Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹36.2 L+₹1.2 L (3.45%)Rejected-Finance 144 VIKAS BAZAR MATHURA UP 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹36.4 L+₹1.4 L (3.94%)Rejected-Finance MITTAL NIWAS DHANAULA PUNJAB 148105 | DHANAULA | BARNALA | PUNJAB | 148105 | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹37.8 L+₹2.8 L (8.00%)Rejected-Finance 37 TILAK NAGAR MATHURA 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹38.0 L+₹3.0 L (8.52%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
30 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST MATHURA
Garrison Engineer East Military Engineer Services Mathura Cantt Mathura 281001
REPAIR/IMPROVEMENT OF LT NETWORK CABLES AND PANELS UNDER GE (EAST) MATHURA
2023_MES_627517_1
8200-1403/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE EAST MATHRURA
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE EAST MATHURA
₹1 L
29 Dec 2023
8 Nov 2023
2 Dec 2023
8 Nov 2023
30 Nov 2023
23 Nov 2023
8 Nov 2023 - 30 Nov 2023
Amount
M&L for prepration old steel surface of LT Panel board/Feeder Pillar box of any size by scrubing the existing damage paint and applying of two coats of synthetic enamel paint over a coat of red oxide primer at various location in Mathura Cantt complete all as specified and as directed.
M&L for welding works to LT Panel/Bus Bar/Feeder pillar box for fixing/welding hinges, locking arrangement or reapir pitted area etc at site complete all as specified and as directed.
Supply and fixing cable tray 300 mm wide including all accessories for carrying out LT cable upto transformer complete all as specified and as directed.
Supply and Fixing in replacement of Aluminium Bus Bar of capacity 200 Amp suitable for LT panels/ Bus bars/Feeder pillar box, rectangular shape and existing design etc including nut, bolt and washers complete all as specified and as directed.
Supply and Fixing in replacement of Aluminium Bus Bar of capacity 400 Amp suitable for LT panels/ Bus bars/Feeder pillar box, rectangular shape and existing design etc including nut, bolt and washers complete all as specified and as directed.
Supply and Fixing in replacement of Aluminium Bus Bar of capacity 600 Amp suitable for LT panels/Bus bars/Feeder pillar box, rectangular shape and existing design etc including nut, bolt and washers complete all as specified and as directed.
Supply and Fixing in replacement of Ammeter of rating 63 Amp on LT panel board/Bus bar/LT feeder box in four step (R,Y,B and OFF) without CT, including nuts,bolts etc complete all as specified and directed.
Dismantling old unserviceable cross arms and anti climbing devices of any size from pole/structures complete all as specified and as directed.
M&L for mild steel cross arms, bracings, support, clamps and back plates fabricated from structural steel section confirming to Fe-410-O or Fe-310-O including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including applying two coats of aluminium paint over a coating of red oxide primer complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundations, laying of cables etc. and getting out as in soft/loose soil complete all as specified and as directed.
All as per serial item No 11.00 here-in-before but depth exc exceeding 1.5 but n. exc 3.00 mtr complete all as specified and as directed.
Returning filling in earth obtained from excavation including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for sand cushioning to under ground cable in trenches in layers of 8 cm thick before laying the cable and 15 cm thick after laying of cable and stretching the cable and punned the sand as specified complete all as specified and as directed. Note : Punned depth shall be measured for payment.
Supply and Laying Unreinforced precast concrete cable cover class LV type 1, flat, size 250mmx150mmx40mm complete all as specified and as directed.
Supplying, laying or fixing or passing through pipe, testing and commissioning XLPE insulated, armoured heavy duty electric underground cable, aluminium conductor 1100 volt grade including taking down/out of trenches U/S cable of following cross sectional area :- Note : Excavation and earth work shall be measured & paid under appropriate item(s) of this BOQ.
35 Sqmm 3.5 core.
50 Sqmm 3.5 core.
70 Sqmm 3.5 core.
95 Sqmm 3.5 core.
120 Sqmm 3.5 core.
150 Sqmm 3.5 core.
185 Sqmm 3.5 core.
240 Sqmm 3.5 core.
300 Sqmm 3.5 core.
S&F cable sleeves suitable for XLPE LT UG cable of following sizes:-
16 Sqmm to 50 Sqmm.
70 Sqmm to 120 Sqmm.
150 Sqmm to 185 Sqmm.
240 Sqmm to 300 Sqmm.
Supply and fixing in replacement of 3 phase volt meter, 0-500 volt digital type square or rectangle type 96 sq mm lamp accurracy glass complete all as specified and as directed.
Supply and fixing in replacement of 3 phase Ammeter, 0-500 Amp digital type square or rectangle 96 sq mm lamp accurracy glass complete all as specified and as directed.
Supply and fixing in replacement of CT coil suitable for Amp meter 100/5 Amp complete all as specified and as directed.
Supply and fixing in replacement of indicating lamp set RYB for phase indication operating 240 volt 50 HZ AC with new one LED panel mounting type to match the existing one complete all as specified and as directed.
Supply, installing, commissioning and testing of LT panel board outdoor type of suitable size cubical type made out CRCA sheet 3.15 mm thick, inner sheet 2.0 mm thick, dust and vermin proof and angle iron of suitable size, pedestal flame grouted in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregated) thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with aluminum bus bar of rating 300Amp (for R,Y,B phase) & 200Amp (for neutral), (in separate chamber) including painting with two coats synthetic enameled paint over a coat of red oxide primer and consisting of the following:- (a) MCCB 250 Amp, 4 Pole, 25KA adjustable thermal based released (Incoming)- 01 No (b) MCCB, 125 Amp, 16 KA, 4 Pole fixed thermal and fixed magnetic (O/G)- 02 Nos (c) MCCB 100 Amp, 16 KA, 4 Pole - 03 Nos (d) Digital Amp meter (0-250) - 01 No (e) Digital Volt meter (0-500) 01 Nos (d) RYB indicator - 01 Set Note : Drawing of LT panel shall be got approved from GE before placing order for procurement.
M&L for laying GI tubing, light grade, 50 mm bore dia as cable protection fixed on walls/poles/road crossing and laid in floor complete all as specified and as directed.
M&L for laying GI tubing, light grade, 80 mm bore dia as cable protection fixed on walls/poles/road crossing and laid in floor complete all as specified and as directed.
Supplying, installing, testing and commissioning OUT door type, cubicle type, floor mounted LT Panel made out of MS sheet of 3.15mm thickness for outer sheet and 2 mm for inner sheet suitable for Aluminium busbar of 200 Amp for 3 phase, 4 wire, 415 volts, 50 Hz and CPRI approved, factory made in an approved factory comprising of the following as approved wirh following accessories:- (a) MCB 16 Amp, 4 Pole of rating 10 KA - 01 Nos (for incoming) (b) MCB 10 Amp TPN of rating 10 KA - 01 Nos (for outgoing ) (c) Timer switch TP 20 Amps - 01 No (d) Onload change over switch 4 Pole, 16 Amps- 01 No (e) Digital type Ammeter (0-200 Amp) - 01 Nos (e) Digital type volt meter (0- 500 V) - 01 No Note : Drawing of Bus bar box shall be got approved from GE in writting before placing order for procurement.
Supply and fixing in replacement of MCCB 630Amp rating,4-pole 415V, Electronic release with overload and short circuit adjustable type breaking capacity 36KA complete all as specified and as directed.
Supply and fixing in replacement MCCB 4 pole 415 Volts thermal magnetic based adjustable type 400 Amp, with breaking capacity 36kA Complete all as spccified and as directed.
Supply and fixing in replacement MCCB 4 pole 415 Volts thermal magnetic based adjustable type 315 Amp, with breaking capacity 36kA Complete all as spccified and as directed.
Supply and fixing in replacement MCCB 4 pole 415 Volts thermal magnetic based adjustable type 250 Amp, with breaking capacity 36kA Complete all as spccified and as directed.
Supply and fixing in replacement MCCB 4 pole 415 Volts thermal magnetic based adjustable type 200 Amp, with breaking capacity 36kA Complete all as spccified and as directed.
Supply and fixing in replacement MCCB 4 pole 415 Volts thermal magnetic based adjustable type 160 Amp, with breaking capacity 16kA Complete all as spccified and as directed.
Supply and fixing in replacement MCCB 4 pole 415 Volts thermal magnetic based adjustable type 100 Amp, with breaking capacity 16kA Complete all as spccified and as directed.
Supply and fixing in replacement MCCB 4 pole 415 Volts thermal magnetic based adjustable type 63 Amp, with breaking capacity 16kA Complete all as spccified and as directed.
Supply and fixing in replacement MCCB 3 pole 415 Volts thermal magnetic based adjustable type 250 Amp, with breaking capacity 35kA Complete all as spccified and as directed.
Supply and fixing in replacement MCCB 3 pole 415 Volts thermal magnetic based adjustable type 200 Amp, with breaking capacity 35kA Complete all as spccified and as directed.
Supply and fixing in replacement MCCB 3 pole 415 Volts thermal magnetic based adjustable type 160 Amp, with breaking capacity 16kA Complete all as spccified and as directed.
Supply and fixing in replacement MCCB 3 pole 415 Volts thermal magnetic based adjustable type 125 Amp, with breaking capacity 16kA Complete all as spccified and as directed.
Supply and fixing in replacement MCCB 3 pole 415 Volts thermal magnetic based adjustable type 100 Amp, with breaking capacity 16kA Complete all as spccified and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material and accessories suitable for 3½/4 core XLPE armoured aluminium conductor cable of size 10 Sqmm to 16 Sqmm complete all as specified and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material and accessories suitable for 3½/4 core XLPE armoured aluminium conductor cable of size 25 Sqmm to 50 Sqmm complete all as specified and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material and accessories suitable for 3½/4 core XLPE armoured aluminium conductor cable of size 70 Sqmm to 150 Sqmm complete all as specified and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material and accessories suitable for 3½/4 core XLPE armoured aluminium conductor cable of size 185 Sqmm to 400 Sqmm complete all as specified and as directed.
Supply, installing, commissioning and testing in replacement of LT panel board indoor type, double door type, cubical type suitable for 3 phase 4 wire 415 volt made out of 2mm thick & size 1700 x1200 x 450mm MS sheet, dust and vermin proof duly supported 40 x 40 x 6mm angle iron frame having a place to fit (on PVC/Wooden board) 12 Nos single phase electric meter complete with locking arrangement and opening arrangement from front and near both duly fitted with compression cable glands for entry & exit of cables, powder coated with two coats and having minimum clearance of 450mm above ground level complete and comprising of the following:- (a) Panel mounted 3 phase volt meter, ammeter - 01 set each (b) Aluminium bus bar - 03 Nos for phase of capacity 200 Amp and 1 Nos 200 Amps for neutral, duly taped in colour coded FRP sleeves. (c) Indicating LED type lamps Red, Yellow and Blue in Colour, complete with lamp holders, 220 volts AC - 01 set of 3 (d) Panel wiring with 2.5 Sqmm PVC sheathed, PVC insulated FR-HR stranded copper conductor cable through MCB DP 10 A mounted on DIN rail. Note : Drawing of LT panel shall be got approved from GE before placing order for procurement.
M&L for dismantaling of old/unserviceable PCC poles/struts any type and size complete all as specified and as directed.
Supply and erecting steel tubular swaged pole with cast iron base plate, finial taper plug, bolts, nuts & screws made out of mild steel tubing, type 410 SP -31 (9 Mtr long) including marking pole No on pole including applying two coat of aluminum paint (one coat before fixing and one coat of aluminum paint after fixing) on exposed surface over a coat of red oxide primer and two coats of bituminous paint over embedded portion & the portion above coping shall be painted in alternative bands of black and yellow colour starting with white colour (each band of 30cm wide) by two coats of super enameled paint upto 1.5m height complete all as specified and as directed. Note : Earth work and PCC in foundation shall be measured and paid separately.
Supply and erecting steel tubular swaged pole with cast iron base plate, finial taper plug, bolts, nuts & screws made out of mild steel tubing, type 410 SP -31 (11 Mtr long) including marking pole No on pole including applying two coat of aluminum paint (one coat before fixing and one coat of aluminum paint after fixing) on exposed surface over a coat of red oxide primer and two coats of bituminous paint over embedded portion & the portion above coping shall be painted in alternative bands of black and yellow colour starting with white colour (each band of 30cm wide) by two coats of super enameled paint upto 1.5m height complete all as specified and as directed. Note : Earth work and PCC in foundation shall be measured and paid separately.
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping complete all as specified and as directed.
Supply, installing, commissioning and testing of LT panel board outdoor type, cubical type made out CRCA sheet 3.15 mm thick, inner sheet 2.0 mm thick, dust and vermin proof as per IS/IEC-:61439-1:2011, 61439-2:2011 having thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with aluminum bus bar 300Amp - 03 Nos for Phase and 01 No's for neutral, (in separate chamber) mounted/fixed on suitable size angle iron frame/stand embedded in cement concrete 1:2:4 type B-1 (using 20mm graded stone aggrigates) including painting steel surface with two coats of synthetic enameled paint over a coat of red oxide primer and consisting of the following:- (a) MCCB 125 Amp, 4 Pole, 25KA - 01 No (b) MCCB, 100 Amp, 16 KA, 4 Pole - 01 No (c) MCCB 63 Amp, 4 Pole - 01 Nos (d) Digital Amp meter (0-250) - 01 Each (e) Digital Volt meter (0-500) - 01 Each (c) RYB indicator - 01 set Note : Drawing of LT panel shall be got approved from GE before placing order for procurement.
M&L for Cutting wild grass, bushes, creaper, unwanted vegetation from inside / surrounding of E/M installations, near transformers, pole structures etc including cutting creapers from barbed/cattle fencing of the installations as when directed and removing of unwanted material from installation compound and depositing complete all as specified and as directed. Note : The item shall be operated maximum three times in entire period of contract in the same installations. (Area shall measured separately each time).
Supplying, installing, testing and commissioning OUT door type HT Bus bar chamber made out of MS sheet of 3.15mm thickness outer sheet and inner sheet thickness 2 mm suitable for 11 KV, 50 Hz AC supply and CPRI approved, factory made in an approved factory having seven tank treatment process for powder coating with thickness not less than 60 microns provided with suitable gasket to make it dust/vermin proof double door type including locking arrangement bus bar chamber enclosed complete having legs 45 cms made out of 65x65x6mm angle iron grouted plateform upto 30 cms & general construction confirming to IS:8623/93 mounted on suitable cement concrete 1:4:8 type D-2 (40 mm graded stone aggregate) foundation comprising of the following:- (a) 80 x 20 sqmm cross section area conductive electrolyte grade aluminium bus bar of required length with heat shrinkable sleeves, duty colour coded. (b) Bakelite insulators having short circuit with stand capacity of 26.3 kilo Amp - 01 (Set of three) Note : (i) The panel shall be front operated with cable entry from bottom with cable glands. The fault with standing capacity shall be 25 KA, Earth bus shall be part part of the main feeder pillar. (ii) Cost for construction of foundation PCC 1:4:8 type D-2 including plaster work, PCC coping 1:2:4 (40mm graded stone aggregate) deemed to be included in the item rate and no extra payment will be made. (iii) Danger sign board of 11000 Volt should be enclosed on panel with red colour.
M&L for Earthing complete with galvanised steel earth plate electrode 60cmX60cmX6.0mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not than 1.5mtr below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10(Nominal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, PGI funnel, wire mesh and 15mm bore GI water pipe medium grade and 40mm bore medium grade GI pipe for protection of earth strip from plate to LT Panel/busbar/Electrical equiptment, common salt, charcoal dust including testing on completion complete all as specified and as directed all as shown in electrical plate No. 3 including testing on completion and making good the disturbed surfaces of wall floors etc without claiming extra cost complete. Note : GI strip beyond 7.5Mtr length from earth electrode shall be measured and paid separately.
All as per item serial No 55.00 here-in-before but using GI wire 4mm dia as earth lead & 15mm bore medium grade GI pipe for protection of earth wire from plate to main switch board complete all as specified and as directed.
Supply and fixing in replacement of Pin type insulator rating 11 KV procelain viterous white, brown or green, ISI marked including on galvanised steel spindle, two galvanised iron washers and one galvanised iron nut complete all as specified and as directed.
Supply and fixing in replacement of Pin type insulator rating 11 KV procelain viterous white, brown or green of size 150mm height and 150mm dia, ISI marked including on galvanised steel spindle, two galvanised iron washers and one galvanised iron nut complete all as specified and as directed.
M&L for chemical earthing in replacement with copper earth plate electrode 90 cm X 60 cm X 5 mm buried directly in ground (earth pit not less than 3.0 mtr deep beliow ground level) with top edge of the plate not less than 2.25 mtrs below normal ground level,connecting to copper strip 32 X6 mm as earthing strip by means of bolts, nut check nut and washers protected with and including 40 mm dia medium grade GI pipe, necessary excavation and earth work, magnesium sulphate (80 Kg) ), charcoal (4 Qtl) and common salt (4 Qtl) filling, watering arrangement with 20 mm GI pipe medium grade including PCC pit with pre cast RCC (1:2:4) cover, GI funnel with test point, testing (all as shown in electrical plate No 5 and commissioning all as specified and as directed. Note : On testing, after completion, if the earth resistance below 1 Ohms is not obtained, earthing will rejuvenated at no extra cost till the desired earth resistance is obtined.
M&L for GI strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle complete all as specified and as directed.
M&L for copper strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle complete all as specified and as directed. Note : Cost of insulating saddle for fixing of copper strip on wall/roof/floor etc shall be included in quoted rates.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and as directed.
Supply and fixing GI funnel complete with wire mesh for earthing water pipe complete all as specified and as directed.
M&L for hardcore of broken stone or boulder gauge 45mm over installation complete all as specified and as directed.
M/s DEVI DAYAL CONSTRUCTION CO
M/S JIWAN KUMAR MITTAL
M/S A.K. ENGINEERS
M/S S S CONSTRUCTION
M/S United Builders
M/s R L PAREEK
KISHORE ENTERPRISES
Ms Kamal Kant Agarwal
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .