| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹20.0 L+₹2.6 L (15.0%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹21.0 L+₹3.6 L (20.8%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹21.1 L+₹3.7 L (21.0%)Rejected-Finance | L4 | Rejected-Finance Not Lowest |
Tender Value
₹20 L
Closing Date
18 Dec 2021, 6:00 pmClosed
GE Golconda
GE GOLCONDA LANGER HOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA
REPAIR REPLACEMENT MAINT OF LT EXTERNAL ELECT SUPPLY INCLUDING LT PANELS AND OTHER CONNECTING ALLIED WORKS AT ASIF NAGAR UNDER GE GOLCONDA
2021_MES_459846_3
CA No. GE/Gol/23 of 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Golconda
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Golconda
Exempted
12 Apr 2022
20 Nov 2021
21 Dec 2021
20 Nov 2021
18 Dec 2021
4 Dec 2021
20 Nov 2021 - 2 Dec 2021
Amount
M & L Pre-stressed concrete pole, 9.0metres long, 102 mm x 172 mm at top and 102 mm x 279 mm at bottom, class 10 including taking down carefully the exisitng unserviceable pole, serviceable street light fitting and ACSR conductor including connecting accessories and refixing the same after replacing the new pole with all necessary accessories complete all as specified and directed. Note: Excavaation, earthwork and PCC in foundation shall be measured and paid separately under relevant item.
M&L for PCC 1:4:8 type D2 as in foundation and mass concrete using 40 mm graded stone aggregate complete all as specified and directed.
Supply & Lay in trenches/ fixed to walls/ poles etc., testing and commissioning XLPE insulated PVC sheathed heavy duty LT 1100 Volts grade armoured UG cable with stranded aluminium conductor of size 16 Sqmm 2 core including taking out of existing cable all as specified and directed.
Ditto all as per item No 3 above but for 3.5 Core 25 Sqmm
Ditto all as per item No 3 above but for 3.5 Core 35 Sqmm
Ditto all as per item No 3 above but for 3.5 Core 50 Sqmm
Ditto all as per item No 3 above but for 3.5 Core 70 Sqmm
Ditto all as per item No 3 above but for 3.5 Core 95 Sqmm
Ditto all as per item No 3 above but for 3.5 Core 120 Sqmm
Ditto all as per item No 3 above but for 3.5 Core 150 Sqmm
Ditto all as per item No 3 above but for 3.5 Core 185 Sqmm Note for item 3 to 11 :- Earth work & excavation required shall be measured and paid separately.
S & L 100 mm bore GI tubing , light grade, with all fittings for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed.
Ditto all as per item No 12 above but for 80mm bore.
Ditto all as per item No 12 above but for 50mm bore.
S & F cable end termination jointing kit for 1.1 KV (earthed) grade cable for outdoor end termination heat shrinkable type joint with jointing material and accessories suitable for 35 to 70 Sqmm 3.5 core complete including taking out old unserviceable cable end termination jointing kit for 1.1 KV all as specified and directed.
Ditto all as per iem No. 15 above but for 95 Sqmm to 150 Sqmm 3.5 core
Ditto all as per iem No. 15 above but for 185 Sqmm to 240 Sqmm 3.5 core
S & F cable jointing kit for 1.1 KV (Earthed) grade cable for outdoor termination heat shrinkable type straight through joint with jointing material and accessories suitable for 35 sqmm to 70 sqmm 3.5 core cable complete including taking out old unserviceable one all as specified and directed.
Ditto all as per item No. 18 but for cable 95 sqmm to150 sqmm
Ditto all as per item No. 18 but for cable 180 sqmm to 240 sqmm
Supply, fixing and stringing Aluminium Conductor steel reinforced of type as directed including stretching, binding using ACSR conductor on insulator complete, on overhead line including taking down of existing conductor all as specified and directed.
Stringing only ACSR Conductor of type as directed including binding using ACSR conductor on insulator on overhead line, complete all as specified and directed .
S&F stay assembly complete with accessories as shown in electric plate No.1, stay rod 16mm dia including loop type insulator, stay clamps, and also including taking out old unserviceable one all as specified and directed. (Note: Excavation & earthwork and PCC foundation shall be measured and paid separately.)
M&L MS cross arm bracing support clamps and back plates fabricated from structural steel sections including nuts, bolts and washers welding bending cold or hot drilling holes for bolts in any shape or sizes as indicated or directed inclusive of one coat of red oxide zinc chrome primer and two coats of aluminium paint, including removing the existing cross arms etc complete all as specified and directed.
M&L Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two glavanised iron washers and one galvanised iron nut,100mm height, 65mm dia for 1100 Volts grade, including taking down existing insulators all as specifeid and directed.
M&L Shakle type, porcelain, vitreous, white brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts 100mm in height, 115mm dia, working pressure 1100 volts, section of strap 31X5, 14mm dia bolts including taking down the existing one etc complete all as specified and directed.
Cutting & trimming of tree branches any girth and size touching to overhead lines and clearing the distance 1.5 mtr either sides of overhead line removing the waste (branches etc) off the site all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation, laying of poles / cables / pipes in trenches etc and getting out in hard/dense soil complete all as directed and specified.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as all as specified and directed.
Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a lvevel not exceeding 1.5 mtrs above from the starting point complete all as all as specified and directed.
Supply and spread crushed stone sand for cushioning of cable laid in trenches complete all as specified and directed. Note:- Punned thickness will be measured for payment purpose.
M&L burnt bricks sub class ‘B’ of size 230 x 113 x 75mm for cable protection complete all as directed by Engineer-in-Charge.
M&L precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm
M & L cutting of road, hard standing of concrete or premix carpet, WBM, soiling and morrum filling for laying of cable pipe all as directed and making good the road/ hard standing by using all old/ new materials and with PCC (1:2:4) etc. complete all as specified and directed.
M&L Earthing complete with galvanized steel with plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized steel strip 32mm x 6mm dia by means of bolts, nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part-I connected to earth test point including necessary earth work and excavation in any starta, PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber with SSR Part-II RCC cover 50mm thick 1:2:4 mix type B1, using 8mm dia TMT bars reinforcement @ 140mm c/c both ways, watering funnel with water pipe GI pipe 15mm dia medium grade and protection pipe GI 40 mm dia, light grade all as specified and directed in SSR Part II. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately.
S&F PVC separators suitable for LT over head line of 4 conductors complete all as specified and directed.
M&L MCCB 415 Volts, 4 pole, fixed type, 100 Amps, with breaking capacity 16 KA complete with all connected accessories including taking out old U/S one all as specified and directed.
M&L MCCB 415 Volts, 4 pole, adjustable type, 160 Amps, with breaking capacity 36 KA complete with all connected accessories including taking out old U/S one all as specified and directed.
M&L MCCB 415 Volts, 4 pole, adjustable type, 200 Amps, with breaking capacity 36 KA complete with all connected accessories including taking out old U/S one all as specified and directed.
M&L MCCB 415 Volts, 4 pole, adjustable type, 250 Amps, with breaking capacity 36 KA complete with all connected accessories including taking out old U/S one all as specified and directed.
M&L MCCB 415 Volts, 4 pole, adjustable type, 400 Amps, with breaking capacity 36 KA complete with all connected accessories including taking out old U/S one all as specified and directed.
M&L for cleaning thoroughly LT distribution poles of any height and any description (Maximum 9 Mtr long ) with necessary cleaning agent including scrapping of old corroded paint dirt / rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing of pole coping , complete all as specified and directed .
M&L for cleaning thoroughly the two pole structure of any height and any description with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing of pole coping , complete all as specified and directed .
M&L for cleaning thoroughly the four pole structure of any height and any description with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coats aluminium paint including marking of pole numbers and colour washing of pole coping , complete all as specified and directed .
Removing Existing unserviceable Analog voltmeter with electrical connections and supply, install and test the new voltmeter 0-500V all as directed and speicified at site.
Removing Existing unserviceable Analog ammeter with electrical connections and supply, install and testing new ammeter 0-250A/100A with necessary wires all as directed and speicified at site.
Disconnecting existing panel and its connections and supply, install, testing and commissioning CPRI APPROVED factory fabricated, outdoor type, LT FEEDER PILLAR BOX made out of 3.15mm thick CRCA sheet of size 1M x 0.75M x 0.35M with projected globe roof for rainwater protection dust and vermin proof, double door with both side opening including neoprene rubber gasket, suitable for 440 Volt 3 Phase 4 Wire System, including danger plate, earthing strip point and ventilation louvers at rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc. and embeded with 50x50x6mm mild steel angle iron frame 600mm above the normal ground level complete including internal connection with suitable size of cable, cable lugs and cable glands, PCC foundation 1:4:8 (40mm graded stone aggregate) and testing after installation complete all as specified and comprising of the following :- (a) Aluminium busbar 200 amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. (b) MCCB 100 amps, 415 volt, 16 KA breaking capacity 4 pole electromagnetic release duly connected to busbar as incoming - 01 No.
S&F in repair test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hexagonal headed screws complete all as specified and directed.
S&F in repair Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, galvanised iron strip of size 32x6mm complete all as specified and directed.
S&F in repair Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, galvanised iron strip of size 25x4mm complete all as specified and directed.
S&F,in repair SS Enclosure with frame cubical type wall mounted front operated on-load changeover switch of capacity 250 Amps 415 volts, 4 pole including neccessary electric connection with suitable size aluminium lugs complete all as specified and directed.
S&F in repair SS Enclosure with frame cubical type wall mounted front operated on-load changeover switch of capacity 100 Amps 415 volts, 4 pole including neccessary electric connection with suitable size aluminium lugs complete all as specified and directed.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT, 20 x 15 cm size including taking down old plate complete all as specified and directed.
Making hole (Horizontal drilling) by suitable means for insertion of GI pipe of 50mm bore for passing cable across the road (without cutting the road) complete all as specified and directed.
M&L for surface dressing up to 15 cm in depth including cleaning of vegitation, removing grass, small plants and other unwanted material and levelling inside substations and surrounding area and removal of excavated materials at a distance not exc 50 m where directed complete all as specified and as directed.
M&L for repair of existing LT panel outddor/indoor type by properly fixing loose/dislocated MS doors complete with provision of hinges and welding at locations as necessary, provision of tower bolt as per as existing size including painting of internal and external surfaces with one coat of synthetic enamel paint of approved colour after preparation of old painted surfaces complete as required for smooth operation of panel and as directed by the Engr-in-charge (Size of Panel board n.exc 2.25x1.2x0.6 m) NOTE: MS sheet,Tower bolt,sliiding bolt wherever required will be included in the unit rate quoted by the Contractor.
MOHAMMED MUMTAZ ENGINEERING WORKS
BHAGYARAM ENTERPRISES
M/S SRIDEVI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .