Dy manager Purchase ES
Bharat Electronics Limited Jalahalli Post Bengaluru 560 013
Supply Erection Installation Testing and commissioning of Tower Split Air Conditioning System for Mechanical department BEL Bangalore
2026_BEL_100680_1
ES9/2026/21046757406/A29
Open Tender
Miscellaneous Goods
Supply
BEL Banglore
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
13 Nov 2026
29 Oct 2026
14 Nov 2026
29 Oct 2026
13 Nov 2026
29 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1PART-A SUPPLY | |||||
| 1.01 | Supply of Tower Split AC
(Supply of Tower Split AC of capacity not less than 3.0TR of rotary / scroll compressor, aircooled condensing unit with copper cooling coil, fan motor and indoor unit complete with filter section, cooling coil of copper tubes with aluminium fins, electric motor, fans including initial charge of R32 refrigerant and subsequent charge / tapping of refrigerant during testing / commissioning if any, etc. as required, including minor civil works like core cutting, MS stand / supports for AC units all as specified and / or directed etc.,complete.
Quoted price shall include cost of wireless remote controller, outdoor unit stand,cooling thermostat, wiring, control cabling and earthing. Unit shall be provided with auto clean mode, auto timer setting and as per specifications.) | 2 | Nos | - | - |
| 2PART-B Installation, testing & commissioning | |||||
| 2.01 | Erection, Testing & commissioning Tower Split AC
(Erection, testing and commissioning Tower Split AC of capacity not less than 3.0TR of rotary / scroll compressor, aircooled condensing unit with copper cooling coil, fan motor and indoor unit complete with filter section, cooling coil of copper tubes with aluminium fins, electric motor, fans including initial charge of R32 refrigerant and subsequent charge / tapping of refrigerant during testing / commissioning if any, etc. as required, including minor civil works like core cutting, MS stand / supports for AC units all as specified and / or directed etc.,complete.
Quoted price shall include cost of wireless remote controller, outdoor unit stand,cooling thermostat, wiring, control cabling and earthing. Unit shall be provided with auto clean mode, auto timer setting and as per specifications.) | 2 | Nos | - | - |
| 2.02 | Supply, erection, test & commissioning of refrigerant grade
(Supply, erection, testing and commissioning of refrigerant grade copper piping between indoor and outdoor units of suitable size (both suction and discharge piping will be treated as one unit and will not be measured separately),Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated with glass cloth of thickness as specified in DTS including pressure testing and charging of refrigerant and oil, joints, fittings, accessories, core cutting in brick/ concrete wall as required and making surface good, supports etc.suitable for upto 3.0 TR capacity Tower split AC unit) | 40 | Mtr | - | - |
| 2.03 | Providing & laying of cPVC (SDR11) 32MM dia
(Providing and laying of cPVC (SDR11) pipes of 32 mm dia, with 9 mm thick elastomeric nitrile rubber tubular insulation with factory laminated FRP cloth/ glass cloth for condensate water drain from the AC indoor units to nearest drain point, fittings, support including core cutting in brick/ concrete wall as required and making surface good with adhesive materials like silicon sealant etc. complete ) | 25 | Mtr | - | - |
| 2.04 | Providing & laying of cPVC (SDR11) 32MM
(Providing and laying of cPVC (SDR11) pipes of 32 mm dia for AC condensate water drain outside building with fittings, support including core cutting in brick/ concrete wall as required and making surface good etc. complete ) | 10 | Mtr | - | - |
| 2.05 | Supply of PVC mini trunking size 150mmX50mm
(Supply of PVC mini trunking profile/ system of size minimum 150mm X 50mm along with base, covers, endcaps, joints (coupler), bends, tees, mounting accessories etc. and installation of the same on the wall by providing required bolt-nuts/ screws with TW gutties/ fixing accessories as per manufacturers recommendation etc. complete as directed by Engineer in charge.) | 25 | Mtr | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.69 MB
TenderDocument.pdf
Tender Documents • 9.16 MB
BOQ_110244.xls
BOQ • 0.34 MB
DateCorrigendum-AC.pdf
PDF • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .