Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹24.8 L+₹1.7 L (7.41%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹26.5 L+₹3.5 L (15.2%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹68,000
Closing Date
1 Jul 2024, 6:00 pmClosed
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
REP REPLACE AND MAINT OF INT ELEC WKS INCL DBs SUB MAIN GEYSERS KWH MTR ETC AT MD ACCN OF OFFRS JCOs ORs AND DEF CIV AT MADALY LINE QMTI MAP ASHOK NAGAR AND REP REPLACE AND MAINT OF FIRE ALARM SYS AND CONNECTED WKS AT MIL HOSP GE MH AND RH KHADKI
2024_MES_653113_2
8551/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹68,000
10 Sept 2024
11 Jun 2024
3 Jul 2024
11 Jun 2024
1 Jul 2024
18 Jun 2024
11 Jun 2024 - 24 Jun 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking into credit (credit for above items shall be made as per condition laid down under schedule of credit seprately) and making good disturbed surfaces of walls, floors etc complete all as specified.
M&L for point wiring using approved colour coding as per IS (red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area,single core, PVC insulated and unsheathed FRLS cable1100 volts grade , ISI-694 (1990) marked with valid CML No in and including medium grade,PVC casing & capping of suitable size on walls/roof/floor etc, ISI marked with suitable accessories , mild steel/ pressed steel sunken box of 1.2 mm thick and 60 mm deep (with earth dolly) duly painted with two coat of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide externally, covered with 3 mm thick plasticlaminated sheet cover for fixing of switches, sockets and fan regulator etc, including PVC insulated multistranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engr-in-Charge for the following:-
One fan/light /bell point controlled by one switch/bell push
One switch socket outlet 5 Amps on independent board
One socket outlet 5 Amps on the same board
All as per item No 2 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated but unsheathed copper conductor FRLS cable 1100Volts grade and 2.5 sqmm as earth continuity conductor for one switch socket outlet 15 Amps on independent board complete all as specified and directed by Engr-in-Charge.
All as per item No 2 here-in-before but with 4 Sqmm PVC insulated multistranded copper conductor cable including 4 sqmm PVC insulated but unsheathed copper conductor FRLS cable 1100Volts grade and 4 sqmm as earth continuity conductor for power socket on independent board complete all as specified and directed by Engr-in-Charge.
M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC Cassing capping of suitable size including 4.0 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including chislling/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface including taking down old unserviceable/burnt wiring of any type or size complete all as directed by Engr-in-Charge. Note: Two single core cable, earth wire and PVC conduit shall be measured as one length.
All as per item No 05 above but of 6 Sqmm
Supply and fix in repair ceiling rose surface bakelite with three terminals type complete all as specified and directed.
Supply and fix in repairs switch piano type one way 6 Amps flush type, 240volt AC complete all as specified and directed.
Supply and fix in repairs socket outlet 2 in1,3 pin 5 Amps complete all as specified and directed.
Supply and fix in repairs Switch Socket Combination (SSC) 2 in 1, 3 pin, 5 Amps flush type, 240volt AC complete all as specified and directed.
Supply and fix in repairs switch piano type 16 Amps flush type, 240volt AC complete all as specified and directed.
Supply and fix in repairs socket outlet 2 in 1, 3/ 5 pin 16 Amps flush type complete all as specified and directed.
Supply and fix in repairs Switch Socket Combination (SSC) 2 in 1, 3/5 pin, 16 Amps flush type, 240volt AC complete all as specified and directed.
Supply and fix in repairs bell push, flush type, 6 Amp flush type, 240volt AC complete all as specified and directed.
Supply and fix in repairs switch piano type two way 6 Amps flush type, 240volt AC complete all as specified and directed.
Supply and fix in repairs Bell push, modular type, 6 Amp flush type, 240volt AC complete all as specified and directed.
Supply and fix in repair modular switch 1 way 6A 1 module complete all as specified and directed.
Supply and fix in repair modular switch 2 way 6A 1 module complete all as specified and directed.
Supply and fix in repair modular socket 6A 2/3 pin combined 2 module complete all as specified and directed.
Supply and fix in repair modular socket 6A /16A 2/3 pin combined 2 module complete all as specified and directed.
Supply and fix in repair modular fan regulator,120 watt - 2 module complete all as specified and directed.
Supply and fix in repair stepped type electronic fan regulator 120 watt, 240 volt flush type on the existing phenolic laminated sheet complete all as specified and directed.
Supply and fix in repair electric bell Ding Dong, AC 230 volts complete all as specified and directed.
Supply and fix in repair Modular white cover plate with frame of following sizes complete all as specified and directed.
1 module
2 module
3 module
4 module
6 module
8 module
Supply and fixing replacement of RCCB 63 A, four pole, 30 mA complete all as specified and directed by Engr-in-Charge. Make: Hager/L & T/Standard
Supply and fix in industrial wall mounted plug socket suitable fotr IP 44 degree of protection of 32Amps rating 3p+N +E complete all as specified and directed. Make: L&T cat part DBPPS563SD or other equivalent make.
S & F sheet metal enclosures for double door distribution board factory made duly painted of following capacity with 200 amps rated bus bar, suitable for fixing MCB /Isolators complete all as specified Make:L & T/legrand/Havells or equivalent make.
12 way SPN , 240V
8 way SPN 240V
4 way TPN ,415V
8 way TPN ,415V
S & F MCCB 125 Amps, 4 pole, breaking capacity 16 KA, 415 V adjustable type complete all as specified of capacity. Make: L &T /Legrand/Indoasian/Standard.
All as per item No 28 Above but of capacity 100 Amps.
Supply and fixing miniature circuit breaker (MCB) of following current carrying capacity, in the MCB DB complete with connection testing and commissioning. Make L &T /Legrand/Havells
SP 5/6 to 32 AMP, 240V, 10 KA 'B' curve
SP 40 AMP, 240V, 10 KA 'B' curve
SPN 32 Amps, 240V, 10 KA 'B' curve
SPN 40 Amps, 240V, 10 KA 'B' curve
TPN 63 Amps, 240V, 10 KA 'B' curve
Taking down old unserviceable fitting and S & F wall mounted extruded aluminium housing high quality indoor batten of following capacity colour temperature 6500 K (4' long) lumen 2000 -3000, PF> 0.9, THD less 15% diffused connecting with three core flexible copper wire from connector to ceiling rose/angle holder as per existing site requirement as directed by Engr-in-Charge. Make : Havells/Wipro/Halonix or eqivalent
LED tubelight fitting of 20 watt/22 watt, 4 feet long
LED tubelight fitting of 10 watt, 2 feet long
Taking down old unserviceable fitting and S & F wall mounted high quality indoor wall bracket light cylinderical/oval shape aesthetically designed fitting with B22D lamp holder and 12 Watt bulb temp range 4000k to 6500 K as per site requirement connecting with three core flexible copper wire as directed by Engr-in-charge. Make : Halonix Cat No: HLWB-01-B22 or equivalent Havells/Wipro
Taking down old unserviceable bldg security light S&F fix high efficent LED building security light 30 watt, 230 V, lumen 2000 -3000, PF> 0.9, THD less 10%, made of pressutre cast aluminuim housing with high power LEDs, lens and toughened glass IP 66 connecting with three core flexible copper wire from connect to ceiling rose. Make : Halonix, Bajaj, Havells or equivalent.
S & F in repair bracket for mounting building security light made out of 40 mm dia Light Grade GI pipe bend in angle with holding MS clamps two Nos each bracket of size 25x3 mm including screw etc for fixing complete all as specified and directed by Engr-in-Charge
M & L for repairs /re-fixing on exiting or new location to storage type electric water heater (geyser) of storage capacity 25/35/50 ltrs of any make comprising of the following works mentioned here under againt Ser Nos (a) to (f) at different locations:- (a) Inspection, taking down, opening (dismantling) descaling, brushing, cleaning of storage tank (b) Examine water tightness of storage tank after cleaning. (c) Carry out operation of all stop cocks, pressure reducing valves etc. to ensures free movement of the working parts. (d) S & F Replacement of the rubber / PVC gasket to ensure water tightness. (e) Checking of safety valve (f) Testing of geysers after repairs.
S & F in repairs thermal cut out ISI marked temp range 50-80/90 degree as required at site for geyser of capacity 25/35/50 Ltr of any make complete all as directed by Engr-in-charge
S & F in repairs of safety valve/high pressure valve ISI marked as per site requirement or complete all as per directed by Engr-in-Charge.
S & F in repairs heating element of following rating as required at site including rubber washers all as specified and directed by Engr-in-charge.
1/1.5 KW,240 volt
2 KW ,240 volt
S & F in repairs of PVC pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 cm long for cold water connection complete all as specified and directed by Engr-in-Charge
S & Fixing in repairs metal braided PVC/CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 45 CM long for hot water connection complete all as specified and directed by Engr-in-Charge
S & Fixing in repairs, non return valve 15 mm dia of brass, ISI marked complete all as specified and directed by Engr-in-charge.
S & F stop valve, cast copper alloy screw down high pressure crutch handle, screwed both end for iron pipe suitable for 15 mm bore complete all as specified and directed by Engr-in-Charge
M & L for repairing and replacment of unserviceable copper container of capacity 25/50 Ltrs of solar water heater of any type after completion of work testing the heater complete all as specified and directed by Engr-in-Charge
Copper container 50/100 ltr
Copper container capacity 25 Ltrs of water heater (gyeser)
M & L for rewinding of Ceiling Fan, Exhaust Fan and Air circulator of any type/make by split opening the fan carrying cutting the burnt winding and cleaning the slots and rewinding with super enamelled copper winding wire appropriate gauge including connection, capacitor base and testing complete all as specified and directed by Engr-in-Charge. Note: Bearing, fan canopy, capacitor, down rod etc will be measured and paid separately under relevant item of schedule.
Ceiling Fan of 1200/1400 mm sweep
Exhaust Fan of sweep 275-300 mm
Exhaust Fan of sweep 350-450 mm
Supply only ball bearing (DE/NDE) to match the existing make suitable for 1200/1400 mm sweep ceiling fan including greasing complete all as specified and directed by Engr-in-Charge. Make: SKF/NBC
Supply only ball bearing suitable for 275-450 mm exhaust fan complete all as specified and directed Make : SKF/NBC or equivalent
Supply only fan capacitor of following capacity
Capacitor 2.5 mfd
Capacitor 4 mfd
Supply only, rubber yoke, MS clamps, bolts nuts with split pin suitable for ceiling fan 1200 /1400 mm sweep complete all as specified and as directed by Engr-in-charge.
Supply only gunmetal bush suitable size for ceiling fan 1200 /1400 mm sweep complete all as specifed and directed by Engr-in-Charge.
Supply only fan down rod of following length with white enammbeled painted with both side hole for hanging fan of sweep 1200/1400mm sweep complete all as specified and directed by Engr-in-Charge
1 ft long
2 ft long
Supply only fan canopy set off white /white coloured as per colour of ceiling fan of sweep1200/1400mm complete all as specified and directed.
Taking down old/new electric meter three phase/single phase, taking it to testing lab as approved by State electricity board or NABL approved lab calibarating it and reparing it if rejected in testing parameters of the testing authorities. Refixing the meter back to the site with proper nut bolts, washers/fastners and suitable size of connecting PVC copper wire as per required length. Note:- (i) Test certificate/calibration report of the electric meters to provided by the contracter (ii) The meter is to be fixed on wooden board of thickness not less than 8mm of size as per the site requirement. (iii) The rates are all inclusive of dismantling, transporting, repairing, calibrating and refixing back to its original place. (iv) Contractor has to install new meter issued from the dept befour dismantling the old meter. (v) The meters will not be given in complete lot, meters will be given as and when required basis or as directed by the Engr-in-charge. (vi) All minor spares such as CT's power convertor, circuit board,(PCB), resistors, terminal covers etc are included in quoted rates.
M & L for replacement of PVC polycarbonate rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of following size make cutting for fixing existing switches, sockets, regulators and make necessary connection and testing complete all as specified and directed by Engr-in-Charge.
100 x 100 mm and 50 mm deep
200 x 150 x 50 mm deep
250 x 200 x 50 mm deep
150 x 150 x 50 mm deep
Decarbonizing of indoor MCB / meter box any type removing unserviceable MCCBs, burnt busbars, unserviceable indicator lamps, unserviceable Ammeter, unserviceable Volt meter, replacing burnt, damaged bus bar of any size and fixing proper hanging front and rear openings, welding of hinges including welding of brokieng MS sheet using extra sheets replace burnt thimbles with new existing size thimbles replacing with new MCCB & MCBs, powder coating painting with suitable 'U' type gasket to make it dust and vermin proof, providing fancy locks incluidng dismantling the existing connected cables and re-connecting the same cables complete all as specified and directed by Engr -in- charge. Note : (i) MCCBs, indicator lamps, Ammeter, Volt meter, will be measured & paid separately as supply only. (ii) Necessary MS sheet and welding incuding sealing the meter with sealing Lead/PVC seal with MES Emblum empossing on it all are inclusive coated rate. (iii) Required size of neutral bus bars including coated rate. (iv) Required size of copper cable for connecting MCBs and meters are including quoted rate.
Dismantling and taking out ABC type Fire Extinguisher of capacity 6 kgs by removing hose, valve assembly and depressurizing the extinguisher and transporting to approved testing Lab/workshop and carry out complete over hauling of cylinder, valves etc including purging, testing and refilling the cylinder upto 6 kg (as per OEM recommendations) ABC powder as per IS 2878 complete including one coat of synthetic enamel paint on the cylinder with appropriate colour, labelling and transporting back to site, installing on its existing position complete all as directed by the Engr-in-charge.
Dismantling and taking out Fire Extinguisher CO2 type 4.5 Kg capacity removing discharge hose nozzles and transporting to approved testing lab/workshop and carry out complete over hauling of cylinder, plunger nozzles,valves etc including purging, high pressure testing and refilling the cylinder upto 4.5kg net CO2 all as per IS 2878 complete including one coat of synthetic enamel paint on the cylinder with appropriate colour, labelling and transporting back to site, installing on its existing position complete all as directed by the Engr-in-charge.
Servicing and maintenance of Micro Processer based fire alarm control panel of make Apollo installed at MH Khadki Phase-I building, comprising of six loop data card, battery, LCD/LED display panel, buzzers with software programs etc, including testing by OEM all as specified and as directed. The details of the Fire alarm panel are as under:- (a) Main Control panel of Fire Alarm System - (01+02) Nos, Make : Apollo -TD1 (b) Heat and Smoke detectors - 661 Nos, Make :Agni (c) Battery 12V, 7AH to 10 AH - 24 No, Make : Exide. (d) Response indicator - 221 Nos. , Make :Agni (e) Manual Call points- 40 Nos Make : XP95 (f) Dual tone electronic Hooter- 06 Nos , Make Agni (g) Repeater Panel - 09 Nos, Make :Apollo (h) Control Module for AHU - 12 Nos , Make Apollo Notes :- (i) The Rates are inclusive of regular inspection of authorised OEM, once in a month. (ii) The maint and servicing includes clearing the fault in loop wiring, cleaning the heat/smoke detectors with blowers, response indicator, MCP, Sounder cum Strobe with control module etc all as directed by Engr-in-Charge. (iii) Major Spares required for maintenance of the above panel shall be measured and paid separately under relevant item.
Supply, installation, commissioning and testing of microprocessor based programmable detection control panel Apollo -TD1(Teledataone)/Global octo+ upto 5 loop addresable fire alarm panel with IP -30 protection having loops expandable from 1 to 9 loops complete including dismantling the old panel all as specified and directed . The panel comprises of following techinical parameters :- (i) Primary voltage - 230Volts AC (ii) Minimum operating voltage - 21.6Volts (iii) Dimensions of panel - 410X410X120mm (iv) Loop short circuit protection (v) 14 front LED's (vi) Optional integrated 56 LED fire zone indication (vii) Supervised AUX power supply output 24 volts DC with short circuit protection (viii) Graphic touch screen display (ix) Upto 126 addressable device for loop (Apollo XP95/Discovery) (x) Battery capacity 2X7.2 Ah or 2X 17 Ah with EN54-4 charger management. (xi) 1 RS -232/micro USB for programming (xii) The system is provided with 32 bit microprocessor with RAM Note :- (i) The panel should be installed as per the manufacturer's instructions. (ii) Complete testing of the Fire Alarm system should be given by the contractor in the presence of Engr-in-charge and user rep after installation and maintenance of the complete fire alarm system. (iii) The cost is inclusive of all the minor spares required for functioning of the Fire alarm panel.
Supply, installation,commissioning and testing of Apollo - TD1 addressable single loop fire alarm repeater panel with primary supply voltage 230volts AC (max upto 260 volts) and secondary supply upto voltage 30 DC, the panel should be competable in operating temperature upto 50 degree centigrate and operating humidity level less than 95 % (non condensed) with graphic touch LCD display complete including dismantling the old panel all as specified and directed. Note :- (i) The panel should be as per the OEM recommendations. (ii) Site inspection for maintenance of Fire alarm system is necessary before quoting the tender.
Supply only Apollo addressable smoke detector complete including dismantling the old unsv SD all as specified and directed.
Supply only Apollo addressable manual Call point including dismantling the old unsv call points complete all as specified and directed.
Supply only Apollo addressable sounder complete including dismantling the old unsv sounders all as specified and directed.
Servicing and Maintainence of Micro processer based Fire alarm control panel of Make Zicom installed at MH kirkee Phase -II building having six loop data card, battery, LCD panel, buzzers with required software programs etc, including testing by OEM complete all as specified and directed. The details of the Fire alarm panel are as under :- (a) Fire alarm Main Panel - 28 Nos, Make : Agni/Ravel/Zicom (b) Heat and smoke detectors - 1623 Nos Make : Agni/ravel/System Sensor (c) Battery 12V, 7AH/10 AH - 56 Nos , Make : Exide (d) Response indicator - 600 Nos Make :Agni/Ravel (e) Manual Call points- 48 Nos Make : Agni (f) Hooter - 48 Nos, Make Agni/Ravel/Zicom (g) Control Modual for AHU - 24 Nos Make :Agni/Ravel/Zicom Notes :- (i) The Rates are inclusive of regular inspection of authorised OEM, once in a month. (ii) The maint and servicing includes clearing the fault in loop wiring , cleaning the heat/smoke detectors with blowers, response indicator, MCP, Sounder cum Strobe with control module etc all as directed by Engr-in-Charge. (iii) Spares required for maintenance of the above panel shall be measured and paid separately under relevant item.
Supply, Installation,commissioning and testing of Ravel/Agni (RE-102/104), 4 zone microprocessor based Conventional Fire alarm control panel. The panel is capable to operate conventional input devices such as 2 wire smoke detectors , pull stations and other normally open contact devices. The out puts include notification appliance circuits(sounders), Three form C relays 2 for alarm, 1 for fault and RS485 port to interface with remote annunciator (optional). It supervises all wiring, AC voltage and battery level. complete including dismantling the old panel all as specified and directed. The panel comprises of the following Features:- (i) Operates on 220 volts, 50 Hz AC supply (ii) Stand by battery back up withn built in charging (iii) Low battery visual warning with audiable tone (iv) Zone isolation facility with loop voltage cut off (v) 16X2 LCD display and Error free Fire/Fault status in unambiguos colored LED indication. (vi) Programmable auto silence and Key pad lock. (vii) Compatible to all types of conventional detectors
Supply only Agni/System sensor/Zicom smoke detector complete including dismantling the old Smoke detector complete all as specified and directed.
Supply only Ravel/Agni/Zicom system sensor manual call point complete including dismantling the old call point complete all as specified and directed.
Supply only Agni/Zicom system sensor sounder cum flasher complete including dismantling the old sounders /flashers complete all as specified and directed.
Supply only 12 volt 7 AH/10AH battery complete including dismantling the old batteries all as specified and directed.
Supply, draw, connecting, testing and commissioning of 2 core 1.5 sq mm stranded copper conductor, PVC insulated PVC sheathed FRLS, flexible armoured cable laid on ceiling/wall clamped with aluminium clamps/ drawn in ERW pipe complete all as specified and directed . Note :- (i) The cables are to be drawn through the false ceilings, laid in floors, fixed to walls as per the site requirements. (ii) The conduits are to be measured and paid seperately under relevent item.
Supply and laying of mild steel stove enameled black conduit alongwith the accessories such as tees, bends, elbows, bell mouth ends and all fixing accessories such as couplers, locknuts, saddles, pipe hook etc. on surface/recess including painting, in case of recessed conduit, cutting the wall and making good the same for of recessed conduit of size 25 mm dia.complete all as specified and directed.
AMAN ENGINEERING AND ELECTIRICALS WORKS
SHREE VAIBHAV ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .