| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC | L1 | Accepted-AOC Reasonable | |
| 2 | L2₹9.6 L+₹51,330 (5.63%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance BEING OTHER THAN L1 | |
| 3 | L3₹11.9 L+₹2.8 L (30.4%)Rejected-Finance B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance BEING OTHER THAN L1 | |
| 4 | L4₹12.0 L+₹2.9 L (31.5%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | L4 | Rejected-Finance BEING OTHER THAN L1 | |
| 5 | L5₹12.5 L+₹3.4 L (37.0%)Rejected-Finance | L5 | Rejected-Finance BEING OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹29,000
Closing Date
8 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PATHANKOT
GE (AF) PATHANKOT-145001
DAY TO DAY MAINTENANCE OF ELECTRICAL SYSTEM AND CONNECTED ITEMS AT DOMESTIC AREA AT AIR FORCE STATION PATHANKOT
2020_MES_370954_1
GE/PAF-18/2020-21
Open Tender
Support/Maintenance Service
Item Rate
270 days
GE (AF) PATHANKOT
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) PATHANKOT
₹29,000
Yes
30 Sept 2020
21 Aug 2020
10 Sept 2020
21 Aug 2020
8 Sept 2020
2 Sept 2020
60 days
Amount
Carrying out comprehensive maintenance of day to day for domestic area (For No. 1 area) internal eletrification complaints by Collection from complaint cell daily between 9.00 am to 10.00 am and attending of complaints of domestic area after rectifying complaints job card will be return on same day. Defects of the items such as switches, fuse wires, DB, MCB (light/ power), lamp holder (bracket, pandent, batten) bell/buzzer, push button, ceiling rose, capacitors and other similar electrical items/fittings, repairing of geysers/ solar heater system etc including providing of small pieces of electrical wire of size 1.5 sqmm to 10 sqmm single core/ two core and length not exceding 1.5 mtrs complete all as specified and directed by Engineer-in-Charge (Note :- (i) any accessories as mentioned above found unserviceable shall be replaced under respective items of this Sch. seperately and cost of labour for these item shall deemed to be included under Srl item 1. However any minor requirement essential for making overall system serviceable is deemed to be included in the quoted rate of this item. Note:- i) Contractor shall provide his or authorised rep Cell/mobile No. and local address to contact and communicate the message for any break down/ Complaint received on Cell phone and contractor's rep will visit the office twice a day (0930 Hrs and 1430 Hrs) to collect the day to day complaints of any nature/type. (ii) Penalty for not rectifying the defect in time(within 72 hrs) will be charged to contractor and the amount of penalty @ Rs 1000/- per complaint will deducted from the due payment of contract. (iii) Manpower requirement for attending and completing day to day complaints will be depending upon the number of complaints which may vary day to day and cost of same is deemed to be included in quoted rate. Contractor is advised to quote accordingly. (iv) Complaints will be treated as rectified only after user's "Satisfactory slip "will be produced by contractor to concerned JE E/M/Rep of MES. (v) Old material obtained from replaced items under this item shall be contractor's property and will be measured as per Schedule of credit. (vi) Cost of minor spares i.e, insulation tape, lugs, thimbles etc are deemed to be included in the quoted rate. Labour required to carryout the maint / repairs for all repairs including testing and commissioning shall be deemed to be included in item rate as quoted by the contractor.Items replaced shall be measured and paid seperately . (vii) Cost of T&P i.e, ladders, tools, brazing, welding, soldering required and transportation is deemed to be included in quoted rates. (viii) Making good the area / cleaning the area will be mandatory for the contractor & failing which penalty of Rs. 2000/- will be charged at each up stance
All as per item No. 1 above, but for No. 2 & 3 area, complete all as specified and directed by Engineer-in-Charge
M&L for the following items no 3.00 to 3.42 in replacement if required against Srl Item No 1 & 2 above, PVC wire single core multi strnderd FRLS of size 1.5 sqmm
PVC wire single core multi strnderd FRLS of size 2.5 sqmm complete all as directed by Engr-in-charge
PVC wire single core multi strnderd FRLS of size 4.0 sqmm complete all as directed by Engr-in-charge
PVC wire single core multi strnderd FRLS of size 6 sqmm complete all as directed by Engr-in-charge
Switch piano flush button singel pole one way 5 amps 230 V all as specified and directed by Engineer-in-Charge
Switch piano flush button singel pole one way 15 amps 230 V all as specified and directed by Engineer-in-Charge
Bell push flush button single pole two way 5 amps 230 V all as specified and directed by Engineer-in-Charge
Socket 5 amps 5 pin flush type 230 Volts all as specified and directed by Engineer-in-Charge
Socket outlet 6 pin 5 and 15 amps multi purpose 2 in 1 flush type 230 Volts all as specified and directed by Engineer-in-Charge
Ceiling rose surface bakelite 3 terminals all as specified and directed by Engineer-in-Charge
Lamp holder insulated body with back plate for batten fittings all as specified and directed by Engineer-in-Charge
Bell ding dong type 230 Volts single pole all as specified and directed by Engineer-in-Charge
Choke electronic 36 watts 230 volts all as specified and directed by Engineer-in-Charge.
Choke electronic 28 watts 230 volts with plastic housing complete all as directed by Engr-in-charge
Heavy duty vaccum pressure impergenated copper ballast (VPIT) for CFL 9/10/11 watts complete all as directed by Engr-in-charge
Heavy duty vaccum pressure impergenated copper ballast (VPIT) for CFL 14/18 watts complete all as directed by Engr-in-charge.
Heavy duty vaccum pressure impergenated copper ballast (VPIT) for CFL 36 watts complete all as directed by Engr-in-charge
Compact fluorescent lamp 9/10/11 watts 230 volts 6500 K, 2 pin complete all as directed by Engr-in-charge
Compact fluorescent lamp 18 watts 230 volts 6500 K, 2 pin complete all as directed by Engr-in-charge
Compact fluorescent lamp 36 watts 230 volts 6500 K, 2 pincomplete all as directed by Engr-in-charge.
Tube rod 4' x 36/40 Watt 230 Volts all as directed by Engr-in-Charge
Tube rod 4' x 28 Watt 230 Volts all as directed by Engr-in-Charge
Lamp holder suitable for CFL lamp any type upto 18 watts as per site requirement complete all as directed by Engr-in-charge
Lamp holder suitable for CFL lamp any type upto 36 watts as per site requirement complete all as directed by Engr-in-charge
Spring loaded rotary type bipin holder suitable for tube light fittings complete all as directed by Engr-in-charge
Starter AC 230 Volts suitable for fluorescent tube light fittings complete all as directed by Engr-in-charge
Fan regulator electronic, step type suitable to control speed of fan from 0 to 100% complete all as directed by Engr-in-charge
Plug top 3 pin 5 amps AC 230 Volts complete all as directed by Engr-in-charge
Plug top 3 pin 16 amps AC 230 Volts complete all as directed by Engr-in-charge
Cord flexible PVC insulated and over all sheathed, 3 core, flexible copper conductor of size 1.50 sqmm, cut to size all as required at site complete all as directed by Engr-in-charge
Plastic laminated top sheet cover 3 mm thick of size 5"x5" all as required at site including cutting for fixing the existing switches, sockets, fan regulators & drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box complete all as directed by Engr-in-charge
Plastic laminated top sheet cover 3 mm thick of size 8"x5" all as required at site including cutting for fixing the existing switches, sockets, fan regulators & drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box complete all as directed by Engr-in-charge
Plastic laminated top sheet cover 3 mm thick of size 11"x9" all as required at site including cutting for fixing the existing switches, sockets, fan regulators & drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box complete all as directed by Engr-in-charge
Plastic laminated top sheet cover 3 mm thick of size 13"x11" all as required at site including cutting for fixing the existing switches, sockets, fan regulators & drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box complete all as directed by Engr-in-charge
LED box type fitting pre-wired for LED tube with enegry efficient LED tube extruded aluminium heat sink & high efficiency diffuser 4 Ft version for 16/20 Watts, including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required complete all as directed by Engr-in-charge
Recess mounted LED fitting with high transmittance polycarbonate diffuser 36 watt fit to 600x600 mm modular/pop/gypsum ceilling complete with including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required complete all as directed by Engr-in-charge
Energy saving new generation 10 W LED bulk head luminaire with opal diffuser watt suitable for 10 W LED 6000K complete with LED lamp including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required complete all as directed by Engr-in-charge
Modular type switch 6 Amp one module complete all as directed by Engr-in-charge
Modular type switch 16 Amp one module complete all as directed by Engr-in-charge
Modular type Socket 6 Amp two module complete all as directed by Engr-in-charge
Modular type Socket 16 Amp two module complete all as directed by Engr-in-charge
Modular type fan regulator 6 Amp two module step type complete all as directed by Engr-in-charge
Modular type bell push 6 Amp one module complete all as directed by Engr-in-charge
Supply, fixing and Testing TPN DB (VTPN) 4 way 415 Volts 50 Hz indoor type double door sheet metal enclosure IP-43 DB's IK-09 flush mounted with 250 Amp Copper busbar for each phase with two neutral bar & two earthbar and cable ties for cable management including MCCB 100 Amps,ICs=100%ICu, 25KA four pole as in comer including connecting terminal strip complete and SP MCBs as out going etc complete pre wired with suitable size copper conductor. The DB's shall hold type test certificate (CPRI) as per IEC 61439-3 complete all as specified and directed by Eng-in-charge including taking out old unserviceable DB and removing from site.
Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral 230 Volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 230 Volts 4 way, including suitable size copper bus bar and neutral link Make: Legrand /Hager/ Merlin Gerin multi-9 fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .
Supply and replacement MCB single pole 230 Volts any rating from 5 to 30 amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as directed by Engr-in-charge
Supply and replacement MCB SPN 230 Volts any rating from 5 to 30 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as directed by Engr-in-charge .
Supply and replacement MCB three/four pole 415 volts any rating up to 63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as directed by Engr-in-charge
Sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 20 amps 230 Volts, complete with one single pole MCB of 20 amps earthing complete all as directed by Engr-in-charge .
Supply and fix Capacitor AC 415 volts 3.15 mfd 50 Hz complete all as specified and directed by Engineer-in-Charge.
Supply and fix Capacitor AC 415 volts 2.5 mfd 50 Hz complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminiuim conductor multistranded of size 10 Sqmm served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire one twin core cable flat or circular complete all as specified by the Engineer in charge.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminiuim conductor multistranded of size 16 Sqmm served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire one twin core cable flat or circular complete all as specified by the Engineer in charge.
Replacemet of old usnerviceable syphon assembly for geyser having hole (6/7/9) all complete as per existing make & size as per site requirement all complete all as directed by Engr-in-Charge.
Replacement of old unserviceable heating element with heating element AC 230 volt of rating 1500 watt complete all as directed by Engr-in-charge
All as per Srl item No 16 above but of rating 2000 Watt capacity complete all as directed by Engr-in-charge
Replacement of old unserviceable Thermostat switch with Thermostat switch for geyser AC 230 volt adjustable range from 60 degree celslus complete all as directed by Engr-in-charge
Replacement of old unserviceable PVC connection with PVC connection 15mm bore (450mm long) complete with brass nuts at water temprature upto100 degree celceus complete all as directed by Engr-in-charge
Replacement of fusible/safety plug melting at 95-100 degree centigrade suitable for any type/make of Geyser complete all as directed by Engr-in-charge.
Cleaning thoroughly gyser 25/50 Ltr capacity with Kerosene Oil and painting with two coat of synthetic enamelled paint including preparation of surfaces, change the U/S lamp any type and writing MES No after painting complete all as specified & directed by Engineer-in-Charge
Replacement of old unserviceable bolt with bolt 12mm 100mm long complete all as directed by Engr-in-charge (Note- bolt shall be grouted with hammer drill only).
Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.3mm thick busied directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shora all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 5 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. Note:-(i) Main earthing lead from earth plate electrode to test point upto length of 7.5 meters length shall deem to be included in the unit rate quoted against this item . (ii) GI protection pipe & earthing lead beyond 7.5 metre shall be measured and paid for seperately under appropriate item of Sch A part-IV (Sec-I) . (iii) On testing after completion if the desired resistenance is not obtained the contrator shall redo the earthing without any extra cost to the department .
S&F in replacement LED avaiation light luminaires ,integral LED aviation light comprising of aluminium housing with polycarbonate enclosure including connecting electricaly to existing location using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required. and directed by Engr-in-Charge.
Fixing only switch piano flush button single pole one way 5 amps 230 Volts complete all as specified and directed. (Switch shall be issued under Sch ,B,)
Fixing only tube rod 20/28/36/ 40 Watt /LED tube rod 16W/20W, 230 Volts. complete all as specified and directed. (tube rod 20/28/36/ 40 Watt /LED tube rod 16W/20W shall be issued under Sch ,B,)
Fixing only starter AC 230 Volts suitable for fluorescent tube light fittings complete all as specified and directed. (Starter AC 230 Volts shall be issued under Sch ,B,)
Fixing only fan regulator electronic type complete all as specified and directed. (fan regulator shall be issued under Sch ,B,)
Fixing only plug & socket earth type MCB 25 A complete all as specified and directed. (plug & socket shall be issued under Sch ,B,)
Fixing only MCBs any capacity complete all as specified and directed. (MCBs shall be issued under Sch ,B,)
Fixing only Ballast any type complete all as specified and directed. (Ballast shall be issued under Sch ,B,)
Fixing only service cable any size complete all as specified and directed. (service cable shall be issued under Sch ,B,)
Fixing only plug top any type complete all as specified and directed. ( plug top shall be issued under Sch ,B,)
Taking down carefully aluminum/copper point wiring (light fan socket or power) complete with fitting such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCB'S, Main switch from control board and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified keeping aside regulators/ light fitting/ MCBs serviceable/ unserviceable items for reuse with in the same bldg or deposited to MES store yard
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit Medium grade with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size, & as directed by Engr in Charge & 3mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified.
All as per srl item No-35 above but in existing conduit existing & CI/MS sunk boxes
All as per srl item No-35 above but for one light point controlled by 2 nos two way switches.
All as per srl item No-37 above but in existing conduit & CI/MS sunk boxes
All as per srl item No-35 above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit.
All as per srl item No-39 above but in existing conduit & CI/MS sunk boxes
All as per srl item No-35 above but for one 3 pin 5A socket outlet independent controlled by one switch.
All as per srl item No-41 above but in existing conduit & CI/MS sunk boxes
All as per srl item No-35 above but for one 5A socket outlet on the same board controlled by one switch.
Submain wiring with two single core FRLS insulated flexible copper conductor cable of size 4 sqmm and one single core PVC FRLS insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit medium grade cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed by Engr-in- charge.
All as per srl item No-44 above but in existing conduit & CI/MS sunk boxes
Submain wiring with two single core FRLS insulated flexible copper conductor cable of size 6 sqmm and one single core PVC FRLS insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit medium grade cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed by Engr-in- charge.
All as per srl item No-46above but in existing conduit & CI/MS sunk boxes
M/S SHRI RAM BUILDERS
SATISH AND CO
Vijay Kumar Contractor and Engineers
M/S V K TRADERS
INDERJIT SINGH
M/S SATYA CONSTRUCTIONS
kailu construction co
M/S DUGGAL CONSTRUCTION CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .