| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹32.8 L+₹5.2 L (18.8%)Rejected-AOC 34 KAISER GANJ MANDI DIST MEERUT UP 250002 | MEERUT | UTTAR PRADESH | 250002 | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹34.0 L+₹6.4 L (23.1%)Rejected-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹37.3 L+₹9.7 L (35.0%)Rejected-AOC C O GIVEN GOD NONGTDAU ARBUTHNOT ROAD NONGRIMMAW LAITUMKHRAH SHILLONG PIN 793011 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793011 | L4 | Rejected-AOC Not Lowest | |
| 5 | L5₹37.7 L+₹10.1 L (36.6%)Rejected-AOC | L5 | Rejected-AOC Not Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
2 Jan 2021, 6:00 pmClosed
GE (I) (AF) SHILLONG
GE (I) (AF) Shillong Elephant Falls Camp PO Nonglyer Shillong-793009
CA No. GE (I) (AF) /SHL/ OF 2020-2021 REPAIR/ MAINTENANCE OF BOUNDRY WALL, GRATING, WOODEN FLOORING AND MISCELLANEOUS WORKS DUE TO STORM DAMAGE AT HQ EAC (U) UNDER GE (I) (AF) SHILLONG
2020_MES_401574_1
8025/20/SHL/2020/21
Open Tender
Civil Works
Works
180 days
SHILLONG
For Enlisted Contractors Class D Category a i and for unenlisted contractors meeting enlistment criteria for required Class and Category
7 documents required · 7 mandatory
₹500
GE (I) (AF) SHILLONG
₹80,000
Yes
6 Feb 2021
7 Dec 2020
4 Jan 2021
7 Dec 2020
2 Jan 2021
21 Dec 2020
7 Dec 2020 - 14 Dec 2020
Amount
Note : All unserviceable materials obtained out of demolition/dismantling/taking down (other than those for which credit catered under Schedule of credit) shall be disposed of outside MoD Land. Quoted rates against respective item shall deemed to include for same.
B/R ITEMS Demolition of brick work/ block masonry or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removal all rubbish material complete all as specified directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness below or above ground level and removal all rubbish material complete all as directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in any position not otherwise specifically provided for and removal all rubbish material complete all as directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed.
Dismantling timber scantlings 40 Sqcm and over in section, in any position complete all as directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed trusses etc complete all as specified and directed.
Dismantling fencing wire mesh any type complete all as directed.
Dismantling existing Galvanised steel barbed wire in fencing in any situation and in any position complete all as specified and directed.
Dismantling existing concertina coil in fencing in any situation and in any position complete all as specified and directed.
Taking down cement or cement lime plaster any description, on brick or stone walls, etc. including raking out joints, hacking for key & scrubbing down with water, etc. & removing rubbish off the premises, complete all as directed.
Dismantling of 110mm bore PVC(SWR) drain pipe alongwith fittings and accessories jointed in cement mortar and taking out from walls, floors or from trenches, if required complete all as specified and directed. (Note :- The length shall be measured along the centre line including fittings and accessoires).
Excavation in post holes (or similar holes) in soft/loose soil, each n.exc 0.5 cum, getting out, returning, filling in and ramming moorum or broken rubble mixed with moorum in layers n.exc 25cm around foundation concrete as ordered, watering and removing surplus soil to a distance not exceeding 50 m and making good surface, complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes or for laying underground cable, pipe lines etc. in soft/ loose soil, complete all as specified & directed.
Excavation in trenches, n exc 1.5 m wide and exc 1.5 m but n. exc 3.0 m in depth or n exc 10 Sqm on plan and exc 1.5 m but n. exc 3.0 m in depth & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes or for laying underground cable, pipe lines etc. in soft/ loose soil, complete all as specified & directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in soft / loose soil complete all as specified and directed.
Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M & L for hard core of broken stone or boulders of gauge n.exc 63 mm, deposited, spread & levelled in layers n.exc 15 cm thick watered & rammed to true surface complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
M & L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
M & L for precast cement concrete type C-1, 1:3:6 using 20mm graded aggregate as in bond stones set and jointed in cement mortar 1:6 complete all as specified and as directed.
M & L Reinforced cement concrete M-25 (design mix) using graded stone aggregate as in foundation including rafters footings foundation beam plinth beam bases for column etc basement slab under reamed piles and mass concrete complete all as specified and directed.
M & L for Reinforced cement concrete Design Mix M-25 using graded stone aggregate as in columns, pillars piers, posts & struts etc complete all as specified and directed.
M & L Reinforced cement concrete M-25 gradeusing graded sone aggregate as in beams, cantilever, bressummers, lintels over 1.5 m span complete all as specified and directed .
M&L for pre-cast cement concrete block masonry 1:3:6 Type C-1 using 20mm graded stone aggregate with solid blocks, exc. 10 cm in width and setting in cement mortar 1:4, complete all as specified and directed.
M & L for Walling of random rubble uncoursed well bonded, bedded & solidly hearted built in cement mortar 1:6 complete all as specified and directed. (Note : Volume occupied by PCC bond stone shall not be measured against this item. Volume occupied by PCC bond stone shall be measured and under respective item here-in-after.)
M & L for Use and waste of flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete complete all as specified and directed.
M & L for Use and waste of flat formwork to sides of pillars (square, rectangular or polygonal), posts, struts, piers,columns and stanchions for fair finished surfaces of concrete complete all as specified and directed.
M & L for Use and waste of flat formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished surfaces of concrete complete all as specified and directed.
M & L for second class hard wrought as in scantling framed and fixed complete all as specified and directed.
S & F of 40mm thick second class hardwood (CHIR) boarding as in floors and skirting planed one side and edges tongued and grooved or rebated and fixed with nails complete all as specified and directed.
M & L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M & L for TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups, spacers & binders, cut to length, bent to shapes required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S & F mild steel angle iron fencing posts, struts and flat iron for fixing chain link fencing and similar work conforming to Fe-290 Gde E- 165 including cutting tops to shape as directed, bent to shape, drilling holes, notching, hooking for wire etc. complete all directed.
S & F mild steel work conforming to Fe-290 Gde E-165 as in Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work complete all as specifed and directed.
M & L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. Note :- Supply only Chain link and line wire shall be measured and paid separately under respective items.
Supply only mild steel galvanized chain link fencing, any size or type as directed complete all as specified and directed.
Supply only 10 mm dia mild steel round bars conforming to Fe-410-W (Gde-E-250) quality 'A' or Fe-290 Gde E-165 bars as in line wire of fencing for fixing chain link fencing complete all as specified and directed.
S & F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. (each line of wire to be measured)
S & F concertina coil razor tape barbed wire (reinforced barded tape) of the following specification:- (i) Dia of coil when un stretched 600mm (ii) No of circles 5 Per Rm (iii) Weight of each coil 9.5 to 10 KG (iv) Coverage per coil 8 RM (v) Central core wire:- Made from high tensile spring steel core wire confirming to IS-4454 duly hot dipped galvanised (Confirming to IS-2629) with dia meter 2.59mm + 0.05mm, UTS 145-160 Kg/Sqmm, Zinc coating 250-300 Per Sqm (vi) Strip:- Electro galvanised steel strip 0.5mm + 0.02mm thick, width 19mm (before wrapping on central core wire) confirming to IS-1573, Zinc coating-120 gm/ Sqm and bituminised dipped, width of barbs 11.5mm, pitch of barbs 25.4mm + 0.2mm (vii) Clips:- AISI 304-1.5mm thick C and U clips (C special type for fixing coil and RBT wire U clips special type for joining one coil to another coil and RBT wire to RBT wire joining) (viii) No of clips 125 for each coil (ix) Handle and spikes to be provided as required Make:- 1. MORRIS BALFOROUR & CO TELE No. 033-2233-1204, 2230-9846 2. GLOBAL FENCING WORKS MUMBAI TEL No. 23859-454-23857-374 or any other equvalent makes as approved by the Accepting Officer. NOTE:- Running length of the wall shall be measured for purpose of payment.
S & F for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 5cm but not exceeding 10cm long and dia of neck exceeding 11mm but n.exc 15mm complete all as specified and directed
M & L for 25 mm thick PCC 1:2:4 type B-0, using 12.5 mm graded stone aggregate as in levelling coarse of floors, surfaces finished even and fair complete all as specified and directed.
M & L for 20 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes complete all as specified and directed.
M & L for 20 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
M & L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed.
M & L for Pavement floor vitrified tiles of size exc 0.09 Sqm but not exc 0.36 Sqm 10mm thick (Endura tiles of Johnson or equivalent makes listed in List of Makes) set & jointed in neat cement slurry and pointed with grey cement and pigment to match the colour of tiles in floor complete all as specified and directed.
M & L for prepolished cement concrete chequered tiles of size 305 x 305 x 20 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M & L for 60mm thick PVC moulded precast interlocking paving blocks factory casted using grey cement and pigment, casted in an automatic plant working on vibration and simultaneous hydraulic compression from top, confirming to IS-15658-2006 and of shape haxagon/ triangular/ zigzag/ I-shaped etc. as directed having compressive strength not less than 350 Kg/ Sqcm laid over and including 25 to 30mm thick layer of sand cushioning including filling the interstices with & including sand and interstices on edges filled with PCC 1:2:4 type B-1 finished even and smooth without using extra cement complete all as directed.
M & L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick or concrete surfaces finished even and rough for receiving wall tiles/dado complete all as specified and directed.
M & L for rendering 15 mm thick on fair faces of brick masonry/ concrete surface in CM (1:4), finished even and smooth without using extra cement complete all as specified and directed.
M & L for raised pointing to random or polygonal rubble masonry uncoursed or brought upto courses in CM 1:4 complete all as specified and directed.
M & L for glazed ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as on vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces of wall, applying a coat of 1mm thick wall care putty and applying two coats of weather proof acrylic paint over one coat of exterior grade acrylic primer complete all as specified and directed. Make-Apex Ultima of Asian, weather shield MAX of ICI/Dulux, weather coat long life of Beger, Acroguard 3X of Acro paint.
M&L for preparing surface of timber piles and dipping in a hot mixture of tar and creosote in the proportion of 20 kg coal tar pitch to 25 litres of creosote oil for 4 mins complete all as specified and directed.
M & L for French Polishing on new wooden or wood based surfaces of any description width or girth including cleaning and preparing the new surface including a coat of wood filler with two or more coats complete all as specified and directed.
M & L for preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of 1st grade quality over and including one coat of red oxide zinc chrome primer complete all as specified and directed.
S & F PVC (SWR) 110mm bore pipes double socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S & F PVC (SWR) 110mm bore pipes double socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F PVC (SWR) bend for 110mm bore pipe of any radius with oval access door complete all as specified.
S & F PVC (SWR) 110mm junction, single (single T) equal or unequal complete all as specified and directed .
S & F PVC (SWR) vent cowl for 75 mm bore of pipe complete all as specified and directed.
M/s Gupta Construction
M/S BISWA CONSTRUCTION
M/s J. C. CONSTRUCTION
M/S C.M.V CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .