Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹94.8 L+₹16.4 L (20.9%)Rejected-Finance HOUSE NO 707 SECTOR 11 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | 134109 | L2 | Rejected-Finance HIGHER | |
| 3 | L3₹1.0 Cr+₹24.5 L (31.2%)Rejected-Finance 3077 SECTOR 28 D CHANDIGARH | L3 | Rejected-Finance HIGHER | |
| 4 | Rejected-Technical 34 225 KALKA GARIDAN PINJORE PANCHKULA HARYANA 134102 | PANCHKULA | HARYANA | 134102 | - | Rejected-Technical NON-RESPONSIVE | |
| 5 | Rejected-Technical BHARAULI VILL BHARAULI AMBALA HARYANA | BHARAULI | AMBALA | HARYANA | 134204 | - | Rejected-Technical NON-RESPONSIVE |
Tender Value
₹96.2 L
EMD Value
₹1.9 L
Closing Date
3 Mar 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Gaurav Jain, EE
Executive Engineer, Provincial Division, PWD B and R Br., Panchkula
Widening and Strengthening and Hard Shouldering of Raipur Rani-Tirlokpur road RD 10.600 to 10.950 Km in Panchkula District. (Road ID 2775).
2022_HRY_208035_1
PWD/CHD/PKL/1254
Open Tender
Construction Works
Works
120 days
Panchkula
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹1.9 L
Yes
30 May 2022
12 Feb 2022
4 Mar 2022
12 Feb 2022
3 Mar 2022
12 Feb 2022
120 days
Amount
Excavation for road work in soil by mechanical means including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including breaking of clods and disposal within ROWs as per technical clause 301 of MORT&H specifications. (HSR 17.74)
Providing & laying WBM (G-I) 63 to 45mm with screening of Type ‘A’ in layer of 75mm each, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications (Based on HSR 17.22.2) Note: - 1.Only crushed metal material should be used. No local earth sand shall be used. The material finer than 425 micron shall have zero Plasticity Index (PI). 2. Materials to be used and operations of manufacturing shall be approved by the engineer.
Providing, laying WBM (G-II) 53 mm to 22.4 mm with screening of Type ‘A’ in layer of 75mm each, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications (Based on HSR 17.23.2) Note: - 1.Only crushed metal material should be used. No local earth sand shall be used. The material finer than 425 micron shall have zero Plasticity Index (PI). 2. Materials to be used and operations of manufacturing shall be approved by the engineer
Earth work in excavation in all kind of soil by mechanical means Hydraulic excavator in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to any, including getting out the excavated soil and disposal of surplus excavated soil as directed by Engineer-in-charge, within any lead. (HSR 4.14.1)
Providing and laying in position cement concrete 1:2:4 of specified grade with stone aggregate 20mm nominal size excluding the cost of centering and shuttering complete in all respect (HSR.6.1.2).
Providing and laying in position cement concrete of specified grade 1:4:8 with stone aggregate 40 mm nominal size excluding the cost of centering and shuttering, complete in all respect. (HSR.6.1.6)
Providing and laying in position specified grade of reinforced cement concrete, 1:1½:3 with stone aggregate 20mm nominal size excluding the cost of centering, shuttering, finishing and reinforcement. (HSR 6.14.1)
Reinforced cement concrete 1:1½:3 with stone aggregate 20mm nominal size work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement. (HSR 6.15.1)
Centering and shuttering including strutting, propping etc. and removal of form work for retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. (HSR 6.29.2)
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform (HSR 6.30.3)
Steel reinforcement Thermo-Mechanically Treated bars of grade Fe-500D or more for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level. Note: - Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 6.33.6)
Brick work with common burnt clay non modular bricks of class designation 10.5 in foundation and plinth in cement Mortar 1:4. (HSR 7.21.1)
Providing and laying dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. (HSR 10.34)
Painting the wooden / metal surface with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work (HSR 11.82.1)
Providing and Laying 80 mm thick ISI marked Interlocking Paver Blocks conforming to IS 15658:2006/IRC SP 63: 2004 of all shapes and colours in design mix cement M 40 over the bed of 30 mm thick fine sand complete in all respect. (HSR 17.69.2)
Construction of embankment (on berms) with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications.
Providing and laying of cement concrete blocks of size 0.450 m x0.300 m x 0.15 m of cement concrete (C.C) M30 grade and spreading 25 mm thick sand underneath filling joints with sand on existing W.B.M./G.S.B base as per technical specification clause 1503 (HSR.17.66.1)
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1 V:20H towards drawing force. Complete as per drawing and MoRT&H Specifications (HSR.27.15)
Providing and laying of Filter media with granular 710.1.4.of materials/stone crushed aggregates satisfying IRC:78 and the requirements laid down in clause of MoRT H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and MoRT&H Specification (HSR.27.17)
Providing & fixing cautionary sign board 900x900x900mm triangular as per IRC 67- 2012 with using retro reflective Sheeting Class C as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports including three year outdoor weathering test report for sheeting tested in India condition from an independent test laboratory conforming to clause 6.7 of IRC67-2012 (HSR.34.4.1)
Providing & fixing advance direction sign board 900x900mm square as per IRC 67- 2012 with using retro reflective Sheeting Class C, as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4 mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause6.7 of IRC 67-2012 (HSR.34.12.1)
Providing & fixing advance Direction signboard 1200x900mm square as per IRC 67- 2012 with using retro reflective Sheeting Class C as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4 mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORT&H specifications.Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67-2012 (HSR.34.13.1)
Providing & fixing Hazard Marker sign board 300x900mm rectangular as per IRC 67- 2012 with using retro reflective Sheeting Class C as per ASTM D 4956 09 and IRC 67 2012, fixed over 4mm thick Aluminium Composite Material (ACM) sheeting having skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground including foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67- 2012. (HSR.34.19.1)
Providing and erecting a 'W' metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be f1Xed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 (HSR.34.32.1)
Note:- 1. In case of any difference in the unit of any of the HSR/DSR Items of Civil, P.H. & E.I. work depicted in this DNIT and that given in HSR/DSR, the unit given in HSR/ DSR shall be applicable. 2. Only reputed make material will be used (make/brand exhibited in HSR/DSR and exhibited in approved standard document) as approved by Engineer-in-charge, while executing various items/works at site. Notes:- 1. The item for which no rate or price has been entered in will not be paid for by the Employer when executed and shall be deemed to be covered by the other rates and prices in the Bill of Quantities (Refer: ITB Clause 13.2 and Part I General Condition of Contract 39.3). 2. Unit rates and prices shall be quoted by the bidder in Indian rupees [ITB Clause 14.1]. 3. Deleted.
Sukhvinder Singh
AGGARWAL CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .