Loading…
Loading…
Tender Value
₹75.5 Cr
EMD Value
₹1.5 Cr
Closing Date
15 Apr 2026, 5:00 pmClosed
RIZWAN AHMAD
CE
Appointment of Agency for providing New Service Connection with Infra Extension upto 150 KW (NSC Phase-III) in Electric Supply Circle Bhagalpur under Jurisdiction of SBPDCL in Bihar under ?New service Connection Phase III Scheme?.
127353
16/PR/SBPDCL/2026
Open Tender
ELECTRICAL
Patna
• Name of the Bidder/ Manufacturer
• Address & contact no of the Bidder/ Manufacturer
• Electrical contractor's License Class A ( Give registration N o., Validity and details)
• Cost of Tender( Required amount - Rs. 100000+18%GST Give details of amount and online receipt no.
• Attachment 1 : Bid Security (Earnest Money Amount )- shall be valid for ninety(90) days beyond the original validity perio d of the bid ( Give details of amount, validity and BG Detail)
ELECTRICAL
ITEM RATE
L1
1
47 documents required · 47 mandatory
₹1.2 L
Processing Fee: 5900
₹1.5 Cr
Conference hall, Third floor, Vidyut Bhawan - 3 Bailey Road , Patna - 800021
23 Mar 2026
23 Mar 2026
17 Apr 2026
24 Mar 2026
15 Apr 2026
24 Mar 2026
30 Mar 2026
NIT No: 16 to 26/PR/SBPDCL/2026
TECHNICAL & COMMERCIAL PART (Part-I)
Name of Utility :- SOUTH BIHAR POWER DISTRIBUTION COMPANY LIMITED
Name of Department :- Project-II
NIT No :- NIT No: 16 to 26/PR/SBPDCL/2026
Name of Scheme :- Appointment of Agency for providing New Service Connection with Infra Extension upto 150 KW (NSC Phase-III) in 11 Electric Supply Circles under Jurisdiction of SBPDCL in Bihar under “New service Connection Phase III Scheme”
Estimated Cost (in Rs Cr.) :- As per Notice Inviting Tender
Bid Security (Earnest Money Deposit) (in Rs Cr.) :- As per Notice Inviting Tender
Time of Completion (in months) :- 24 Months from date of issue of Notification of Award (NOA).
Cost of BOQ (in Rs.) :- Rs 1,00,000+18% GST
Processing fee for BSEDC (in Rs.) :- As per Actual
Sl No. Details To be Filled in color cells by Contractor [Submit- YES/NO from Sl. No. 5 onwards] Page No [Page numbered document details] Remarks (If any)
1 Name of the Bidder/ Manufacturer :- From To
2 Address & contact no of the Bidder/ Manufacturer :-
3 Electrical contractor's License Class A ( Give registration No., Validity and details) ( Document submitted Yes/ No with page no.) :-
4 Cost of Tender( Required amount - Rs. 100000+18%GST Give details of amount and online receipt no. ( Document submitted Yes/ No with page no.) :-
5 Attachment 1 : Bid Security (Earnest Money Amount )- shall be valid for ninety(90) days beyond the original validity period of the bid ( Give details of amount, validity and BG Detail) Document submitted Yes/ No with page no.) :-
6 Bid Validity - upto and including 180 days reckoned from the deadline for Submission of Bids (Self declaration to be submitted by the bidder) :-
7 Details of Joint Venture (If any) as per requirement of RFP/NIT. :-
8 Form 1 Letter of Bid – Technical Part
9 Form 2 Format for Bidder Information Sheet
10 Form 3B Format of Bank Guarantee for Bid Security
11 Form 4 Format of Power of Attorney of designated Bid Signatory by sole bidder/ lead joint venture member
12 Form 5 Format of Declaration of conformance of the Bidder and the Facilities offered, to the specified eligibility requirement
13 Form 6 Format for Affidavit of Self certification regarding Local Content in line with PPP-MII order and #MoP Order/DoT order
14 Form 7 Format of Power of Attorney by Each Member/ Partner of The Joint Venture in favor of Lead Member/ Partner
15 Form 8 Format of Joint Deed of Undertaking by the Joint Venture Partners/ Members
16 Form 9 Format for Details/ Data and Documentary Evidence in support of meeting the Qualification Requirement
17 Form 10 Format of Bought-out & Sub-contracted Items
18 Form 11 Format of Undertaking on Compliance of Terms & Conditions of the Bidding Documents including Scope of Work and other related requirements
19 Form 12 Format of Alternative, Deviations and Exceptions to the Provisions of RFB Document
20 Form 13 Format of Work Completion Schedule
21 Form 14 Format of Guarantee Declaration
22 Form 15 Format of Information regarding Ex-employees
23 Form 16 Format for Price Adjustment Data
24 Form 17 Format of Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E-payment, PF details and declaration regarding Micro/Small & Medium Enterprises
25 Form 18 FORMAT OF Declaration for tax exemptions, reductions, allowances or benefits)
26 Form 19 Format of Bank Guarantee verification Check list
27 Attachment-4A : List of Special Maintenance Tools & Tackles included in bid price
28 Attachment-4B : List of Special Maintenance Tools & Tackles not included in bid price
29 Form 20 Format of Additional Information
30 Form 21 Format of Integrity Pact
31 A certificate from banker (as per specified format) indicating various fund-based limits sanctioned to the bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. 16. FORMAT FOR EVIDENCE OF ACCESS TO OR AVAILABILITY OF CREDIT/FACILITIES - BANK CERTIFICATE
32 The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid
33 Certificate from Chartered Accountants as per 20 FORM OF CERTIFICATE OF FINANCIAL PARAMETERS FOR QR (as per clause ref. no. 2 of Section 2 of Part 1)
34 Experience certificate to claim eligibility of bidder as per requirement of RFP/NIT. Work experiences of the bidder as per above shall be considered only if the works have been executed under Govt./Semi-Govt./autonomous body of Central/State Govt./Electricity Power Utility/ Power Deptt. in India only. :-
35 Liquid Asset(Rs in Cr.) (10 % of estimated cost of project ) :-
36 Net Worth of the bidder (must be positive for the each of the last three Financial Years) :-
37 MAAT (Rs. In Cr.) (30 % of estimated cost of project taken for best three years out of last five financial years ) :-
38 Bid Capacity :-
42 Minimum Manpower as per RFP( Yes/No) :-
43 Self-certified copy of the document to establish legal status of the firm viz. Certificate of Incorporation issued under The Companies Act / The Limited Liability Partnership Act / Partnership deed etc. as applicable :-
44 Copy of memorandum of association/article of association
45 Notarized affidavit to be submitted with regard to Sanction , Suspension and Prohibition as defined in RFP clause 1.3 of part -1 ( Bidding Procedure & Requirements )
46 Notarized affidavit to be submitted with regard to Non-debarrment of the firm by BSPHCL or any of its subsidiary companies i.e NBPDCL , SBPDCL , BSPGCL , BSPTCL participating in the bid either in individual capacity or in JV or by forming consortium as on the date of submission of bid .
47 Authority to seek references from banker: :-
Turnkey contract for providing New Service Connections with extension of infrastructure, if required (Phase-III) in Bhagalpur Circle
NIT No: 16 /PR/SBPDCL/2026
Bidder's Name & Address:
Sch. No Details of Work Unit Qty
A New 11 KV Lines with Bare Conductor on 9 Meter PSC Poles With ACSR Rabbit Conductor Ckm 201.00
B Distribution Transformer Substations on 9 Meter PSC Poles Nos 347
100 KVA Nos 173
C New LT Line on 8 mtr. PSC pole with AB Cables Ckm 534.00
New LT Line with 3x35 Sqmm (Ph) + 1x 25 Sqmm + 1x16 Sqmm AB Cables Ckm 267.00
New LT Line with 3x50Sqmm (Ph) + 1x 35 Sqmm + 1x16 Sqmm AB Cables Ckm 160.00
New LT Line with 3x95 Sqmm (Ph) + 1x 70 Sqmm + 1x16 Sqmm AB Cables Ckm 107.00
D 1 phase LT service connection Nos. 120647
E 3 phase LT service connection Nos 1558
E1 3 phase LT service connection ( upto 19 KW) Nos 1437
E2 3 phase LT service connection (Above 19 KW) Nos 121
E2.1 3 phase LT service connection (above 19 KW to 44 KW) Nos 59
E2.2 3 phase LT service connection (Above 44 KW) Nos 62
F HT service connection upto 150 KW Nos 54
Turnkey contract for providing New Service Connections with extension of infrastructure, if required (Phase-III) in Bhagalpur Circle
NIT No: 16 /PR/SBPDCL/2026
(Schedule of rates and prices)
Ex Works and F&I Price of Materials
Bidder's Name & Address: 0.00
All prices in Indian Rupees
Sr. No. Description Unit Unit Quantity Total Quantity Unit Ex-Work Price excluding GST Unit Price for inland transportation and other services required in India to convey the goods to their final destination Unit insurance price Total Price excluding GST .
A New 11 KV Lines With ACSR Rabbit Conductor on 9 Meter PSC Poles 201 .
1.00 Support for 11 KV overhead line as per technical specification, approved drawings and scope of work .
1.01 9 Meter 300 Kg PSC Poles along with RCC Base Plate of size 500x500x100 mm./Stone Base Plate of Size 450x450x50mm for support of base. No 25 5025 0.00 .
2.00 Galvanized Pre-fabricated steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp etc made of GI Channels, GI angle, GI flats of given sizes for over head structures as per technical specification, approved drawings and scope of work. MT 0.6 120.6 0.00 .
3.00 GI Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work. MT 0.04 8.04 0.00 .
4.00 Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (1 No.), anchor plate (200x200x6), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work. set 8 1608 0.00 .
5.00 Insulator and hardware as per technical specification, approved drawings and scope of work. .
5.01 11 kV 45 KN Polymer Disc insulator with strain hardware (1 Set= 1 No Disc with Hardware Fitting) set 12 2412 0.00 .
5.02 11 kV Polymer Pin insulator with complete set of fittings (1 Set= 1 No PIN with Hardware Fitting) set 69 13869 0.00 .
6.00 Earthing arrangement as per technical specificatons, approved drawings and scope of work. .
6.01 40 mm dia., 3000 mm long GI pipe earth electrode with all associated accessories complete for untreated earthing. set 2 402 0.00 .
6.02 8 SWG GI Coil 115 turns (1.85 kg) as per Technical Specification for untreated earthing . No 21 4221 0.00 .
7.00 ACSR Conductors of following sizes with Jointing sleeves, binding materials, PG clamps, bi-metallic clamps/connectors, hardware etc for overhead line and jumpers as required as per technical specification, approved drawings and scope of work .
7.01 ACSR Rabbit Conductor km 3.09 621.09 0.00 .
8.00 12kV, 400A, 25kA for 3sec, 3-ph, 3 Pin type, Horizontal/Vertical Mounting type , Gang Operated, AB Switch along with Support Insulators, Base Channel down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings Set 0.05 11 0.00 .
9.00 Guarding of 3 phase 11 kV line using new GI wire and earthing as per technical specification, approved drawings and scope of work. .
9.01 7/16 SWG for Guarding MT 0.013 2.613 0.00 .
9.02 8 SWG for Lacing MT 0.004 0.804 0.00 .
10.00 Supply of Signboard of size 1 foot X 1 foot made of MS Sheet 14 Gauge (1.6 mm thickness), Enamel painted with red oxide base coat and Colour printing by screen printing method alongwith suitable clamps & nut bolts as per relevant applicable standard. No 1 201 0.00 .
Sub Total 0.00 .
B Distribution Transformer Substations on 9 Meter PSC Poles DTRs in Nos .
1.00 DTR Substation Supports as per technical specification, approved drawings and scope of work. .
1.01 9 Meter 300 Kg PSC Poles along with RCC Base Plate of size 500x500x100 mm./Stone Base Plate of Size 450x450x50mm for support of base. No 2 694 0.00 0.00 0.00 0.00 .
2.00 Galvanized Pre-fabricated steel items like DC cross arm , back clamps , pole clamp, DO mounting channel, transformer mounting channel, transformer clamping set, transformer belting set etc as per technical specification, approved drawings and scope of work. MT 0.33 115 0.00 0.00 0.00 0.00 .
3.00 GI Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work. MT 0.025 9 0.00 0.00 0.00 0.00 .
4.00 Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (1 Nos.), anchor plate (200x200x6mm), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work. set 2 694 0.00 0.00 0.00 0.00 .
5.00 Insulators with hardware fittings, hardware etc as required as per technical specification, approved drawings and scope of work. .
5.01 11 kV 45 KN Polymer Disc insulator with strain hardware (1 Set= 1 No Disc with Hardware Fitting) Set 3 1041 0.00 0.00 0.00 0.00 .
5.02 11 kV Polymer Pin insulator with complete set of fittings (1 Set= 1 No PIN with Hardware Fitting) Set 3 1041 0.00 0.00 0.00 0.00 .
6.00 New Distribution Transformer with all accessories as per as per technical specification, approved drawings and scope of work. (Energy Efficiency Level -1 as per IS 1180 (Part I) 2014 with latest amendment ) .
6.01 11/0.4 KV Distribution Transformer 63 KVA 3 phase Aluminium wound DTR No 1 104 0.00 .
6.02 11/0.4 KV Distribution Transformer 100 KVA 3 phase Aluminium wound DTR No 1 173 0.00 .
6.03 11/0.4 KV Distribution Transformer 200 KVA 3 phase Aluminium wound DTR No 1 70 0.00 .
7.00 Outdoor mounting type Distribution box made of MS sheet of thickness not less than 18 SWG CRCA sheet by deep drawn method, dust and moisture vermin, weather proof with degree of protection with suitable bus bars, earthing bus, earthing terminals, box illumination, front door operated with proper locking arrangement, lugs, mounting channel frame, internal wiring with FRLS cables, danger plate, numbering, back clamps, hardware etc as per scope of the work, technical specifications and approved drawings, direction of Engineer in Charge suitable for following transformer: .
7.01 3 Ph 63 KVA Transformer having 200 A TPN isolator, 100 A HRC fuse (incomer) and 6 Nos. 60 A SP MCCB (outgoing) No 1 104 0.00 .
7.02 3 Ph 100 KVA Transformer having 200 A TPN isolator, 160A HRC fuse (incomer) and 6 Nos. 90 A SP MCCB (outgoing) No 1 173 0.00 .
7.03 3 Ph 200 KVA Transformer having 600 A TPN isolator, 315 A HRC fuse (incomer) and 9 Nos. 120 A SP MCCB (outgoing) No 1 70 0.00 .
7.04 LT Trivector Static Smart meter confirming to IS 16444 Part-2 with suitable CTs and separate LTCT . Smart meter with DI/DO should be configurable to transmit data at AMISP IT system under SBPDCL (M/s Genus- Bhagalpur and Jamui supply circles/ M/s Intellismart- other circles). The TKC will ensure availibility of OEM support for FOTA (Firmware over the air) updates required in meter e.g. TOD, other parameters/ activites updates as per DISCOM requirement. No 1 347 0.00 .
8.00 9 KV 5 KA Distribution Class Lightening Arrester for DT as per technical specification, approved drawings and scope of work. [1 Set=3 Nos] Set 1 347 0.00 .
9.00 11 kV, 3-ph, 200 A, 3 Pin type, Vertical Mounting type, Gang Operated AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings Sets 1 347 0.00 .
10.00 11 kV, 200 Amp, 3-ph, Horn Gap fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings Sets 1 347 0.00 .
11.00 3 Nos pipe earthing using 40mm dia GI pipe 3000 mm long, as per IS 1161 as per scope of work of Distribution Transformer Substations, approved drawings and technical specifications, Set 1 347 0.00 .
12.00 8 SWG GI wire for earthing of DTR Body, structure and LA as per technical specifications, approved drawings and scope of works. MT 0.004 2 0.00 .
12.01 50x3 mm GI Flats for Transformer Neutral Earthing MT 0.007 3 0.00 .
13.00 1.1 KV XLPE Aluminium Conductor, Stranded, unarmoured cable for connection of transformer LV bushing to Distribution Box and Distribution box to overhead line as per Scope of work, technical specification and approved drawings: .
13.01 1Cx70 sqmm aluminium conductor cable (For 63 KVA and 100 KVA DTR) km 0.04 11.08 0.00 .
13.02 1Cx150 sqmm aluminium conductor cable (For 200 KVA DTR) km 0.04 2.8 0.00 .
14.00 ACSR Rabbit Conductor for jumpering including PG Clamps, bi-metallic connectors, hardware etc as per technical specifications, approved drawings and scope of works. Km 0.02 7 0.00 .
15.00 Supply of Signboard of size 1 foot X 1 foot made of MS Sheet 14 Gauge (1.6 mm thickness), Enamel painted with red oxide base coat and Colour printing by screen printing method alongwith suitable clamps & nut bolts as per relevant applicable standard. No 1 347 0.00 0.00 0.00 0.00 .
Sub Total 0.00 .
C New LT Line on 8 M PSC with .
New LT Line with 3x35Sqmm (Ph) + 1x 25 Sqmm + 1x16 Sqmm AB Cables 267.00 .
New LT Line with 3x50Sqmm (Ph) + 1x 35 Sqmm + 1x16 Sqmm AB Cables 160.00 .
New LT Line with 3x95 Sqmm (Ph) + 1x 70 Sqmm + 1x16 Sqmm AB Cables 107.00 .
Total LT Lines 534.00 .
1.00 Support for LT overhead Line as per technical specification, approved drawings and scope of work. .
1.01 8 Meter 200 Kg PSC Poles along with RCC Base Plate of size 500x500x100 mm./Stone Base Plate of Size 450x450x50mm for support of base. No 30 16020 0.00 .
2.00 Galvanised Stay Set with anchor plate (200x200x6mm), 50x8mm stay clamp, 1 No Stay guy insulator, nut bolts, 2 Nos turn buckles, 1.8 m long, 16 mm diameter solid GS Stay rod & 7/3.15 mm Dia GI stranded wire etc as required as per technical specification, approved drawings and scope of work. Set 7 3738 0.00 0.00 0.00 0.00 .
3.00 Earthing as per approved drawings, technical specifications and scope of work .
3.01 8 SWG GI Coil 115 turns (1.85 kg) as per Technical Specification for untreated earthing . No 30 16020 0.00 0.00 0.00 0.00 .
4.00 LT line with following types of LT AB Cables as required as per scope of work and technical specification. .
4.03 AERIAL BUNCHED XLPE CABLE 3 X 35 SQ.MM.+1x25 SQ. MM.+ 1x16 SQ. MM. Km 1.05 280.35 0.00 .
4.04 AERIAL BUNCHED XLPE CABLE 3 X 50SQ.MM.+1x35 SQ. MM.+ 1x16 SQ. MM. Km 1.05 168 0.00 .
4.05 AERIAL BUNCHED XLPE CABLE 3 X 95 SQ.MM.+1x70 SQ. MM.+ 1x16 SQ. MM. Km 1.05 112.35 0.00 .
5.00 Supply of erection accessories for LT line with following arrangements including tension clamps for dead end, suspension clamps, clamps for neutral, eye hook with clamps, piercing connectors type-I & type-II, 16 mm dia GI nuts & bolts, pole clamps except Service Main Distribution Boxes (minimum 1 no. each pole) suitable for single phase and three phase systems etc. as required as per technical specification, approved drawings and scope of work: .
5.03 AERIAL BUNCHED XLPE CABLE 3 X 35 SQ.MM.+1x25 SQ. MM.+ 1x16 SQ. MM. per KM 1 267 0.00 .
5.04 AERIAL BUNCHED XLPE CABLE 3 X 50SQ.MM.+1x35 SQ. MM.+ 1x16 SQ. MM. per KM 1 160 0.00 .
5.05 AERIAL BUNCHED XLPE CABLE 3 X 95 SQ.MM.+1x70 SQ. MM.+ 1x16 SQ. MM. per KM 1 107 0.00 .
6.00 Supply of Service Main Distribution Boxes complete in all respect for mounting and providing service connection as per Technical Specification on new poles. .
6.01 Three Phase SMDB made from Deep Drawn Method as per Technical Specification Nos 30 14418 0.00 .
7.00 Supply of Service Main Distribution Boxes complete in all respect for mounting and providing service connection as per Technical Specification on existing poles. .
7.01 Single Phase SMDB made from Deep Drawn Method as per Technical Specification Nos 9 4806 0.00 .
7.02 Three Phase SMDB made from Deep Drawn Method as per Technical Specification Nos 2 1068 0.00 0.00 0.00 0.00 .
Sub Total 0.00 .
D Single Phase Service Connection Nos 120647 .
1.00 Single Phase Service Cable PVC insulated and PVC sheathed LT Cable for use in Service Connection size 6.0 Sqmm twin Core (unarmoured) as per IS 694-2010 multistrand Aluminum Conductor (complying with IS 8130-1976) round shaped. Average requirement of service cable is 25 Meter/Consumer & maximum length is 35 Meter & beyond 35 meter, LT extension work will be taken up. Per consumer 1 120647 0.00 .
2.00 Support/Bearer GI wire for Service wire 3.15 mm (10 SWG), Reel/Spool Insulators of 20 mm inner dia as per TS for seperating Service wire with Support GI wire on every meter and 5 Meters of 1.1 KV grade Weather-proof PVC Insulated inner sheathed unarmoured single core 1.5 sq. mm Earthwire from earth clamp to earthing terminal of Meter. Per Consumer 1 120647 0.00 .
3.00 Single Phase Double Pole 32 Amp Type-C MCB set conforming to IS: 60898 and its latest amendments and technical specification with Cover and SMC Board of minimum size of 200 mm x 200 mm x 40 mm. Per Consumer 1 120647 0.00 .
Sub Total 0.00 .
E Three Phase LT Service Connection 1558 .
E1 Three Phase LT Service Connection upto 19 KW load Nos 1437 .
1.00 Single Phase Service Cable PVC insulated and PVC sheathed LT Cable for use in Service Connection size 10.0 Sqmm four Core (unarmoured) as per IS 694-2010 multistrand Aluminum Conductor (complying with IS 8130-1976) round shaped. Average requirement of service cable is 25 Meter/Consumer & maximum length is 35 Meter & beyond 35 meter, LT extension work will be taken up. Per consumer 1 1437 0.00 .
2.00 Support/Bearer GI wire for Service wire 4.00 mm (8 SWG), Reel/Spool Insulators of 20 mm inner dia as per TS for seperating Service wire with Support GI wire on every meter and 5 Meters of 1.1 KV grade Weather-proof PVC Insulated inner sheathed unarmoured single core 1.5 sq. mm Earthwire from earth clamp to earthing terminal of Meter. Per Consumer 1 1437 0.00 .
3.00 Three Phase Triple Pole 32 Amp Type-C MCB set conforming to IS: 60898 and its latest amendments and technical specification with Cover and SMC Board of minimum size of 200 mm x 200 mm x 40 mm. Per Consumer 1 1437 0.00 .
Sub Total 0.00 .
E2 Three Phase LT Service Connection above 19 KW load Nos 121 .
1.00 For Load of service connection (20 KW to 44 KW) .
1.01 3.5CX 50 sq mm LT XLPE armoured Cable. Average requirement of service cable is 25 Meter/Consumer & maximum length is 35 Meter & beyond 35 meter, LT extension work will be taken up. Per consumer 1 59 0.00 .
2.00 For Load of service connection (avove 44 KW) .
2.02 3.5CX 70 sq mm LT XLPE armoured Cable. Average requirement of service cable is 25 Meter/Consumer & maximum length is 35 Meter & beyond 35 meter, LT extension work will be taken up. Per Consumer 1 62 0.00 .
Sub Total 0.00 .
F HT service connection upto 150 KW load 54 .
1.00 DTR Substation Supports as per technical specification, approved drawings and scope of work. .
1.01 11 m long H-Beam/RS Joist Poles(UC152, 37 Kg/Meter) along with RCC Base Plate of size 500x500x100 mm./Stone Base Plate of Size 450x450x50mm for support of base as per Technical Specification and approved drawing. No 2 108 0.00 .
2.00 Galvanized Pre-fabricated steel items like DC cross arm , back clamps , pole clamp, DO mounting channel, transformer mounting channel, transformer clamping set, transformer belting set etc as per technical specification, approved drawings and scope of work. MT 0.33 17.82 0.00 0.00 0.00 0.00 .
3.00 GI Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work. MT 0.03 1.35 0.00 0.00 0.00 0.00 .
4.00 Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (1 Nos.), anchor plate (200x200x6mm), nut bolts, 2 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work. set 2 108 0.00 0.00 0.00 0.00 .
5.00 Insulators with hardware fittings, hardware etc as required as per technical specification, approved drawings and scope of work. .
5.01 11 kV 45 KN Polymer Disc insulator with strain hardware (1 Set= 1 No Disc with Hardware Fitting) Set 3 162 0.00 0.00 0.00 0.00 .
5.02 11 kV Polymer Pin insulator with complete set of fittings (1 Set= 1 No PIN with Hardware Fitting) Set 3 162 0.00 0.00 0.00 0.00 .
6.00 9 KV 5 KA Distribution Class Lightening Arrester for DT as per technical specification, approved drawings and scope of work. [1 Set=3 Nos] Set 1 54 0.00 0.00 0.00 0.00 .
7.00 11 kV, 3-ph, 200 A, 3 Pin type, Vertical Mounting type, Gang Operated AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings Sets 1 54 0.00 0.00 0.00 0.00 .
8.00 11 kV, 200 Amp, 3-ph, Horn Gap fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings Sets 1 54 0.00 0.00 0.00 0.00 .
9.00 3 Nos pipe earthing using 40mm dia GI pipe 3000 mm long, as per IS 1161 as per scope of work of Distribution Transformer Substations, approved drawings and technical specifications, Set 1 54 0.00 0.00 0.00 0.00 .
10.00 ACSR Rabbit Conductor for jumpering including PG Clamps, bi-metallic connectors, hardware etc as per technical specifications, approved drawings and scope of works. Km 0.02 1.08 0.00 0.00 0.00 0.00 .
11.00 8 SWG GI wire for earthing of DTR Body, structure and LA as per technical specifications, approved drawings and scope of works. MT 0.004 108 0.00 0.00 0.00 0.00 .
12.00 50x3 mm GI Flats for Transformer Neutral Earthing MT 0.007 108 0.00 0.00 0.00 0.00 .
13.00 Supply of Signboard of size 1 foot X 1 foot made of MS Sheet 14 Gauge (1.6 mm thickness), Enamel painted with red oxide base coat and Colour printing by screen printing method alongwith suitable clamps & nut bolts as per relevant applicable standard. No 1 54 0.00 0.00 0.00 0.00 .
14.00 Supply of 12 core 2.5 sq mm copper armoured cable with 40 sq. mm inner dia GI pipe with allied materials. Average requirement of cable is 20 Meter/Consumer & maximum length is 30 Meter Per Consumer 1 54 0.00 .
Sub Total 0.00 .
Grand Total 0.00 .
Turnkey contract for providing New Service Connections with extension of infrastructure, if required (Phase-III) in Bhagalpur Circle
NIT No: 16 /PR/SBPDCL/2026
(Schedule of Rates and Prices)
Installation / Erection Charges :
Bidder's Name & Address: 0.00
All prices in Indian Rupees
Sl. No. Description Unit Unit Quantity Quantity Unit Erection Price exclusive of GST (amount in Rs.) Total Erection Price exclusive of GST (amount in Rs. ) .
A New 11 KV Lines With ACSR Rabbit Conductor on 9 Meter PSC Poles CKm 201 .
1.00 Survey, route alignment & pole spotting, preparation of survey report and uploading in the web portal after approval of Project Manager/Engineer in Charge. CKm 1 201 0.00 .
2.00 Erection of following types of poles (SP/DP/TP/FP structrues) for 11 KV overhead line by providing and installing danger plate, anti-climbing devices (barbed wire) with clamps, earthing material (using coil/pipe and providing and using 8SWG GI wire), red oxide & aluminium paint (For RS Joist and Rail Poles), pole numbering including foundation etc as per scope of work, approved drawings and technical specifications: .
2.01 9 Meter 300 Kg PSC Poles along with RCC Base Plate of size 500x500x100 mm./Stone Base Plate of Size 450x450x50mm for support of base including excavation of Pole Pit (of depth 1/6th of pole length), refilling by bolders using 200 mm average size bolders/Brick Bats mixed with excavated earth [50:50] No 25 4020 0.00 .
2.02 9 Meter 300 Kg PSC Poles along with RCC Base Plate of size 500x500x100 mm./Stone Base Plate of Size 450x450x50mm for support of base including Excavation of Pole Pit (of depth 1/6th of pole length), cement concrete foundation using 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) (0.65 cmt/pole for Rail/Poles and 0.46 cmt/PSC Pole) No 25 1005 0.00 .
3.00 Erection, testing & commissioning of Galvanized pre-fabricated steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, etc made of GI Channels, GI angle, GI flats of given sizes for over head structures and GI nuts, bolts & washers including painting by red oxide & aluminium paint as per technical specification, approved drawings and scope of work. MT 0.6 120.6 0.00 .
4.00 Earthing arrangement as per technical specificatons, approved drawings and scope of work. .
4.01 Excavation, erection, testing & commissioning of 40 mm dia., 3000 mm long GI pipe earth electrode with all associated accessories complete for untreated earthing Set 2 402 0.00 .
4.02 Erection of 8 SWG GI Coil 115 turns (1.85 kg) with all associated accessories complete in all respect for untreated earthing. Set 21 4221 0.00 .
6.00 Erection of complete stay set along with excavation of Stay pit with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (1 Nos.) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications, approved drawings and scope of works. Set 8 1608 0.00 .
7.00 Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work. .
7.01 11 kV Polymer Pin insulator with complete set of fittings Set 69 13869 0.00 .
7.02 11 kV 45 KN Polymer Disc insulator with strain hardware Set 12 2412 0.00 .
8.00 Paying out, tensioning, binding of conductor and tightening of stays and stringing, testing and commissioning of ACSR Conductor of following sizes including jointing sleeves, helical formed fittings, jumpering and by providing & erecting PG Clamps etc as required as per approved drawings, scope of work and technical specifications .
8.01 ACSR Rabbit Conductor Ckm 1 201 0.00 .
9.00 Erection, Testing and Commissioning of 12 KV AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings Set 0.05 11 0.00 .
10.00 Erection, testing & commissioning of new GI wire for earthing and guarding as per technical specification, approved drawings and scope of work. .
10.01 7/16 SWG for Guarding MT 0.013 2.613 0.00 .
10.02 8 SWG for Lacing MT 0.004 0.804 0.00 .
11.00 Erection of Signboard of size 1 foot X 1 foot made of MS Sheet 14 Gauge (1.6 mm thickness), Enamel painted with red oxide base coat and Colour printing by screen printing method alongwith suitable clamps & nut bolts on Double pole structure as per relevant applicable standard and scope of work and approved drawings. No 1 201 0.00 .
Sub Total 0.00 .
B Distribution Transformer Substations on 9 Meter PSC Poles DTRs in Nos .
1.00 Survey, route alignment & pole spotting, preparation of survey report and uploading in the web portal after approval of Project Manager/Engineer in Charge Nos 1.00 347 0.00 .
2.00 Erection of following types of poles for Distribution Sub Stations by providing and installing danger plate, anti-climbing devices (barbed wire) with clamps, earthing material (using coil/pipe and providing and using 8SWG GI wire), red oxide & aluminium paint, pole numbering including Excavation of Pole Pit (of depth 1/6th of pole length), cement concrete foundation using 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) (0.65 cmt/pole for Rail/Poles and 0.46 cmt/PSC Pole) etc as per scope of work, approved drawings and Technical specifications: .
2.01 9 Meter 300 Kg PSC Poles along with RCC Base Plate of size 500x500x100 mm./Stone Base Plate of Size 450x450x50mm for support of base. No 2 694 0.00 .
3.00 Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (1 Nos.) and Excavation of Stay Pit, 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications, approved drawings and scope of works. Set 2 694 0.00 0.00 .
4.00 Erection, testing, commissioning of Galvanized Pre-fabricated steel items like DC cross arm, back clamps, pole clamp, DO mounting channel, transformer mounting channel, transformer clamping set, transformer belting set and GI nuts, bolts & washers including painting by red oxide & aluminium as per technical specification, approved drawings and scope of work. MT 0.33 115 0.00 .
5.00 Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work. .
5.01 11 kV 45 KN Polymer Disc insulator with strain hardware Set 3 1041 0.00 0.00 .
5.02 11 kV Polymer Pin insulator with complete set of fittings Set 3 1041 0.00 0.00 .
6.00 Erection, Testing and Commissioning of Distribution Transformer with all accessories as per scope of work, approved drawings and specifications: .
6.01 11/0.4 KV Distribution Transformer 63 KVA 3 phase Aluminium wound DTR No 1 104 0.00 .
6.02 11/0.4 KV Distribution Transformer 100 KVA 3 phase Aluminium wound DTR No 1 173 0.00 .
6.03 11/0.4 KV Distribution Transformer 200 KVA 3 phase Aluminium wound DTR No 1 70 0.00 .
7.00 Erection, testing and Commissioning of Outdoor mounting type Distribution box made of MS sheet of thickness not less than 18 SWG CRCA sheet by deep drawn method, dust and moisture vermin, weather proof with degree of protection with suitable bus bars, earthing bus, earthing terminals, box illumination, front door operated with proper locking arrangement, lugs, mounting channel frame, internal wiring with FRLS cables, danger plate, numbering, back clamps, hardware etc as per scope of the work, technical specifications and approved drawings, direction of Engineer in Charge suitable for following transformer: .
7.03 3 Ph 63 KVA Transformer having 200 A TPN isolator, 100 A HRC fuse (incomer) and 6 Nos. 60 A SP MCCB (outgoing) No 1 104 0.00 .
7.02 3 Ph 100 KVA Transformer having 200 A TPN isolator, 160A HRC fuse (incomer) and 6 Nos. 90 A SP MCCB (outgoing) No 1 173 0.00
7.01 3 Ph 200 KVA Transformer having 600 A TPN isolator, 315 A HRC fuse (incomer) and 9 Nos. 120 A SP MCCB (outgoing) No 1 70 0.00
7.04 LT Trivector Static Smart meter confirming to IS 16444 Part-2 with suitable CTs and separate LTCT . No 1 347 0.00 .
8.00 Erection, testing and Commissioning of 3 Nos treated pipe earthing using 40mm dia GI pipe 3000 mm long, as per IS 1161 as per scope of work, approved drawings and technical specifications. Set 1 347 0.00 .
9.00 Erection, testing and commissioning of 8 SWG GI wires for connection of earthing to LA, Structure and DTR body as per Scope of work, technical specification and approved drawings MT 0.004 1.39 0.00 .
9.01 Erection, testing and commissioning of 50x3 mm GI flats for connection to Earthing with Neutral of DTR as per Scope of work, technical specification and approved drawings MT 0.007 2.43 0.00 .
10.00 Erection, testing and Commissioning of 1.1 KV XLPE Aluminium Conductor, Stranded, unarmoured cable for connection of transformer LV bushing to Distribution Box and Distribution box to overhead line as per Scope of work, technical specification and approved drawings: .
10.01 1Cx70 sqmm aluminium conductor cable ( For 63 KVA DTR & 100 KVA ) km 0.04 11.08 0.00 .
10.02 1Cx150 sqmm aluminium conductor cable km 0.04 2.8 0.00 .
11.00 Erection, testing and commissioning of ACSR Rabbit Conductor for jumpering including PG Clamps, bi-metallic connectors, hardware etc as per Technical Specification, approved Drawing & Scope of works Km 0.02 6.94 0.00 .
12.00 Erection, testing and Commissioning of 11 KV, 200 A, 3-pole AB Switch for Distribution Transformer Substation as per Technical Specification, approved Drawing & Scope of works Sets 1 347 0.00 .
13.00 Erection, testing and commissioning of 9 KV, 5 KA Distribution Class Lightening Arrester for DT as per technical specification, approved drawings and scope of work. [1 Set=3 Nos] Set 1 347 0.00 .
14.00 Erection, testing and commissioning of 11 kV, 200 Amp 3-ph, Horn Gap fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings Sets 1 347 0.00 .
15.00 Erection of Signboard of size 1 foot X 1 foot made of MS Sheet 14 Gauge (1.6 mm thickness), Enamel painted with red oxide base coat and Colour printing by screen printing method alongwith suitable clamps & nut bolts on Double pole structure as per relevant applicable standard and scope of work and approved drawings. No 1 347 0.00 0.00 .
Sub Total 0.00 .
C New LT Line on 8 M PSC with in CKM .
New LT Line with 3x35 Sqmm (Ph) + 1x 25 Sqmm + 1x16 Sqmm AB Cables 267.00 .
New LT Line with 3x50Sqmm (Ph) + 1x 35 Sqmm + 1x16 Sqmm AB Cables 160.00 .
New LT Line with 3x95 Sqmm (Ph) + 1x 70 Sqmm + 1x16 Sqmm AB Cables 107.00 .
Total LT Lines 534.00 .
1.00 Survey, route alignment & pole spotting, preparation of survey report and uploading in the web portal after approval of Project Manager CKm 1 534.00 0.00 .
2.00 Erection of following types of poles (SP/DP/TP/FP structrues) for LT overhead line by providing and installing danger plate, anti-climbing devices (barbed wire) with clamps, earthing material (using coil/pipe and providing and using 8SWG GI wire), red oxide & aluminium paint (For Tubular Poles), pole numbering including foundation etc as per scope of work, approved drawings and technical specifications: .
2.01 8 Meter 200 Kg PSC Poles along with RCC Base Plate of size 500x500x100 mm./Stone Base Plate of Size 450x450x50mm for support of base including excavation of Pole Pit (of depth 1/6th of pole length), refilling by bolders using 200 mm average size bolders/Brick Bats mixed with excavated earth [50:50] No 30 16020.00 0.00 .
3.00 Erection of galvanised Stay Set with 50x8mm stay clamp, stay guy insulator, nut bolts, 2 Nos turn buckle's, 1.8 m long, 16 mm diameter solid GS Stay rod & 7/3.15 mm Dia GI stranded wire etc as required by exacavation of Stay pit, providing 0.2 cmt cement concrete as per approved drawings, technical specification and scope of work. *The scope of work mandatory includes removal of service connection from service line and reconnection of all service wires with all accessories in new SMDB with proper termination Set 7 3738.00 0.00 0.00 .
4.00 Earthing arrangement as per technical specificatons, approved drawings and scope of work. .
4.01 Erection of 8 SWG GI Coil 115 turns (1.85 kg) with all associated accessories complete in all respect for untreated earthing. Set 30 16020.00 0.00 0.00 .
5.00 Erection, testing & commissioning of new areal bunched XLPE cable along with all complete accessories such as tension clamps for dead end, suspension clamps, clamps for neutral, piercing connectors type-I & type-II, 16 mm dia GI nuts & bolts, pole clamps, Steel Straps, junction Sleeves, Jointing and Termination Accessories, Buckles etc except Service Main Distribution Boxes suitable for single & three phase systems as required as per technical specification, approved drawings and scope of work .
5.03 AERIAL BUNCHED XLPE CABLE 3 X 35 SQ.MM.+1x25 SQ. MM.+ 1x16 SQ. MM. Ckm 1 267.00 0.00 .
5.04 AERIAL BUNCHED XLPE CABLE 3 X 50 SQ.MM.+1x35 SQ. MM.+ 1x16 SQ. MM. Ckm 1 160.00 0.00 .
5.05 AERIAL BUNCHED XLPE CABLE 3 X 95 SQ.MM.+1x70 SQ. MM.+ 1x16 SQ. MM. Ckm 1 107.00 0.00 .
6.00 Installation and mounting of SMDB Boxes with galvanized MS clamp of 40x3 mm size along with connection with AB Cable along with all accessories complete in all aspect as per technical Specification and approved drawing on new poles. .
6.01 Three Phase SMDB Nos 30 16020 0.00 .
7.00 Installation and mounting of SMDB Boxes with galvanized MS clamp of 40x3 mm size along with connection with AB Cable along with all accessories complete in all aspect as per technical Specification and approved drawing on existing poles. .
7.01 Single Phase SMDB Nos 9 4806 0.00 .
7.02 Three Phase SMDB Nos 2 1068 0.00 0.00 .
Sub Total 0.00 .
D Single Phase Service Connection Nos 120647 .
Taking delivery from TKC stores, loading, transportation, unloading at site and Installation of Service Connection at Door Bell location with MCB on SMC board, grouting & fixing of eye hook anchor fastner with support arrangement of sutable size and use of admixture of Cement, Sand, Chips along with fitting of Anchor Bolts, Saddle clamps etc as per requirement, Stringing of Service wire and providing connection from SMDB Boxes along with support of GI wire and Reel insulators, connection of GI wire form earth wire of LT line, Connection of Earthing terminal with support GI wire and connection with earthing of consumer (if any) as per adopting procedure given below/Technical Specification and miscellaneous work for completion of service connection work. Bearer wire will be connected to earth wire on the pole of LT system. Draw a PVC earth wire through support eye hook anchor fastner for earthing whose one end is connected to bearer wire/GI wire near eye hook and another end to earth knob/bolt mounted on SMC board. If earthing system is available in the premises of consumer then the earth wire of system will be connected to earth knob/bolt. In case service connection is to be provided from Bare Conductor, a U Loop has to be provided which is made of ACSR Weasel Conductor as per Size and dimension attached " U Loop Drawing" (Total length of ACSR Conductor is 28 Inches, and required binding wire of 3.35 mm size (equivallent to Al strand of ACSR Rabbit Conductor) to bind the conductor with existing line) .
1.00 Stringing of service wire from pole to MCB at consumer premises with proper support arrangement. 1 120647 0.00 .
2.00 Stringing Bearer wire/ GI wire of 10 SWG to support service wire, fixing of standard and suitable size of eye hook anchor fastner with support arrangement. Support service wire with Bearer wire with Reel/Spool Insulators of 20 mm/suitable size inner dia as per TS for seperating Service wire with Support GI wire on every meter (for isolating the PVC from bearer wire) from overhead LT line (SMDB/Bare Conductor) up to eye hook anchor fastner. 1 120647 0.00 .
3.00 Fitting of MCB on SMC board and its allied fittings/connections with complete work. 1 120647 0.00 .
Sub Total 0.00 .
E Three Phase LT Service Connection 1558 .
E1 Three Phase LT Service Connection upto 19 KW load Nos 1437 .
Taking delivery from TKC stores, loading, transportation, unloading at site and Installation of Service Connection at Door Bell location with MCB on SMC board, grouting & fixing of eye hook anchor fastner with support arrangement of sutable size and use of admixture of Cement, Sand, Chips along with fitting of Rag bolts/Anchor Bolts, Saddle clamps, Earth Clamps etc as per requirement, Stringing of Service wire and providing connection from SMDB Boxes along with support of GI wire and Reel insulators, connection of GI wire form earth wire of LT line, Connection of Earthing terminal of Meter/MCB with support GI wire and connection with earthing of consumer (if any) as per adopting procedure given below/Technical Specification and miscellaneous work for completion of service connection work. Bearer wire will be connected to earth wire on the pole of LT system. Draw a PVC earth wire through support eye hook anchor fastner for earthing whose one end is connected to bearer wire/GI wire near eye hook and another end to earth knob/bolt mounted on meter board/ SMC board. If earthing system is available in the premises of consumer then the earth wire of system will be connected to earth knob/bolt. In case service connection is to be provided from Bare Conductor, a U Loop has to be provided which is made of ACSR Weasel Conductor as per Size and dimension attached " U Loop Drawing" (Total length of ACSR Conductor is 28 Inches, and required binding wire of 3.35 mm size (equivallent to Al strand of ACSR Rabbit Conductor) to bind the conductor with existing line) .
1.00 Stringing of service wire from pole to MCB at consumer premises with proper support arrangement. 1 1437 0.00 0.00 .
2.00 Stringing Bearer wire/ GI wire of 8 SWG to support service wire, fixing of standard and suitable size of eye hook anchor fastner with support arrangement. Support service wire with Bearer wire with Reel/Spool Insulators of 20 mm/suitable size inner dia as per TS for seperating Service wire with Support GI wire on every meter (for isolating the PVC from bearer wire) from overhead LT line (SMDB/Bare Conductor) up to eye hook anchor fastner. 1 1437 0.00 0.00 .
3.00 Fitting of MCB on SMC board and its allied fittings/connections with complete work 1 1437 0.00 0.00 .
Sub Total 0.00 .
E2 Three Phase LT Service Connection above 19 KW load Nos 121 .
Taking delivery from TKC stores, loading, transportation, unloading at site and Installation of Service Connection at Door Bell location with MCB on SMC board, grouting & fixing of eye hook anchor fastner with support arrangement of sutable size and use of admixture of Cement, Sand, Chips along with fitting of Rag bolts/Anchor Bolts, Saddle clamps, Earth Clamps etc as per requirement, Stringing of Service wire and providing connection from SMDB Boxes along with support of GI wire and Reel insulators, connection of GI wire form earth wire of LT line, Connection of Earthing terminal of Meter/MCB with support GI wire and connection with earthing of consumer (if any) as per adopting procedure given below/Technical Specification and miscellaneous work for completion of service connection work. Bearer wire will be connected to earth wire on the pole of LT system. Draw a PVC earth wire through support eye hook anchor fastner for earthing whose one end is connected to bearer wire/GI wire near eye hook and another end to earth knob/bolt mounted on meter board/ SMC board. If earthing system is available in the premises of consumer then the earth wire of system will be connected to earth knob/bolt. In case service connection is to be provided from Bare Conductor, a U Loop has to be provided which is made of ACSR Weasel Conductor as per Size and dimension attached " U Loop Drawing" (Total length of ACSR Conductor is 28 Inches, and required binding wire of 3.35 mm size (equivallent to Al strand of ACSR Rabbit Conductor) to bind the conductor with existing line) .
1.00 For Load of service connection (20 KW to 44 KW) .
1.01 Stringing of 3.5CX 50 sq mm LT XLPE armoured Cable from overhead LT line (SMDB/Bare Conductor) to consumer premises with proper support arrangement, fixing of standard and suitable size of eye hook anchor fastners with support arrangement/ fixing of angle/ clamps to support service cable. 1 59 0.00 .
2.00 For Load of service connection (avove 44 KW) .
2.01 Stringing of 3.5CX 70 sq mm LT XLPE armoured Cable from overhead LT line (SMDB/Bare Conductor) to consumer premises with proper support arrangement, fixing of standard and suitable size of eye hook anchor fastners with support arrangement/ fixing of angle/ clamps to support service cable. 1 62 0.00 0.00 .
3.00 Fitting of meter with meter box & its allied fittings/connections complete work. 1 121 0.00
Sub Total 0.00 .
F HT service connection upto 150 KW load 54 .
1.00 Survey and erection of following types of poles for Distribution Sub Stations by providing and installing danger plate, anti-climbing devices (barbed wire) with clamps, earthing material (using coil/pipe and providing and using 8SWG GI wire), red oxide & aluminium paint, pole numbering including Excavation of Pole Pit (of depth 1/6th of pole length), cement concrete foundation using 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) with top muffing (0.65 cmt/pole for RS Joist Poles) etc as per scope of work, approved drawings and Technical specifications: .
1.01 11 m long H-Beam/RS Joist Poles along with RCC Base Plate of size 500x500x100 mm./Stone Base Plate of Size 450x450x50mm for support of base as per Technical Specification and approved drawing. No 2.00 108 0.00 .
2.00 Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (1 Nos.) and Excavation of Stay Pit, 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications, approved drawings and scope of works. Set 2 108 0.00 0.00 .
3.00 Erection, testing, commissioning of Galvanized Pre-fabricated steel items like DC cross arm, back clamps, pole clamp, DO mounting channel, transformer mounting channel, transformer clamping set, transformer belting set and GI nuts, bolts & washers including painting by red oxide & aluminium as per technical specification, approved drawings and scope of work. MT 0.33 17.82 0.00 0.00 .
4.00 Erection, testing and commissioning of 11 kV insulator including their hardware fittings as per technical specification, approved drawings and scope of work. .
4.01 11 kV 45 KN Polymer Disc insulator with strain hardware Set 3 162 0.00 0.00 .
4.02 11 kV Polymer Pin insulator with complete set of fittings Set 3 162 0.00 0.00 .
5.00 Erection, testing and Commissioning of 3 Nos treated pipe earthing using 40mm dia GI pipe 3000 mm long, as per IS 1161 as per scope of work, approved drawings and technical specifications. Set 1 54 0.00 0.00 .
6.00 Erection, testing and commissioning of 8 SWG GI wires for connection of earthing to LA, Structure and DTR body as per Scope of work, technical specification and approved drawings MT 0.004 0.216 0.00 0.00 .
7.00 Erection, testing and commissioning of 50x3 mm GI flats for connection to Earthing with Neutral of DTR as per Scope of work, technical specification and approved drawings MT 0.01 0.378 0.00 0.00 .
8.00 Erection, testing and Commissioning of 11 KV, 200 A, 3-pole AB Switch for Distribution Transformer Substation as per Technical Specification, approved Drawing & Scope of works Sets 1 54 0.00 0.00 .
9.00 Erection, testing and commissioning of 9 KV, 5 KA Distribution Class Lightening Arrester for DT as per technical specification, approved drawings and scope of work. [1 Set=3 Nos] Set 1 54 0.00 0.00 .
10.00 Erection, testing and commissioning of 11 kV, 200 Amp 3-ph, Horn Gap fuse units (set of 3 units) along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings Sets 1 54 0.00 0.00 .
11.00 Erection of Signboard of size 1 foot X 1 foot made of MS Sheet 14 Gauge (1.6 mm thickness), Enamel painted with red oxide base coat and Colour printing by screen printing method alongwith suitable clamps & nut bolts on Double pole structure as per relevant applicable standard and scope of work and approved drawings. No 1 54 0.00 0.00 .
12.00 Erection of 12 core 2.5 sq mm copper armoured cable with 40 sq. mm inner dia GI pipe with allied materials. Per Consumer 1 54 0.00 .
13.00 Transportation and erection of metering unit and meter with meter box & its allied fittings/connections complete work. Per Consumer 1 54 0.00
Sub Total 0.00 .
Grand Total 0.00 .
Turnkey contract for providing New Service Connections with extension of infrastructure, if required (Phase-III) in Bhagalpur Circle
NIT No: 16 /PR/SBPDCL/2026
All prices in Indian Rupees
Bidder's Name and Address: 0.00
Sl. No. Description Cost (in Rs.)
1 TOTAL SCHEDULE NO. 1 & 2: Ex Works Price of Materials and F& I
a Total cost of Plants & Equipments exclusive of GST 0.00
2 TOTAL SCHEDULE NO. 3 : Installation / Erection Charges
a Total Erection Price exclusive of GST 0.00
3 Total Price (1+2) 0.00
4 TOTAL SCHEDULE NO. 4 : Applicable GST
a Applicable GST @ 18%(CGST @9 %+ SGST@9 %) 0.00
Turnkey contract for providing New Service Connections with extension of infrastructure, if required (Phase-III) in Bhagalpur Circle
NIT No: 16 /PR/SBPDCL/2026
All prices in Indian Rupees
(GRAND SUMMARY)
Bidder's Name and Address: 0.00
Sl. No. Description Cost (in Rs.)
1 TOTAL SCHEDULE NO. 1 & 2: Ex Works Price of Materials and F& I
a Total cost of Plants & Equipments exclusive of GST 0.00
2 TOTAL SCHEDULE NO. 3 : Installation / Erection Charges
a Total Erection Price exclusive of GST 0.00
3 Total Price (1+2) 0.00
4 TOTAL SCHEDULE NO. 4 : Applicable GST
a Applicable GST @ 18%(CGST @9 %+ SGST@9 %) 0.00
6 Discount offerred by Bidder (If any)
7 Grand Total (5-6): Bid Price for evaluation and award 0.00
Designation: AUTHORIZED SIGNATORY
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT No. - 16 to 26 NSC PHASE III.pdf
NIT • 0.61 MB
NIT No. - 16 to 26 NSC PHASE III.pdf
NIT • 0.61 MB
1. NSC PHASE III_Part 1.docx
NIT • 2.72 MB
2A. NSC PHASE III_Part 2.docx
NIT • 0.55 MB
2B. NSC PHASE III_Part 2_TS.docx
NIT • 10.86 MB
3 NSC PHASE III_Part 3.docx
NIT • 0.31 MB
ABCableAccessories Multi port.pdf
NIT • 0.55 MB
FABRICATED ITEMS TS.pdf
NIT • 0.53 MB
Service Connection Materials.pdf
NIT • 0.30 MB
19761_Tech Spec of LT AB Cables.pdf
NIT • 0.10 MB
21124_Tech spec Covered conductor and its accesories.pdf
NIT • 1.10 MB
21378_TSforPSCPole.pdf
NIT • 0.81 MB
Sign Board New Line and DTR.pdf
NIT • 0.40 MB
Infra_SBE_Tender Drawings_Version-2 Part 1.pdf
NIT • 6.72 MB
Infra_SBE_Tender Drawings_Version-2 Part 2.pdf
NIT • 9.15 MB
TC Bid of NIT-16 to 26.xlsx
NIT • 0.02 MB
PENALTY.pdf
NIT • 2.01 MB
TS CONTROL CABLE AND UG CABLE.pdf
NIT • 1.90 MB
BOQ NIT 16 NSC3 BHAGALPUR.xlsx
NIT • 0.06 MB
Download all tender documents and submit your bid