Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹36.9 L+₹66,019.83 (1.82%)Rejected-Finance | L2 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 3 | L3₹37.1 L+₹88,253.82 (2.44%)Rejected-Finance | L3 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 4 | L4₹37.3 L+₹1.1 L (2.92%)Rejected-Finance | L4 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 5 | L5₹37.4 L+₹1.2 L (3.21%)Rejected-Finance | L5 | Rejected-Finance HIGHER THEN L1 BIDDER |
| Sl No | Description | Qty | Unit | Darjeeling Enterprises L2 | JALAPAHAR HARDWARE L3 | TSHERING WANGYAL BHUTIA L4 | RAI CONSTRUCTION L1 | BIMAL BHATTRAI L5 | BHASKAR PRADHAN L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down cement or cement lime plaster, any description on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. | 280 | Sq.m | 95 ₹26,600 Lowest | 97 ₹27,160 | 95 ₹26,600 Lowest | 100 ₹28,000 | 95 ₹26,600 Lowest | 105 ₹29,400 |
| 2.00 | M&L for rendering 20mm thick (two layer, 10mm and 10mm thick) in cement mortar (1:4) with water proofing compound @ 3% by weight of cement in second layer or in the manner specified by the manufacturer and in the proportions indicated on fair faces of brick work or concrete surfaces, finished even and fair (without using extra lime or cement), complete all as specified and directed.
Note: Water proofing compound will be measured and paid separately | 170 | Sq.m | 390 ₹66,300 | 385 ₹65,450 | 376 ₹63,920 Lowest | 380 ₹64,600 | 420 ₹71,400 | 390 ₹66,300 |
| 3.00 | M&L for rendering 15mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra lime or cement), complete all as specified and directed. | 280 | Sq.m | 325 ₹91,000 | 312 ₹87,360 | 303 ₹84,840 | 300 ₹84,000 Lowest | 350 ₹98,000 | 320 ₹89,600 |
| 4.00 | Supply only integral water proofing compond, all as specified and directed. | 15 | Kg | 56 ₹840 | 50 ₹750 Lowest | 62 ₹930 | 55 ₹825 | 50.5 ₹757.5 | 50 ₹750 Lowest |
| 5.00 | M&L for preparation of new plastered or unplastered surface of wall and applying two coats of distemper oil emulsion (OBD), over a coat of priming coat (Chalk whiting, on plastered surfaces, prepara-tory to distempering), complete all as specified and directed. | 280 | Sq.m | 95 ₹26,600 Lowest | 100 ₹28,000 | 99 ₹27,720 | 98 ₹27,440 | 115 ₹32,200 | 110 ₹30,800 |
| 6.00 | M&L for preparation of newly plastered surface of wall and applying two coats of exterior weather coat paint over a coat of alkali resistant primer, complete all as specified and directed. | 170 | Sq.m | 220 ₹37,400 | 210 ₹35,700 | 148 ₹25,160 Lowest | 200 ₹34,000 | 215 ₹36,550 | 210 ₹35,700 |
| 7.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. | 282.36 | Sq.m | 55 ₹15,529.8 Lowest | 55 ₹15,529.8 Lowest | 57 ₹16,094.52 | 60 ₹16,941.6 | 55.75 ₹15,741.57 | 55 ₹15,529.8 Lowest |
| 8.00 | M&L for 25mm thick plain cement concrete(1:2:4), type B-0, (using 12.5mm graded stone aggregate) as in sub-base, sub-floors, floors, pavings, roof treatment etc. and finishing the surface rough to receive screed bed, complete all as specified and directed. | 40 | Sq.m | 660 ₹26,400 | 700 ₹28,000 | 784 ₹31,360 | 650 ₹26,000 Lowest | 675 ₹27,000 | 700 ₹28,000 |
| 9.00 | M&L for glazed ceramic colouered tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick as in vertical surface such as risers of steps, skirting, dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 10 mm thick rendering in cement mortar (1:3) finished even and rough, complete all as specified and directed. | 124 | Sq.m | 1,628 ₹2,01,872 | 1,650 ₹2,04,600 | 1,634 ₹2,02,616 | 1,620 ₹2,00,880 Lowest | 1,650 ₹2,04,600 | 1,650 ₹2,04,600 |
| 10.00 | M&L for machine cut Kota stone slab flooring, 20 to 25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing and exposed edges of Kota stone shall be rounded complete over and including 20 mm thick screed bed or bedding layer in cement mortar (1:6) finished even and rough, complete all as specified and directed. | 120.36 | Sq.m | 1,858 ₹2,23,628.88 | 1,860 ₹2,23,869.6 | 1,835 ₹2,20,860.6 Lowest | 1,850 ₹2,22,666 | 1,900 ₹2,28,684 | 1,860 ₹2,23,869.6 |
Tender Value
₹34.7 L
EMD Value
₹69,500
Closing Date
17 Jul 2025, 6:00 pmClosed
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
SPECIAL REPAIR TO BUILDING NO P-35 AND 35A COOK HOUSE AT JALAPAHAR UNDER AGE (I) DARJEELING
2025_MES_714378_1
CWE/136-WE/09 OF 2025-26
Open Tender
Civil Works
Item Rate
240 days
Darjeeling
Class D, Category a(i)
8 documents required · 8 mandatory
₹500
AGE(I) Darjeeling
₹69,500
Yes
11 Sept 2025
14 Jun 2025
18 Jul 2025
14 Jun 2025
17 Jul 2025
1 Jul 2025
14 Jun 2025 - 21 Jun 2025
Amount
Taking down cement or cement lime plaster, any description on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
M&L for rendering 20mm thick (two layer, 10mm and 10mm thick) in cement mortar (1:4) with water proofing compound @ 3% by weight of cement in second layer or in the manner specified by the manufacturer and in the proportions indicated on fair faces of brick work or concrete surfaces, finished even and fair (without using extra lime or cement), complete all as specified and directed. Note: Water proofing compound will be measured and paid separately
M&L for rendering 15mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra lime or cement), complete all as specified and directed.
Supply only integral water proofing compond, all as specified and directed.
M&L for preparation of new plastered or unplastered surface of wall and applying two coats of distemper oil emulsion (OBD), over a coat of priming coat (Chalk whiting, on plastered surfaces, prepara-tory to distempering), complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of exterior weather coat paint over a coat of alkali resistant primer, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L for 25mm thick plain cement concrete(1:2:4), type B-0, (using 12.5mm graded stone aggregate) as in sub-base, sub-floors, floors, pavings, roof treatment etc. and finishing the surface rough to receive screed bed, complete all as specified and directed.
M&L for glazed ceramic colouered tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick as in vertical surface such as risers of steps, skirting, dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 10 mm thick rendering in cement mortar (1:3) finished even and rough, complete all as specified and directed.
M&L for machine cut Kota stone slab flooring, 20 to 25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing and exposed edges of Kota stone shall be rounded complete over and including 20 mm thick screed bed or bedding layer in cement mortar (1:6) finished even and rough, complete all as specified and directed.
M&L for machine cut Kota stone slab as in vertical surfaces such as dado/skirting, 20 to 25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing and exposed edges of Kota stone shall be rounded complete over and including 10 mm thick rendering in cement mortar (1:4) finished even and rough, complete all as specified and directed.
M&L for granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete including screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in cement mortar (1:6), complete all as specified and directed.
Demolition of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete all as specified and directed
S&F of aluminium anodised snap grid frame work of size 605mm X 605mm framework for ceiling with aluminium tee section of size 23.5mm X 26.4mm X 1.4mm thick and aluminium angle section of size 36.5mm X 25mm X 1.4mm thick, for false ceiling incl Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40X3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long incl 4mm thick non asbestos E-board, HSPC fixed to frame, complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed
M&L for reinforced cement concrete (nominal mix) (1:2:4), type B1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), rough finished surfaces of concrete on flat surface, complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
M&L for brickwork with fly ash bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6), complete all as specified and directed.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar (1:4), complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
S&F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
S&F of pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
Taking up or down 15 mm bore old steel tubing and connections, including cleaning for refixing or removal to store or removal unserviceable pipe from site, complete all as specified and directed.
S&F of 15 mm bore tubes 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Taking up or down 20 mm bore old steel tubing and connections, including cleaning for refixing or removal to store or removal unserviceable pipe from site, complete all as specified and directed.
S&F of 20 mm bore tubes 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth on stone walls, complete all as specified and directed.
S&F in repairs of Wall Mixturer with non-telephonic chromium plated cast copper with approved make CP alloy with crutch or butterfly handle screwed for iron pipe or for brass ferrule, of fixed 15mm dia., complete all as specified and directed
S&F in repair of 15mm bore dia bib taps, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
S&F in repairs angle , stop valve 15 mm bore, (Concealed type) chromium plated, with wall flange, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions long shank and fixed complete all as specified and directed.
S&F PVC waste pipe 32mm dia suitable length for WHB/Sink all as specified and directed.
S&F of 1mm thick stainless steel sink with drainage board kitchen or laboratory type with waste pipe, plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size of sink 915mm x 460mm and bowl size 410mm x 330mm x 160mm, complete all as specified and directed.
Dismantling water tanks of capacity exc 1000 & n.exc 2000 ltrs in any position etc all as specified and directed.
S&F of rotational moulded polyethylene water storage tanks of capacity 2000 litres (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-l and directed.
Supplied and fixed of 20 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
S&F of 20 mm dia Ball valves, high pressure with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed.
S&F of 110mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed.
S&F of PVC (SWR) pipes single socketed 110mm bore, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
S&F of 75mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed.
S&F of PVC (SWR) pipes single socketed 75mm bore, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
S&F of 110mm bore PVC (SWR) junction single, (Single T) equal or unequal including jointing with solvent cement, complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) bend any radius with access door complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) bend any radius with access door complete all as specified and directed.
S&F of 100mm dia stack clamps out of 50mmx5mm flat iron and 16mm dia round iron stays including bolts and nuts and securing ends of stays to wall or roof all as specified and directed.
M&L for 75 mm diameter of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thickness (below or above ground level), complete all as specified and directed.
M&L for providing cement concrete (1:2:4), type B-0, (using 12.5 mm graded aggregate) as in coping /parepet wall/bed plate /Kerb stone etc. with plain fair faces including chamfers, weathering, slightly rounded or chamfered angles and throating, including necessary form work, complete all as specified and directed.
M&L for 75 mm thick plain cement concrete(1:3:6), type C2 (40 mm graded stone aggregate) as in flooring, plinth protection, hard standing, path etc including finish the surface even and smooth with using extra cement, complete all as specified and directed.
M&L for forming 12mm thick expansion joint filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade 'B' for 75mm thick slab, complete all as specified and as directed.
M&L for 100mm thick plain cement concrete (1:4:8), type D2 (using 40mm graded stone aggregate) as in sub-base, sub-floors, floors, pavings etc., all as specified and as directed.
M&L for coloured & polished chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and no pigments includig 20mm thick screed bed in cement mortar (1:4), complete all as specified and directed.
M&L hard core of gauge n'exc 63 mm of broken boulder deposited spread and levelled in layers n exc 15cm thick ,watered and rammed to a true surface.
Taking down chowkhats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frame), complete all as specified and directed.
Taking down chowkats or frame not 1.5 sqm but n.exc 4 sqm with shutter (with out taking off shutter from frame) all as specified and removing from site and as directed.
S&F of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
S&F of rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410 -W (Gde- E- 250) quality- A, all as specified and directed.
S&F of pressed steel frame of size 105 x 60mm for door with one or more rebates including necessary fixing, lugs, hinges,lock, strike plate, etc., complete all as specified and directed.
S&F 35mm thick 2nd class hardwood rail and style Factory made plain frames, panelled shutter (two panel) with lock rail and panel of 9mm B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (part-1), kiln seasoned and chemically treated : supplied and fitted to chowkhats, complete all as specified and directed.
M&L for 12 mm thick prelaminated particle board for cupboard shelf, interior grade, prelimated one sides with decorative choice lamination & other side balancing white lamination and fixed with screws to timber frame work including teakwood lipping 6 mm thick fixed with nails, complete all as specified and directed.
M&L in repairs 18/19 mm thick prelaminated particle board for cupboard shutter, exterior grade, prelimated one sides with decorative choice lamination & other side balancing white lamination and fixed with screws to iron frame work including teakwood lipping 6 mm thick fixed with nails, complete all as specified and directed.
S&F of 100mm size hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws, all as specified and directed.
M&L for 2nd class hardwood in plain fillets, square rectangular or traingular in section, clean sawn, secured with nails or brads sectional area not exc 3 sqcm, complete all as specified and directed.
S&F of anodised aluminium powder coated (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and directed
S&F of anodised aluminium powder coated of any colour (minimum thickness of powder coating 50 micron) window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc., complete all as specified and directed.
S&F of anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @200mm center to center, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.
S&F of 4.8mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and directed.
S&F of 100mm size butt hinges, medium weight, cold rolled mild steel, and fixed, all as specified and directed.
S&F of 75mm size butt hinges, medium weight, cold rolled mild steel, and fixed, all as specified and directed.
S&F of 150 mm size aluminium handles, cast type, anodised, all as specified and directed.
S&F of 100 mm size aluminium handles, cast type, anodised, all as specified and directed.
S&F of 200mm long aluminium anodised, barrel tower bolts of extruded section and fixed, all as specified and directed.
S&F of 125mm long aluminium anodised, barrel tower bolts of extruded section and fixed, all as specified and directed.
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M&L for mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
S&F of 20 mm thick, second class hard wood boarding clean sawn, planed one side with butt joints and fixed with nails in any situation as in eaves board, etc complete all as specified and directed.
S&F PVC (SWR) half round gutter drain pipe 180mm bore complete all as specified and directed.
S&F 180mm PVC (SWR) joint socket as in gutter drain pipe complete all as specified and directed.
S&F 180mm PVC (SWR) joint tee with end cap as in gutter drain pipe complete all as specified and directed.
S&F 180mm PVC (SWR) pipe clamp complete all as specified and all as specified and directed.
S&F rain water drainage pipes PVC(SWR) pipes single socketed 110mm bore in any length with rubber rings joints fixed to walls all as specified and directed.
S&F PVC (SWR) bends for 110mm bore any radius complete all as specified and as directed
M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in bed blocks for grouting hold fasts, coping, filling in pressed steel chowkat or similar work including necessary form work as required, complete all as specified and directed.
M&L for plain cement concrete(1:3:6), type C-2 (40 mm graded stone aggregate) in surface channels and drains including all necessary form work, complete all as specified and directed.
Excavation in post holes (or similar holes) in hard rock, each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface, complete all as specified and directed.
M&L for plain cement concrete (1:3:6), type C2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and as directed.
Dismantling of old decayed timber scantling 40 Sq cm and over in section in any position unframed work including removing of dismantled material from work site all as directed.
Dismentling of fillets rails etc under 40 sqcm in section (framed work), complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds mitered / stopped ends etc all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light,fan,socket or power) complete fittings such as switches,ceiling roses, pendents, regulators, sockets,etc (excluding Light Fitting), removing materials from site and making good disturbed surface of walls & floors etc., complete all as specified and directed.
Taking down DB's including MCB's etc., complete all as specified and directed.
Taking down carefully unserviceable sub main wiring of any size/core/type including making good the disturbed surfaces, complete all as specified and directed.
M&L for Point wiring with PVC un-sheathed and PVC insulated cable with stranded copper conductor cable 1.5 Sq mm size in and including PVC casing caping double lock type of required (20/25/32) including one No. 1.5 Sq mm single core PVC insulated copper cable for continuous earth wire connected to earth dolly for one light /Bell point controlled by one 5 Amp switch one way and sharing of wire in casing capping shall be as per IS specification including making good disturbed surface of walls & floors etc., complete all as specified and directed.
M&L for point wiring with 1.5 Sq.mm (nominal area) PVC insulated sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC conduit not less than 20mm dia (concealed), medium grade with all necessary fittings, concealed wiring for light / Fan / Bell on independent board, point controlled by one switch including 1.5 Sq mm PVC FRLSH insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.60 mm thick pressed steel terminal boxes including flush metal box 2/4/6/8/12 module with module inner and outer plates for mounting moduler switches, socket outlet, regulator etc. with 3 mm thick laminated bakelite sheet cover for housing switches, socket outlet, regulator etc., complete all as specified and directed including testing on completion. Notes: (a) Proper colour coding of PVC insulated copper wire should be maintained as red/yellow/blue wires for phases, black wire for neutral and green wire for earth. (b) Two run of 1.5 Sq.mm for phase and neutral and one run of 1.5 Sq.mm for earth wire. (c) Concealed type in permanent bldg and surface type in temporary bldg or as directed.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring , for one 3 pin socket outlet, 5 Amps on independent board, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring , for one 3 pin socket outlet, 5 Amps on the same board with other switches, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
Material and labour for point wiring with 2.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 25mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring , for one 6 pin socket outlet, 15 Amps on independent board, with 2.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
S & F in repairs Switch Piano, flush type, single pole, one way, 5 Amps, 230 Volts complete all as specified and as directed.
S &L for ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body, three terminal, 240 Volts, all as specified and directed.
S &L for socket outlet 2 in 1, 3 pin, 5/6 Amp flush type, 240 Volts, all as specified and directed.
S &L for switch socket combination 2 in 1, 5/6 Amps 5 pin multipurpose flush type, 240 Volts, all as specified and directed.
S&F of switch socket combination 5 in 1, 6 Pin, 6Amps / 16Amps, 6 pin multipurpose flush type universal, complete all as specified and directed.
S&F in repairs wall mounted LED tube light fittings 20 Watts 6500K including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fittings in position at site on 02 Nos new round blocks, complete all as specified and directed. Make: Crompton Greaves (Cat No.- CCS-100-20-65-HL2-DP-NWH), Bajaj (Cat No.- BCLAB 20W WH LED P), Havells (Cat No.- ENDURALINEARNEOBS20WLED865SPCSS) or equivalent model of approved make as per tender documents.
S&F LED Building Security light fitting 30 watt complete with fixing arrangements all as specified and directed. (Cat Part No. -ENDURAPEARLSL30WLED757SASYTOPCMP of Make Havells or equivalent model of Philips/CG/ Bajaj etc.)
S&F of sub main wiring with two single core 6.0 Sqmm PVC (FRLSH) copper conductor, insulated multistranded flexible copper conductor cable 600/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 6.0 Sqm single core single strand copper conmductor as continous earth wire in green colour connected to common earth dolly all as specified and directed. (Note:- Two runs of 6.0 sqmm PVC FRLSH copper conductor, one run of earth wire, one run of PVC casing capping shall be measured as one unit length).
Supply and fixing of sheet metal enclousers for DB's with MCB incomer suitable for triple pole and neutral (TPN), double door, 4 Ways, built-in 200 Amps busbar for neutral link suitable for 415 Volts, AC, 50 Hz, inculding fixing on suitable rectangular wooden boxs complete all as specified and as directed.
Supply and fixing of sheet metal enclosure, double door for MCB single pole & neutral DB's, 8 way with 200 amps rated bus bar suitable for 240 Volt, AC, 50Hz, including fixing on suitable rectangular wooden block complete all as specified and directed. Make : Legrand, Schneider, Siemens or equivalent.
Supply and fixing in repair of 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole & neutral (SPN) and current carrying capacity of 32 Amps in the MCB DB complete with connection testing and commissioning, all as specified and directed. Make : Legrand, Schneider, Siemens or equivalent.
Supply and fixing of 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole & neutral (SPN) and current carrying capacity of 5 to 32 Amps in the MCB DB complete with connection testing and commissioning, all as specified and directed. Make : Legrand, Schneider, Siemens or equivalent.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of triple pole and neutral(TPN) and current carrying capacity 40 to 100 Amps, in the DB complete with connection testing and commissioning, complete all as specified and directed.
M & L for commercial kitchen Stainless Steen chimney hood, chimney Filter three nos with good finish and size including GI Ducting line and heavy duty exhaust blower fan and civil wirk like cutting holes into or through brick walls built in mud mortaar and making good in cement mortor 1:3 or cement concrete 1:2:4 type B-1 as required making opening in wall for exhaust ventilator of duct complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm × 60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron or steel earth lead wire 4.0mm dia size by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR Part-I, connected to earthing test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil, GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of earth wire etc. upto test point, PCC (1:3:6) chamber with RCC cover in cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with 8mm dia TMT bar 15cm C/C and suitable handle of 10mm dia round bar, funnel, wire mesh, charcoal dust, salt etc., connected to DB as indicated, complete all as specified and as directed. Notes: Contractor should conduct necessary test such as earth continuity, earth resistance test in presence of Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, under groung cables etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil, all as specified and directed.
Returning filling in soft / loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed.
Removal of surplus excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point, complete all as specified and directed.
M&L for sand cushioning to under ground cable in layers of 23cm thick (8 cm before laying the cable and 15 cm thick after laying the cable) in trenches complete all as specified and directed. Note :-Puned layers of 18 cm thick sand shall measured only.
Supply and laying of old size burnt clay fly ash building bricks designation 75(Kg/cm2) laid flat equal to width of bricks, perpendicular to under ground (UG) cable over the dry sand cushioning, for cable protection, complete all as specified and directed.
M&L for 40mm dia steel tubes (light grade) galvanised with all fittings, laid in trenches/wall/pole/road crossing for protection of underground cable/ earth strip, all as specified and directed.
Supply, Laying & testing cable XLPE insulated screened PVC beded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 3.5 core 35 Sqmm, complete all as specified and directed.
S&F of GI tubing of 25 mm dia medium grade ISI Marked laid in trenches/laid under floor on ground including all fittings such as elbow, union, reducer, tees, bends etc and short length, complete all as specified and directed.
Supply and laying testing steel water tubing medium grade with all fitting fixed to wall/ceiling or laid in floor of size 25 mm bore all as specified and directed. Make : TATA/Jindal/Bansal.
Cutting existing steel tubing of size 25 or 32 for alterations or additions (Each cut measured) and screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector), necessarily done in position without taking down, complete all as specified and directed.
S&F Gun-metal, globe or gate valves, ISI marked, 25mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed
Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and general condition of contracts before entry / quoting the rates. Note 2:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
Darjeeling Enterprises (BID ID -3353621)
JALAPAHAR HARDWARE (BID ID -3353660)
TSHERING WANGYAL BHUTIA (BID ID -3352043)
BIMAL BHATTRAI (BID ID -3353551)
BHASKAR PRADHAN (BID ID -3352702)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .