Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹14.2 L+₹10,589 (0.75%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹14.8 L+₹68,930.60 (4.90%)Rejected-AOC I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L3 | Rejected-AOC L3 | |
| 4 | L4₹14.9 L+₹82,890 (5.89%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹15.2 L+₹1.1 L (7.94%)Rejected-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹28,544
Closing Date
2 Dec 2020, 6:00 pmClosed
CWE JAMMU
CWE JAMMU 900172
PROVN OF HT UG CABLE FOR PUMP HOUSE AT MIL STN RATNUCHAK UNDER GE KALUCHAK
2020_MES_389371_1
CWE/JP-54/2020-21
Open Tender
Civil Works
Item Rate
180 days
CWE JAMMU
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE KALUCHAK
₹28,544
Yes
25 Jan 2021
23 Oct 2020
10 Dec 2020
23 Oct 2020
2 Dec 2020
15 Nov 2020
Amount
XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) with stranded aluminium conductor 11000 volts Earth grade, cross sectional area 95 Sqmm 3 Core laid in trench /poles/on wall all as specified and as directed by the Engineer in charge
Steel tubular swaged poles of type 410-SP-55 (11.0 mtr long) complete with CI base plate, finial taper plug, bolts, nuts ,screws and pole cap and inclusive of two coat of aluminium paint over a coat of red oxide primer including preparing the surface all as specified and as directed. ( Note:Excavation ,earth work and PCC shall be measured and paid separately )
Switch air break, gang operated, triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, having current rating upto 400 Amps for working pressure 11000 Volts with drop out type fuse assembly complete all as specified and as directed by the Engineer in charge.
Lightning arrestors expulsion type suitable for HT 11KV complete with all fitting,transmission class having discharge capacity 65Kilo Amp all as specified and as directed by the Engineer in charge.
Cross arms, bracings, supports clamps and back plates fabricated from structural steel sections incl. nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide primer including preparing the surface all as specified and as directed.
Pin type insulator , porcelain, vitreous white / brown including one galvanized mild steel spindle, two galvanized iron washers and one nut (galvanized iron) , for size of 150 mm height, 150 mm dia for 11000 volts grade insulator all as specified and as directed.
Disc type insulator(Single disc assembly) , porcelain, vitreous white / brown of size of 145 mm height, 255 mm dia ball and socket type for 11000 volts grade insulator all as specified and as directed.
Galvanized iron tubing 80mm bore light grade with all fitting laid in trenches/wall/floor/pole for protection of cable including providing fixing clamps, bolts and nuts of suitable size all as specified and as directed by the Engineer in charge. Note:Excavation ,earth work shall be measured and paid separately.
Cable jointing kit for 11 KV(Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95sqmm complete all as specified and as directed by the Engineer in charge.
Cable jointing kit for 11 KV(Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95sqmm complete all as specified and as directed by the Engineer in charge.
Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty ) 1100 volts(Earthed) grade with stranded aluminium conductor of size 70 Sqmm 3.5 core complete all as specified and as directed by the Engineer in charge.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for trench of cable/foundation of pole and stay etc and getting out in hard/dense soil soil complete all as specified and as directed by the Engineer in charge.
All as per Item No: 12 above but depth exceeding beyond 1.5mtr and not exc 3 metre all as specified and as directed by the Engineer in charge
Sand cushioning for protection of underground cable consolidated and compacted with clean dry sand all as specified and as directed by the Engineer in charge. Note: Compacted thickness shall only be measured and paid.
Bricks Sub class 'B' , best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed by the Engineer in charge
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and as directed by the Engineer in charge
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point all as specified and as directed by the Engineer in charge.
PCC ( 1:3:6 )Type C-2 (Using 40 mm graded stone aggregate as in foundation of pole, stay and filling and mass concrete) including providing necessary form work complete all as specified and as directed by the Engineer in charge
PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in copping of electric pole (set in cement mortar 1:4) at site including providing necessary form work complete all as specified and as directed by the Engineer in charge
Supply,installation,testing and commissioning distribution Transformer step down ,outdoor type ,11/0.433 KV complete with standard fittings HT 11KV 3 phase LT 433V,3 phase 4 wire with off load tappings on HT side to vary secondary voltage within limit with both side cable end box suitable for 95sqmm 3 core HT cable all as per IS: 2026 of capacity 63 KVA inclding Platform for installation of transformer of size 3.0 mx2.5 mx1.25 m including fencing and gate all as shown in drawing No CEPZ/TD-350/08 sheet 1/2 dated 14 Nov 2008 and CEPZ/TD-350/08 sheet 2/2 dated 14 Nov 2008 and as specified & directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32x6mm galvanised strip complete all as specified and as directed by the Engineer in charge.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc as required 20x3mm COPPER STRIP complete all as specified and as directed by the Engineer in charge.
Earthing complete with COPPER plate electrode of size 600x600x3.15 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to COPPER STRIP of size 20x3mm up to 7.5 mtr by means of nuts, bolts, check nuts, washers of tinned brass, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering,including charcoal or coke and salt in alternate layers and filling earth pit with fresh vegetable soil below copper plate and above upto ground level as required and necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed. Note:-Charges for earth resistivity test deemed to be included in the quoted rate. ii)Earth resistance value shall be less than 1.0ohm)
Material and Labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth STRIP 32X6MM THICK by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR PT-I including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, GI lugs, complete in all respect, GI earth wire protected by 40 mm bore (Light grade) galvanized iron pipe and other end connected with main switch board or earthing test point as directed including proper lugs, including disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete all as specified and as directed by the Engineer in charge . Note:1. Earthing Installation shall be done in the presence of Engineer in charge. 2. Earth resistance shall not exceed 1 ohm.
proach associates
SATISH AND CO
vishesh engineers
SUMEET TRADING CORPORATION
kailu construction co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .