Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹28.9 L+₹59,179.40 (2.09%)Rejected-Finance OFFICE 4 9 SWARG ASHRAM NANAK RAM COLONY PARMANAND CHOWK DELHI 110009 | DELHI | DELHI | DELHI | 110009 | L2 | Rejected-Finance Other than L1 Bidder | |
| 3 | L3₹29.4 L+₹1.1 L (3.85%)Rejected-Finance | L3 | Rejected-Finance Other than L1 Bidder | |
| 4 | L4₹31.2 L+₹2.9 L (10.3%)Rejected-Finance | L4 | Rejected-Finance Other than L1 Bidder | |
| 5 | L5₹31.3 L+₹3.0 L (10.7%)Rejected-Finance NARMADA COLONY BARADARI CHOURAHA MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L5 | Rejected-Finance Other than L1 Bidder |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
9 Jan 2023, 6:00 pmClosed
Garrison Engineer Gwalior
Garrison Engineer Morar Cantt Gwalior
8810/GWL/E8 SPECIAL REPAIR OF BATHROOM AT BLDG NO P-125 AND P-126 INCL CERTAIN MINOR WORKS UNDER AGE B/R-I AT MORAR CANTT GWALIOR
2022_MES_569202_1
8810/GWL/E8
Open Tender
Miscellaneous Works
Works
180 days
Garrison Engineer Gwalior
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer Gwalior
₹89,000
Yes
13 Feb 2023
15 Dec 2022
12 Jan 2023
15 Dec 2022
9 Jan 2023
2 Jan 2023
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out etc as in any type of soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed.
M&L for 150 mm dia internal bore Salt-glazed stoneware drain pipes laid in trenches and jointed complete all as specified specified and directed.
M&L for cement concrete bed 1:4:8 type D2 to 150 mm dia drain pipes including forming cradles; in complete all as specified and directed.
Demolition of cement concrete of any description and in any position (unreinforced) in ground floors and paving not exceeding 15 cm thick (below or above GL) complete all as specified and directed.
Dismantling floor, hearth or wall tiling of any description and in any position including cement mortar bedding (but not backing) complete all as specified and directed.
Hard core of broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complet as specified and directed.
M & L, for cement concrete in foundations, filling and mass concrete ect type D-2 1:4:8 (using 40mm graded stone aggregate) complete all as specified and as directed.
M&L for 75 mm thick Cement Concrete PCC 1:4:8 type D2 (Using 40mm geaded stone aggregate) as in sub base complete all as specified and directed.
M&L for 75mm thick cement concrete type C2 1:3:6 using 40mm graded stone aggregate as in plinth protection/Path/paving ect surface even and smooth complete all as specified and as directed.
M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar 1: 6 for laying floor finishes complete all as specified and directed
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match , complete all as specified and as directed.
M&L for Non Skid ceramic tiles 7 to 8 mm thick as in floor area exc 0.18 sqm but not exceeding 0.38 sqm thick set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in CM 1:6 as in floors.
All as per item No. 14 above but tiles area exc 0.18 sqm but not exceeding 0.38 sqm thick in vertical surfaces of wall set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick screed bed in CM 1:4 .
M & L for machine cut Kota stone slab 18 to 20 mm thick and min size of kota stone shall be 550x550 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing ect over and including 20mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified and directed.
M&L Kota stone slab 18 to 20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed withover and including 10mm thick rendering in cement plaster 1:4 on the other side of lathing and pointed with coloured cement complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick rendering in cement plaster 1:4 on the other side of lathing and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed
M&L 60 mm thickness machine pressed precast concrete interlocking paver block M-35 any shape and size confirming to IS 15658-2006 in grey cement glossy finish rubber mould casted laid dry over sand cushioning complete all as specified and directed.
Demolition of Brickwork or stone/ boulder masonry, built incement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' bricks (old size) straight or curved on plan, exc. 6m mean radius built, in cement mortar 1:6 as in manholes, septic tanks, soakage pits, drain etc in any position complete all as specified and directed.
M&L for brick work with sub class "B" bricks straight or curved on plan to any radius in half brick thick wall built in cement morart 1:4 complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L, 15mm thick rendering on brick or stone/concrete any surfaces in cement mortar 1: 4 on mixed with WPC @ 3% by weight of cement, surface finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured & paid seperately.
M&L for 15 mm thick rendering in cement mortar on fair faces of brick work or concrete surfaces in cement mortar (1:6) and surface finished even and smooth, complete all as specified and directed
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
M & L for 05 mm thick rendering in CM 1:3 on ceiling surfaces , finished fair and even complete all as specified and as directed
Taking down Chowkats or frames not exceeding 1.5 sqm each (Without taking off shutters from the frames) complete all as specified and directed.
M & L for two coat of oil bound distemper over a coat of Birla wall care putty on new plastered surfaces on wall incl. preparation of surfaces complete all as specified and directed. .
S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed.
S&F aluminum handles cast type, anodized of 100 mm size complete all as specified and directed.
S&F butt hinges 100mm long medium weight, cold rolled mild steel complete all as specified and directed.
S&F 100 mm long aluminium anodised , barrel tower bolt of extruded section and fixed complete all as specified and directed.
S&F steel ventilater with top hung shutter including hinges steel peg stay complete all as specified and directed
S&F 3mm thick Sheet Glass ordinary qulity and glazing with oil putty in square n.exc 0.5 sqm in each pane complete.
S&F figured glass, pin head type 4 mm thick and glazing with oil putty in square n.exc 0.5 sqm in each pane complete.
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specifeid and directed
M&L Reinforced Cement Concrete (Nominal Mix) Type B1 1:2:4 (12.5mm agg) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
M&L for mild steel TMT bars 06 mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
M&L for preparation of the newly plastered surfaces of walls & applying three coats of white wash on wall surfaces complete all as specified and directed.
M&L for preparation of the newly plastered surfaces of ceiling & applying 3 coats of white wash on ceiling surfaces complete all as specified and directed.
M&L for applying two coats of exterior emulsion paint new plaster surfaces,white or tinted on wall and including one coats white care putty to achive even and fair surfaces complete all as specified and directed .
M & L for prepartion of new steel surfaces ,exc. 10 cm width or girth and applying two coat synthetic enamel paint over one coat of red oxide primewr etc complete all as specified.
S&F rotation moulded polyethylene water storage tank capacity 500ltr (cylindrical vertical with closed top ) double layer construction , ISI marked , hoisted and fixed in position including dismantling of old tank and removing to from site complete all as specified and directed.
S&F rotation moulded polyethylene water storage tank capacity 1000 ltr (cylindrical vertical with closed top ) double layer construction , ISI marked , hoisted and fixed in position including dismantling of old tank and removing to from site complete all as specified and directed.
S&F tube Medium' grade galvanised with all fitting laid in trenches, of 50 mm dia complete all as specified and directed.
S&F gun metal gate valves with iron wheel head screwed at both ends for iron pipes of 50 mm dia complete all as directed.
S&F 20 mm dia Gun-metal, globe or gate valves, with iron wheel head , screwed both ends for iron pipe and fixed complete all as specified and as directed.
Supply and fixing of Ball brass valves with dia 50 mm,high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed.
Supply and fixing of Ball brass valves with dia 25 mm,high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed.
S&F 20mm bore dia, Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F 15 mm GI tubing medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F, 20 mm bore tubes medium grade galvanised with all fitting and fixed to walls and ceiling or laid in floor etc complete all as specified
S&F, 110mm bore, PVC (SWR) bends any radius complete all as specified and directed complete all as specified and directed.
S&F, 110mm bore, PVC (SWR) junction single (single T), equal or unequal, provided with access door complete all as specified and directed.
S&F, 75 mm bore, PVC (SWR) bends any radius complete all as specified and directed complete all as specified and directed.
S&F, 75 mm bore, PVC (SWR) junction single (single T), equal or unequal, provided with access door complete all as specified and directed.
S&F, 110 mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F, 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall etc. complete all as specified and directed.
S&F, 75mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors ect complete all as specified and directed.
S&F PVC ( SWR ) floor trap plain with grating including jointng with solvent cement and fixed in repair 75 mm dia outlet complete all as specified and directed.
M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S&F in repairs 65 to 100 mm size brass chromium plated shower rose with or without swivel joints including fixing to steel pipe or union complete all as specified and directed.
S & F 15mm dia stop valve CP fancy type screwed to unioun or GI pipe etc complete all as specified and as directed.
S&F 15mm dia of fancy type chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipr or for brass ferrule and fixed complete all as specified and directed.
S&F Vitreous china squatting pan orrissa patteren size 580x440 mm white with integral foot rest with S & P trap complete all as specified.
S&F vitreous china wash down water closet pan (pedestal pattern ) EWC white shade with required fixing arrangements and plastic water closet seat black closed pattern with flat bottom and cover complete all as specified and as directed.
S & F PVC Low level flushing cistren 10 Ltr capacety including all fitting such as flush pipe brackets complete all as specified and directed.
S&F wash hand basin vitreous china (flat back) any size including cutting for and pinning in ends of brackets complete size (550 x 400mm ) complete all as specified and directed.
S & F, Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe incl waste pipe complete all as specified and directed.
Supply only Pillar taps cast copper alloy with capstan head Chromium Plated screwed down, high pressure with or without lettered ‘HOT’ or ‘COLD’ with long screwed shanks and fly nut screwed for iron pipe and fixed complete all as specified and as directed
S & F concealed Stop valve cast copper alloy screwed down high pressure with CAPSTON HEAD handle chromium plated with long shank and cup (angular type) screwed both ends for iron pipe 15mm bore or for unions and fixed in repair.
S&F PVC Connections 15mm size and 450mm lengthcomplete all as specified and directed.
M&L for towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90 gms) all as specified and directed.
M&L for soap dish, any type, fixed to plugs with chromium plated brass screws all as specified and directed.
Supply only brass chromium plated waste fitting for wash basins and sinks with inlet and outlet, screwed for pipe or connections and with one cleaning cap, 32mm bore all as specified and directed.
S&F flushing jet spray for pedestal pattern EWC including 1 mtr long flexible pipe and brass chromium plated nuts etc complete all as spd and directed
M&L for cement concrete bed 1:4:8 type D2 to 150 mm dia drain pipes including forming cradles; in complete all as specified and directed.
S&F in repair stainless steel healt faucet with stainless steel tube and holder ect complete all as speicified and directed.
Taking down existing tarfelt from roof and removing from site all as directed.
Cutting out cracks to 'V' section in existing roofs or tarracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed.
M&L, 15mm thick screed bed or cement mortar 1: 4 on concrete surfaces mixed with WPC, surface finished even and smooth W/O using extra cement complete all as specified and as directed. (WPC shall be measured & paid seperately).
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
M&L, bitumenous based primer conforming to IS-3384-1965 @ 0.30 Kg / Sqm including preparation of roof surface complete all as specified and as directed.
M&L, for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by torch application method complete all as specified
M&L for after laying the membrane apply coat of bituminouse aluminium paint @ 200 gm/Sqm (minimum) in two coats complete all as specified and as directed.
M&L for carrying out sunken floor (area n.exc 1.5 Sqm) treatment in the following stages - (i) Taking down of existing sunken slab treatment from the sunken portion and cleaning the surfaces washing down with water and rubbish of the pemises , cleaning and filling cracks with sealing compound, brushing neat cement slurry @ 3.00kg/sqm and grouting 25mm thick cement concrete type B-0 (1:2:4) using 12.5mm graded stone aggregate on sunken slab portion and finishing the top surfaces even and smooth without using extra cement. (ii) M&L for two coat of acrylic cementitious water proofing coating (Dr FIXITpidifin 2k manufactured by M/s Pidilite Industries Ltd or equivalent) and followed by a overlay protective screed (10mm thick cement mortar (1:4) along with liquid water proofing compound approved make as per manufacturer's instructions) (iii) PCC 1:5:10 for filling in the sunken portion. (iv) Concrete for Sunken Slab shall be mixed with WP compound as per manufacture Instructions. (v) Joint of Trap/WC/Soil/PVC/CI pipes shall be properly replaced in PVC pipe and sealed with Sealing Compound. (vi) P/S traps and nahani/floor traps with long arms shall be replaced and provided as per direction of Engineer-in-charge. (vii) Testing of all traps, joints and sunken slab shall be as per IS : 1742 before filling of Sunken Slab including smoke test. (viii) After filling of Sunken floor making good as per Old FFL.
M&L Surface dressing n.exc 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in post holes (or similar holes) n. exc 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm watering and removing surplus soil to a distance n. exc 50 and making good surface in soft/loose soil all as specified and as directed.
M&L for angle iron posts and struts in fencing including cutting tops to shape (swan neck) or as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work including 40x6mm flat iron for holding chain link fencing conforming to Fe-290 Gde E-165 all as specified and as directed.
M&L for 10mm dia mild steel screw bolts, with hexogonal or square at one end and srewd the other or screwd both ends each screwd end to be fitted with washer and one hexogonal or square length exc 15cm and n. exc 22.5cm all as specified and as directed.
Fixing only galvanised chain link fencing of 4mm dia GI wire including line wire standards rails straining bolts etc including provision of binding wire and mesh size as per direction of GE Gwalior & complete all as specified and as directed.
Supply only galvanised chain link fencing of 4mm dia GI wire including line wire standards rails straining bolts etc including provision of binding wire and mesh size as per direction of GE Gwalior & complete all as specified and as directed.
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed.
S&F for Joist, channel, angle, or tee sections, Fe-410-W (Gde.E-250) quality-A or Fe 290 fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and as directed.
S&F 0.50 mm thick pre -painted galvatume aluminium zinc coating GI based corrugated steel sheet of an colour haviing tensile strength of 550 Mpa as in roof covering /cladding to wall,fixed with self tapping screws as specified colour as approved by Engr -in -Charge.
M & L, for cement concrete in floor, type B-0 1:2:4 (using 12.50 mm graded stone aggregate) complete all as specified and as directed.
M&L, for rendering 15mm thick on fair faces of brick work or concrete surface in cement plaster 1:6, finished fair and even complete all as specified and directed
M&L Preparing new surfaces of wall and applying two coats of cement base paint all as specified and directed.
Cutting of existing Cast iron pipes in position for insertion of new tees, for branch connection of 50 mm dia from 100 mm bore of pipe existing CI pipe.
Taking down carefully existing aluminum / copper point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, ceiling fan with regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed.
Taking down submain wiring of any size any type and in any position metalic/non metallic PVC conduit of wooden batten complete all as specified and directed.
Taking down unserviceable TPN DB with MCB's of any make/capacity, complete, all as specified and directed by Engr-In-Charge.
M&L, concealed point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH confirming to IS 694:2010 having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area (ISI marked with valid CML No) drawn in and including concealed non metallic rigid PVC conduit medium grade( ISI marked with valid CML No) not less than 20 mm dia confirming to IS 14930 (Part-I) 2001, with all fitting and fixing accessories and 1.5 Sqmm FRLSH PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to common earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes factory made for mounting switch, regulators etc with and including 2.8 mm thick plastic laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint inside for mounting switches. sockets etc complete for the following:-
One light point controlled by one switch.
One Exhaust fan point controlled by one switch.
One 5 pin multipurpose socket out let 5/6 Amps on the same board with other switch.
One 3 pin/5 pin switch socket outlet, 5 Amps on independent board.
All as per item No 108 here in before but point wiring with 2.5 sqmm FRLSH confirming to IS 694:2010, multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm FRLSH PVC insulated multi strand copper conductor cable as continous earth wire.
S&F switch piano, flush button single pole one way 5 Amp complete all as specified and directed.
S&F socket out let, multipurpose, 2 in 1 5 pin, 5 Amp complete all as specified and directed.
S&F switch piano, flush button single pole one way 15 Amp complete all as specified and directed.
S&F socket out let multipurpose flush type, 2 in 1 6 Pin 5/15 amps complete all as specified and directed.
S&F ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed.
S&F Lamp holder with metal ring, PVC/Polycarbonate type with back plate suitable for batten fittings non ISI Marked complete.
S&F LED Lamp 09/10 watt complete.
S&F Decorative ultra slim LED Tubelight fitting of LED with extruded polycarbonate, enviormental friendly energy efficient ready to use, 20 watt, 6500K fitting, incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor for electrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed.
S & F security light fittings better optics for uniform distribution IP 65 protection LED of 30 watt, Heat resistance glass, pressure die cast aluminium housing including 25mm dia galvanised iron pipe light grade bracket bent to shape over all length 0.60mtr fixed to wall with 02 Nos FI clamps made of 40 x 5 mm FI, 15 cm long, 8 mm dia bolts and nuts with washers grouted in wall complete including reqd length of 1.5 Sqmm PVC multistranded BIS marked, 03 core copper conductor for connection from ceiling rose to light fittings incl testing on completion all as specified and directed.
Supply & fix Exhaust fans 300mm sweep double bearing with all fixing accessories required including making hole & regd length of 3 core 1.0 sqmm PVC multistranded copper conductor, and testing complete all as specified and directed.
Supply & fixing water heater storage type stainless steel inner container, 25 Ltrs capacity, electric suitable for single phase, 50 Hz, AC Supply, 5 star rating, having Temp control rotating switch facility including all necessary fittings and fixture with minimum 1M of three core 2.5 sqmm twisted copper conductor cable PVC sheated, three pin plug top complete with necessary fittings and fixtures all as specified and directed.
S&F Sheet metal enclosures single pole and neutral with a two pin and earth plug and socket with and including one single pole MCB 20 amps, 240 volts, 10 KA complete all as specified and directed.
M&L, sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and including non metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia confirming to IS 14930 (Part-I) 2001, with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface.
S&F sheet metal enclosure double door distribution board factory made for MCB DB load link VTPN 4 way suitable for MCCB as incomer, 63 Amp,4 pole & Including MCCB 63 amps 4 pole 16 KA complete. (when MCB's are to be used) with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification including taking down all as directed by Engr-in-Charge at site.
S&F, MCB SP 240 volts, 6 to 32 Amps, 'C' series 10 KA including connection with suitable size copper lugs. complete all as specified and directed.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable (Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area 25 Sqmm 4 Core.
Sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables complete.
Bricks, old size sub class `B' laid in trenches with width wise along the alignment of the cable as protection complete.
S&F tube 'Light' grade galvanised Pipe of 50 mm dia with all fitting for cable protection, laid in trenches, fixed to wall and floor by MS shaddle & fixed with pole, 02 position by MS clamp made of 40x5 mm MS flat, complete all as specified and directed.
Taking down Old u/s water meter including all necessary fixing arrangment part by part.
S&F Of Sensus woltman type water meter with Removable Mechanism Class ''B'' Confirming to ISO : 4064/1 of Size 300 mm (12") of type R.M Including necessary fixing arrangment completed all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test. Testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI medium grade earth lead protection pipe including provn of earth test point made of 50 x 5 mm MS Flat in 'D' shape 500 mm legth grouted in wall complete 01 x 6 mm multistrand PVC insulated copper conductor ( Green Colour) to be provided from test point to DB through 20 mm dia concealed non metallic conduit complete all as specified and directed.
Supply,installation,Testing and commissioning Complete Auto softener-06 Zero B 6000L/1.5 hr including all Plumbing work and electrical connection complete all as specified and dircted by Engineer-in-charge.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable (Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area size 10 Sqmm 2 Core.
S&F MCB DB, sheet metal enclosures double door SPN 4 way with 200 Amps rated bus bar 240 volts 2 in 1 shutter type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed.
S&F, MCB SPN 20 to 40 Amps, 240 volts 'C' series 16 KA ,including connection with suitable size copper lugs complete all as specified and directed.
S&F, MCB SP 240 volts, 6 to 32 Amps, 'C' series 10 KA including connection with suitable size copper lugs. complete all as specified and directed.
Supply and laying of CPVC pipes with dia 25 mm SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed.
Supply and laying of CPVC pipes with dia 50 mm SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed.
M/s Himgiri construction
MAHARAJ KUNWAR SAHAB CONSTRUCTION
M/s. Varinder Kumar Sharma
M/s Tirupati construction
M.S. ENGINEERS
M/S YOGANSH CONSTRUCTION CO.
M/S MAHAVIR SINGH
M/S SANJAY AGARWAL
mahamaya constructions
M/s Subhash Construction Co.
M/s Anjali Construction
M/s J.B. Construction
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .