Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC | ₹1.9 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.9 CrRejected-Finance SF NO 348 5 TIRUPUR TO UDUMALAI ROAD GUDIMANGALAM | TIRUPPUR | TAMIL NADU | 638051 | ₹1.9 Cr | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | MR.S.CHELLADURAI L1 | Karthik L2 |
|---|---|---|---|---|---|
| 1.00Construction of Additional Collector / Project Director Camp office cum Quarters at Tenkasi District under SCPAR 2025-25 | |||||
| 2.00MAIN ESTIMATE | |||||
| 3.00 | Earth work Excavation for Foundation in all soils and Sub Soil to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring strutting and requiring the sides of foundation. | 267.77 | Cum | 263 ₹70,423.51 | 264 ₹70,691.28 |
| 4.00 | Refilling the foundation with Excaveted Earth in layers of not more than 15cm thick well rammed, watered and consolidated as directed by the deptl. officers. Complete complying with standard specifications. | 194.07 | Cum | 45 ₹8,733.15 | 46 ₹8,927.22 |
| 5.00 | Refilling the foundation with Excaveted Earth in layers of not more than 15cm thick well rammed, watered and consolidated as directed by the deptl. officers. Complete complying with standard specifications. | 69.66 | Cum | 45 ₹3,134.70 | 46 ₹3,204.36 |
| 6.00 | Providing Pre-constructional anti- termite treatment and creating a chemical barrier to the building by injecting chemical emulsion of required concentrations raft slab and beam, under Cellular raft slab, around the footings, column pits, trenches, pits, wall trenches, back fill, plinth filling, junction of wall and floor, side walls of foundation, external perimeter of building, surrounding of pipes expansion joints, etc. as per IS specification and as per the instructions of chemical manufacturer and all as directed. The treatment shall be carried out strictly in accordance with the technical specification and conforming to IS 6313 (PART-2) or equivalent BS specification. | 297.46 | Sqm | 120 ₹35,695.20 | 120 ₹35,695.20 |
| 7.001. The chemical to be used as insecticides for the treatment shall be Termitee oil 20% (or) 50% EC and the application shall be dilute one part of chemical 20% or 50% EC with 19 or 49 parts of water to get 1% emulsion and strictly in accordance with the manufacturer's specification.( or)2.The chemical to be used as insecticides for the treatment shall be IMIDACLOPRID 30.5% S C and the application shall be applied at 0.075% active ingredients concentration i.e. 2.1ml formulated product diluted 1 lit of water and strictly in accordance with the manufacturer's specification. | |||||
| 8.00 | Supplying and Filling Gravel : Supplying and filling in foundation and basement with filling sand in layers of not more than 15cm thick well rammed, watered and compacted -1Cum etc. complete complying with standard specifications.. | 227.68 | Cum | 315 ₹71,719.20 | 316 ₹71,946.88 |
| 9.00 | Supplying and filling in foundation, basement, etc with filling M.Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. | 43.67 | Cum | 1,907 ₹83,278.69 | 1,908 ₹83,322.36 |
| 10.00 | Cement Concrete 1:4:8using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick, well rammed, consolidated and curing etc. complete complying with standard specification . | 43.67 | Cum | 5,411 ₹2.4 L | 5,412 ₹2.4 L |
Tender Value
₹2 Cr
EMD Value
₹2 L
Closing Date
27 Feb 2026, 3:00 pmClosed
Project Director
DRDA,Tenkasi
Construction of Additional Collector / Project Director Camp office cum Quarters at Tenkasi Block in Tenkasi District under Scheme Component of Pooled Assigned Revenue 2025-26
2026_RDTN_660373_1
DIPR/1173/TENDER/2026 SCPAR TSI
Open Tender
Civil Works
360 days
DRDA
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹2 L
DRDA,Tenkasi
20 Mar 2026
18 Feb 2026
27 Feb 2026
18 Feb 2026
27 Feb 2026
18 Feb 2026
24 Feb 2026
Construction of Additional Collector / Project Director Camp office cum Quarters at Tenkasi District under SCPAR 2025-25
MAIN ESTIMATE
Earth work Excavation for Foundation in all soils and Sub Soil to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring strutting and requiring the sides of foundation.
Refilling the foundation with Excaveted Earth in layers of not more than 15cm thick well rammed, watered and consolidated as directed by the deptl. officers. Complete complying with standard specifications.
Refilling the foundation with Excaveted Earth in layers of not more than 15cm thick well rammed, watered and consolidated as directed by the deptl. officers. Complete complying with standard specifications.
Providing Pre-constructional anti- termite treatment and creating a chemical barrier to the building by injecting chemical emulsion of required concentrations raft slab and beam, under Cellular raft slab, around the footings, column pits, trenches, pits, wall trenches, back fill, plinth filling, junction of wall and floor, side walls of foundation, external perimeter of building, surrounding of pipes expansion joints, etc. as per IS specification and as per the instructions of chemical manufacturer and all as directed. The treatment shall be carried out strictly in accordance with the technical specification and conforming to IS 6313 (PART-2) or equivalent BS specification.
1. The chemical to be used as insecticides for the treatment shall be Termitee oil 20% (or) 50% EC and the application shall be dilute one part of chemical 20% or 50% EC with 19 or 49 parts of water to get 1% emulsion and strictly in accordance with the manufacturer's specification.( or)2.The chemical to be used as insecticides for the treatment shall be IMIDACLOPRID 30.5% S C and the application shall be applied at 0.075% active ingredients concentration i.e. 2.1ml formulated product diluted 1 lit of water and strictly in accordance with the manufacturer's specification.
Supplying and Filling Gravel : Supplying and filling in foundation and basement with filling sand in layers of not more than 15cm thick well rammed, watered and compacted -1Cum etc. complete complying with standard specifications..
Supplying and filling in foundation, basement, etc with filling M.Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Cement Concrete 1:4:8using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick, well rammed, consolidated and curing etc. complete complying with standard specification .
Supplying and erecting water tight steel shuttering to centering including necessary supports for plane surface in Foundation and Basement for RCC Columns, Footings, Plinth beams, bed blocks, staircase steps etc., using suitable mild steel sheets etc., complete.
Footing ,Plinth beam ,Column upto Basement
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton.
Plain surfaces Roofslab,floorslab,beams,lintels,loft,sillslab,staircase waist,portico slab and other similar works.
Providing and laying in position, Standardised Concrete mix M-25 Grade in accordance with IS 456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement concrete 350kg/Cum and maximum water cement ratio of 0.5, including admixture (plasticiser / super plasticiser) in recommened proportion as per IS :9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0cu.m) 7730kg of 20mm machine crushed stone jelly and with about (3.3cu.m) 5156 kg of 10-12mm machine crushed stone jelly and wiht about (4.79cu.m) 7670 kg of M.Sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fanc clams in the RCC floor/ roof slabs wherever necessary without claiming extra, etc, complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards . (No separate payment will be made by the Department for hte excess usage of materials).
Column footing - Foundation basement
In Ground floor
In First floor
In Head Room
Supplying, fabricating and placing in position M.S. or R.T.S. reinforcement grill for RCC works as per the design given including cost of steel and binding wire etc., complete complying with standard specification. (The contractor will have to make his own arrangements for the supply of M.S. plain rods / RTS rods and binding wire)
Brick work using second class Country bricks of size 8 3/4" x 4 1/4" x 2 3/4" in Cement Mortar 1:5 (one cement and Five sand) including curing, neat finishing, etc, complete complying with standard specification.
Foundation and Basement
Ground Floor
First Floor
Terrace and Head Room
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone M.Sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone M.Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
Brick partition wall of 11cm thick using country bricks of size 8 3/4 x 4 1/4 x 2 3/4" in cement mortar 1:3 (One cement and three sand) using hoop iron reinforcement if found necessary including finishing and curing etc., complete.
Ground floor (11cm thick)
In First floor (11cm thick)
Paving the floor with best quality Vertified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three crushed stone M.Sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three M.Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone M.Sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two crushed stone M.Sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
Supply & Fixing of 35mm thk.single leaf high density interior grade marine plywood shutters pasted both sides 1.5mm thk.laminate approved design with 35x12mm T.W.lipping on all edges with necessary adhesives and CP screws complying with standard specification.The cost is inclusive of 1 no cylindrical Lock,handel,tower bolt ,approved equivalent make SS ball bearing hinges of quivalent make of aproved make,2 no floor mounted SS door stoper ect.complete as per drawing. Make: Kutty,Sharon, Trojan. Accesseorice Make: Dorma, Godrej.1.5mm thk Laminate Basic Cost:810/Sqm .
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mmetc.,complete M-0675
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. M-0674
Supplying and fabricating and fixing MS grill works to windows and grill gate using necessary MS flst for inner and outer members should be fixed to window frames
Supplying and fixing of 2/3 Grill and 1/3 paneled door including cost of all materials and labour fixing charges etc.,complete.
Plastering with Cement Mortar 1:5 (One cement and Five P.Sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three P.Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [ The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coat of putty, scrapping the putty area to level the surface smooth, etc., complete]. The Putty shoule be got approved by the Executive Engineer before use on work.
Plastering with Cement Mortar 1:4 (One Cement and Three P.Sand) 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification. (The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work).
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Supplying, fabrication and fixing of 30mm thick both side pre laminated WPC door shutter with frame of required size 0.75m x 2.00m using 75mm x 50mm size WPC frame as allround frame with necessary brass furniture fittings such as 125mm x 25mm brass hinges-3Nos , 200mm x 12mm brass tower bolt - 1No, 150mm x 12mm brass tower bolt - 2Nos,150mm brass handle - 2Nos, T.W lippings around the shutter etc., including cost and conveyance of all materials complying with standard specification.
Manufacturing,supplying and fixing of stainless steel hand rails for staircase using 50mm dia 304L grade stainless steel pipe of 1.6mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia stainless steel pipe post of 1mm thick as vertical at 900mm centre with 2 Nos of 25mm dia intermediate horizontal stainless steel pipe of 1.6mm thick in between.The vertical pipe has to be welded to the 100 x 100 x 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing,conveyance, electrical charges,ect.complete M-0651
Supply and fixing of polished granite slab ,18 mm thick (average), for flooring including fixing in position cutting , chipping the wall, masonry touch up works etc., complete in all respects for all floors as directed by the departmental officers
Septic tank
Earthwork for foundations and depositing on bank with initial lead of 10 Mt. and initial lift of 2 Mt. in sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soil including excavated earth.
Supplying and filling in foundation and basement with m sand in layers of not more than 10cm thick well watered, rammed and consolidated etc., complete as per standard specification.
Laying the Plain Cement concrete 1:4:8(One cement four sand and eight broken Machine crushed stone jelly) using HBG Machine creased Machine crushed stone jelly of size 40mm gauge for founding and basement including de- watering if found necessary and laid in layers of not more than 15cms thick etc., complete complying with standard specification and as directed by the departmental officers. The rates inclusive of Centering , shuttering, strutting, propping,removal of form work if it is required and all leads ,lifts and curing etc..
Bio Septic tank Material : HDPE No of Flushes :75 Capacity : 1800 Ltrs Size: 2190 X 115 X 150 M
Plumbing work
Supply and fixing in position white European Water Closet In Jaquar - Rimless Wall Hung WC With UF Soft Close Seat Cover, Hinges, Accessories Set, Size: 390x570x365 mm and Single Piece Concealed Cistern Body (Front or Top Actuation) with Floor Mounting Frame, Installation Kit and “S-Type” Drain Pipe Connection Set for Wall Hung WC (without Flush Control Plate) or equivalent. complete complying with standard specification and as directed by the Departmental officers (The EWC should be got approved by the Executive Engineer before use on works.)
Supplying and fixing of Jaquar - CP Two Way Bib Cock Kubix Prime with ABS Jaquar Health Faucet ALD ,wall hook & one metre long flexible tube including cutting and making good the walls wherever required or equivalent. as directed by the Department officers. The quality and make of health faucet should be got approved by Concern department Executive Engineer before use on work.
Supplying - one metre long flexible tube for Health Faucet including cutting and making good the walls wherever required or equivalent. as directed by the Department officers. The quality and make of health faucet should be got approved by Concern department Executive Engineer before use on work
Supplying and fixing Jaquar Square - Wash Basin Over Counter Basin, 410 X 410 X 155mm with all accessories or equivalent as directed by the Department officers. (The Wash basin should be got approved by the Executive Engineer before use on works.)
Supplying and fixing Jaquar Florentine Series Faucet/Tap With Wall Flange Long body Bibcock Faucet (Wall Mount Installation Type) including cutting and making good the walls wherever required or equivalent, complete complying with standard specification and as directed by the Engineer Incharge before use on work.
Supplying and fixing Jaquar Brass Angle valve Florentine with wall flange including cutting and making good the walls wherever required or equivalent, complete complying with standard specification and as directed by the Engineer Incharge before use on work.
Towel Rail :Supplying and fixing Brass Chromium Plated Towel Rail 60cm long and 20mm dia with brackets of same materials including cost of teak wood plug & CP screws etc., complying with standard specification and as directed by the Department Executive Engineer before use on work.
Mirror :Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks).
Supplying,installing,testing and commissioning of Jaquar make CONCEALED STOP COCK 15 mm dia for including neccesary accessories or equivalent ,complete,works include making require size curout in wall,and fixing the control box property,redoing the same etc,complete the quality and make of concealed stop cock should be got approved by concern department Executive Engineer before use on work.
Supplying & fixing of Coat hook with brackets including fixing over Wall tile dado / door shutter using suitable size non-corrosive screw nails etc. complete.(Make: Parryware or equivalent)
Supplying and fixing Jaquar Stainless Steel Silver Jaquar ORP-CHR-10021PM High Neck Basin Tap with all accessories or equivalent as directed by the Department officers. The quality and make of diverter should be got approved by Concern department Executive Engineer before use on work.
Supplying and fixing of Brass Jaquar Diverter Set or equivalent. as directed by the Department officers. The quality and make of diverter should be got approved by Concern department Executive Engineer before use on work.
Supply and fixing Stainless Steel Jaquar Bathtub Spout or equivalent. as directed by the Department officers. The quality and make of diverter should be got approved by Concern department Executive Engineer before use on work.
Supply and fixing Stainless Steel Jaquar Overhead Square Shape Shower or equivalent. as directed by the Department officers. The quality and make of diverter should be got approved by Concern department Executive Engineer before use on work.
Supply and fixing Brass Silver Jaquar Florentine FLR-CHR-5347N Sink Tap or equivalent. as directed by the Department officers. The quality and make of Sink tap should be got approved by Concern department Executive Engineer before use on work.
Supply and fixing Jaquar Washing Machine tap or equivalent. as directed by the Department officers. The quality and make of Washing Machine tap should be got approved by Concern department Engineer before use on work.
Supplying and fixing Brass Chromium Plated Soap Tray of size 150mm x 100mm using rawl plug & brass screws for fixing etc., complete complying with standard specification and as directed by the Engineer Incharge before use on work.
PART - B SOIL, WASTE AND VENT PIPE LINES
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages,etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level.
40mm dia. 6kg class PVC pipes.
50mm dia. 6kg class PVC pipes.
75mm dia. 6kg class pipes.
110mm dia. 6kg class pipes.
Supplying and fixing in position PVC nahini /Floor Trap with PVC Grating type of size 100x75/75x50 mm with best quality gratings of approved brand fixed over a bed of brick jelly lime concrete 1:2:5(One lime two sand and five aggregate) brick jelly 40mm and finishing with CM 1:3(One cement and three sand)wherever found necessary and making good to the original condition and giving connections to the PVC pipes etc., complete complying with standard specification and as directed by the Departmental Officer.
Supply and fixing in position best quality PVC IS 4985 - CLASS-II - 4 Kg/Sqcm -Rain water pipes of various size having ISI mark and providing leak proof joints with such as Bend, Tee Junction, door etc.,of approved qualityincluding fixing to the wall with special PVC /MS clamps, etc., and making connection to all sanitary fittings, wherever necessary and making chipping good to the original condition, complying with standard specification etc., complete.
110mm dia. 4kg class pipes.
Supplying and fixing in position of the following dia PVC rain water gratings for rain water pipes ,of approved quality and variety of various size confirming to ISS and including necessary cutting and fixing and giving connection to PVC pipes etc., complete complying with standard specification and as directed by the Departmental Officer
100mm x 75mm
Supplying and fixing in position of the following dia PVC specials such as PVC vent Cowl etc.,of approved quality and variety of various size confirming to ISS amend providing leak proof joint etc., including necessary cutting and fixing and giving connection to PVC pipes etc., complete complying with standard specification and as directed by the Departmental Officer
110mm dia
75mm dia
PART-C - EXTERNAL DRAINAGE
Supply and fixing in position best quality PVC IS 4985 - CLASS- III - 6 Kg/Sqcm -Soil/ waste pipes of various size with approved quality and variety of various size confirming having ISI mark and providing leak proof joints including erection of below ground with excavation and refilling etc., and making connection to Manholes / Gully trap, wherever necessary and making chipping good portion to the original condition, complying with standard specification etc.,complete.
110mm dia. 6kg class PVC pipes.
75mm dia. 6kg class III-pipes.
Supply, laying and erction of glazed stone ware gully trap (100 x 75 mm) with 100 mm dia, outlet including embedding trap in cement concrete 1:3:6 and constructing chamber of size 300 x 300 mm inside clear in brick masonry 230 mm thick, plaster with water proof cement mortar (1:3) 15 mm thick on both internal and external surfaces inside finished with floating coat of neat cement. The work including excavation to required depth of gully trap and refilling and making good in the surface with Providing and fixing SFRC frame and cover 400 x 400 mm (clear opening) complete complying with std. specification.
Supplying and Erection and construction of sewer chambers of required internal dimensions 450x450 upto 0.6 mtr.depth with 230mm brick masonry in C.M.1:5 thk of masonry over bed of 1:2:4 R.C.C. 200 mm thk bove 100 mm thk P.C.C.1;3:6 Cement concrete foundations over sand bed of 100mm thk channelling in 1;2:4 cement concrete, plastering in 1:3 cement mortar for internal and external surface finished with floating coat of neat cement, the work including excavation for required depth of gully trap and refilling and making good in the surface with SFRC cover and frame 450x450mm (clear opening)complete complying with standard specifications etc.,
Construction of rain water recharge well of 1200mm dia and depth upto 1500mm, in addition 110 dia special blue slotted pipe for bore well.pipe should be laid from bottom of ring well centre to below 1500mm as shown in the drawings, including all types of excavation,occur for pipe, filling of rain water harvesting materials with construction of R.C.C. ring and top 100mm RCC SLAB WITH 450X450mm perforated SFRC manhole and 230mm brick wall in 2'height with below 300mm lengthx100mm thk P.C.C. as per the structural filling the filter media as per drawing.
D. WATER SUPPLY SYSTEM
Internal Concealed Works
Providing, supplying & laying of Unplastarized Poly Vinyl Chloride (UPVC-SDR-11 Pipes conforming to IS 15778 having thermal stability cold water with brass and UPVC fittings like Elbow, Brass Tee, Brass Elbow, Offsets, Tee with clamps @1.00 meters spacing, with jointing of pipes with one step UPVC solvent cement with including cutting of chase including testing of the joints complete and making good the walls etc. Rate is inclusive of all material labour, transportation, tools & tackles taxes, levies VAT etc all complete as per as per specifications, Concealed work including chase cutting)complete complying with standard specification and as directed by the Departmental Officer.
20 mm nominal (OD) pipes
25 mm nominal (OD) pipes
32 mm nominal (OD) pipes
E.EXPOSED PLUMBING WORKS
Providing, supplying & laying of Chlorinated Poly Vinyl Chloride (UPVC-SDR-13.5) Pipes conforming to IS 15778 having thermal stability cold water with brass and UPVC fittings like Elbow, Brass Tee, Brass Elbow, Offsets, Tee with clamps @1.00 meters spacing, with jointing of pipes with one step UPVC solvent cement with including cutting of chase including testing of the joints complete and making good the walls etc. Rate is inclusive of all material labour, transportation, tools & tackles taxes, levies VAT etc all complete as per as per specifications, Exposed work including chase cutting, bracket fixing)complete complying with standard specification and as directed by the Departmental Officer.
32mm nominal(OD) pipes (AGL)
40mm nominal(OD) pipes (AGL)
F. EXTERNAL PLUMBING WORKS
Providing, supplying & laying of Chlorinated Poly Vinyl Chloride (UPVC) Pipes conforming to IS 15778 having thermal stability cold Metro water with brass and UPVC fittings like Elbow, Brass Tee, Brass Elbow, Offsets, Tee with clamps @1.00 meters spacing, with jointing of pipes with one step UPVC solvent cement with including cutting of chase including testing of the joints complete and making good the walls etc.Rate is inclusive of all material labour,transportation, tools & tackles taxes, levies VAT etc all complete as per as per specifications,Concealed work including chase cutting) complete complying with standard specification and as directed by the Departmental Officer.
32mm UPVC pipes
40mm UPVC pipes
Providing, supplying & laying of Gunmetal type NRV - pressure rating less tahn 16 Kg/Sqcm and IS778 with 2 Nos of MTA with jointing material like shellac, thread including testing of the joints complete and making good the walls etc. Rate is inclusive of all material labour, transportation, tools & tackles all complete as per as per specifications, complete complying with standard specification and as directed by the Departmental Officer.
Supplying and erection of horizontal shaft centrifugal mono block power pump set of single phase 2.00 H.P of best approved quality and make with ISI mark on suitable pedastal with foundation bolt and nut including labour supplying and fixing of starter and main switch suitable for 2.00 H.P pumpset on suitable angle iron frame work with necessary labour including panel board, supply and run off 4 of 10 Sq,mm, in P V C pipe with 14 SWG TC wire including fixing of suction pipe and foot valve up to a maximum depth of 7m and delivery pipes upto the exterior wall of pump room etc., complete and operating the pumps on trial run for 3 days. (The make and quality of pump set to be got approved by the Executive Engineer before use on works.) (TWAD- Pa no:103 Sl.no:45)200mx60m
Supplying and erection of Pressure Boosting Pump, CPBS-84424V, 1.5 HP, Single Phase, 220 Volts, Size 25mm X 25mm
Electrification Work
Wiring with 2x1.5sq.mm.PVC insulated unsheathed FRL SSC copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with PVC accessories with TWswitch box wth5AFT switch in flush with wall covered withh ylem sheet of 3mm thick with painting of suitable colour for open PVC light point / fan point (for electronic regulator) ( SD 21 )
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling and switch drop portion PVC rigid pipe concealed in wall with PVC accessories with Module GI switch box in flush wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire with painting of Suitable colour for Open PVC Light point / fan point (for electronic regulator) ( 6 points / Coil) Higher End (SD 300 )
Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Lower End ( 8 points / Coil) Higher End (SD 310)
Supply and fixing of fancy glass shade and 15 W LED Bulb( SD 80)
Supplyandfixingofsingleboxtype4'36WfluorescentfittingcompletewithelectronicballastwithTWroundblocksonwall or ceiling with flu tube with PVC unsheathed FRLS Copper leads from terminals to the fitting.(SD 87)
Supplyandfixingof4FeetLED20WFittingwithLED20Wtube(HigherEnd)completewithTWroundblockson wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting.(SD443)
Supply and fixing of ceiling fixture 250/300mm complete with gallery etc clear glass Opac/Crystalsuitablefor7W/9W LED bulb with bulb (SD86)
Supply and fixing of WT bulk head fitting with guard suitable for 15 W LED Bulb (SD83)
SupplyandfixingofAC/DC76mmbuzzer/callbellsuitablefor230volts50c/ssinglephaseACsupplyonsuitableTWboard with push switch.(SD105)
supply and fixing of 1200mm (48") sweep AC ceiling fan 5 star rated complete ( Lower end) with 2 module 100W fan step regulator (Lower end) with 600mm down rod with fan clamp with side plates and cross arm of size 450mm (18") ( SD 486)
supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Lower end) with 600mm down rod with fan clamp with side plates and cross arm of size 450mm (18") ( SD 488)
Supply and fixing of 375mm (15") sweep (light duty) AC exhaust fan complete without provision of holes in the wall. (SD 117)
Supply and fixing of 300 mm sweep Wall Mounted Fan Circulator complete and including fan clamp with Necessary required Job etc…(M-1354)
Supply and fixing of 1 no.6A two module 3 pin socket , 1 no. 6A one module switch on suitable module surface mounting Box ( GI ) with module cover plate (plastic) on wall with connections. Lower End. (SD 377)
Supply and fixing of 1 no.6/16 A two module socket , 1 no. 16A one module switch on suitable module surface mounting Box ( GI ) with module cover plate (plastic) on wall with connections. Lower End. (SD 401)
Supply and fixing of 3 nos.6/16A two module socket , 3 nos. 16A one module switch on suitable module surface mounting Box ( GI ) with module cover plate (plastic) on wall with connections. Lower End. (SD 413)
Supply and fixing of 20Amps DP Plug and Socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For AC Plug) [Legrand (MDS) / Hager (L&T) make](SD 144)
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40A DP MCB Isolator as incoming and 6 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End (SD 518)
Supply and fixing of 6 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 No 63A 4P MCB as incoming and 18 Nos 6A to 32A SP MCB as outgoing in flush with wall with Earth connection only. Lower End (SD 557)
Supply and run of 2 of 1.5sq.mm.PVC insulated Scunsheathed FRL Scopper conductor of 1100V grade in rigid pipe concealed in walland ceiling with continuous earth wire connection of 15sq.mm copper wire and making good of the concealed portion with suitable colour (SD 55)
Supply and Run of 2 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe on wall and ceiling with continuous earth wire connection of 10 sq mm copper wire with painting of suitable colour. (SD 337)
Supply and Run of 4 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe on wall and ceiling with continuous earth wire connection of 2.5 sq mm copper wire with painting of suitable colour..(SD 341)
Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour..(SD 347)
Supply and Run of 4 of 10 sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in 25mm dia GI pipe (class B ) suitably bent at both ends with necessary angle iron upright and end support for service connection mains .(SD 370)
Supply and Run of 1 of No.8 SWG copper wire for earth connection (SD 371)
Same as SD 198, except 3-1/2 x 150 sq.mm. PVC LTUG armoured cable (SD 211)
SupplyandfixngofTNEBmeterboardsuitablefor3phase100Aserviceconnectionmadeupofsuitableangleironframeworkofsize2feetx1-1/2feetusingangleironofsize1-1/2"x1-1/2"x1/4"rigidlyfixedonwallcoveredwithhylemsheetofsize2feetx1-1/2feetof12mmthicknesswithnecessaryboltsandnutssupportsandsupplyandfixingof3Nos.100Afuseunits(500V),1No.neutrallink,copperearthflatofsize1"x1/4"withinterconnectionofEBmetertofuse units by 16 Sq.mm PVC insulated copper wire with earth connection complete (SD 133)
Supply and fixing of 63A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with Earth connection only.. (SD 656)
EarthingaspertheISIspecificationwithanearthelectrodeof2.10metreClass'B'GIpipeofdianotlessthan40mmwithcopperearthplateofsize125mx50mmx6mmwithnecessaryfunnelingarrangementswithnecessarymasonrywork and with 38mm RCC cover slab for the brick masonry (SD 221)
Supply and Installtion of 2 kVA 1 Phase Input 1 Phase output true online UPS with in biult galvanic isolation (Tarnsfomer) , VRLA SMF batteries for 2 Hrs backup , Interlinks , UPS to battery cable , stand top covered .(M-2106)
Earthwork for foundations and depositing on bank with initial lead of 10 Mt. and initial lift of 2 Mt. in sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soil including excavated earth.
Supplying and filling in foundation and basement with m sand in layers of not more than 10cm thick well watered, rammed and consolidated etc., complete as per standard specification.
Laying the Plain Cement concrete 1:4:8(One cement four sand and eight broken Machine crushed stone jelly) using HBG Machine creased Machine crushed stone jelly of size 40mm gauge for founding and basement including de- watering if found necessary and laid in layers of not more than 15cms thick etc., complete complying with standard specification and as directed by the departmental officers. The rates inclusive of Centering , shuttering, strutting, propping,removal of form work if it is required and all leads ,lifts and curing etc..
Supplying and Erecting centering for sides and soffits including necessary supports and strutting up to 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification. (Payment for centering shall be given after the concrete is laid)
Providing and laying in position machine batched,machine mixed and machine vibrated design mix cement concrete of Sqm5 grade for reinforced cement cement ratio with plasticiser using 20mm and down concrete structural elements under controlled water graded machine briken grnite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification and as directed by the depart- mental officers comple.-1Cum
Supply, fabrication and placing of reinforcement steel of high yield strength ribbed bars of various diameters and grade conforming to IS 1786 for reinforced concrete work. The work includes recoiling, straightening, cutting, bending, fabricating, and placing in position, at all levels including lead and lift, according to drawings, specifications etc. complete and supply & use of 18G black annealed binding wire double fold to tie the bars in position and providing precast cement/ PVC cover blocks for main reinforcement to ensure specified cover and complete., including all labor charges etc as directed by departmental officers.
Plastering with Cement Mortar 1:4 (One Cement and Three M.Sand) 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
Supplying, laying and fixing in position ceramic tiles of approved size , quality and colour set k in CM 1:3 - 20 mm thk. Including cutting the tiles to the required size with special cutter where ever necessary and pointing the joints with coloured cement using 0.40 Kg / Sqm including finishing the flooring and pointing the joints flesh with tile surface etc.complete.Basic cost-Rs.464/sq.m
Supplying and fixing in position C.I.Manhole covers (heavy duty) of various sizes of best approved quality and as per standard specificationsetc.,complete.0.6X0.6M Size etc., complete.
PVC mould CI steps for sump M-0653
Elevation work
Granite Stone Cladding in wall of best quality and free from any defect, approved quality colour set in CM 1:2 complying with standard specification and as directed by the Department Executive Engineer before use on work.
CNC Jali -MS jali laser cutting service specializes in the precise cutting of mild steel (MS) jali or perforated sheets using advanced laser technology. complying with standard specification and as directed by the Department Executive Engineer before use on work.
Earthwork for foundations and depositing on bank with initial lead of 10 Mt. and initial lift of 2 Mt. in sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soil including excavated earth.
Laying the Plain Cement concrete 1:4:8(One cement four sand and eight broken Machine crushed stone jelly) using HBG Machine creased Machine crushed stone jelly of size 40mm gauge for founding and basement including de- watering if found necessary and laid in layers of not more than 15cms thick etc., complete complying with standard specification and as directed by the departmental officers. The rates inclusive of Centering , shuttering, strutting, propping,removal of form work if it is required and all leads ,lifts and curing etc..
Supplying and Erecting centering for sides and soffits including necessary supports and strutting up to 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification. (Payment for centering shall be given after the concrete is laid)
Plain Cement Concrete 1:2:4 (one cement, two M.Sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.
Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method)
Providing and laying spreading and compacting graded stone aggregate to Wet Mix Macadam(WMM) specification including premixing the material with water at OMC in machanical mix plant carriage of mixed material by tipper to site laying in uniform layers 250mm thick with pavers in SubBase/Base course on well prepared surface and compacting with vibratory roller to achieve the desired density including cost of material,labour charges, rentals for machinery, fuel and all other incidental charges etc., complete.
Parking Tile- Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone M.Sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) Using anti-skid tiles (Observed Data)
Providing and Laying of Interlocking Concrete (Surface Textured) Block Pavements having thickness 80mm and compacted over a thin bedding M.Sand layer of 30 mm thickness and joints shall be filled by fine M.Sand of specified grading as per table 1500.6 of Specification of Rural roads-2014 and Technical specification clause 1504.
Framed 1000mm height Most tempered glass comes in ½” thicknesses with framed system. complying with standard specification and as directed by the Department Executive Engineer before use on work
Car Shed
Earthwork excavation for foundation (for narrow excavation) to full depth as per designed in all soils and sub soils except soft disintegrated rock not requiring blasting and hard rock requiring blasting and bailing water wherever necessary. Refilling the sides of foundation with excavated earth other than sand in layers of well rammed and compacted and depositing the surplus earth in places shown by the departmental officers with an initial lead of 10m and initial lift of 2m and clearing and leveling the site etc. complete complying with standard specification.
Providing Pre-constructional anti- termite treatment and creating a chemical barrier to the building by injecting chemical emulsion of required concentrations raft slab and beam, under Cellular raft slab, around the footings, column pits, trenches, pits, wall trenches, back fill, plinth filling, junction of wall and floor, side walls of foundation, external perimeter of building, surrounding of pipes expansion joints, etc. as per IS specification and as per the instructions of chemical manufacturer and all as directed. The treatment shall be carried out strictly in accordance with the technical specification and conforming to IS 6313 (PART-2) or equivalent BS specification.
Supplying and filling in foundations and basement with filling M- sand in layers not exceeding 15 cm. thick, well watered ,rammed and consolidated etc. complete complying with standard specifications.
Plain Cement Concrete 1 : 4 :8 ( one part of cement, four parts of sand and eight parts of hard broken stone ) using 40 mm gauge hand broken hard broken granite stone jelly complying with standard specifications in foundations and basement.
Supplying and Filling Gravel:Supplying and filling in 'foundation and basement with filling sand in layers of not more than 15cm.thick well rammed watered and compacted -1Cum etc.,complete complying with standard specification.
Supplying and erecting Centering and Shuttering for soffits including necessary supports and strutting up to 3 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification.(Payment for centering shall be given after the concrete is laid).
Footing, Plinth Beam, etc.
Column Below basement Level
Design Mix Concrete
Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000, using 20mm and down grade hard broken granite stone jelly for all RCC Items of works with minimum cement content of 350kg/Cum and maximum water cement ratio of 0.50, including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS:9130 to accelerate, rated setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m) 7730kg. of 20mm machine crushed stone jelly and with about (3.3cum) 5156 kg. of 10-12mm machine crused stone jelly and with about (4.79cum) 7670 kg of sand,
but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with Mechanical vibrators, finishing, curing, etc.,and providing fixtures like fan clamps in the RCC Floor / roof slabs wherever necessary without claiming extra, etc., Complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No Separate payment will be made by the Department for the excess usage of materials).
Foundation & Basement
Steel - Fe 500 D
Supply, fabrication and placing of reinforcement steel of high yield strength ribbed bars of various diameters and grade conforming to IS 1786 for reinforced concrete work. The work includes recoiling, straightening, cutting, bending, fabricating, and placing in position, at all levels including lead and lift, according to drawings, specifications etc. complete and supply & use of 18G black annealed binding wire double fold to tie the bars in position and providing precast cement/ PVC cover blocks for main reinforcement to ensure specified cover and complete., including all labor charges etc as directed by departmental officers.
Brick work in following Cement Mortar 1:5 using best quality Country bricks of size 8"3/4 x 41/4" X2 3/4" for foundation and basement including curing etc., complete complying with standard specification. Including scaffolding curing cost of reinforcement etc. all complete as per specifications and drawings as directed by the Engineer in-charge.
Foundation basement
Providing & applying 12 mm thick cement plaster in CM 1:5 (1 part of cement: 5 parts of sand) to walls internally in single coat at all levels to correct line and level including chicken wire mesh at all joints of brick and concrete surfaces with minimum overlap of 150 mm in all directions, scaffolding, rounding off or chambering of corners, offsets, fin/ bands, projections, etc. and cleaning of surface, raking out joints, roughening of surface, chiseling the undulated surface wherever necessary and curing, etc., all materials and labor complete in all respects including all lead, lift and descent and as directed.
Providing & applying 12 mm thick cement plaster in CM 1:5 (1 part of cement: 5 parts of sand) to walls externally in single coat at all levels to correct line and level including scaffolding, rounding off or chambering of corners, offsets, fin/ bands, projections, etc. and cleaning of surface, raking out joints, roughening of surface, chiseling the undulated surface wherever necessary and curing, etc., all materials and labor complete in all respects including all lead, lift and descent and as directed.
Supplying and painting the walls with one coat of wall primer and two coats of Exterior emulsion (apex or equivalent) as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications (The colour and shade of the cement paint shall be got approved by the Executive Engineer before use of work).
CAR SHED TRUSS MEMBER
Design, Fabrication and Erection of Sag & Bracing Rods, Base Plate, Bolt, Gusset plate - as per above mentioned specifications, dimensions and design standards.
Design, Fabrication and Erection of Stiffner - as per above mentioned specifications, dimensions and design standards.
Design, Fabrication and Erection of Steel Structures (M1,Sqm)- as per above mentioned specifications, dimensions and design standards.Refer: (Structural Drawing Sheet)
Design, Fabrication and Erection of Steel Structures (M4)- as per above mentioned specifications, dimensions and design standards.Refer: (Structural Drawing Sheet)
Design, Fabrication and Erection of Steel Structures (M4)- as per above mentioned specifications, dimensions and design standards.Refer: (Structural Drawing Sheet)
Design, Fabrication and Erection of Steel Structures (M4)- as per above mentioned specifications, dimensions and design standards.For Side Cladding Refer: (Structural Drawing Sheet)
Supplying and fixing colour galvalume sheet roof of 0.47mm thickand steel tubular box section of 100x50x3mm of 1meter interval including priming coat fixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers.
Furniture and False Ceiling
Office Room Table : The Table Top & leg made of 25 mm thick particle postformed with decorative laminate and duly edge banded with PVC edge beeding , and keyboard tray. Table size of 1800 mm x 900 mm x 750 mm ht & Executive Return table of size 1200mm x 525mmx 725mm(H) and having Fixed Pedestal of size 450mm (W) x 450mm (D) x 640mm (H) having two draw and one filing draw made of 18mm thick pre laminated particle board duly edge banded with 2mm thick PVC beeding. The drawer having a lock and key arrangements The Table having a joing discussion table of size 1100mm x 1050mm x 750mm (H) made out 25 mm MDF with deco paint finish allround edges are ducknose finish and having a supporting leg made out of 75mm diaMS powder coated with leveller adjustment
PC Office Table : The Main Table of Size : 1600mm (L) x 600mm (D) x 750mm (H) and having side table cum storage unit of size 900mm x 450mm x 750mm (H) The side table having a two drawer on top bottom with swing type shutters with lock and key arrangements. The Table top made out of 25mm thick particle board and 0.6mm decorative laminate finish with postformed finish.
Executive Chair Model Jupiter High Back . The chair are Glass filled nylon base with twin wheel nylon castors and 120mm Gaslight for seat height adjustment. Synchronised multi‐function mechaism.Glass filled nylon backrest with Korean mesh. Seat upholstered with PU module foam and approved fabric. Tested as per ANSI/BIFMA standards. 4D swivel and height adjustable armrest with PU pad.
Dynamic Medium Back Chair : Glass filled nylon base ,Gaslift,twin wheel nylon castors , T Type adjustable PU armrest .back :ABS with mesh upholstery Synchro tilt mechanism , inbuilt lumbar support,seat PU moulded cushion (Council Hall )
Three Seater Visitor Chair : made out 50mm dia MS powder coated frame work and seat & back portion of chair made out of 18 SWG Perforated sheet fixed 40mm modulded cushion and artificial leather/ fabric finish etc
Visitor Chair Non revolving MS powder coated leg . The chair are seat foam chusion with approved fabric and ABS back rest with koren mesh upholstery inbuilt lumbar support,seat
Providing Cup-board Shutter with frame using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work.
Storage Size : 2250mm (L) x 600mm (D) x 2100mm (H)
Low Storage Size : 4500mm (L) x 600mm (D) x 900mm (H)
Supplying, fabricating, erecting and fixing Hilux (or) Equivalent Board False Ceiling upto a ceiling height of 4.5m from floor level In Hall Area : 13065mm (L) X 4800 mm (B)
Compound Wall Elevation Work
Earth work excavation in all clauses of soils with initial lead and lift except hard rock requiring blasting etc., complete for foundation as per SS 20B
Cement concrete 1:4:8 mix using 40mm ISS HBG metal including all cost and conveyance and all labour charges etc., complete
Centering charges for all concrete works including all cost and conveyance of all materials and all labour charges etc complete
Column Upto GL
Superstructure wall
Brick work in CM 1:5 mix using third class country bricks of size 8 3/4 x 4 1/4 x 2 3/4 including all cost and conveyance of materials and labour charges etc., complete.
Supplying and fabrication of steel including cost and conveyance of bending to shape and tying in position and forming grills for all R.C.C works including cost and conveyance of all materials to site and all labour charges for mixing, laying, and curing
Reinforced cement concrete 1:1.5:3 mix using 20mm ISS metal including cost and conveyance of all materials to site and all labour charges for mixing, laying, and curing etc complete for 10 cum.
Plastering with cement mortar 1:5 mix to 12mm thick including cost and conveyance of all materials to site and all labour charges etc complete for 10 Sqm
Exterior Emulsion painting two coats with best approved quality and colour paint over one coat of Base coat including cost and convyance of all materials to work site and labour charges etc., complete.
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.30 MB
TechnicalbidTsi.pdf
Tender Documents • 0.49 MB
pricebidsTsi.pdf
Additional Documents • 0.60 MB
BOQ_792329.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid