| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹6.8 L+₹1.2 L (21.8%)Rejected-Finance 74 103 DHANKUTTI KANPUR 208001 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹6.9 L+₹1.3 L (23.3%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹7.0 L+₹1.4 L (24.9%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹7.4 L+₹1.8 L (32.4%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹21,600
Closing Date
28 Dec 2020, 6:00 pmClosed
GE I R and D Kanpur
GE I R and D Kanpur DMSRDE Complex, GT Road Kanpur 208013
REPAIR/REPLACEMENT OF WORN OUT SUB MAIN WIRING, TPN/SPN, DBS, EARTHING, SECURITY LIGHT FITTING, SUB MAIN WIRING, MODULAR TYPE ACCESSORIES ETC FOR TECHNICAL AREA UNDER GE (I) R and D KANPUR.
2020_MES_399098_1
8218/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE I R and D Kanpur
As Per NIT
8 documents required · 8 mandatory
₹500
GE I R and D Kanpur
₹21,600
Yes
15 Apr 2021
28 Nov 2020
30 Dec 2020
28 Nov 2020
28 Dec 2020
14 Dec 2020
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for point wiring complete with FR PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and including cutting/chasing on brick wall not exc. 10 cm girth (excluding ceiling surface for existing pipe) and supply and fixing concealed PVC conduit pipe medium grade of nominal size 20 mm dia along with connected fittings/junction boxes and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 3 mm thick Hylam brand sunmica laminated sheet cover with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed and suitable for the following: -
i) One light point or one fan point controlled by one way, single pole switch
(ii) One 3 pin socket outlet, 6 Amp on “independent board” but below the switch board of the light point in same vertical plane.
(iii) One 3 pin socket out let, 6 amps on the "same board" with other switches
(iv) One 3 pin socket outlet, 6 Amp on “independent board”
All as per item No. 2 here in above but point wiring using 2.5 Sqmm (Nominal area) FR PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on“independent board”.with 1.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete all as specified and directed.
.---do--- item No 3 but One 3/6 pin socket outlet, 6/16 Amp on “independent board” but below/side the switch board of the light point in same vertical plane complete all as specified and directed.
M&L fordrawing the wire in existing conduit steel/PVC complete with point wiring with FR PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 3 mm thick Hylam brand sunmica laminated sheet cover with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed and suitable for the following: -
i) One light point or one fan point controlled by one way, single pole switch
(ii) One 3 pin socket outlet, 6 Amp on “independent board” but below/side the switch board of the light point in same vertical plane.
(iii) One 3 pin socket out let, 6 amps on the "same board" with other switches
(iv) One 3 pin socket outlet, 6 Amp on “independent board”
All as per item No. 5 here in above but drawing in existing conduit for point wiring using 2.5 Sqmm (Nominal area) FR PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board”.with 1.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete. Make of wire: Havells/Polycab/Finolex
Supply only switch piano flush button type, 6 Amp one way, 240 Volt, single pole , ISI marked conforming to IS 3854 style double colour series with cover plate complete all as specified and directed. Make:- Anchor/havells/
Supply only switch piano flush button type, 6 Amp two way, 240 Volt, single pole , ISI marked conforming to IS 3854 style double colour series with cover plate complete all as specified and directed. Make:- Havells/ Anchor/
Supply only socket out let, 2 in 1, 5 pin, 6 Amp, 240 Volt AC, flush type, style double colour series with cover plate complete all as specified and directed. Make:- Anchor/havells/
Supply only switch socket combination multipurpose 5 in 1, 6 pin, 6 and 16 Amp, 240 Volt AC, style duoble colour series" with cover plate complete all as specified and directed. Make:- Anchor/havells/.
Supply only FASHION batten/angle holder with colour ring complete all as specified and directed. Make:- Anchor/havells/ .
Supply only FASHION ceiling rose with colour ring complete all as specified and directed. Make:- Anchor/havells .
Supply only medium step type fan regulator 80 Watt, 240 Volt AC, style double colour series "style medium step" ISI marked complete all as specified and directed. Make:- Anchor/havells.
Supply only in replacement of old unserviceable FTL fitting by LED light fitting trend wall mounted batten with extruded aluminum housing with intregated LEd driver with LED tube aluminum extrusion 18 watt complete. Make:- Crompton/ Philips/ Havells.
Supply only in replacement of old unserviceable Tube light by LED light tube rod for wall mounted batten with extruded aluminum housing with intregated LEd driver with LED tube aluminum extrusion 20 watt complete. Make:- Cat part : LT8-20-865(2) of Crompton/Philips
Supply only in replacement of old porch/balcony light by energy efficent LED 240 volt, AC Surfae mounted LED downlighter 12 watt, 5700CCT(K) in white colour including driver control etc complete all as directed at site. Make:- Philips/Havells/Bajaj
Supply only in replacement of Mirror optic fitting by recess/surface mounted mirror optic LED luminaire fitting with paralite P5 louvers, 5700 K, 36 watt LED dimention 2 ft x 2 ft fitting for grid type ceiling including control driver and other accessories complete all as specified and directed. Make:- Philips/Havells/Crompton.
Supply only in replacement of old inserviceable security light byenergy efficeant LED security light 240 volt AC 30 watt pressure die cast LED street light complete with 25mm dia Light grate GI pipe suitable size incl 3 core FR PVC insulated wire connection from Ceiling rose etc all as directed at site . Make:- Philips/Cromton Greaves/Bajaj.
Supply only in replacement of Kit Kat DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 complete all as specified and directed. Cat No. Schneider (Electric)/Legrand/L & T/Indoasian .
Supply & Fixing MCB TPN, 100 Amps 415 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make -Schneider Electric/L&T/Legrand/Indoasian.
Supply & Fixing MCB SPN, 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make -Schneider Electric/L&T/Legrand/Indoasian.
Supply only MCB SP, 06 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make -Schneider Electric/L&T/Legrand/Indoasian.
Supply only MCB TPN, 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make -Schneider Electric/L&T/Legrand/Indoasian.
Supply only MCB TP, 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make -Schneider Electric/L&T/Legrand/Indoasian.
Supply only in replacement of AC/Geyser box by sheet steel enclosure in single pole and neutral fitted with two pin and earth plug and socket complete with one single pole MCB, 240 volt, 20 Amps , 'C' series of suitable rating complete all as specified and directed . Make:- Schneider Electric/L&T/Legrand/Indoasian.
Supply only in replacement of Kit Kat DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way, confirming to IS 13032 & 8623 complete all as specified and directed. Make:- Schneider Electric/L&T/Legrand/Indoasian.
Supply & Fixing in replacement of Kit Kat DB by TPN Distribution Box vertical, double door of protection grade IP 43 provn for 4 Pole MCCB frame F2+24 modules upto 250 Amps , upto 50 KA breaking capacity as incomer in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 including chasing/cutting of wall and concealed and making good as existing surface complete all as specified and directed. Make -Schneider Electric/L&T/Legrand/Indoasian.
Supply and fixing in replacement of Kit Kat DB by TPN Distribution Box double door of protection grade IP 43, in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 including chasing/cutting of wall and concealed and making good as existing surface complete all as specified and directed. Make:- Schneider Electric/L&T/Legrand/Indoasian.
supply and fixing of MCCB 200 Amps 25 KA with fixed thermal magnetic release frame F2 optim 1.0 , 4pole all as specified and directed. Make:- Schneider Electric/L&T/Legrand/Indoasian.
S & F service connection with twin core 10 Sqmm 240 volt heavy duty un armured PVC insulated stranded aluminium conductor cable with GI supporting wire of suitable size in replacement of old unseriveable conductor cable complete. Make : Plaza /Poly cab/Havells/fenolex
S & F service connection with twin core 6 Sqmm 240 volt heavy duty un armured PVC insulated stranded aluminium conductor cable with GI supporting wire of suitable size in replacement of old unseriveable conductor cable complete. Make:- Plaza/Poly cab/Havells/fenolex
M&L in replacement of worn out sub main of worn out aluminium conductor by sub main wiring with four run of FR PVC insulated unsheathed flexible copper conductor (multistrands) single core of size 10.0 Sqmm 1100 volts grade and two run of 6.0 Sqmm FR PVC insulated unsheathed (in green colour) flexible copper conductor (multistrands) for continuous earthing conforming to IS 694 with latest amendments and ISI marked drawing in PVC rigid conduit and providing flexible conduit at each end point connecting incoming/out going electric connection by using required size copper lugs/thimbles and making good the disturbed surface to match with existing surface complete. Note :- 1. four run of single core cable with two run of contineous earth wire of copper conductor wire flexible (Multistrand) of FR PVC insulated shall be measured and paid as one unit length 2. PVC conduit pipe with fitting shall be measured and paid separately .
M&L in replacement of worn out sub main of worn out aluminium conductor by sub main wiring with four run of FR PVC insulated unsheathed flexible copper conductor (multistrands) single core of size 16.0 Sqmm 1100 volts grade and two run of 10.0 Sqmm FR PVC insulated unsheathed (in green colour) flexible copper conductor (multistrands) for continuous earthing conforming to IS 694 with latest amendments and ISI marked drawing in PVC rigid conduit and providing flexible conduit at each end point connecting incoming/out going electric connection by using required size copper lugs/thimbles and making good the disturbed surface to match with existing surface complete. Note :- 1. four run of single core cable with two run of contineous earth wire of copper conductor wire flexible (Multistrand) of FR PVC insulated shall be measured and paid as one unit length 2. PVC conduit pipe with fitting shall be measured and paid separately .
Supplied and fixing in replacement PVC conduit by Non Metallic Rigid PVC conduit, ISI Marked, conforming to IS 9537, medium grade of size 32 mm dia including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles, pipe hooks etc complete all as specified and directed.
M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 4.0 Sqmm, 1100 Volts grade and one run of 2.5 Sqmm FR PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and including draw in PVC rigid conduit 25 mm dia , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing colour (distumber, Oil bound, Samosem etc ) complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire flexible (Multistrand) of FR PVC insulated shall be measured and paid as one unit length 2. PVC conduit pipe with fitting shall be measured and paid separately .
M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.0 Sqmm, 1100 Volts grade and one run of 4.00 Sqmm FR PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and drawing in PVC rigid conduit , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FR PVC insulated shall be measured and paid as one unit length. 2. PVC conduit pipe with fitting shall be measured and paid separately .
Supplied and fixing in replacement PVC conduit by Non Metallic Rigid PVC conduit, ISI Marked, conforming to IS 9537, medium grade of size 25 mm dia including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including Cutting & Chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and distemper / colour wash etc to match with existing surfaces including facing / finishing complete all as specified and directed.
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately).
Attending the complaints lodged by the occupants/users of electrification nature & rectification of the fault as per the complaint lodged by the user onward OH line LT/HT lines in any time (day/Night) in respect of main fixture /breakdown for light/fan/bell/light or power socket and LT/HT OH line etc complete repairs to the extent by removing connections from the system removing faults in wires, battens, conduit, sunken boxes, junction boxes, main switches, MCBs/DBs utility light fitting, lamp holders AC ceiling/ Exhaust fans and other type of complaints to connected fixtures of the internal electrification including providing of petty stores such as wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tape, screws , nuts as required to rectified the fault with regard to the complaint lodged and refixing of fittings, fixtures to their position as dismantled and respect of item if required to be paid under respective item as required complete all as directed at site to th entire satisfaction of Engr-in-Charge/users. Note for Srl No -01 :- (a) No light ,breakdown, repair/ replacement of switches, fan, regulator , replacing burnt/ damaged wiring , replacement of burnt MCBs and main switch , voltage fluctuation, current leakage, replacement of HT DOs/fuse, repair of street lights, repair of OH line, OH conductor and replacement of tube lights etc will be attended with in 8 Hrs as urgent nature. (b) Any LT breakdown complaints will be attended by skilled electricians/ Helpers as required at site without any delay & any time (day/Night).
(c ) The complaints will be attended by electricians & respective helpers in each day & night without any delay. (d) The complaint will be taken from complaint cell of RV sustation in technial area . The rates are included for complaints for T&GS Building, Material building , Technical Library, Wet Canteen, P-29 Building, P-30 Building,P-31 Building, P 14 , P-47 Buidling, MT area and other coneected Buidling in Tech area. (e) All necessary tools & plants i.e. multimeter, tong tester, spanner set, wrench, screw driver set, combination plier, testing lamp set, drilling machine, bamboo ladder, blower/ vaccum cleaner, crimping tool, cutting and chasing tool, insulation megger , etc will have to kept by each tradesman engaged by contractor at his own cost. (f) Any accident/ mishappening occurred during the execution of work shall be responsibility of Contractor. (g) One MOBILE PHONE should also be provided by contractor to the each trademan engaged by him with incoming & out going facilities for normal and after working hours also so as to contact him in case of emergency during the entire period covered under the contract to keep liaison / communication with MES staff . (h) complaint register and complaint slip shall be providing by the contractor duly printed with CA No and firm and the cost is deemed to be included in unit rate (j ) Cost of material and labour for replacement of new items shall be measured and paid separately under relevant items of Sch A. Against supply only here-in-after .
Himanshu Construction and Suppliers
SAKSHAM SUPPLIERS BUILDERS
M/s A S Electrical
VEE KAY ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .