Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 CrAccepted-AOC | ₹23.6 Cr Quoted ₹23.7 Cr | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹26.4 CrRejected-AOC | ₹26.4 Cr | L2 | Rejected-AOC Not being L1 Bidder |
| 3 | L3₹28.7 CrRejected-AOC | ₹28.7 Cr | L3 | Rejected-AOC Not being L1 Bidder |
| 4 | L4₹29.2 CrRejected-AOC H NO 8 2 2 1 FLAT NO 203 SITARAMA APARTMENT OPP AXIS BANK PANJAGUTTA HYDERABAD 500 082 | HYDERABAD | TELANGANA | 500082 | ₹29.2 Cr | L4 | Rejected-AOC Not being L1 Bidder |
| 5 | L5₹32.0 CrRejected-AOC K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹32.0 Cr | L5 | Rejected-AOC Not being L1 Bidder |
Tender Value
₹29.8 Cr
EMD Value
₹15 L
Closing Date
4 Oct 2024, 6:00 pmClosed
CHIEF ENGINEER, CHENNAI ZONE, ISLAND GROUNDS
HQ CE CHENNAI ZONE ISLAND GROUNDS ANNA SALAI, 600009
PROVN OF BAFFLE RANGE FOR 1 EME CENTRE AT SECUNDERABAD MIL STN
2024_MES_667777_2
89069/E8
Open Tender
Civil Works
730 days
SECUNDERABAD
As per tender notice and tender documents
7 documents required · 7 mandatory
₹3,000
Yes
GARRISON ENGINEER (MCEME) SECUNDERABAD
₹15 L
Yes
HQ CE CHENNAI ZONE
14 Nov 2024
5 Sept 2024
9 Oct 2024
5 Sept 2024
4 Oct 2024
27 Sept 2024
13 Sept 2024
Amount
Lumpsum price worked out by the tenderer for BUILDINGS / STRUCTURES as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the tenderer for EARTHWORK EXCAVATION, SITE CLEARANCE AND AREA DEVELOPMENT as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for ROAD/PATH as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for RCC COMPOUND CUM RETAINING WALL as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for RETAINING WALL - RR MASONRY as listed in Schedule ‘A’ Part-IX
Lumpsum price worked out by the tenderer for FENCING AND GATE as listed in Schedule ‘A’ Part-X
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-XI
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-XII
Lumpsum price worked out by the tenderer for RAIN WATER HARVESTING as listed in Schedule ‘A’ Part-XIII
SCHEDULE 'A' PART XIV (MISCELLANEOUS ITEMS) Note: This schedule is not pre-priced by MES
SITE CLEARANCE
INTERNAL ELECTRIC SUPPLY
Material and labour for point wiring complete all as specified with 1100 Volts grade 1.5 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including non metallic PVC rigid conduit medium grade of size 19mm dia with all accessories concealed in wall / ceiling including continous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes mounted flush with walls and modular white plate covers and frame for mounting of modular switches/sockets/fan regulators etc complete all as specified for the following:- (a) One light / fan point controlled by one switch.
All as per Sl. Item No. 15 here in before but for one three pin switch socket 6 Amps outlet on independent board.
All as per Sl. Item No. 15 here in before but for one three pin switch socket 6 Amps outlet on same board.
All as per item No 15 here in before but with cable 4 sqmm multi stranded copper FRLS wire , 1100 Volts grade, unsheathed for one 3 pin socket out let 15 amps on independent board including continuous earth wire PVC insulated 4 sqmm copper stranded conductor FRLS, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified
Supply and fixing LED luminaire Square 300 mm, 18 Watts, 220 V AC surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Material and Labour for Earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less' than 1.5meters below normal ground level, earth plate connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR-2009 (part I Specifications) connected to earth test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil and adequate quantity of common salt & charcoal for alternate layer around the earth plate, including PCC (1:2:4) pit and 10mm thick C.I. cover with arrangement of hinge to 40x40x6mm C.I. angle iron frame, including 20mm dia G.I. pipe for watering purpose with the arrangement of funel and wire mess, including GI pipe of 15 dia for earth lead protection complete all as specified and as directed. Note :- The rate is deemed to be inclusive of the cost of earth work, excavation on any type soil and removal of surplus soil to a distance of 50 Mtrs, PCC 1:2:4 type B1 for earth pit cover 6 Nos 8 mm dia TMT bar on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, GI Wire length up to 7.50M will be measured as one unit)
ROAD/ PATH/ CULVERT
Material and Labour for Painting lines, dashes, arrows, letters etc. on road surfaces / over speed breakers, pavements and the like exc 10 cm and n. exc 30 cm wide with 2 to 3mm thick thermoplastic road marking paint using automatic road marking spray machine including preparing black top surface by fanning out dust and any other foreign matter complete all as specified and directed.
Supply and Fix Solar Stud AK - 970 of Aktion make pasted on bituminous / concrete surfaces with adhesive as per manufacturer's instructions complete all as directed.
Supply and Fix Road cat eyes duly fixed with approved adhesive as per manufacturers instructions complete all as specified and as directed.
Material and Labour for rubber based speed bumps of dimensions 500x420x75mm with reflective arrow stickers on both side with combination of approved colours (black and yellow) fixed with necessary bolts etc., complete all as specified and as directed.
Supply and Fix Convex mirror of 1000 mm dia made of poly carbonate material fix to 100mm dia MS post 50mm nominal bore and of wall thickness 3.65mm conforming to IS-1161-1979 of grade St-240 of 3 metre long including two coats of epoxy paint and including necessary earth work and execation in post holes and PCC bed block 1:2:4 type B1(using 20mm size graded stone aggregates) of size 450x450x600 mm, including removal of surplus soil and levelling of distrubed ground complete all as specified and directed.
COMPOUND WALL/ GATE
Material and Labour for 4 mm thick PVC sheet of any colour fixed to concrete/masonry surfaces with CP screws and washers all as directed by Eingineer - in - Charge.
EXTERNAL WATER SUPPLY
Material and Labour for cutting the existing CI pipe 100 mm dia bore in position for insertion of new tee 100 x 100 x 50mm dia bore suitable to connect GI pipe 50 mm bore and jointing complete all as specified and directed Note: The rate quoted shall inclusive of all CI fittings & joints. Excavation and earth work measured and paid seperately under relevant items.
Supply and fix Gun metal Foot valve confirming to IS 4038, 50 mm dia complete all as specified and directed
Material and Labour for construction of valve chamber 60x60x60 cm inner dimensions, brick masonry in cm 1:4 PCC base in 1:3:6 of 7.5 cm thick & plastering 15 cm thick in CM 1:4 in inner side/ coping of all chamber fabrication of Iron frame 40x40x6 mm size angle iron MS cover 3 mm thick with hinges and locking arrangements painting of steel surfaces with one coat of zinc chrome primer and two coats of epoxy paint including necessary earth work, returning and refilling etc all as specified and as directed.
Supply and fix DOL starter 3 phase 50 Hz for Mono block pump set 2 HP complete all as specified and directed
Supply install and testing of Monoblock pumpset suitable for three phase 50 Hz system having capacity 2 HP, Cast Iron body and impellor, carbon steel shaft suitable for 20 m head and not less than 3.9 LPS complete all as specified and directed. Note: Rate quoted shall inclusive of the cost of necessary foundation and suitable electrical connection from starter panel to pump set.
EXTERNAL ELECTRIC SUPPLY
Material and Labour for earthing of machinery/equipment Installed at power house/substation complete using galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to galvanized iron strip 32x 6 mm as earthing lead by means of bolts, nuts and washers made out of GI/steel earth strip protected by GI light grade pipe of 40 mm dia and connecting to main panel board/switch board/control board all as shown in electrical plate No 3 of SSR Pt I incl PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10 cm center to center both ways incl earth work like excavation, returning filling back disposal etc complete. Note :- The rate is deemed to be inclusive of the cost of earth work, excavation on any type soil and removal of surplus soil to a distance of 50 Mtrs, PCC 1:2:4 type B1 for earth pit cover 6 Nos 8 mm dia TMT bar on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, GI Wire length up to 7.50M will be measured as one unit)
Design, fabrication, supply, installation, testing and commissioning of CPRI tested/OEM tested Feeder pillar box of outdoor cubicle type with approximate sizes made up of mild steel 3 mm outer sheet with necesary canopy and angle iron frame with angles 45mm x 45mm x 5mm, with suitable inner compartments / enclosures of 2 mm thick MS sheet, front operated doors, double shuttered, with locking arrangement, dust and vermin proof, to minimum IP 65 protection class, epoxy powder coated, LT, 415 volts, 3 Phase, 4 wire, 50 cycles suitable for housing and including provision of the following components, internal wiring complete all as specified and directed
(a) Aluminium bus bar with rating 200 Amps 3 phase and 200 Amps for neutral with PVC coloured sleeves - 01 Set (b) MCCB 100 Amps, 4 pole, 25 kA with fixed thermal magnetic setting - 01 No (Incoming). (c) MCCB FP 63 Amp 16 KA- 01 Nos (d) MCCB FP 40 Amp 16 KA- 04 Nos (Simulator room, Guard room, security light, charging panel). (e) MCB 32 Amps,SPN, 10 kA - 04 No (Outgoing to various bldg). (f) Astronomical Digital Timer with suitable capacity 3 phase contactor - 01 Nos (g) Digital Ammeter with suitable CTs, Digital voltmeter, Indicating lamps- 01 Set
Design, fabrication, supply, installation, testing and commissioning of CPRI tested/OEM tested Feeder pillar box of outdoor cubical type with approximate sizes made up of mild steel 3 mm outer sheet with necesary canopy and angle iron frame with angles 45mm x 45mm x 5mm, with suitable inner compartments / enclosures of 2 mm thick MS sheet, front operated doors, double shuttered, with locking arrangement, dust and vermin proof, to minimum IP 65 protection class, epoxy powder coated, LT, 415 volts, 3 Phase, 4 wire, 50 cycles suitable for housing and including provision of the following components internal wiring complete all as specified and directed
(a) Aluminium bus bar with rating 200 Amps 3 phase and 200 Amps for neutral with PVC coloured sleeves - 01 Set (b) MCCB 63 Amps, 4 pole, 25 kA with fixed thermal magnetic setting - 01 No (Incoming). (c) MCCB 40 Amps, 4 pole, 16 kA with fixed thermal magnetic setting - 03 No (d) MCB 32 Amps,SPN, 10 kA - 04 No (Outgoing to various bldg). (e) Astronomical Digital Timer with suitable capacity 3 phase contactor - 01 Nos (f) Digital voltmeter, Indicating lamps- 01 Set
Design, fabrication, supply, installation, testing and commissioning of CPRI tested/ OEM tested Feeder pillar box of outdoor cubical type with approximate sizes made up of mild steel 3 mm outer sheet with necesary canopy and angle iron frame with angles 45mm x 45mm x 5mm, with suitable inner compartments / enclosures of 2 mm thick MS sheet, front operated doors, double shuttered, with locking arrangement, dust and vermin proof, to minimum IP 65 protection class, epoxy powder coated, LT, 415 volts, 3 Phase, 4 wire, 50 cycles suitable for housing and including provision of the following components all wiring included all as specified and directed. (for target Charging Panel No 1 and 2)
(a) Aluminium bus bar with rating 100 Amps 1 phase and 100 Amps for neutral with PVC coloured sleeves - 01 Set (b) MCCB 40 Amps, FP, 16 kA - 01 No (Incoming). (c) Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp Modular type universal - 05 No
Material and Labour Pipe bracket for street light fitting made out of 40mm dia GI pipe, medium grade, tubing bend to shape, 1.5m long fixed to pole wall including provn of two sets of clamps made out of flat iron of size 25x4 mm including of provn of bolts, nuts and washers complete all as specified and directed.
Supply and fix junction box thermoplastic body for street light pole with locking arrangement with IP -66 protection, size 205 x 255x112 with 32 Amp 4 way heavy duty terminal block with 6 Amp MCB SP along with suitable cable glands and two steel bracket to fix with pole complete.
DG SET
Supply, install, test and commissioning of silent Diesel Engine Generating set 415 volts, 3 phase, 4 wire engine as per IS : 10001/10002 conforming to Latest CPCB Norms , and alternator as per IS : 13364 of capacity 30 KVA/ 24 KW at site complete with control panel having meters, sound proof canopy etc including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure :- Note for BOQ No.39.00 :- The capacity of generator set shall be net after all de-rating factor as per relavent IS design). AC Generator should be suitable for ambient conditions at Secunderabad and confirming to IS.
(A) Alternator :- Standard design alternator rated at (20 KW) net output at site after considering all de-rating factors, site conditions and at power factor 0.8, AC, 3 phase 4 wire, 415 V, 50 Cycles/Second, 1500 RPM self excited, self regulated, screen protected, drip proof IP 23 enclosure, brush less design, voltage regulation ± 2.5 %.
(B) Diesel Engine :- Vertical diesel engine of suitable capacity, water cooled, closed circuit as per BS-649 or IS-1002 direct injuction type . Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running 24 hrs continuously with 10% over loading for 01 hour in every 12 hours as per BS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection and equipped with all standard fitting as per manufacture's recommendations and mounted on common base frame with following Specifications :-
(i) Fly wheel with housing :- Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturer's instructions (ii) Cooling system :- (a) Mounted radiator with fan & belts & guard, rubber hoses and thermostat. (b) Cooling water pump centrifugal type . " (iii) Governer :- Electronic Governer. (iv) Electric Starting System :- Electric Self starter, 12 volts DC (12 volt, 100 AH battery 1 No's) charging alternator as per manufacturer's design, copper leads with lugs of adequate size complete with initial charging of maintenance free battery 1x12 volt 100 AH capacity.
(v) Generator Monitoring Panel :- Comprising of following :- (a) Microprocessor based genset controller for metering, monitoring, governing and protection (b) Engine protection for low lub oil pressure, high coolant temperature (Alarm & Shutdown) (c) Alternator protection parameters like under voltage, over current, under frequency, over frequency (Alarm & Shut down) (vi) Accessories :- AVM Pads built or separately mounted to manufacturer base frames. (vii) Coupling Arrangements :- Fixed coupling, flywheel to suit fixed coupling and fly wheel housing. (viii) Exhaust System :- Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbetos rope of suitable size and complete design should be as per latest emission norms of GOI complete all as directed. (ix) Fuel Tank :- Daily service fuel tank of capacity suitable for 12 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturer's design.
(C) Acoustic Enclosure (Sound Proof Canopy) :- All as per Latest CPCB norms and OEM of DG Set's design. (D) AMF Panel :- Supply, install, testing and commissioning of AMF Panel outdoor type, cubical body, dust and vermin proof made up of CRCA sheet 3 mm thick painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to IP 45 with front and rear opening with louvers and mounted on floor with PCC pedastal pillars with a clearence of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories :- (i) PLC - 01 No (ii) Power Contactor heavy duty suitable for generator and mains (iii) Over load relay for genset (iv) Suitable rating isolating switch MCCB for both DG & main supply. (v) On Load changeover (as mentiones in Sub para - xiv here-in-after) (vi) Multi functioning meter to indicate voltage, current, frequency, PF, KW & KWH etc (vii) Emergency stop push button. (viii) Set of indicaters :- (a) Low lube oil pressure (b) DG Set over load
(E) Civil Works:- All civil works related to foundation, installation of panel and equipment and depth of foundation shall be minimum 300mm with antivibration pads, or as recommended by the manufacturers. Cables from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. (F) (i) The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department. (ii) The testing of Genset for continuos 12 Hours shall be done by an officer detailed by accepting officer after installation at site No load - 1/2 Hour 25% load - 1/2 Hour 50% load - 1 Hour 75% load - 1 Hour 100% load - 8 Hours 110% load - 1 Hour
Supply, installation, testing and commisssioning (SITC) of Smart Target 10 Lane System based on acoustical projectile detecting and reporting automatically comprising the following key deliverables all as specified in Particular specifications and all as directed:- (a) Pop Up Motors with targets - 10 Nos (b) Illumination Lamp - 10 Nos (c) Strobe Lamp - 10 Nos (d) Sensing Frame - 10 Nos (e) SDU - 10 Nos (f) FPE wih sofware - 10 nos (g) MCS with software - 01 No (h) Wireless communication setup - 01 No (j) Batteries and chargers - 01 Set Make shall be as approved by GE
Supply and laying 180mm dia (nominal size) DWC HDPE SN-8 pipes confirming to IS 14930 part-2 / IS 16025 Part-24 including all necessary specials, cutting and jointing as specified and directed.
Supply, lay/ spread in trenches riddled sand as specified in IS: 1255 for cushioning of cable to the full width of excavated trench, 8cm thick before laying cable and 15cm thick above the cable, gently punned down after stretching and testing of cable on transformer yard, etc., complete all as specified and as directed. Note : Punned thickness will only be considered for payment.
BEKEM Infra Projects Private Limited (BID ID -3128274)
Sri Raghava Constructions Ltd (BID ID -3127423)
SHRADHA SABOORI PROJECTS INDIA PRIVATE LIMITED (BID ID -3124486)
SOOD ASSOCIATES PVT LTD (BID ID -3128286)
TRIVENI CONSTRUCTIONS (BID ID -3128004)
N R Constructions (BID ID -3124712)
SVS PROJECTS (BID ID -3127997)
R. Wadhumal and Sons (BID ID -3127876)
Sukhdevraj Sharma Engineers & Contractors Pvt Ltd (BID ID -3126614)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid