| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAccepted-AOC NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹4.2 L Quoted ₹4.3 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹4.9 L+₹62,396 (14.5%)Rejected-Finance | ₹4.9 L+₹62,396 (14.5%) | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | Rejected-Technical | - | - | Rejected-Technical NOT BEING ELIGIBLE |
| Sl No | Description | Qty | Unit | UNIVERSAL ENGINEERING L1 | PLATINUM CONSTRUCTIONS L2 |
|---|---|---|---|---|---|
| 1.00 | M&L for complete servicing after pumping down Indoor/outdoor units of window/split AC 1.5/2 TR capacity of any make from its existing position/location, shifting the same, by by cleaning condenser/ Evaporator coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary applying oil in fan motor bushes checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, cleaning the air filter, connecting up all connections and testing after gas charging if required all as directed for Split type Air Conditioner up to 2.0 Ton. Note : (i)Replacement of spare parts will be measured and paid separately under relevant items of BOQ.(ii) In case of shutdown of AC,Complaints shall be attended by Mechanic with in four hrs .(iii) If Contractors fails to attend the complaints within 4 hrs ,shall be imposed panelty 100 Rs per hrs . | 120 | Each job | 500 ₹60,000 Lowest | 700 ₹84,000 |
| 2.00 | Supply and fix Running Capacitor 36/45/55 mfd all as specified and directed . | 30 | Each | 350 ₹10,500 Lowest | 450 ₹13,500 |
| 3.00 | Supply and fix Wiring kit complete set all as specified and dIrected . | 2 | Each | 150 ₹300 Lowest | 250 ₹500 |
| 4.00 | Supplying and Fixing in repairs Copper tube 1/2 " with adapter/flair nuts ,insulation foam all as specified and directed . | 20 | RM | 500 ₹10,000 | 450 ₹9,000 Lowest |
| 5.00 | Supplying and Fixing in repairs Copper tube 1/4 " with adapter/flair nuts,insulation foam all as specified and directed . | 20 | RM | 300 ₹6,000 Lowest | 500 ₹10,000 |
| 6.00 | Supplying and Fixing in repairs Copper tube 3/4 " with adapter/flair nuts,insulation foam all as specified and directed . | 20 | RM | 550 ₹11,000 Lowest | 650 ₹13,000 |
| 7.00 | Supplying and Fixing in repairs PC unit/electronic circuit plate of appropriate make/model of 1.5/2 TR Acs all as specified and directed . | 10 | Each | 2,200 ₹22,000 | 1,500 ₹15,000 Lowest |
| 8.00 | Supply and fix Remote control with batteries of appropriate make/model for Split type AC all as specified and directed . | 5 | Each | 950 ₹4,750 | 650 ₹3,250 Lowest |
| 9.00 | M&L for Gas charging including testing complete in split/window type AC 1.5/2.0 TR any type all asspecified and directed by Engineer in charge (Gas charging same as existing) | 30 | Each job | 1,050 ₹31,500 Lowest | 2,100 ₹63,000 |
| 10.00 | M& L for Removing the existing defective / unserviceable hermetically sealed compressor unit from Acs and replacement with the same Make factory sealed compressor unit, connecting refrigeration system after thorough flushing out the system with dry nitrogen, leak testing with nitrogen, vaccumising including neccessery brazing and welding arresting leakages and gas charging with refrigerant gas, testing, re-installing in its original position/location connecting up all electrical connections, testing the complete unit all as directed for Split ACs of appropiate make / model for 1.0 TR AC. Notes :–
(i) Factory sealed compressor unit shall be of existing capacity and make.
(ii) Gas Charging shall be measured and paid separately under relevant item of this schedule. | 1 | Each | 12,000 ₹12,000 | 11,500 ₹11,500 Lowest |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
11 Apr 2025, 5:00 pmClosed
Shri Shubham Yadav,AEE
Asst Garrison Engineer I AF Chimney Hills Chikkbanavara Post Bangalore, PIN- 560 090
MAINTENANCE AND REPAIR TO SUMMER AND COOLING APPLIANCES AT 58 SU UNDER AGE(I) AF CHIMNEY HILLS
2025_MES_700542_1
8781/E8
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
AGE I AF CHIMNEY HILLS BANGALORE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
AGE I (AF) Chimney Hills, Bangalore
₹10,000
Yes
19 Dec 2025
7 Mar 2025
14 Apr 2025
7 Mar 2025
11 Apr 2025
28 Mar 2025
7 Mar 2025 - 21 Mar 2025
Amount
M&L for complete servicing after pumping down Indoor/outdoor units of window/split AC 1.5/2 TR capacity of any make from its existing position/location, shifting the same, by by cleaning condenser/ Evaporator coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary applying oil in fan motor bushes checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, cleaning the air filter, connecting up all connections and testing after gas charging if required all as directed for Split type Air Conditioner up to 2.0 Ton. Note : (i)Replacement of spare parts will be measured and paid separately under relevant items of BOQ.(ii) In case of shutdown of AC,Complaints shall be attended by Mechanic with in four hrs .(iii) If Contractors fails to attend the complaints within 4 hrs ,shall be imposed panelty 100 Rs per hrs .
Supply and fix Running Capacitor 36/45/55 mfd all as specified and directed .
Supply and fix Wiring kit complete set all as specified and dIrected .
Supplying and Fixing in repairs Copper tube 1/2 " with adapter/flair nuts ,insulation foam all as specified and directed .
Supplying and Fixing in repairs Copper tube 1/4 " with adapter/flair nuts,insulation foam all as specified and directed .
Supplying and Fixing in repairs Copper tube 3/4 " with adapter/flair nuts,insulation foam all as specified and directed .
Supplying and Fixing in repairs PC unit/electronic circuit plate of appropriate make/model of 1.5/2 TR Acs all as specified and directed .
Supply and fix Remote control with batteries of appropriate make/model for Split type AC all as specified and directed .
M&L for Gas charging including testing complete in split/window type AC 1.5/2.0 TR any type all asspecified and directed by Engineer in charge (Gas charging same as existing)
M& L for Removing the existing defective / unserviceable hermetically sealed compressor unit from Acs and replacement with the same Make factory sealed compressor unit, connecting refrigeration system after thorough flushing out the system with dry nitrogen, leak testing with nitrogen, vaccumising including neccessery brazing and welding arresting leakages and gas charging with refrigerant gas, testing, re-installing in its original position/location connecting up all electrical connections, testing the complete unit all as directed for Split ACs of appropiate make / model for 1.0 TR AC. Notes :– (i) Factory sealed compressor unit shall be of existing capacity and make. (ii) Gas Charging shall be measured and paid separately under relevant item of this schedule.
All as per item No.16 above but 1.5 TR capacity.
All as per item No.16 above but 2.0 TR capacity
S&F in replacement condensor fan Motor for 1.5/2.0 TR AC of existing make
Replacement of Cable PVC insulated and sheathed 3 core 4 sqmm by removing burnt cable from Acs
Replacement of rusted outdoor mounting stand set with new one for outdoor unit of Split type AC including nuts, bolts & wahers etc.
Removing the outlived Insulating teflon sheets from the existing copper tubes of Split type Air conditioners, S&F the same on copper tubes from inner unit to outer unit complete all as specified and directed.
S&F in replacement copper condensor coil for outdoor unit of 1.5/2.0 TR AC of existing make
Servicing of water cooler storage capacity 80/120 ltr and cooling capacity 40/60 Ltr per hour any make by opening, cleaning of water tank, cooling coil and condensers including complete body with brush, air blower, oiling/greasing fan motor rectification of loose electric connections and replacement of unserviceable drain pipe etc complete all as directed Note : Replacement of spare parts will be measured and paid separately under relevant items of BOQ.
M&L for Gas charging including testing complete in Water cooler any type all asspecified and directed by Engineer in charge (Gas charging same as existing)
Replacement Starting Capacitor 60-80 mfd for WaterCoolers all as specified and directed
Replacement Running Capacitor 25 mfd for water coolers all as specified and directed .
Replacement Starting Relay for water coolers all as speciifed and directed .
Removing the existing defective / short circuited hermetically sealed compressor unit from water cooler and replacement of the same with company rewound sealed compressor unit of appropiate make / model for water cooler 40/80 ltrs.
Removing the existing defective / short circuited hermetically sealed compressor unit from water cooler and replacement of the same with company rewound sealed compressor unit of appropiate make / model for water cooler 180 ltrs.
Servicing, maintenance and repairs to Refrigerator / Deep Freezer of capacity up to 310 Ltrs of any make and model including periodical cleaning to condenser coil and compresser, Replacement of defective spares will be measured and paid separately under relevant items as under complete all as specified and directed .
M&L for Gas charging including testing complete in Refrigrator/Deep Freezer any type all asspecified and directed by Engineer in charge (Gas charging same as existing)
Replacements Starting Relay for Refrigerator all as specified and directed .
Supply and fix Ice cube Tray plastic set of two all as specified and directed .
Hard plastic Stand suitable for Refrigerator of any make / model up to 310 ltr.
Removing the existing defective / short circuited hermetically sealed compressor unit from the Refrigerator, Replacement of the same with company rewound sealed compressor unit of appropriate make / model for Refrigerator capacity upto 310 ltrs.
S&F voltage stabilizer 5/4 KVA capacity suitable for 1.5/2.0 TR AC complete all as specified and directed.
S&F voltage stabilizer 3/2 KVA capacity suitable for Refrigrator/Deepfreezer AC complete all as specified and directed.
Supply and fix sheet metal enclosures with socket plug top of capacity alongwith 20 Amps MCB SP all as specified and directed by engineer in charge .
S&F in replacement of plugtop 15 amps 3 pin connection complete all as specified and directed by Engineer in charge
PLATINUM CONSTRUCTIONS (BID ID -3274034)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .