Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 LAccepted-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being lowest and competitive | |
| 2 | L2₹35.9 L+₹17,644.50 (0.49%)Rejected-AOC | L2 | Rejected-AOC Neither lowest nor competitive | |
| 3 | L3₹38.7 L+₹2.9 L (8.21%)Rejected-AOC | L3 | Rejected-AOC Neither lowest nor competitive | |
| 4 | L4₹39.6 L+₹3.9 L (10.8%)Rejected-AOC E 30 RAJIV NAGAR BEGAMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L4 | Rejected-AOC Neither lowest nor competitive |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
26 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Delhi Cantt
GE (Central) Delhi Cantt
PROVN OF CERTAIN SANCTION WORKS IN THE AREA OF AGE B/R-II AND AGE E/M UNDER GE (CENTRAL) DELHI CANTT-10
2020_MES_373942_2
GE/C-44/2020-21
Open Tender
Civil Works
Item Rate
GE (Central) Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹500
GE (Central) Delhi Cantt
₹98,000
Yes
11 Nov 2020
6 Oct 2020
28 Oct 2020
6 Oct 2020
26 Oct 2020
14 Oct 2020
6 Oct 2020 - 14 Oct 2020
60 days
Amount
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar, complerte all specified and directed by Engineer-in-Charge.
M & L for non skid 600x600x08 to 09mm thick coloured rectified ceramic tiles as in floor laid over and including 15mm thick screed bed in CM 1:6, including pointing in coloured cement to match the shade of tiles including hacking out the existing floor surface,cleaning with water and applying cement slurry @ 3 kg/sqm on prepared surface of floor and including cutting/adjusting of existing door shutter at required height after taking down and refixing complete all as specified directed by Engr-in-Charge. Make-kajaria/Somany/Orient
All as per item No 2 above but laid over and including 10mm thick on rendering surface in CM 1:4 on vertical surfaces of wall as in skirting including taking down of existing skirting/dado with screed/plaster on walls complete all as specified directed by Engr-in-Charge.Make - kajaria /Somany/Orient
M & L for 600x600x08 to 09mm thick coloured (light shade) vitrified tiles(joint less) as in floor laid over and including 15mm thick screed bed in CM 1:6, including pointing in coloured cement to match the shade of tiles including hacking out the existing floor surface,cleaning with water and applying cement slurry @ 3 kg/sqm on prepared surface of floor and including cutting/adjusting of existing door shutter at required height after taking down and refixing complete all as specified directed by Engr-in-Charge, make of tiles as approved by GE. Make-kajaria/Somany/Orient
All as per item No 4 above but laid over and including 10mm thick on rendering surface in CM 1:4 on vertical surfaces of wall as in skirting including taking down of existing skirting/dado with screed/plaster on walls complete all as specified directed by Engr-in-Charge.Make - kajaria /Somany/Orient
M& L for non skid coloured rectified ceramic tiles (300x300x)7 to 8mm thick in floors, etc, set and jointed in neat cement slurry and pointed in coloured cement to match laid over and including 15mm thick screed bed for laying floor in CM 1:6 including dismantling the existing tiles with screed and removal of debries out of MOD Land complete all as specified and directed by Engineer in Charge, approved by GE Make - kajaria /Somany/Orient
M&L for coloured ceramic tiles (300x600mm)x7mm or thick on vertical surfaces on skirting /dados and risers to steps etc laid over and including rendering 10mm thick cement mortar in CM 1:4 ,including dismantling the existing tiles with screed and removal of debries out of MOD Land complete all as specified and directed by Engr-in-Charge, approved by GE Make-kajaria/Somany/Orient
Taking up or down 15 mm dia GI tubing and connections including cleaning for re-fixing incl scafolding etc, complete all as specified and directed by Engineer in Charge,
S&F 15mm dia GI tubing medium grade with all fitting and fixed to wall and ceiling or laid in floors etc incl scafolding, cutting chases in wall where ever required etc complete all as specified and directed by Engineer in Charge,.
S&F in repair vitreous China coloured European type WC with "P" or "S" trap 1st quality including connection to drain and fixing bolts,and providing plastic water closet seat cover complete all as specified and directed by Engineer in Charge,
S&F in repair 10 ltrs capacity PVC colour low level flushing cistern with PVC flush pipe 32mm dia complete all as specified and directed by Engineer in Charge,.Make : Hindware/Parryware/CERA
S & F Brass CP health faucet of 15mm dia incl extension pipe not less than 1.5 mtr long screwecd for iron pipe fancy type long body complete all as specified and directed by Engineer in Charge,. Make : Jaquar/MARC
S&F in repair brass chromium plated toilet paper holder, complete all as specified and directed by Engineer in Charge, Make : Jaquar/MARC
Supply & fix in repair PVC connection pipe of 1/2"x18" size with 2 Nos brass check nuts with washers, complete all as specified.Make : prayag
S&F in repairs vitreous chinaware wash hand basin, with padestal white, flat back of size 580mm x 400mm including CP Waste coupling ,waste pipe ,complete fixing arrangement and cutting for and pinning in walls & making good complete all as specifed and directed by Eng in charge.Make : Hindware/ Parryware/CERA
S&F in repair 15mm dia brass chromium plated mixer for mixing hot and cold water screwed down for iron pipe and fixed to WHB including taking out existing mixer from old WHB, complete all as specified and directed by Engineer in Charge,.Make : Jaquar/MARC
S&F in repair brass chromium plated soap dish, complete all as specified and directed by Engineer in Charge,.Make : Jaquar/MARC
S&F in repair 600mmx450mm bevelled edge mirror of slected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screw and cupwashers, complete all as specified and directed by Engineer in Charge,
S&F in repair CP grating 125mm dia, complete all as specified and directed by Engineer in Charge,
S&F in repair chromium plated brass angle valve dual type (two in one) suitable for 15mm bore pipe complete all as specified and directed by Engineer in Charge,.Make : Jaquar/MARC
S&F in repair 15mm dia chromium plated brass wall mixer hot & cold L bend 3 in 1 pattern fixing and connection to pipes complete all as directed.Make : Jaquar/MARC
S&F in repair 15mm dia chromium plated brass fancy type wall mixer hot & cold with long swan for kitchen sink fixing and connection to pipes complete all as specified and directed by Engineer in Charge,.Make : Jaquar/MARC
S&F in repair chromium plated brass angle valve type suitable for 15mm bore pipe complete all as specified and directed by Engineer in Charge,.Make : Jaquar/MARC
S & Fixed in repair 125mm size brass CP shower rose complete all as specified and directed by Engineer in Charge,..Make : Jaquar/MARC
S&F stainless steel of AE - SI 316 grade tubular towel ring including apair of CP brass bracket complete all as specified and directed by Engineer in Charge, . .Make : Jaquar/MARC
S&F in repairs bib tap brass with crutch or butterfly handle, screwed down, screwed for iron pipe, 15mm dia, fancy type, cast copper alloy, chromium plated long body with flange complete all as specified and directed by Engineer in Charge, Make : Jaquar/MARC
S&F stainless steel towel rack size 600mmX 300mm including apair of brass bracket complete all as specified &directed by Engr in charge.
Taking down cement plaster, terrazzo dado in any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish,vegitation outside complex (MOD land), complete all as specified and directed by Engineer in Charge,
M & L for 10 mm thick internal rendering in cement mortar 1:6 on fair face of brick walls/ concrete surfaces & finished even and smooth without using extra cement, complete all as specified and directed by Engineer in Charge,
M&L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of oil bound distemper(white or tinted) over a coat of chalk whitening or 2-3 mm thick whitning wall putty on plastered surfaces, complete all as specified and directed by Engineer in Charge,
S & F in repair Stainless steel drapery Rod 20 mm of dia ,with bracket including including premium balls complete incl taking down old pelmet box all as approved by Engineer-in-charge
Taking down chowkats or frames exc. 1.5 Sqm and n.exc 4 Sqm each with shutters (without taking off shutters from frames ), complete all as specified and directed by Engineer in Charge,
S&F powder coated aluminum frames for door, windows/ventilators with one or more rebates including jointing cleats for fixing etc including alu grillcomplete all as specified and directed by Engineer in Charge,
S&F powder coated aluminum door, window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.),hinges type B-21 100mm long (2no.) suitable handle ,(01 no.) complete all as specified and directed by Engineer in Charge,
S&F 4.00 mm thick plain sheet glass and glazing with oil putty in square n.exc 0.5 Sqm in each pane, complete all as specified and directed by Engineer in Charge,
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with steel wire staples, complete all as specified and directed by Engineer in Charge,
M & L for 16-18 mm thick Black Granite stone work (table rubbed and polished) over and including15mm thick Screed bed or bedding layer in CM 1:4, as in steps, jambs, pillars, window cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite,front and side of slab moulded and polished including dismantling the existing stone slab with screed/ backing and removal of debries out side the MOD Land complete all as specified and as directed by the Engineer-in-Charge.Note- The cost of making hole for Gas pipe in cooking plateform is included in unit cost of item and nothing extra shall be paid on this account complete all as specified and directed by Engineer in Charge,.
Taking down chowkats or frames n.exc 1.5 sqm each with shutters (without taking off shutters from frames), complete all as specified and directed by Engineer in Charge,
S&F powder coated 50 micron thick aluminium sliding window three track, two shutter SERIES-B (SHUTTER SECTION-18mm) with two glazed shutters each covering half opening and one gauged shutter covering half opening including self closing locking arrangement, stoppers and rubber beading gasket without sash bar aluminum section weighing 0.55 Kg per mtr including necessary jointing cleats glazing clips rubber packing powder coated aluminum beading screws including fittings in each shutter along with provision of opening for window AC complete all as specified and directed by Engineer in Charge,
S&F 4.00 mm thick tinted glass panes as per instructions of manufacturers PVC beading, aluminium beads, complete all as specified and directed by Engineer in Charge,
S&F 12mm thickness Prelaminated particle board,interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed by Engineer in Charge,
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1 : 4 finished even and smooth without using extra cement complete all as specified and directed by Engineer in Charge,
M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing concealed in wall & drawn through and including rigid PVC conduit FRLS, medium grade ,ISI marked ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover for terminal boxes also including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly the following :
One light/fan point controlled by one by one way switch ( switch to be measured and paid separtely)
One 5 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable as earth wire connected to common earth and to earth dully socket & switches to be measured and paid separately.
All as above item No 43.02 but Same board.
Poin t wiring with insulated stranded copper conductor cable 4 Sqmm single core and PVC insulated FRLS 1100 Volts unsheathed copper conductor 4 Sqmm stranded conductor as earth wire connected to dolly drwan through and incuding 20mm dia rigid PVC conduit complete (socket and switches to be measured and paid separately) complete all as specified and directed by Engineer in Charge,
M&L angle Lamp holder with metallic ring, PVC/Polycorbonate type with back plate complete all as specified and directed by Engineer in Charge,
S & F LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in Charge,
M&L switch Piano flush type 5 Amp SP one way all as specified and directed by Engr in Charge.
M&L switch piano flush type 15 Amp SP one way all as specified and directed by Engr in Charge.
M&L socket outlet 5 pin 5 Amp flush type all as specified and directed by Engr in Charge.
M&L socket outlet 2 in 1,3 pin 5/15 Amps all as specified and directed by Engr in Charge.
S & F water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection complete all as specified of capacity 25 ltr and not less than 5 star rating and having 1.5 KW element.
M & L for cutting the existing GI tube pipe for insertation of new Tee branches, reducers in any position of 15 mm dia pipe line complete all as specified and directed by Engineer in Charge,
S&F tubes, 'medium grade', galvanised, with all fitting; laid in trenches, fixing on wall complete of bore 15mm dia complete all as specified and directed by Engineer in Charge,
S&F of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 15mm dia complete all as specified and directed by Engineer in Charge,
S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of cap 15mm dia complete all as specified and directed by Engineer in Charge,
M&L MCB SPN 32 Amp "C " curve complete all as specified and directed by Engineer in Charge, .
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed by Engineer in Charge,
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed by Engineer in Charge,
Supply and fix 10/12 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix in repair MCCB 100 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in Charge, .
Supply and fixing in repair exhaust fan 300 mm sweep (Metal type ) with louver including connecting with suitable size of copper conductor from ceiling rose to fan complete and making suitbale size, hole, for fixing etc all as specified and directed by Engineer in Charge.
Dismantling and taking out old unserviceable LT panel of any type and shape after breaking of PCC foundation/platform and taking away from exisiting location after necessary disconnection of all out going and incomming cable joints, earth strips etc. complete all as specified and directed by Engr-in-Charge.
Supply,installation,testing,commissioning of CPRI approved LT Panel of size 1700x1300x300 mm cubical compartmentalized, indoor type floor mounted suitable for 415 Volt 3 phase 4 wire 50 Hz, AC supply system having bus bar chamber with duly insulated copper bus bar of rating 400 amps mounted on epoxy/SMC type insulator. The Panel shall be dust and vermin proof IP 42 class protection and made out of 2.00 mm thick CRCA sheet, powder coated finish outside,front openable type hinged door with locking arrangement internal wirig with PVC insulated flexible copper conductor with the following incoming and outgoing feeders including the writting of qtr Nos on LT Panels.The Panel shall be embedded with 50 x 6 mm MS Angle Iron frame and 45 cm above the normal ground level complete with PCC foundation (1:2:4 ) type B2 complete and cleaning of the cable duct and all as specified and directed by Engr in charge and comprising of the following.
M&L earthing complete with GI electrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.50 mtr below normal ground level connected to GI strip 32x6mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of alternate layer of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MS angle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia GI pipe Medium grade for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. Note:- Galvanised strip and protection light grade GI pipe upto 7.5 mtr shall be deemed to be in the rates.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 32x6 mm thick galvanised strip with duly fixed on suitable size of porcelain/ PVC insulator complete all as specified. and as directed by Engr-in-Charge.
S&F Synthetic insulating mat 2mx1mx12mm, for indoor LT Panel protection, complete all as specifeid and as directed by Engr in Charge.
S&F sheet metal enclosure one way for independent mounting of 4 Pole MCCB, Including MCCB 4 Pole 250 Amps 25 KA, 415 Volts complete all as specified and as directed by Engr-in-Charge.
Supply and lay XLPE insulated PVC bedded galvanised steel strip or wire armoured electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core including connection of cable at both ends with suitable size of glands, aluminum lugs complete jointing, testing and commissioning complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB DB SPN 8 way, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as specified and as directed by Engr-in-Charge..
S&F in replacement of MCB DP 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of MCB SP 6 - 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and as directed by Engr-in-Charge.
M & L Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls all as specified and as directed. Note:- (1) Two runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as unit length. (2) The damaged surfaces to be made good with plastering will be carried out by contractor and cost of the same deem to be included in the quoted rates. Nothing extra in this account will be admissible complete all as specified and directed by Engineer in Charge,.
M & L Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls all as specified and as directed. Note:- (1) Two runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as unit length. (2) The damaged surfaces to be made good with plastering will be carried out by contractor and cost of the same deem to be included in the quoted rates. Nothing extra in this account will be admissible complete all as specified and directed by Engineer in Charge,.
M&L for disconnecting all the cable connection from indoor LT Panel and servicing to Panel board (Approximate size 1700mm x1300mm x 300mm) opening up all cubical doors, cleaning with air blower, removing the burnt out unserviceable copper wiring kit and burn out unserviceable extended copper terminals/copper cable and replacing with new copper extended terminal bus bar with suitable size along with required nut bolt, washers and cleaning with air blower to serviceable parts like MCCB's, all terminals, replacement of damaged aluminium/copper lugs any discription of LT UG cable/ copper wire incomming and out going, welding of broken door with suitable hinges, replacement of defective copper wiring with suitable copper conductor with circuit indiator replacement of defective rubber beading including preparing the existing surface for spray painting to powder coated surface with two coat of synthetic enamel paint approved colour including writing various feeder including clean the cable duct as well as the LT Panel room complete all as specified and as directed by Engr-in-Charge.
Taking down carefully copper/aluminium point wiring (light/fan/ socket/power) complete from the wall by cutting/ chasing including fittings and fixtures such as switches, ceiling roses, pendants holder, regulators,sockets,light fittings etc for credit and making good the disturbed surfaces of wall, floor etc complete all as specified and directed by Engr-in-Charge.
M & L for Point wiring with PVC unsheathed multi stranded copper conductor cable 1.5 sqmm (nominal dia ) 1100 volts in existing PVC concealed conduit and new MS steel terminal boxes not less than 1.6 mm thick of required size (factory made) terminal boxes and with top cover of 3 mm thick hylam sheet of white colour including one run of 1.5 SQMM FRLS 1100 Volts copper conductor cable (green colour) as earth continuity connected to common earth for one light point complete all as specified and directed by Engr-in-Charge.
One light /Ceiling fan/exhaust fan/ bell point controlled by one switch.
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on Ind board
All as per item No.77 herein before but with 4.0 sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4.0 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified and directed by Engr - in- charge. Note for Item 78 to 80 : (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC casing/caping to avoid any damage to the RCC portion. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above.
M&L for point wiring with 2 single core PVC insulated, unsheathed stranded copper conductor of size 4 sqmm and including one single core of size 4 Sqmm as Earth continuty conductor and PVC casing/caping 20mm dia medium grade and PVC board for mounting switches/socket combination all as specified and directed by Engr - in- charge.
Supply & Fix fan regulator electronic step type 5 steps piano type, one module connecting complete.
S&F ceiling rose, PVC/polycabinated, isolated body with three terminals complete all as specified and directed by Engineer in Charge,
Supply and fix surface ceiling mounted, round LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed by Engineer in Charge,
M & L Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls all as specified and as directed. Note:- (1) Two runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as unit length. (2) The damaged surfaces to be made good with plastering will be carried out by contractor and cost of the same deem to be included in the quoted rates. Nothing extra in this account will be admissible complete all as specified and directed by Engineer in Charge,.
S & F in repair sheet metal enclosure single pole and Neutral with a two pin earth plug top and socket complete with a MCB SP 20 Amp, "C" Curve 220 volts, 50 Hz, 10KA breaking capacity complete all as specified and directed by Engr-in-Charge.
Taking down old MCCB , TPN DBs , SPN DBs, & main switch/ enclosure box of any make and type from the site and making good the disturbed surfaces complete all as specified and directed by Engineer in Charge,
Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed by Engineer in Charge,
S&F on load change over switch with sheet metal enclosures 415 Volts, 320 Amps, 3 Phase with neutral link complete with lugs, thimble, cement works etc Make :-Standard/ Havells/ Legrand.
Supply & fix in repair factory made epoxy powder coated Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623 complete all as specified and directed by Engineer in Charge,
M&L in replacement MCCB 125 Amps, 16 KA , 4P,complete all as specified and directed by Engineer in Charge,
S&F MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as specified and directed by Engineer in Charge,
S&F MCB SPN 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in Charge,
M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to earth lead GI 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 5 connected to earthing test point earth plate surrounding use of charcoal dust and salt in layer including excavation and earth work , GI pipe 20 mm dia light grade for watering with wire mess and funnel and GI pipe 15 mm dia medium grade for protection of earth lead complete upto main TPN DB making of PCC earth pit using 1:2:4 type B1 using 20mm dia stone aggregate provision of MS PIT cover 300mm x300mm with handle complete all as specified or indicated including testing on complete all as specified and directed by Engineer in Charge,
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc 4 mm dia galvanised or steel wire complete all as specified and directed by Engineer in Charge,
M&L for earthing of machinery/equipment/panel/installed at power house/subatation, complete with galvanised steel earth palte electrode 600 x 600 x 6 mm thick buried directly in ground (Earth pit not less than 2.5 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to galvanised iron strip 25 x 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth protected by 40 mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electrical plate No.3 of SSR Part-I )2009) and testing on completion all as specified and directed.
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 25x4 mm thick galvanised strip duly fixed on suitable size of porcelain/ PVC insulator complete all as specified and directed.
Taking down ceiling light/wall mounting light of any make and type from the site after disconnecting electrical connection and refixing the same on site complete all as specified and directed by Engr-in-charge.
M&L switch Modular type 6 Amps one way 230V AC complete all as specified and directed by Engineer in Charge,
M&L switch Modular type 16 Amps one way 230V AC complete all as specified and directed by Engineer in Charge,
M&L Modular socket outlet 5 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in Charge,
M&L Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in Charge,
Supply & Fix Modular five stepped type electronic fan regulator 2 module 230V AC complete all as specified and directed by Engineer in Charge,
supply and fix recessed mounting LED FLAT panel 2"x2" made of crca sheet aluminium duly power coated with high efficient LED and glaire free full opal diffuser , IP 20 Suitable for 36 watt,230 volts ,50 Hz AC Supply, Neutral White,with electronic driver and incluiding all fixing accessories complete all as specified and directed by Engineer in Charge,
Supply and fix in LED surface/ceiling mounted round down light PC housing suitable for 18 watt ,230 volts ,50 Hz AC Supply incluiding all fixing accessories complete all as specified and directed by Engineer in Charge,make -Jaquar OR equivelent of bajaj/Philips
for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid new PVC conduit medium grade 20 mm dia, ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:-
One light /Ceiling fan/exhaust fan point controlled by one, one way switch
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
All as per item No.106 herein before but with 4 sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified and directed Note for Item 106&107 : (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC conduit to avoid any damage to the RCC portion. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above. (iii) Proper colour code will be used for wiring as per the electrical rule and as directed by EIC.
“M&L for Sub main wiring complete with FRLS PVC insulated unsheathed stranded copper conductor wire 4 Sq mm two runs (for Phase & Neutral) along with earth wire FRLS PVC insulated unsheathed stranded copper conductor wire of size 4 sq mm wire drawn through in & including PVC conduit 20 mm dia medium grade ISI marked including all fitting accessories concealed in wallcomplete all as specified and as directed Note:- (i) Two runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as unit length. (ii) The damaged surfaces to be made good with plastering will be carried out by contractor and cost of the same deem to be included in the quoted rates. Nothing extra in this account will be admissible (iii) In case the wiring is encountered with any beam/column/Ceiling then the wiring will run on surface PVC conduit to avoid any damage to the RCC portion
“M&L for Sub main wiring complete with FRLS PVC insulated unsheathed stranded copper conductor wire 6 Sq mm two runs (for Phase & Neutral) along with earth wire FRLS PVC insulated unsheathed stranded copper conductor wire of size 6 sq mm wire drawn through in & including PVC conduit 20 mm dia medium grade ISI marked including all fitting accessories concealed in wall complete all as specified and as directed. Note:- (i) Two runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as unit length. (ii) The damaged surfaces to be made good with plastering will be carried out by contractor and cost of the same deem to be included in the quoted rates. Nothing extra in this account will be admissible. (iii) In case the wiring is encountered with any beam/column/Ceiling then the wiring will run on surface PVC conduit to avoid any damage to the RCC portion
Note :- Total amount of Sch of credit is Rs. 41978.00 as per Sch of credit. Net contract sum shall be total quoted amount of bidder (-) amount of Sch of credit.
PARKASH ENTERPRISES
Pall Associates
GIAN ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .