Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC | L1 | Accepted-AOC Awarded Being Lowest Bidder | |
| 2 | L2₹25.8 L+₹86,077 (3.45%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹29.3 L+₹4.4 L (17.5%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
20 Jul 2022, 6:00 pmClosed
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Repair/maint of Desert coolers Deep freezer s voltage stabilizer window and split AC Refrigeretor and water cooler of various capacities for cooling appliances Held at ACCS Area under GE (N) Ahmednagar
2022_MES_529400_1
8637 / E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Ahmednagar
Class D Cat a (ii)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹60,000
Yes
27 Jul 2022
8 Jun 2022
22 Jul 2022
8 Jun 2022
20 Jul 2022
21 Jun 2022
Amount
Disconnecting burnt out compressor from existing electric and pipe line connections of Refrigerator of capacity 165 / 175 / 210 litres of any make / location, transporting and replacing the same with factory / company made new compressor including connecting suction and discharge lines by copper brazing, pressure testing with the help of nitrogen gas and flushing out the oil in condensor cooling coil and gas charging etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 1 (here-in-before) but Refrigerator of capacity 286 / 300 / 310 litres etc complete all as specified and directed by Engineer-in-Charge
All as per item No. 1 (here-in-before) but Water cooler of capacity 40 / 80 litres etc complete all as specified and directed by Engineer-in-Charge
All as per item No. 1 (here-in-before) but Water cooler of capacity 60 / 120 / 150 litres etc complete all as specified and directed by Engineer-in-Charge
All as per item No. 1 (here-in-before) but Deep freezer of capacity 205 to 310 litres etc complete all as specified and directed by Engineer-in-Charge
All as per item No. 1 (here-in-before) but Window / Split type AC of capacity 1.5 TR etc complete all as specified and directed by Engineer-in-Charge
All as per item No. 1 (here-in-before) but Window / Split type AC of capacity 2TR etc complete all as specified and directed by Engineer-in-Charge
All as per item No. 1 (here-in-before) but Cassette type AC of capacity 4TR etc complete all as specified and directed by Engineer-in-Charge
Supply only fan motor / condensor motor and replacing the same with new fan / condensor motor 230 Volts, 50 Hz, SP suitable for water cooler of capacity 40 / 80, 60 / 120 and 60 / 150 litres including connecting and testing etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 9 (here-in-before) but of 230 Volts, 50 Hz, SP suitable for frost free refrigerator of capacity 286 / 300 / 310 litres etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 9 (here-in-before) but suitable for window type AC of capacity 1.5 / 2 TR etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 9 (here-in-before) but suitable for split type AC out door unit of capacity 1.5 / 2 TR etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 9 (here-in-before) but for split type AC in door unit 1.5/2 TR capacity etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 9 (here-in-before) but of 230 Volts, 50 Hz, SP suitable for deep freezer of capacity 205 to 310 ltrs cap etc complete all as specified and directed by Engineer-in-Charge.
Supply and charging only refrigerent gas of required HD i.e hydrocarbon, 134 a, R-22 or R-12 or any latest version for Refrigerators of capacity 165 to 310 ltr capacity including cutting copper pipe and sealing by brazing etc after charging gas as required and leak testing etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 15 above but for Water coolers 40 / 80 to 60 / 120 ltr capacity etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 15 above but for Window / Split type AC of capacity 1.5 TR capacity etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 15 above but for Window / Split type AC of capacity 2 TR capacity etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 15 above but for Deep freezer of capacity 205 to 310 litres etc complete all as specified and directed by Engineer-in-Charge.
Supply only running/starter capacitor 2.5/3.15/4.0/6.0 mfd, 250 volts , AC, from cooling appliances etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 20 above but of 10.0/15.0 mfd etc complete all as specified and directed by Engineer-in-Charge.
All as per item No.20 above but of 36.0/45.0 mfd 6 pin etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 20 above but of 40.0/60.0 mfd etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 20 above but of 80.0/100.0 mfd etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 20 above but of 50.0/60.0 mfd etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement thermostat suitable for window / Split type AC's, Water coolers, Refrigerators and Deep freezers of any make, capacity and model and testing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement over load protector suitable for window / Split type AC's, Water coolers, Refrigerators and Deep freezers of any make, capacity and model and testing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement box type relay or package assembly from Window type AC's of capacity 1.5 / 2 TR including testing etc complete all as specified and directed by Engineer-in-Charge..
All as per item No. 28 above but for Split type AC's of capacity 1.5 / 2 TR etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 28 above but for Refrigerators of capacity 165 to 310 litres etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 28 above but Water coolers of capacity 40 / 80, 60 / 120 & 60 / 150 litres etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 28 above but for Deep freezers of capacity 205 to 310 Litres etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement 15 mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms /20 m m - 210 g m s . / 25 mm-455 gms/ 40 mm- 690 gms) from water cooler of any capacity, make, location etc including connecting and testing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Push cock, 15 mm dia, brass cromium plated ( SS 304 ) self closing type etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement 15 mm dia Stop valves, brass,chromium plated screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Stainless steel SS 304 water drain out tray for water cooler etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement PVC connection 600 mm long with brass ends terminals suitable for water coolers etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement PVC pipe 32 mm dia for draining out waste water etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Fan blade set for water cooler fan motor etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Door light switch assembly of refrigerators of any model, type, size and capacity to suit the existing including connecting and testing etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement Lamp electric 230 vots, 50 Hz, 15 Watt, pin / threaded type of refrigerators of any model, type, size and capacity to suit the existing including testing etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement Lamp holder of refrigerators of any model, type, size and capacity to suit the existing including testing etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement Timer for refrigerator of existing specifications of any model, type, size and capacity including testing etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement Bimetal for frost free for refrigerator of any model, type, size and capacity including testing etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement Capiliary tube of refrigerators of any model, type, size and capacity to suit the existing including testing etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement Magnetic rubber gasket for refrigerator door of capacity 165 to 310 litres , of any model, type, size and capacity to suit the existing including connecting and testing etc complete all as specified and directed by Engineer-in-Charge. Make : LG , Godrej , Samsung
Supply and fixing in replacement Copper tube 1/4" size for refrigerator, of any model, type, size and capacity to suit the existing including connecting and testing etc complete all as specified and directed by Engineer-in-Charge
All as per item No 47 above but of size 3/8"
All as per item No 47 above but of size 5/8"
Supply and fixing in replacement Evaporative cooling coil for refrigerator of capacity 165 to 310 litres of any model, type, size and capacity including testing etc complete all as specified and directed by Engineer-in-Charge. Make : LG , Godrej , Samsung
Supply and fixing in replacement Condensor coil for refrigerator of capacity 165 to 310 litres of any model, type, size and capacity including testing etc complete all as specified and directed by Engineer-in-Charge Note for srl item Nos 47 & 51 : Gas charging shall be measured and paid separately
Supply only Plug top 3 pin, 230 Volts, 6 Amps including testing etc complete all as specified and directed by Engineer-in-Charge. Make : Anchor , Havells , Legrand
Supply only Plug top 3 pin, 230 Volts, 16 Amps including testing etc complete all as specified and directed by Engineer-in-Charge. Make : Anchor , Havells , Legrands
Supply and fixing in replacement Refrigerator door to refrigerator of any capacity from 165 to 310 litres of any model, type, size including testing etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement Heater of any size to refrigerator of any capacity from 165 to 310 litres of any model, type, size including testing etc complete all as specified and directed by Engineer-in-Charge. Make : Indofos, Denfos or equivalent as approved by GE
Supply and fixing in replacement Air filter PVC type of existing window / split type air conditioners of capacity 1.5 / 2 TR,from any position, of any make including testing etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement Fan blade of existing window / split type air conditioners of capacity 1.5 / 2 TR,from any position, of any make including testing etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement MCB,SP,32 Amps 230/240 Volts,50 Hz for existing window / split type air conditioners including testing etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement Sheet metal enclosure with 3 pin metal clad socket 32 Amps with metal clad plug top including 1 No MCB, SP of capacity 32 Amps for existing window / split type air conditioners ,from any position, of any make including testing etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement PVC insulated cable 3 core 2.5 Sq mm, 1100 Volts grade copper conductor, multistranded including testing etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement PVC insulated cable 3 core copper conductor 1100 Volts grade 1.5 Sq mm for desert coolers including testing etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement Metal clad socket 3 pin 20 Amps, 230 Volts, with plug top 3 pin for existing window / split type air conditioners ,from any position, of any make including testing etc complete all as specified and directed by Engineer-in-Charge
All as per item No. 63 above but of 32 Amps
Supply and fixing in replacement Heatlion insulation pipe for wrapping copper tape duly fixed with polythelene type to suction and discharge lines for existing window / split type air conditioners 1.5 / 2 TR,from any position, of any make including testing etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement Electronic card of existing window / split type air conditioners of capacity 1.5 / 2 TR, from any position, of any make including testing etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement PVC flexible pipe 15 mm dia for desert coolers etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement PVC pipe 15 mm dia with all fittings of existing window / split type air conditioners of capacity 1.5 / 2 TR,from any position, of any make including testing etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement Khus Khus pads of suitable size to dessert cooler of capacity 3000 to 4000 CFM etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement Drum motor 230 Volts, 50 Hz, SP for desert cooler of any capacity,from any position, of any make including testing etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement Water pump, 230 Volts, 50 Hz, SP with discharge head of 1.87 m for desert cooler of any capacity etc complete all as specified and directed by Engineer-in-Charge
Taking down/out old rusted mild steel body of Water coolers, AC's, Refrigerators and Deep freezers and replacing the same with new mild steel sheet, 1.6 mm thick including cutting to shape required, fabricating to size and shape by welding / brazing etc to replace deteroited portion of body to make it functional and spray painting to match with the existing surfaces including making necessary connections etc complete all as specified and directed by Engineer-in-Charge
Taking down/out the fan motor from Desert coolers of any make, size,model and capacity, transporting to work shop, opening up, cleaning, taking out burnt winding etc , and rewinding of motor with superior quality of enamelled copper wire of same guage, re-assembling including over hauling of parts and fixing back the motor at the same or desired position including testing and making necessary connections to make it functional etc complete all as specified and directed by Engineer-in-Charge
All as per item No. 73 above but of Window / Split type AC motors of capacity 1.5 / 2 TR
Taking down/out window / split type AC 1.5 / 2 TR capacity of any make,from existing postion, transporting and refixing at the new location including making necessary connections to make it functional etc complete all as specified and directed by Engineer-in-Charge Note : Gas charging and/or parts if regd shall be measured and paid separetely.
Taking down/out from existing position window type AC's of capacity 1.5 / 2 TR , servicing the same by cleaning, dusting with blower, checking wiring, nuts, bolts, electrical contacts, tightening all loosend parts as required, setting grills and fan blades for proper functioning, oiling, greasing to moving parts and refixing to its original position and testing for smooth functioning etc complete all as specified and directed by Engineer-in-Charge
All as per item No. 76 above but split type AC's of capacity 1.5 / 2 TR
All as per item No. 76 above but refrigrator & deep freezers capacity 165 ltrs to 310 ltrs including washing filters with water
All as per item No. 76 above but water cooler capacity 40 ltrs to 120 ltrs & desert cooler of any capacity upto 5000 cum including washing filters with water
Material & labour for preparing the surfaces by scrapping out the old paint and painting with one coat of painting of existing quality paint to Refrigerator of capacity 165 to 310 litres by spray painting etc complete all as specified and directed by Engineer-in-Charge
All as per item No. 80 above but to Water cooler of capacity 40 / 80, 60 / 120 and 60 / 150 litres
All as per item No. 80 above but to Window type AC of capacity 1.5 / 2 TR
All as per item No. 80 above but to Desert cooler of capacity 3000 / 4000 Cum per hour
Repair of voltage stabilizer for automatic opration single phase naturally air cooled indoor type and desinged for input variation b/t 170 v to 280 v with output voltage stabilized at 230 v with accuracy of + 2.5 % and of capacity 4 / 5 KVA
Repair of voltage stabilizer for automatic opration single phase naturally air cooled indoor type and desinged for input variation b/t 170 v to 280 v with output voltage stabilized at 230 v with accuracy of + 2.5 % and of capacity 0.5 KVA to 2 KVA
Detecting gas leakage of refrigerators, water coolers, deep freezers, window type AC's and split type AC's and rectifying/arresting the leakages,testing for pressure drop complete all as specified and as directed. NOTE: Gas charging shall be measured and paid separately
Material & labour for repairing remote / control kit / electronic card of window / split AC including taking down/out electronic card / control kit including refixing back at site after repair & testing complete all as specified and as directed.
S&F sub main wiring with two single core PVC insulated, unsheathed,FRLS stranded copper conductor cable 3 core with 4 Sqmm PVC insulated, unsheathed,FRLS stranded copper conductor cable as earth wire drawn through in and incl PVC casing and caping ISI marked with all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge. Note: 1. Proper colour coding shall be adopted for wiring(For phase-Red,Yellow,Blue,For Earth-Green for Neutral-Black) Note: Two run of 4 sqmm cable i.e for one run for phase,one run for neutral with one run of 4 sqmm cable for earth and one run of PVC casing & caping Shall be measured as one unit.
Supply and fixing in replacement New indoor unit for split AC 1.5 Ton capacity of suitable for existing out door unit fixing at any position, of any make including testing complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement New indoor unit for split AC 2.0 Ton capacity of suitable for existing out door unit fixing at any position, of any make including testing complete all as specified and directed by Engr-in-charge.
Supply and fix voltage stabilizer for automatic opration single phase naturally air cooled indoor type and desinged for input variation b/t 170 v to 280 v with output voltage stabilized at 230 v with accuracy of + 2.5 % and of capacity 4 / 5 KVA Suitable for Split,Window AC.
Supply and fix voltage stabilizer for automatic opration single phase naturally air cooled indoor type and desinged for input variation b/t 170 v to 280 v with output voltage stabilized at 230 v with accuracy of + 2.5 % and of capacity 0.5 KVA to 2 KVA Suitable for summer cooling Appliances.
Material and labour for Opening of water cooler body by opening nut bolts and stain less steel body and Detecting gas leakage of condensing ,evoparative coils,body leakages and replacing new cooling coil and necessary insulation, rectifying/arresting the leakages,testing for pressure drop and refixing same as it was etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing of mild steel tray for Desert coolers, with new mild steel sheet, 1.6 mm thick including cutting to shape required,fabricating to size and shape by welding / brazing etc to functional and spray painting to match with the existing surfaces including making necessary connections etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement New outdoor unit for split AC 1.5 Ton capacity of suitable for existing indoor unit fixing at any position, of any make including 1.5 Ton Compressor including testing etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement New outdoor unit for split AC 2.0 Ton capacity of suitable for existing indoor unit fixing at any position, of any make including 2.0 Ton Compressor including testing complete all as specified and directed by Engr-in-charge.
An amount of Rs 1,19,610.00 shall be deducted from BOQ on account of schedule of credit
Maruti Abhiyantriki
Ms. S.K. ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .