Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹19.2 L | L1 | Accepted-Finance lowest bidder |
| 2 | L2₹19.9 L+₹63,384 (3.30%)Rejected-Finance | ₹19.9 L+₹63,384 (3.30%) | L2 | Rejected-Finance Other Than lowest bidder |
| 3 | L3₹21.9 L+₹2.6 L (13.7%)Rejected-Finance | ₹21.9 L+₹2.6 L (13.7%) | L3 | Rejected-Finance Other Than lowest bidder |
| 4 | L4₹22.2 L+₹3.0 L (15.5%)Rejected-Finance | ₹22.2 L+₹3.0 L (15.5%) | L4 | Rejected-Finance Other Than lowest bidder |
| 5 | L5₹22.7 L+₹3.5 L (18.0%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | ₹22.7 L+₹3.5 L (18.0%) | L5 | Rejected-Finance Other Than lowest bidder |
| Sl No | Description | Qty | Unit | NEETU TRADERS (INDIA) L7 | M/s S.G. BUILDERS L4 | Shiv Enterprises L1 | M/s Krishna Construction Co. L5 | Ruchi enterprises L10 | PARMAR ENTERPRISES L3 | GILL ENGINEERS L2 | R S ENGINEERS L9 | R B ENTERPRISES L8 | M/s Naresh Kumar Gupta & Co. L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper / aluminium point wiring (light / fan/ socket or power) complete including fittings and ficutre such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces all as specified and directed. | 2,003 | Per point | 5 ₹10,015 | 1 ₹2,003 Lowest | 1 ₹2,003 Lowest | 2 ₹4,006 | 1 ₹2,003 Lowest | 9 ₹18,027 | 5 ₹10,015 | 5 ₹10,015 | 1.99 ₹3,985.97 | 8 ₹16,024 |
| 2.00 | Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of same size ie.1.5 Sqmm and connected to common earth and earth dolly with suitable copper lugs and drawing into existing conduit and replacement of modular metal flush box of suitable size with modular white cover plate , frame, blanking plate etc as reqd at site and making good the disturbed surfaces to match with the existing complete all as specified and directed for one light point controlled by one, one way switch 06 Amps. | 260 | Per point | 265 ₹68,900 | 229 ₹59,540 | 150 ₹39,000 Lowest | 180 ₹46,800 | 190 ₹49,400 | 249 ₹64,740 | 301 ₹78,260 | 230 ₹59,800 | 239 ₹62,140 | 220 ₹57,200 |
| 3.00 | All as per the description of srl item No 02 here-in-before but for one bell point controlled by one bell push switch 06 Amps. | 22 | Per point | 265 ₹5,830 | 229 ₹5,038 | 150 ₹3,300 Lowest | 180 ₹3,960 | 190 ₹4,180 | 249 ₹5,478 | 301 ₹6,622 | 230 ₹5,060 | 239 ₹5,258 | 230 ₹5,060 |
| 4.00 | All as per the description of srl item No 02 here-in-before but for one ceiling / Exhaust fan point controlled by one, one way switch 06 Amps. | 120 | Per point | 265 ₹31,800 | 229 ₹27,480 | 150 ₹18,000 Lowest | 180 ₹21,600 | 190 ₹22,800 | 249 ₹29,880 | 301 ₹36,120 | 230 ₹27,600 | 239 ₹28,680 | 240 ₹28,800 |
| 5.00 | All as per the description of srl item No 02 here-in-before but for one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch. | 140 | Per point | 265 ₹37,100 | 229 ₹32,060 | 150 ₹21,000 Lowest | 180 ₹25,200 | 190 ₹26,600 | 249 ₹34,860 | 301 ₹42,140 | 230 ₹32,200 | 239 ₹33,460 | 250 ₹35,000 |
| 6.00 | All as per the description of srl item No 02 here-in-before but for one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch. | 85 | Per Point | 125 ₹10,625 | 99 ₹8,415 | 60 ₹5,100 | 50 ₹4,250 Lowest | 190 ₹16,150 | 89 ₹7,565 | 301 ₹25,585 | 90 ₹7,650 | 99 ₹8,415 | 89 ₹7,565 |
| 7.00 | All as per the description of srl item No 02 above but for point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed. | 110 | Per point | 315 ₹34,650 | 350 ₹38,500 | 299 ₹32,890 | 220 ₹24,200 Lowest | 230 ₹25,300 | 299 ₹32,890 | 301 ₹33,110 | 330 ₹36,300 | 279 ₹30,690 | 259 ₹28,490 |
| 8.00 | Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of same size ie.1.5 Sqmm and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box of suitable size with modular white cover plate , frame, blanking plate etc as reqd at site and making good the disturbed surfaces complete all as specified and directed for one light point controlled by one, one way switch 06 Amps. | 220 | Per point | 265 ₹58,300 | 229 ₹50,380 | 400 ₹88,000 | 180 ₹39,600 | 150 ₹33,000 Lowest | 249 ₹54,780 | 301 ₹66,220 | 230 ₹50,600 | 239 ₹52,580 | 210 ₹46,200 |
| 9.00 | All as per the description of srl item No 08 here-in-before but for one bell point controlled by one bell push switch 06 Amps. | 20 | Per point | 265 ₹5,300 | 229 ₹4,580 | 400 ₹8,000 | 180 ₹3,600 Lowest | 200 ₹4,000 | 249 ₹4,980 | 301 ₹6,020 | 230 ₹4,600 | 239 ₹4,780 | 199 ₹3,980 |
| 10.00 | All as per the description of srl item No 08 here-in-before but for one ceiling / Exhaust fan point controlled by one, one way switch 06 Amps. | 90 | Per point | 265 ₹23,850 | 229 ₹20,610 | 400 ₹36,000 | 180 ₹16,200 Lowest | 200 ₹18,000 | 249 ₹22,410 | 301 ₹27,090 | 230 ₹20,700 | 239 ₹21,510 | 189 ₹17,010 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 Feb 2026, 6:00 pmClosed
GE NORTH DELHI CANTT
GE NORTH DELHI CANTT
WELCOME MAINTENANCE OF INTERNAL ELECTRIFICATION WORK INCLUDING REPLACEMENT OF POINT WIRING/ELECTRICAL FITTING MCCB DBs SUBMAIN WIRING ETC AT MD ACCN AT AIRPORT ROAD STATION ROAD MOUDE ROAD MAP FAFA KABUL LINES UNDER GE NORTH DELHI CANTT 10
2026_MES_748551_1
GE/North-112/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE NORTH DELHI CANTT 10
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE NORTH DELHI CANTT 10
₹90,000
Yes
13 Mar 2026
14 Jan 2026
6 Feb 2026
14 Jan 2026
4 Feb 2026
28 Jan 2026
Taking down carefully copper / aluminium point wiring (light / fan/ socket or power) complete including fittings and ficutre such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces all as specified and directed.
Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of same size ie.1.5 Sqmm and connected to common earth and earth dolly with suitable copper lugs and drawing into existing conduit and replacement of modular metal flush box of suitable size with modular white cover plate , frame, blanking plate etc as reqd at site and making good the disturbed surfaces to match with the existing complete all as specified and directed for one light point controlled by one, one way switch 06 Amps.
All as per the description of srl item No 02 here-in-before but for one bell point controlled by one bell push switch 06 Amps.
All as per the description of srl item No 02 here-in-before but for one ceiling / Exhaust fan point controlled by one, one way switch 06 Amps.
All as per the description of srl item No 02 here-in-before but for one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
All as per the description of srl item No 02 here-in-before but for one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
All as per the description of srl item No 02 above but for point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of same size ie.1.5 Sqmm and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box of suitable size with modular white cover plate , frame, blanking plate etc as reqd at site and making good the disturbed surfaces complete all as specified and directed for one light point controlled by one, one way switch 06 Amps.
All as per the description of srl item No 08 here-in-before but for one bell point controlled by one bell push switch 06 Amps.
All as per the description of srl item No 08 here-in-before but for one ceiling / Exhaust fan point controlled by one, one way switch 06 Amps.
All as per the description of srl item No 08 here-in-before but for one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
All as per the description of srl item No 08 here-in-before but for one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
All as per the description of srl item No 08 above but for point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
Supply and fixing modular switch, 06 Amps, single pole, one way, 230 volts, one module and IP 20 protection complete all as specified & directed.
Supply and fixing modular bell push with indicator, 06 Amps, single pole, one way, 230 volts, complete all as specified & directed.
Supply and fixing modular switch, with indicator, 16 Amps, single pole, one way, 230 volts, one module complete all as specified & directed.
Supply and fixing modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete all as specified & directed.
Supply and fixing modular socket outlet 02 in 01, 03 pin, 06 Amps and 16 Amps, 02 module with shutter complete all as specified & directed.
M&L in replacement for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for One light point controlled by one, one way switch 06 Amps.
All as per the description of srl item No 19 here-in-before but one bell point controlled by one bell push switch 06 Amps.
All as per the description of srl item No 19 here-in-before but one ceiling /Exhaust fan point controlled by one, one way switch 06 Amps.
All as per the description of srl item No 19 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
All as per the description of srl item No 19 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
All as per the description of srl item No 19 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F in replacement of switch piano flush type, 06 Amps, single pole, one way, 230 volts complete
S&F in replacement of bell push, flush type, 06 Amps, 230 volts with switch frame complete
S&F in replacement of switch piano flush type, 16 Amps, single pole, one way, 230 volts with switch frame complete
S&F replacement of socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 230 volts with socket frame complete
S&F in replacement of socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 230 volts with socket frame complete
S&F in replacement of Ding dong bell, AC, 230 volts, single pole complete all as specified & directed.
Supply and fixing ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 100 watts, duly ISI marked complete all as specified & directed.
Supply and fixing ceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete all as specified & directed.
S&F in replacement lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 9 W LED bulb complete all as specified & directed.
S&F in replacement decorative wall mounting, fixture with opal PC diffuser suitable for 10/12 watt LED Lamp, lamp holder, including 12 Watts LED bulb of 6500 K , and all accessories pre-wired including connecting up complete all as specified and directed.
S&F in replacement surface and wall mounted LED batten 10 watt 2 feet long extruded aluminium housing provided for efficient heat dessipation with polycarbonate diffusser and integrated electronic drive suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in replacement surface and wall mounted LED batten with polycarbonate housing and initigarated electronic drive 20 Watt fixture 4 feet provided for efficient heat dissipation with policorbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete all as specified and directed.
S&F in replacement garden light fitting 9/12 watts, rated LED, alluminium houing, powder coated, PMMA Diffuser. with and including of brick/PCC work all as requad at side but not less than in size as directed by Engr.in Charge.
S&F in replacement LED 45 Watts post top lantern with die cast aluminium lighting fixture, polycarbonate diffuser, sillicon rubber gaskat, stainless steel screws, corrosion and UV rays resistant coating and IP 65/66 with and including all fixing and connecting up with provision of PVC insulated copper conductor cable 1.5 Sqmm, 2/3 core as required for connections complete all as specified and directed.
S&F in replacement LED 25 Watts post top lantern with die cast aluminium spigot spun aluminium powder coated top cover aluminium clear acrylic and IP 65/66 with and including all fixing arrangment and connecting up with provision of PVC insulated copper conductor cable 1.5 Sqmm, 2/3 core as required for connections complete all as specified and directed.
S&F in replacement of size 6/8 inches dia and up to 18 Watt round LED panel recess/surface mounting downlight in CDL with integraed driver to delivered superior light output and uniformity utilising the latest LED technology, ceiling cutout 145mm mm dia hight max 35mm recess luuminaries all as specified and directed.
S&F in replacement LED flood light 120 watt 230 Watt AC outdoor type with thermal management in multiple optics and equipped with IP65/66 protection, with impact and corrosion resistant complete with driver and lamp. and all accessories complete, arrangements for mounting of fitting i.e. bracket, clamps, nuts, bolts and washers etc all as per site requirement including connecting up with provision of PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections complete. all as specified and directed.
All as per the description of srl item No41 here-in-before but 100 watt
All as per the description of srl item No 41 here-in-before but 70 watt
S&F in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 Volt AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size with connector block complete all as specified and directed.
S&F in replacement energy saving LED security light fitting of 35 watts Versatile pressure die-cast aluminium houseing IP 65/ 66 with high power LED as light source comprising with electronic driver and all accessories pre-wired with and incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and suitable GI bracket for mounting of light fitting, bend to shape and fixed to wall by means of suitable flat iron clamps, nuts, bolts and washers etc complete all as specified and directed.
S&F in replacement Ventilating fan wall mounted type of 250 mm sweep, 230 volts, AC, 50 Hz capacity, cutting of hole in wall, making , all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed by Engineer - in - charge.
S&F in replacement Ventilating fan wall mounted type of 200 mm sweep, 230 volts, AC, 50 Hz capacity, cutting of hole in wall, making , all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed by Engineer - in - charge.
S&F in replacement wall mounted fan of 400 mm sweep, 230 volts, AC, 50 Hz capacity, including all arrangements for mounting of fan with and including connecting up with provision of PVC insulated flexible copper conductor cable 1.5 Sqmm, 2 core as required for connections complete all as pecified and as directed.
Material and labour for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 04 Sqmm copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade or higer with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces complete all as specified & directed, including taking down old sub main wiring. Note : Two run for neutral and phase and one run for continuous eart wire for earthing. shall be measured as one unit.
All as per the description of srl item No 49 here in before but 06 Sqmm nominal cross sectional area and including continuous earth wire of size 06 Sqmm nominal cross sectional area.
All as per the description of srl item No 49 here in before but 10 Sqmm nominal cross sectional area, four single core, including rigid non-metallic PVC concealed conduit of 32 mm dia and including continuous earth wire of size 10 Sqmm nominal cross sectional area.
S&F in replacement industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 230 volts of 20 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
S&F in replacement sheet metal enclosure distribution board, duble door type single pole and neutral, AC, 230 volts, 08 way, with 200 Amps rated copper bus bar with IP - 43 & IK 09 protection along with cable end box and flush to wall including all cutting etc in wall and making good to the disturbed surfaces complete all as specified directed.
All as per the description of srl item No 53 here in before but 12 way
S&F (in replacement) sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 415 volts, 04 ways with 200 Amps rated copper bus bar and metal double door suitable for MCCB 125 amps as incomer and MCB SP as outgoing along with cable end box and flush to wall including all cutting etc in wall and making good to the disturbed surfaces complete (Note :- MCCB & MCB SP will be measured seperately)
S&F in replacement MCCB 125 amps, 4 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line/ VTPN DB & connection complete
S&F in replacement 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning by using suitable copper lugs complete all as specified and drected.
SP 5 to 32 Amps
SPN 40 to 63 Amps
S&F in replacement exhaust fan, steel body, AC, single phase, 230 V of size 300mm sweep complete with blades, frame & louver having 1400 RPM speed, 1600 CMH including making of holes of suitable size and taking down old exhaust fan and depositing to MES store yard making good to the disturbed surfaces complete all as specified and as directed.
S&F in replacement , Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 220 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block to ceiling rose complete and taking down old/unsv fan and deposit in E/M store yard complete all as specified and directed
Supply and fix electric water heater, storage type 25 ltrs capacity, BEE 5 star rated, vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adapter for inlet and outlet water connection, copper element corrosion resistance antiscaling magnesium anode having adustable knobe for temperature control and inner tank material of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure having heating element 2 KW and minium two year warranty on product, minimum three years on heating element complete and taking down old/unsv Geyser and deposit in E/M store yard complete all as specified and as directed.
Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 4.0 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed.
S&F or passing through pipe, 10 Sqmm, 2 core, 1100 Volts grade, heavy duty, multi-stranded, PVC insulated, aluminium conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed service cable for service connections from existing LT Panel/Pole to DB/busbar chamber including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_838296.xls
BOQ • 0.28 MB
Gen112.pdf
Tender Documents • 0.99 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .