Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹40.0 L
EMD Value
₹79,980
Closing Date
25 Nov 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE SOUTH
NO 1 GEN BHAGAT MARG PUNE 40
8915 REPAIR REPLACEMENT AND CLEANING OF MANHOLES SEWAGE LINE SEPTIC TANK SOAKAGE WELL AND CONNECTED MISC BR WORKS IN MD ACCN OTM ACCN OF OLD CH COMPLEX LOWER HOSP ROAD KT LINE ALC QTR WANWORIE ROAD GWALIOR LINE OLD CH SC UNDER AGE BR II GE S PUNE
2026_MES_797200_1
8915 GE SOUTH PUNE
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE SOUTH PUNE
₹79,980
Yes
4 Nov 2026
4 Nov 2026
2 Dec 2026
4 Nov 2026
25 Nov 2026
18 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depth for foundations, and getting out in any type of soil complete all as specified and as directed.Note:The Contractor is solely responsible for any damage to existing cables,pipes,or utilities caused during carrying out work and must repair and restore them to their original condition at their own expense. | 210 | Cum | - | - |
| - | Excavation in trenches exc 1.5 & not exc 3mtr in depth for foundation and getting out in any type of soil complete all as specified and as directed.Note:The Contractor is solely responsible for any damage to existing cables,pipes,or utilities caused during carrying out work and must repair and restore them to their original condition at their own expense. | 3 | Cum | - | - |
| - | S&F for 150 mm dia HDPE DWC pipes, Class SN 8, ante rodent, laid and jointed complete including demolition and breaking up RCC, SWG, CPVC drain pipe complete all as specified and as directed.
(Note :- Laying of sewage line in running sewage water & temporary diversion /plugged of existing sewage line & bailing of sewage water and removing demolished pipe from the site are the responsibility of contractor and the rate for the same is seems to be included in the contract) | 250 | RM | - | - |
| - | M&L for 100 mm thick and 550 mm wide Concrete bed to drain pipes in PCC 1:4:8 type D2 using 40mm graded agg as in bed to 150 mm dia HDPE DWC pipes complete all as specified and as directed. | 225 | RM | - | - |
| - | S&F for 150mm bore reinforced concrete pipes, class NP2, laid and jointed complete with collars including demolition and breaking up RCC, SWG, CPVC drain pipe complete all as specified and as directed.
(Note :- Laying of sewage line in running sewage water & temporary diversion /plugged of existing sewage line & bailing of sewage water and removing demolished pipe from the site are the responsibility of contractor and the rate for the same is seems to be included in the contract). | 45 | RM | - | - |
| - | M&L for Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in PCC 1:4:8 type D2 using 40mm graded agg as in bed to drain pipes of 150 mm bore complete all as specified and as directed. | 40.5 | RM | - | - |
| - | S&F for 200 mm dia HDPE DWC pipes, Class SN 8, ante rodent, laid and jointed complete including demolition and breaking up RCC, SWG, CPVC drain pipe complete all as specified and as directed.
(Note :- Laying of sewage line in running sewage water & temporary diversion /plugged of existing sewage line & bailing of sewage water and removing demolished pipe from the site are the responsibility of contractor and the rate for the same is seems to be included in the contract) | 30 | RM | - | - |
| - | M&L for 100 mm thick and 600 mm wide Concrete bed to drain pipes in PCC 1:4:8 type D2 using 40mm graded agg as in bed to 200 mm dia HDPE DWC pipes complete all as specified and as directed. | 27 | RM | - | - |
| - | S&F for 200mm bore reinforced concrete pipes, class NP2, laid and jointed complete with collars including deomolition and breaking up RCC, SWG, CPVC drain pipe complete all as specified and as directed.
(Note :- Laying of sewage line in running sewage water & temporary diversion /plugged of existing sewage line & bailing of sewage water and removing demolished pipe including from the site are the responsibility of contractor and the rate for the same is seems to be included in the contract). | 25 | RM | - | - |
| - | M&L for Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in PCC 1:4:8 type D2 using 40mm graded agg as in bed to drain pipes of 200 mm bore complete all as specified and as directed. | 22.5 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.08 MB
8915TenderDocs.pdf
Tender Documents • 0.65 MB
BOQ_894219.xls
BOQ • 0.77 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .