwarded to the laboratory directly by the department duly sealed. The testing & Postal charge shall be borne by the contractor & report shall be submitted to the department / GE directly by the laboratory.
Supply and fixing mild steel well clamp suitable for 200mm dia MS column pipe made out of 12 mm thick MS plate fabricated to shape, including drilling holes, nuts, bolts washers etc as per IS 226:1975 complete all as specified and directed. Note(for Item No 1 to 15):- All quantity are for 2 tubewell at different locations.
Supply & fixing centering guide suitable for 150 mm dia screen pipe with sizes as per IS 2800 Part-I complete all as specified and as directed.
M/S BIJOYA LAXMI ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .