Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹4.7 CrAccepted-AOC | ₹4.7 Cr | L-1 | Accepted-AOC L-1 |
| 2 | L-2₹5.0 Cr+₹30.3 L (6.50%)Rejected-AOC VPO MAJARI TEHSIL SHRI NAINA DEVI DISTT BILASPUR HP | ₹5.0 Cr+₹30.3 L (6.50%) | L-2 | Rejected-AOC L-2 |
Tender Value
₹3.0 Cr
EMD Value
₹3.3 L
Closing Date
29 Oct 2019, 5:00 pmClosed
Executive Engineer
IPH Division NO.II,Una
P/L Rising Main S/E Pumping Machinery and allied accessories, Electrical installation and C/O Civil works for LWSS GP NehriNaranga, SalanaMaslana and operation and maintenance of the schemes for 5 years
2019_HPIPH_32137_1
8117-8216 15/10/2019
Open Tender
Civil Works
Item Rate
540 days
Una
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,500
EE IPH Division No.II Una
₹3.3 L
Yes
Una
5 Aug 2020
15 Oct 2019
30 Oct 2019
15 Oct 2019
29 Oct 2019
15 Oct 2019
15 Oct 2019 - 29 Oct 2019
19 Oct 2019
Amount
C/O Pump Houses, Je Qtrs, Boundary wall, Collection tanks,Infiltration Gallory, Raw water tank, Clear water tank, Filter Bed, Sedimentation Tanks
Excavation in foundation, trenches in earth work in all kinds of soil,such as pick work,jumper work.blasting work in hard rock and soft rock and in saturated soil etc. i/c all leads and lifts , stacking the excavated soil not more than 3 mtrs. clear form the edge of excavation and then returning the stacked soil in 15 cm layers when required into plinth, sides of foundation etc. consolidating each deposited layers by ramming and watering and then disposing of all surplus excavated earth as per the direction of the Engineer-in-Charge.
Excavation in foundation, trenches in earth work with dewatering in all kinds of soil,such as pick work,jumper work.blasting work in hard rock and soft rock and in saturated soil etc. i/c all leads and lifts , stacking the excavated soil not more than 3 mtrs. clear form the edge of excavation and then returning the stacked soil in 15 cm layers when required into plinth, sides of foundation etc. consolidating each deposited layers by ramming and watering and then disposing of all surplus excavated earth as per the direction of the Engineer-in-Charge.
Eaxcavation in earth work and filling in 15 cm layers in foundation and plinth including ramming , watering and consolidating complete in all repect in all leads and lifts and as per the direction of the .Engineer-in-Chaarge.
Providing and laying cement concrete 1: 6: 12 ( 1 cement 3 sand : 6 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads and lifts and as per the direction of the .Engineer-in-Chaarge.
Providing and laying cement concrete (M-10) 1: 3: 6 ( 1 cement : 3sand: 6 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads and lifts and as per the direction of the .Engineer-in-Chaarge.
Providing and laying cement concrete 1: 5: 10 ( 1 cement : 5 cenment: 10 g graded stone aggregate 40 mm nominal size) with 15% plum and curing complete excluding the cost of form work in Retaining wall/ Breast walls , the size of plums shall be useually 150 mm to 300 mm as per HPPWD specification in all leads and lifts and as per the direction of the .Engineer-in-Chaarge.
Stone filling behind retaining wall/ under floor in all leads and lifts and as per the direction of the .Engineer-in-Chaarge.
1st class brick work using common burnt clay building bricks in foundation and plinth in cement mortor 1:6 ( 1 cement: 6 sand ) in all leads and lifts as per the direction of the Engineer-in-Charge.
Ist class brick work using common burnt clay building bricks in superstructure in cement mortor 1:6 (1 cement :6 sand) in all lead and lifts as per the direction of the Engineer-in-Charge.
Half brick work using common burnt clay building bricks in super structure above 1st. floor level in cement mortar 1 : 4 ( 1 cement :4 sand) of 2nd. Class bricks complete in all lead and lifts as per the direction of the Engineer-in-Charge.
Providing and fixing pressed steel door frame manufactured from commercial MS sheets of 1.25 mm thickness including hinges jump lock jamb, bead if required angle thrshold of MS angle 50x25 mm or base ite of 1,25 mm presses MS welded or rigidly fixed together by mechanical means, adjustable lugs with split and tails to each jamb including steel butt hinges 2.5 mm thick with guards, lck strike plate and shock as specified and laying a coat of steel
Profile "A"
Profile "B"
Providing and fixing pannelled glazed and panalled and glazed shuttrs for doors ,windows and clerestory windows including bright finshied /black enemelled iron butt hinges with necessary screws fIst class deodar wood 40 mm thick. 2 nd class deodar wood complete in all respect and as per the direction of the Engineer - in- Charge.
Providing and laying cement concrete M-30 not less than 1:1.5:3 (1 Cement :1.50 Sand:2 stone aggregate 20mm nominal size) and curing complete excluding the cost of form work & reinforcement for reinforced concrete work in Wall (any thickness, but not less than 0.10 m thickness) attached pilasters, buttresses, plinth & string course etc. from top of foundation level upto floor two level with in all leads and lifts and as per the direction of the Engineer - in- Charge.
Providing and laying cement concrete M-20 not less than 1:1.5:3(1 Cement :1.5 Sand:3 stone aggregate 20mm nominal size) M-20 as per IS: 3370 Part-1,2009 and IS :456:2000 and curing complete excluding the cost of form work & reinforcement for reinforced concrete work in :
Suspended floors, roofs, landing and the like Floors etc. upto 200 mm thickness in all leads and lifts and as per the direction of the Engineer-in-Charge.
Providing and laying cement concreteusing M-25 not less than 1:1.5:3(1 Cement :1.5 Sand:3 stone aggregate 20mm nominal size) as per IS: 3370 Part-1,2009 and IS :456:2000 and curing complete excluding the cost of form work & reinforcement for reinforced concrete work in :
Foundation, footing and bases of columns etc. and mass concrete within all leads and lifts complete in all respect i/c carriage of materials with in all leads and lifts.
Wall (any thickness, but not less than 0.10 m thickness) attached pilasters, buttresses, plinth & string course etc. from top of foundation level upto floor two level
Suspended floors, roofs, landing and the like Floors etc. upto 200 mm thickness in all leads and lifts and as per the direction of the Engineer-in-Charge.
Arches bottom dome
Providing form work with steel plates 3.15 mm thick welded with angle iron in frame 30x30x5mm. so as to give a fair finish including centering, shuttering, struting and propping etc. with wooden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4 mtrs. and removal of the same for in situ-reinforced concrete and plain Concrete work in :-
Sides and soffits of beams,beam haunchings, cantilevrs, bressumers and lintles not exceeding 1.00 mtr.in depth in all heights from floor.
Vertial Surfaces such as wall circular or curbed in plan of (any thickness, but not less than 0.10 m thickness) attached pilasters, buttresses, plinth & string course etc. from top of foundation level upto floor two level
Flat surfaces such as soffits of suspended floors, roofs, landing and the like Floors etc. upto 200 mm thickness in all leads and lifts and as per the direction of the Engineer-in-Charge.
Providing form work of ordinary timber plankings, so as to give rough finish including centring, shuttering, strutting and propping etc. with wooden battans and ballies height of propping and centring below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete and plain In Arches upto any span in all leads and lifts and as per the direction of the Engineer-in-Charge.
Providing in RCC work smooth finishing of the exposed surface with cement mortar 1:3 ( 1 cement : 3 sand) complete in all respect with in all leads and lifts.
Steel work welded in built up section , trusses and framed work i/c cutting hoisting fixing in position and applying a priming coat of red lead paint in gretings, framed guards, bors ladders railing brackets and similar works.
Providing mild/tor steel reinforcement of RCC work i/c bending ,binding and placing in position in complete up to floor two level in all leads and lifts and as per the direction of the Engineer-in-Charge.
Cement concrete flooring 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size ) laid in one layer finished with floting coat of neat cement in all leads and lifts and as per the direction of the Engineer-in-Charge 40 mm thick.
15 mm cement plaster in single coat on rough side of brick masonry for interior plastering upto floor two level including arrises, internal rounded angle, chamfers and or rounded angles not exceeding 80 mm in girth and finished even and smooth with cement mortor 1:6 ( 1 cement :6 sand ) in all leads and lifts as per the direction of the Enginner-in-Charge.
Pointing on brick work with cement mortor 1:3 ( 1 cement: : 3 sand ) in all leads and lifts as as per the direction of the Engineer - in- Charge.Cut or weather struck/ Ruled pointing.
Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1 Cement :3 Sand: 6 graded stone aggregate 20 mm nominal size ) in all lead and lifts as per the direction of the Engineer - in- Charge.
Applying priming coat over new wood and wood based surfaces after and including preparing the surface by throughly cleaning oil, greas,dirt,and other foreign metter with ready mixed paint brushing wood primer pink complete in all respect as per the direction of the Engineer-in-Charge.
Painting two coats excluding priming coat on new wood and wood surfaces with enamel paint to give an even shade including cleaning the surface of dirt ,dust and other foreign matter sand papering and stoping complete in all respectas per the direction of the Engineer - in - Charge.
Painting two coats (excluding priming coat) on new steel and other metal surfaces with enamel paint to give an even shade including cleaning the surface of dirt ,dust and other foreign matter with enamel with enamel paint other than white complete in all respect as per the direction of the Engineer-in-Charge.
Himarchi colour wash on undecorated wall surfaces (Three coats) to give an even shade including thoroughly brooming the surfaces to remove all dirt,dust, mortar drops and other foreign matter complete in in all respect as per the direction of the Engineer-in-Charge.
White washing with lime on undecorated wall surface ( three coats) to give an even shade including throughly brooming the surface to remove all dirt ,dust mortor drops and loose scale of lime wash and other foreign matter complete in in all respect as per the direction of the Engineer-in-Charge.
Providing and fixing MS grills of required pattern in wooden frame / pressed steel frame with MS flates square / rounds bars 12 mm dia with round headed bolts and nuts of by screws in all leads and lifts and as per the direction of the Engineer - in- Charge Plain grills.
Providing 40x3mm flat iron hold fast 40 cms long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15 cms 1:3:6 ( 1 cement :3 sand : 6 graded stone aggregate 20 mm nominal size ) complete in all respect as per the direction of the Engineer -in- Charge.
Providing and fixing sliding door bolts anodized transparent or dyed to required shade and colour with screws etc. complete in all respect 250x16 mm
Providing and fixing tower bolts barrel type anodized transport or dyed to required shade and colour with screws com lete in all respect. 250x10mm.
Providing and fixing aluminium handle anodized transparent or dyed to required shade and colour with screws etc. complete in all respect 100mm dia
P/F MS fan clamps type 1 of 16 mm dia bar bent to shape with hooked ends in RCC slab during laying including painting the exposed portion of roof as per standard design complete in respect .
Providing & fixing MS man hole cover having fram size 60x60 CM made from angle iron 40x40x6 mm with 3 mm thick MS sheet cover having locking arrangment, lock & lifting handles. The fram should be duly embeded monollithically in concret during casting complete in all respect within all leads & lifts.
Fixing inlet, outlet, over flow and Scour pipe of GMS pipe of following internal dia (medium grade) including extra carriage within all leads and lifts and as per the direction of the Engineer-in-Charge.
Providing & fixing of following diaCI sluice valve (with hand wheel) make leader/ Kirlisker as per IS 780:1984 Class - I upto 300mm dia. i/c brass spindle & as per 2906 - 1984 Class II for diameter more than 300mm complete with bolts, nuts, rubber insertion etc. (The tail pieces if required shall be measured & paid seprately) complete in all respect with in all leads & lifts.
150 mm dia PN-1
125 mm dia PN-1
100 mm dia PN-1
80 mm dia PN-1
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surface (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt & remains of loose powdered materials complete in all respect
Providing and placing in horizontal layers filtering media duly graded, screened,washed and cleaned of the following grade including entire carriage of material upto all leads and lifts and as specified by the Engineer-in charge:-
Top Layer :- Fine sand(Eff.size 0.20mm to 0.40mm & uniformity coefficient 2.00 to 3.00).
2nd Layer:- Coarse sand 3mm to 6mm.
3rd Layer:- Bajri 6mm to 20mm.
4th Layer :- Bajri 20mm to 25mm.
5th Layer :- Broken stone 50mm to 75mm.
Rising Mains
Providing, laying, jointing and testing in trenches of Galvanized MSERW flanged pipes conforming to IS/ISO 3183-2007 Grade L-210 or A as per dimensions weight and test pressure mentioned below in a random length of 5 m-7m. The pipes end shall be bevelled suitable for butt welding. The M.S. flanges are to be provided 5% of total joints as per table below conforming to IS 6392-1971 ( Latest upto date amendments ) and welding of flanges with pipes as per IS: 816-1965 with electrode as per IS: 814-1967 including required Nos. and size of M.S nuts and bolts as per IS: 1369-1967 and compressed asbestos fibre jointing geskets sheet not less than 3 mm thick as per IS; 2712-1965. The welding of flanges to be done on both faces in three layers(Two inner & one outer) to make the joints leak proof and to the entire satisfaction of the Engineer - in -charge. The laying of pipes should be conformed to IS: 5822-1994 ( Earth work in trenches, M.S. flanges and butt welded joint to be mensured and paid sepretely) The pipe shall have Zinc coating as per IS 4736 in factory latest with up to date ammendements.Pipe shall be coated from both side (Inside) or outer side with the required thickness of zinc coating as per two coats mains above.
GMSERW pipe 150 mm dia 4.80 mm thick with MS flanges Table - 28
Providing,Laying , jointing & testing in trenches to be levelled to grades, and testing of GMS (heavy class) plain ended pipe to IS/ISO 1239-2004, (Part-I) the entire satisfaction of Engineer-in-charge i/c entire carriage of materials within all leads and lifts.
GMS pipe 150 mm dia (heavy class) from RD. 960 to 3000 with MS flanges Table - 28
GMS pipe 150 mm dia (heavy class) from RD. 3000 to 5400 with MS flanges Table - 17
GMS pipe 150 mm dia (heavy class) from RD. 5400 to 6700 with MS flanges Table - 5
GMS pipe 65 mm dia (Medium class) from RD. 0 to 1140 with MS flanges Table - 5 for WSS Salana Maslana.
Providing & welding of MS flanges confirming to table as specified below as per IS- 6392-1971 (latest with upto ammendment ) welding of MS flanges with GMSERW pipe on both end ( The cost of GMSERW pipe to be measured & paid for seperately)according to relevent BIS standard The welding of flanges with pipes as per IS: 816-1965 with electrode as per IS: 814-1967 including required Nos. and size of M.S nuts and bolts as per IS: 1369-1967 and compressed asbestos fibre jointing geskets sheet not less than 3 mm thick as per IS; 2712-1965. The welding of flanges to be done on both faces in three layers(two inner & one outer) to make the joints leak proof and to the entire satisfaction of the Engineer - in -charge. including carriage of material in all leads and lifts.
GMS pipe 150 mm dia (heavy class) from RD. 960 to 3000 with MS flanges Table - 28
GMS pipe 150 mm dia (heavy class) from RD. 3000 to 5400 with MS flanges Table - 17
GMS pipe 150 mm dia (heavy class) from RD. 5400 to 6700 with MS flanges Table - 5
GMS pipe 65mm dia (heavy class) from RD. 0 to 1140 with MS flanges Table - 5
Providing circumferencial butt welded joints by electrical arc welding to following dia & class pipes,welding of pipes to be done in three layers to make the joints leak proof and to achieve the minimum effective throat thickness of weld conforming to IS- 816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani oerlikon (Adore)-CITOJET/ESAB make, conforming to IS 814-1991, at site of work complete in all respects and including DPT test for joints & manual/mechnical handing of pipes in all leads and lifts to the entire satisfaction of Engineer- in- charge..
150 mm dia GMSERW/GMS Pipe
65 mm dia GMS Pipe
Distribution Systems
Providing,Laying, jointing and testing in trenches GMS pipes ( light grade) confirming to ISI specification including commissioning and cost of all fittings in respect of following diameters in distribution system (Earth work in trenches to be measured and paid for separately) including entire carriage of material in all leads and lifts as per the directoon of the Engineer-in-charge.
20mm dia.
25 mm dia.
32 mm dia.
40 mm dia.
50 mm dia.
65 mm dia.
80 mm dia.
Providing and fixing of brasss full way valves with ( hand wheel ) complete in all respect and as per the direction of the Engineer-in-Charge in all leads and lifts of the following diameters.
15mm dia.
20mm dia.
25 mm dia.
32 mm dia.
40 mm dia.
50 mm dia.
65 mm dia.
Dismentalling of of old pipe GMS pipes in existing distribution system where changing is required of following including stacking of material at site in all leads and lifts and as per the direction of the Engineer-in-Charge.
15mm dia.
20mm dia.
25 mm dia.
40 mm dia.
65 mm dia.
80 mm dia.
100 mm dia.
Re-Laying, jointing and testing in trenches GMS pipes ( light grade) confirming to ISI specification including commissioning and cost of all fittings in respect of following diameters in distribution system (Earth work in trenches to be measured and paid for separately) including entire carriage of material in all leads and lifts as per the directoon of the Engineer-in-charge.
15mm dia.
20mm dia.
25 mm dia.
40 mm dia.
65 mm dia.
100 mm dia.
Internal Electrical wiring
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable complete in all respect. "Group-C"
Wiring for power plug with (2x4 Sq.mm) PVC insulated,heat resistant flame retardant(HRFR) and low smoke single core(flexible)copper conductor cable in surface/recessed PVC conduit along with 1 No. 4 Sq.mm. HRFRLS/PVC insulated sigle core copper conductor cable for earthing as required including carriage of material with in all leads & lifts complete.
Wiring for circut wiring with (2x2.5 Sq.mm) PVC insulated,heat resistant flame retardant(HRFR) and low smoke single core(flexible)copper conductor cable in surface/recessed PVC conduit along with 1 No. 2.5 Sq.mm. HRFRLS/PVC insulated sigle core copper conductor cable for earthing as required including carriage of material with in all leads & lifts complete.
Wiring for sub-main with 2x 6 Sq. mm size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required including carriage of material with in all leads & lifts complete.
Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 3 pin 15/16 amps socket outlet and 15/16 amps, piano type switch, connections, ainting etc. as required..
Supplying and fixing backellite batten/angle holder including connection as required.
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required with in all leads & lifts complete. Ceiling Fan 1200 mm sweep, Category-A
Providing, Installation, testing and commissioning of prewired flourscent tube fitting 1x40 watt box type Cat A i.e. Bajaj make complete with balast starter and capacitor but excluding flourscent tube rod suitable to operate on 240volt single phase AC supply directly on surface with copper wiring as required complete as per direction of the Engineer-in-charge.
Supplying and fixing 40Amps to 63 Amps rating 240 Volts "L" series miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required including carriage of material within all leads and lifts. Category- A, 63 Amps.
Supplying and fixing of following way single pole and neutral sheet steel MCB distribution board 240 volts on surface/recessed completed with tinned, copper busher neutral link, earth bar, detachable gland plate inter -connections, including painting, earthing etc. as required Bus bar 8 way.
Supplying and fixing 5 Amps to 32 Amps rating 240 volts, G series miniature circuit breaker of following poles in the existing MCB, DB complete with connections testing and commissioning etc. as required Category "A", single pole.
Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for pipe earth electrode complete as required.
Supplying and laying 6 SWG G.I. wire on surface / recess for loop earthing as required complete as per direction of the Engineer-in-charge.
P/F street light fixture with CFL of 36 watts copper ballast4 feet long complete with choke starter i/c connection complete as required complete as per direction of the Engineer-in-charge.
OHSR for WSS Nehri Narnga 2,95,000 Ltrs cap with 15 mtrs Staging
Excavation in foundation, trenches in earth work in all kinds of soil,such as pick work,jumper work.blasting work in hard rock and soft rock and in saturated soil etc. i/c all leads and lifts , stacking the excavated soil not more than 3 mtrs. clear form the edge of excavation and then returning the stacked soil in 15 cm layers when required into plinth, sides of foundation etc. consolidating each deposited layers by ramming and watering and then disposing of all surplus excavated earth as per the direction of the Engineer-in-Charge.
Providing and laying cement concrete (M-10) 1: 3: 6 ( 1 cement : 3sand: 6 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads and lifts and as per the direction of the .Engineer-in-Chaarge.
Providing and laying cement concreteusing M-25 (Not less than 1:1.5:3) as per IS: 3370 Part-1,2009 and IS :456:2000 and curing complete excluding the cost of form work & reinforcement for reinforced concrete work in :
Foundation, footing and bases of columns etc. and mass concrete within all leads and lifts complete in all respect i/c carriage of materials with in all leads and lifts.
Columns pillars,post and struts.
Lintel, Beams,cantilever,girders and lintels.Sides and soffits
Stair case(except spiral stair case)excluding landing but including preparing of the surface and finishing of nosing.
Wall (any thickness, but not less than 0.10 m thickness) attached pilasters, buttresses, plinth & string course etc. from top of foundation level upto floor two level
Suspended floors, roofs, landing and the like Floors etc. upto 200 mm thickness in all leads and lifts and as per the direction of the Engineer-in-Charge.
Arches bottom dome
Providing form work with steel plates 3.15 mm thick welded with angle iron in frame 30x30x5mm. so as to give a fair finish including centering, shuttering, struting and propping etc. with wooden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4 mtrs. and removal of the same for in situ-reinforced concrete and plain Concrete work in :-
Foundation, footing and bases of columns etc. and mass concrete within all leads and lifts complete in all respect.
Columns,pillars posts,struts circular or curved in plan.
Sides and soffits of beams,beam haunchings, cantilevrs, bressumers and lintles not exceeding 1.00 mtr.in depth in all heights from floor.
Vertial Surfaces such as wall circular or curbed in plan of (any thickness, but not less than 0.10 m thickness) attached pilasters, buttresses, plinth & string course etc. from top of foundation level upto floor two level
Flat surfaces such as soffits of suspended floors, roofs, landing and the like Floors etc. upto 200 mm thickness in all leads and lifts and as per the direction of the Engineer-in-Charge.
Stair cases with slopping or stepped soffits excluding landings.
Providing form work of ordinary timber plankings, so as to give rough finish including centring, shuttering, strutting and propping etc. with wooden battans and ballies height of propping and centring below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete and plain In Arches upto any span in all leads and lifts and as per the direction of the Engineer-in-Charge.
Steel work welded in built up section , trusses and framed work i/c cutting hoisting fixing in position and applying a priming coat of red lead paint in gretings, framed guards, bors ladders railing brackets and similar works.
Providing mild/tor steel reinforcement of RCC work i/c bending ,binding and placing in position in complete up to floor two level in all leads and lifts and as per the direction of the Engineer-in-Charge.
Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1 Cement :3 Sand: 6 graded stone aggregate 20 mm nominal size ) in all lead and lifts as per the direction of the Engineer - in- Charge.
Providing under layer for plinth protection of 75 mm thick ( unconsolidated )bed dry brick/ stone aggregate 40 mm nominal size will rammed and consolidated and grouted with fine sand including preparation of ground i/c. entire carriage of material and as per direction of the Engineer-in-Charge..
Providing & fixing MS man hole cover having fram size 60x60 CM made from angle iron 40x40x6 mm with 3 mm thick MS sheet cover having locking arrangment, lock & lifting handles. The fram should be duly embeded monollithically in concret during casting complete in all respect within all leads & lifts.
Providing and Fixing inlet, outlet, over flow and Scour pipe of GMS pipe of following internal dia (medium grade) including extra carriage within all leads and lifts and as per the direction of the Engineer-in-Charge.
Providing ,fixing and welding of MS flanges conforming to IS code 6392-1971 table 5 of below noted diameter ( Latest with upto date ammendments ) welding of M.S. flanges on G.I. pipe on both ends according to relevent BIS standard and detailed technical specification ) and provided with nuts,bolts of required size complete in all respect and as per diection of the Engineer-in-Charge.
100 mm dia for Fixing inlet, outlet, over flow and Scour pipe of GMS pipe
Providing & fixing of following diaCI sluice valve (with hand wheel) as per IS 780:1984 Class - I upto 300mm dia. i/c brass spindle & as per 2906 - 1984 Class II for diameter more than 300mm complete with bolts, nuts, rubber insertion etc. (The tail pieces if required shall be measured & paid seprately) complete in all respect with in all leads & lifts.
100 mm dia PN-1
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surface (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt & remains of loose powdered materials complete in all respect
Provision for design and drawing of all RCC reservoirs, infiltration gallory, treatment unit and its vetting charges and provision for concrete mix designs from the reputed institutions i.e IIT/NIT/PEC Chandigarh)
Pumping Machineries.
Submersible Pump set for WSS Nehri Narnga
Supply and errection of submersible pumping set of reputed make such as KSB/Calama/BS/Oswal / worthigton/ LUBI/ GROUNDFOS/HINDUSTAN/SEERAX/SABAR/Johnston/Amrut conforming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ;5659-1978 with upto date amendments,suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better liffe for shaft conforming to BIS specifications The pump shall be directly coupled to suber-sible squirrel cage electric induction motor of same make conforming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed,lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear and tear.It should also be fitted with a device to make up expa-of water with heating of motor The pumpset should include water level guard i/c cable ,errection clamps, cable clips and suitable for opertion on data given below. Specifications offered a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation
Discharge, (Q) 13.31 LPS
Total Head ( H ) 56.30 Mts.
SWL in Tubewell 22.86 mtr. bgl.
R.L. point of discharge 892.90 mtr
R.L. of Pump House = 889.90 mtr
Seasonal fluctuation + draught condition + bowl assembly.9 mtrs.
Drawdown in Tubewell 13.72 mtrs.
StaticHead = 48.58 mtrs.
Static suction lift 58.58 mtrs.
Rising main Column pipe
Length 10.00 mtrs Length 55.58 mtr
Dia 125 mm (M) Dia 125 mm (M)
Class GMS
iv) Pumping hours 8hours
v) Alititude of installations above M.S.L 450.00mtr
vi) Characteristic of water
a) Temperature 20 Deg Cel.
b)Turbidity __________________JTU
c) Allkanity _________________mg/1Ca Co3
d) Size of solids _______________ mm
e) others
vii) Depth of T/well 125.50 mtr
viii) Dia of T/well assembly 300/200 mm
ix) Length of assembly pipe 125.50 mtr
x) Dia of housing pipe 300mm
xi) Length of housing pipe 70 mtr
OPERATING CONDITIONS
i) Type of current A.C Three phases.
ii) Frequency 50 Cycles/ Sec.
iii) Rated Voltage 415+/-15% Volts
iv) System of earthing Double Loop earthing as per BIS 3843-1987 latest
v) Speed of Revolution __________________ RPM 2900
MOTOR
i) Ref to BIS code BIS 9283-1979 with upto date amendments
ii) Type of enclousre of motr As per BIS :4691-1985 (latest)
iii) Mechnical out put in HP
iv) Class of insulation : Class B The motor should be able to withstand intial current of 2.50 times the rated current for two minutes without suffering damages of permanet deformations
i) Ref to BIS code BIS 5659-1978 with upto date amendments
ii) Driver Type Electric drivern
iii) Operating Range -15%to +10% of Total head at duty point
iv) Deliver size of Pump ;---------- (to be quoted by tenderer)
Providing ICTP Main Switch with HRC fuses of Havell/L&Tmake and having capacity 30%extra of the operational rating as per IS : 4064-1978 with upto date amendments. ICTP Switch: i) Make: ii) Type: iii) Capacity: 63 Amp.
Providing MS Sheet steel fabricated floor mounted switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. Switch Board. i) Drawing. ii) layout Plan.
MCB of L&T/Havells make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB (1) Make (ii) Type iii) Range iv) Capacity. 40 Amp
ELCB of recommended make L&T/Havells as per IS ;2516-1985 with up to date ammendments, and of suitable range which should have control box , operating handle and trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELCB I) MAKE II) Type iii ) Range iv) Capacity 40 Amp
The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition ) Voltage Monitor Relay I) MAKE II) Type iii ) Range 0-500 amp
Bus bar chamber of L&T / Hevells make having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current one copper bar of half the rating of full length for neutral phase as per IS : 8084-1976 and IS: 11353-1985 read with BIS : 5578- 1985 with upto date ammendments Three phase indicator lamps complete with toggle switches for Bus Bar Chamber individual motors as per IS: 3452 (P-I&II) with upto date ammendments. i)Type ii)Make iii)Rating
Capacitor of BHEL/GEC/ L&T make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter/IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB Capacitor i) Type ii) Make iii) Range. 5KVAR
Providing suitable oil immersed star delta starter of Kilburn/L&T/ Havells/IMP make as per IS : 8544-1979 with'upto date amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic 'type overload release and dashpot, time lag, under voltage release with or without 'initial oil filling as the case may be with single phase prventor as per IS ;1248 ( P-5)1983 with up to date amendments. Starter i) Type ii) Make
Providing and fixing of double flange Cast Iron Sliuce valve of Leader / Kirloskar make for the Column pipe and capable of withstanding the normal seat pressure and as per IS 780-1984(Cast Iron) with latest ammendments PN 1.0 in Column pipe 125 mm dia.
Providing and fixing of double flanged swing type cast iron Reflux valve of Kirloskar/Leader make having Bye pass arrangement on the rising main and capable of 'withstanding normal Seat Pressure as per IS:5312-1984 (P-I) (Cast Iron) with latest ammendmets PN 1.0 in R/main 125 mm dia.
Providing pressure gauge of Prega/Precision make complete with all accessories such as stop cock, Copper tubing as per IS: 3624-1987 with upto date ammendments. Pressure Gauge i)Make ii)Range.
Supply of PVC 3 core copper cable jointless, flat water proof cable as per BIS 694-1998 latest with upto date amendments, suitable for the pumpsets offered from MCCB to motor including all other electrical equipments/ accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor . The type, size and make shall be subject to approval of HPSEB authorities. Submersible Cable i)Make. ii) Size. 6mm Sq.
lowering of GMS Column pipe assembly 125 mm dia(MG) including MS flanges of Table 17 as per IS : 6392-1971 with upto date amendments, rubber/asbestos gasket of min. 3mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 . The Column pipe shall be as per relevent IS Code The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main . The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. Column Pipe i) Size 125 mm dia. ii) Class GMS. iii) length. (The pipe shall be issued free of cost at divisional store. However MS flanges will be provided by the firm)
Providing and laying copper PVC insulated 3 core armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster/IEC/ICC/ EICO/National / Grandlay make including all othe accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable. Suppy side From starter to Motor and switch) i) Size 4mm Sq. ii) Make finolox /Havells iii) Type armound power cable iv) Capacity v) Core. 3
Installation of all above items as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated 3 core armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster/IEC/ICC/ EICO/National / Grandlay make including all othe accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable. Suppy side From meter of HPSEB to Bus Bar and Switch) i) Size 6mm Sq. ii) Make finolox /Havells iii) Type armound power cable iv) Capacity v) Core. 3
Providing and fixing double earthing with G.I. wire / plate of 600x600x6.3mm thick electrode complete with material such as thimble, nuts and bolts,charcoal,salt, 25x5mm copper strip as per IS 3043-1987 with upto date amendments for motors and other eletrical equipments and digging of pits etc. complete in all restect as per the dirction of the Engineer-in-Charge. G.I. flat 20x3mm 15 to 50HP.
Centrifugal Pumping Machinery for WSS Nehri Naranga
Providing horizontal spindle ,horizontal / radial split casing / end suction (back pull out arrangement). Single / double / multi stage centrifugal pump or combination of pumps in series / parallel of recommended make such as Mather and Platt /KSB/Beacon weir/Kirloskar / BE/ Jyoti/LUBI/GROUNDFOS/HINDUSTAN as per BIS IS 1520 1980 with upto date ammendments read with IS- 9137. 1978 or latest edition suitable for lifting water for under mentioned characteristic with Bronze impellers / priming funnels, casing ring and shaft sleeves of Bronze shaft of stainless steel with cast iron casing, coupled directly through a flexible coupling on a common cast iron/cast steel base plate (base plate to be framed from the manufacturers of the pumping unit only) to slipring/Squirrel cage screen protected drip proof induction motor/,motors of standard make such as Kirloskar /Bhel /Crompton/NGEF /GEC/ Seimens /jyoti/ LUBI/GROUNDFOS/HINDUSTAN and suitable for operation on 415 (+/-5%) volts. 50 Cycles/Sec., 3 phase AC electric supply. The power of electric motor/motors should be at least + 10% in excess of the maximum power required by the pump/pumps in the Operation range of (+10%) and (-15%) of the duty point head. The motor/motors as per IS 325 IS 1978 with upto date amendments read with IS 900 1972 it should include cost of Bearing. Nuts, Bolts and painting etc. and should meet the following requirements.
Coupling
Base Plate
Discharge (Q) 13.31 LPS.
Total Head (H) 243.26 mtrs.
a)LWL In collection tank 100.50 mtr
b)R.L. of shaft 100.00 mtrs.
c)R.L. of discharge Pt. 289.03 mtrs.
d)Suction lift.
e)Discharge Head
f) Static Head 189.03 mtrs.
Rising main.
Length 6700 mtrs.
Diameter 150 MM
Class GMSERW/ GMS (H)/(M)
Pumping hours. 8 hours.
Altitude of installations above M.S.L 450.00 mtrs.
Characteristic of Water
a)Temperature 20 Deg.Col.
b)Turbidity ________ JTU
c)Alloanity _________ mg/1 ca Co3
d)Size of solids __________ mm
e) Others.
Providing ICTP Main Switch with HRC fuses of Kilburn/L&T / Havells/Siemens/Standard make and having capacity 30% extra of the operational rating as per IS-4064 : 1978 with upto date amendments, immediately after the Energy meter of the HPSEB. ICTP Switch: i)Make ii)Type iii)Capacity: 250 Amp
Providing MS Sheet, steel fabricated floor mounted switch board i/c angle iron post of suitable height and size ISA 40x40x6mm duly painted with steel sheet of 16 Gauge comprising and capable of mounting the following acccessories with all internal connections. Panel/Switch Board. i)Drawing ii)Layout Plan.
OCB of Kilburn/ L&T/MEI /GEC make and of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516-1985 with upto date amendments. OCB i)Make ii)Type iii)Range iv)Capacity. 200amp.
ELR OP of recommended make L&T/Havells as per IS ;2516-1985 with up to date ammendments, and of suitable range which should have control box , operating handle and trip / reset bush button on / off of indicators,reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELR I) MAKE II) Type iii ) Range iv) Capacity. 200 amp
The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage reverse phasing, overloading and phase voltage difference as per IS: 3842 (Latest Edition). Voltage Monitor Relay: i)Make ii)Type iii)Range 0 to 500 amp.
Power factor meter of AE/L&T make as per relevent IS Code with upto date ammendments.i)Make ii)Type iii)Range
Frequency meter of AE/L&T make as per relevent IS Code with uptodate ammendments. .i)Make ii)Type iii)Range
Bus bar chamber of L&T / Havells make having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current one copper bar of half the rating of full length for neutral phase as per IS : 8084-1976 and IS: 11353-1985 read with BIS : 5578- 1985 with upto date ammendments. Bus Bar Chamber i)Type ii)Make iii)Rating
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 (P-I&II) with upto date ammendments. i)Type ii)Make iii)Capacity.
Pdg Hour run meter of recommended make of suitable capacity as per IS:722 (latest edition) i) Type ii) Make iii) Range
Capacitor of Mechell/BHEL/GEC/ L&T make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter/IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB Capacitor i) Type ii) Make iii) Range. 18 KVAR
Providing suitable ATS starter of L&T/Hevells/Kilburn make as per IS: 8544-1987 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type overload release and dashpot, time lag, under voltage release with or without initial oil filling as the case mayu be with single phase preventor as per IS 1248 (P-V)-1983 with upto date ammendments.Star Delta Starter i)Type ii)Make Single phase Preventor i)Type ii)Make
Providing and fixing of double flanged cast iron sluice valve of kirloskar/Leader / Kartar/Kilburn /BHEL / GLAD / Foures / BIR make for suction pipe and capable of withstanding the normal seat pressure as per IS 780-1984 with latest ammendments i) 100 mm dia class PN1.00 cast steel
Providing and fiximg of double flanged Cast steel Sluice valve of Leader/Kirloskar make of 150 mm dia for the delivery pipe of pump and capable of with standing the normal Seat Pressure as per BIS 1414 API 600 (Cast steel) as the case may be with latest ammendments. Sluice Valve i)Make ii)Class ASA 150 iii)Seat pressure(MPa) iv)Material Cast steel
Providing and fiximg of double flanged Cast steel double flanged reflux valve of Leader/Kirloskar make of 150 mm dia class- ASA 300 for the delivery pipe of pump and capable of with standing the normal Seat Pressure as per BIS 1414 API 600 (Cast steel) with nuts and bolts and rubber insertion shee of 52 kgf/cm2 complete in all respect.. Reflux Valve i)Make ii)Class ASA 300 iii)Seat pressure(MPa) iv)Material Cast steel
Providing and fiximg of double flanged swing type Cast steel Reflux valve of Leader/Kirloskar make 150 mm dia having Bye pass arrangement on the rising main of the Pump and capable of with standing normal Seat Pressure as as per BIS: 1414 API-600 with upto date ammendments. Reflux Valve i)Make ii)Class ASA 300 iii)Seat pressure(MPa) iv)Material Cast steel
Providing 100 mm dia circular dial pressure gauge of Prega/Precision make complete with all accessories such as stop cock, Copper tubing as per IS: 3624-1987 with upto date ammendments. i)Make ii)Range.
Installation of all above item as per the systematic drawing attached with the tender documents or as per the direction of Engineer-in Charge.The contarctor should ensure proper jointing of delivery pipe line of pump with the Rising main including all necessary accessories like increaser /reducer specials etc. as per site conditions and as per direction of the Engineer-in Charge.
Fixing of double flanged GMS piping work(layout to be approved by Engineer-in-Charge) for suction and delivery pipes suitable to pumps offered and common header as per the rising main respectively complete with all specials such as bends,Tees,Reducers Inceasers with companion flanges matching with the relevant specifications of the accessories as indicated in the Drawing i/c rubber/ asbestos gasket of 3 mm thickness as per IS : 2712-1979 and required number of Nuts and Bolts as per 1364-1983.-the pipes shall be as per relevent IS code and to withstand 1.5 times total head. (The pipe shall be issued free of cost at divisional store. However MS flanges will be provided by the firm)
i) Suction Pipe 100 mm dia. GMS pipe (L)
ii) Delivery Pipe 150 mm dia MSERW pipe L210Or A
iii) Common Header 150mm dia. MSERW pipe L 210 or rage Aand will extend upto 5 metres from the outer wall of the pump house in the direction of Rising main of 100 mm dia to be joined.
Providing and laying 3 core copper PVC Insulated armoured power cable(One cable carrying all the three phases) of suitable size and capacity to motors and all other elelctrical equipments as per IS: 1554(P-I)1988 or latest with upto date amendments of Seimen/Gloster/IEC/ICC/EICO/National/Grandlay make including all other accessories such as thimble, flelxible pipes, solder, nuts & bolts, cable glands etc. laid in pipes or trenches under floor.
Armoured Power Cable (A) Motor side (From Switch to Starter & Starter to motor) i) Size 50 mm2 ii) Make iii)Type iv) Capacity v) Core 3
(B) Supply Side (From meter of HPSEB to Bus Bar & Switch) i) Size 70 mm2 ii) Make iii) Type iv) Capacity v) Core 3
Providing and fixing double loop earthing with Copper wire/plate 600 mm x 600mm x3.15mm thick electrode complete with material such as thimble, Nuts & Bolts charcoal, salt as per IS:3043-1987 with upto date amenments GI plate & strip of suitable size for motors and other electrical equipments and digging ofpits etc. complete in all respect as per the direction of the Engineer-in-Charge. Copper flat 25x3mm above 50HP (Copper plate 600 mm x 600mm x3.15mm)
Submersible Pump set for WSS Slana Maslana
Supply and errection of submersible pumping set of reputed make such as KSB/Calama/BS/Oswal / worthigton/ LUBI/ GROUNDFOS/HINDUSTAN/SEERAX/SABAR/Johnston/Amrut conforming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ;5659-1978 with upto date amendments,suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better liffe for shaft conforming to BIS specifications The pump shall be directly coupled to suber-sible squirrel cage electric induction motor of same make conforming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed,lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear and tear.It should also be fitted with a device to make up expa-of water with heating of motor The pumpset should include water level guard i/c cable ,errection clamps, cable clips and suitable for opertion on data given below. Specifications offered a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation
Discharge, (Q) 2.63 LPS
Total Head ( H ) 56.84 Mts.
SWL in Raw water Tank 2.00 mtr. bgl.
R.L. point of discharge 98.00 mtr
R.L. of Infiltration of Gallery = 71.40 mtr
Seasonal fluctuation + draught condition + bowl assembly.9 mtrs.
Drawdown in Raw water Tank 0.00 mtrs.
StaticHead = 26.60 mtrs.
Static suction lift 36.60 mtrs.
Rising main Column pipe
Length 1140 mtrs Length 2.00 mtr
Dia 65 mm (M) Dia 65 mm (M)
Class GMS
iv) Pumping hours 8hours
v) Alititude of installations above M.S.L 700 mtr
vi) Characteristic of water
a) Temperature 25 Deg Cel.
b)Turbidity __________________JTU
c) Allkanity _________________mg/1Ca Co3
d) Size of solids _______________ mm
e) others
OPERATING CONDITIONS
i) Type of current A.C Three phases.
ii) Frequency 50 Cycles/ Sec.
iii) Rated Voltage 415+/-15% Volts
iv) System of earthing Double Loop earthing as per BIS 3843-1987 latest
v) Speed of Revolution __________________ RPM 2900
MOTOR
i) Ref to BIS code BIS 9283-1979 with upto date amendments
ii) Type of enclousre of motr As per BIS :4691-1985 (latest)
iii) Mechnical out put in HP
iv) Class of insulation : Class B The motor should be able to withstand intial current of 2.50 times the rated current for two minutes without suffering damages of permanet deformations
i) Ref to BIS code BIS 5659-1978 with upto date amendments
ii) Driver Type Electric drivern
iii) Operating Range -15%to +10% of Total head at duty point
iv) Deliver size of Pump ;---------- (to be quoted by tenderer)
Providing ICTP Main Switch with HRC fuses of Havell/L&Tmake and having capacity 30%extra of the operational rating as per IS : 4064-1978 with upto date amendments. ICTP Switch: i) Make: ii) Type: iii) Capacity: 16 Amp.
Providing MS Sheet steel fabricated floor mounted switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. Switch Board. i) Drawing. ii) layout Plan.
MCB of L&T/Havells make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB (1) Make (ii) Type iii) Range iv) Capacity. 32 Amp
ELCB of recommended make L&T/Havells as per IS ;2516-1985 with up to date ammendments, and of suitable range which should have control box , operating handle and trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELCB I) MAKE II) Type iii ) Range iv) Capacity 25 Amp
The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition ) Voltage Monitor Relay I) MAKE II) Type iii ) Range 0-500 amp
Bus bar chamber of L&T / Hevells make having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current one copper bar of half the rating of full length for neutral phase as per IS : 8084-1976 and IS: 11353-1985 read with BIS : 5578- 1985 with upto date ammendments Three phase indicator lamps complete with toggle switches for Bus Bar Chamber individual motors as per IS: 3452 (P-I&II) with upto date ammendments. i)Type ii)Make iii)Rating
Capacitor of BHEL/GEC/ L&T make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter/IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB Capacitor i) Type ii) Make iii) Range. 2.00KVAR
Providing suitable oil immersed DOL starter of Kilburn/L&T/ Havells/IMP make as per IS : 8544-1979 with'upto date amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic 'type overload release and dashpot, time lag, under voltage release with or without 'initial oil filling as the case may be with single phase prventor as per IS ;1248 ( P-5)1983 with up to date amendments. Starter i) Type ii) Make
Providing and fixing of double flange Cast Iron Sliuce valve of Leader / Kirloskar make for the Column pipe and capable of withstanding the normal seat pressure and as per IS 780-1984(Cast Iron) with latest ammendments PN 1.0 in Column pipe 65 mm dia.
Providing and fixing of double flanged swing type cast iron Reflux valve of Kirloskar/Leader make having Bye pass arrangement on the rising main and capable of 'withstanding normal Seat Pressure as per IS:5312-1984 (P-I) (Cast Iron) with latest ammendmets PN 1.0 in R/main 65mm dia.
Providing pressure gauge of Prega/Precision make complete with all accessories such as stop cock, Copper tubing as per IS: 3624-1987 with upto date ammendments. Pressure Gauge i)Make ii)Range.
Supply of PVC 3 core copper cable jointless, flat water proof cable as per BIS 694-1998 latest with upto date amendments, suitable for the pumpsets offered from MCCB to motor including all other electrical equipments/ accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor . The type, size and make shall be subject to approval of HPSEB authorities. Submersible Cable i)Make. ii) Size. 2.5mm Sq.
lowering of GMS Column pipe assembly 65 mm dia(MG) including MS flanges of Table 17 as per IS : 6392-1971 with upto date amendments, rubber/asbestos gasket of min. 3mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 . The Column pipe shall be as per relevent IS Code The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main . The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. Column Pipe i) Size 100 mm dia. ii) Class GMS. iii) length. (The pipe shall be issued free of cost at divisional store. However MS flanges will be provided by the firm)
Providing and laying copper PVC insulated 3 core armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 (P-I ) 1988 or latest with upto date amendments of Seimen /Gloster/IEC/ICC/ EICO/National / Grandlay make including all othe accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable. (Suppy side From starter to metre) i) Size 2.5 mm Sq. ii) Make finolox /Havells iii) Type armound power cable iv) Capacity v) Core. 3
Installation of all above items as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated 3 core armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster/IEC/ICC/ EICO/National / Grandlay make including all othe accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable. Suppy side From meter of HPSEB to Bus Bar and Switch) i) Size 2.5 mm Sq. ii) Make finolox /Havells iii) Type armound power cable iv) Capacity v) Core. 3
Providing and fixing double earthing with G.I. wire / plate of 600x600x6.3mm thick electrode complete with material such as thimble, nuts and bolts,charcoal,salt, 25x5mm copper strip as per IS 3043-1987 with upto date amendments for motors and other eletrical equipments and digging of pits etc. complete in all restect as per the dirction of the Engineer-in-Charge. G.I. Wire SWG-8 for upto 15 HP
Centrifugal Pump Sets for Village Dulehan
Providing horizontal spindle ,horizontal / radial split casing / end suction (back pull out arrangement). Single / double / multi stage centrifugal pump or combination of pumps in series / parallel of recommended make such as Mather and Platt /KSB/Beacon weir/Kirloskar / BE/ Jyoti/LUBI/GROUNDFOS/HINDUSTAN as per BIS IS 1520 1980 with upto date ammendments read with IS- 9137. 1978 or latest edition suitable for lifting water for under mentioned characteristic with Bronze impellers / priming funnels, casing ring and shaft sleeves of Bronze shaft of stainless steel with cast iron casing, coupled directly through a flexible coupling on a common cast iron/cast steel base plate (base plate to be framed from the manufacturers of the pumping unit only) to slipring/Squirrel cage screen protected drip proof induction motor/,motors of standard make such as Kirloskar /Bhel /Crompton/NGEF /GEC/ Seimens /jyoti/ LUBI/GROUNDFOS/HINDUSTAN and suitable for operation on 415 (+/-5%) volts. 50 Cycles/Sec., 3 phase AC electric supply. The power of electric motor/motors should be at least + 10% in excess of the maximum power required by the pump/pumps in the Operation range of (+10%) and (-15%) of the duty point head. The motor/motors as per IS 325 IS 1978 with upto date amendments read with IS 900 1972 it should include cost of Bearing. Nuts, Bolts and painting etc. and should meet the following requirements.
Coupling
Base Plate
Discharge (Q) 0.99 LPS.
Total Head (H) 113.59 mtrs.
a)LWL In sump well 95.00 mtr
b)R.L. of shaft 95.00 mtrs.
c)R.L. of discharge Pt. 204.25 mtrs.
d)Suction lift.
e)Discharge Head
f) Static Head 109.25 mtrs.
Rising main.
Length 980 mtrs.
Diameter 80 MM
Class GMS (M)
Pumping hours. 8 hours.
Altitude of installations above M.S.L 450 mtrs.
Characteristic of Water
a)Temperature ________Deg.Col.
b)Turbidity ________ JTU
c)Alloanity _________ mg/1 ca Co3
d)Size of solids __________ mm
e) Others.
Providing ICTP Main Switch with HRC fuses of Kilburn/L&T / Havells/Siemens/Standard make and having capacity 30% extra of the operational rating as per IS-4064 : 1978 with upto date amendments, immediately after the Energy meter of the HPSEB. ICTP Switch: i)Make ii)Type iii)Capacity: 16.00 Amp
Providing MS Sheet, steel fabricated floor mounted switch board i/c angle iron post of suitable height and size ISA 40x40x6mm duly painted with steel sheet of 16 Gauge comprising and capable of mounting the following acccessories with all internal connections. Panel/Switch Board. i)Drawing ii)Layout Plan.
MCB of Kilburn/ L&T/MEI /GEC make and of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516-1985 with upto date amendments. OCB i)Make ii)Type iii)Range iv)Capacity. 32.00 Aamp.
ELCB of recommended make L&T/Havells as per IS ;2516-1985 with up to date ammendments, and of suitable range which should have control box , operating handle and trip / reset bush button on / off of indicators,reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELR I) MAKE II) Type iii ) Range iv) Capacity. 25.00 Aamp
The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage reverse phasing, overloading and phase voltage difference as per IS: 3842 (Latest Edition). Voltage Monitor Relay: i)Make ii)Type iii)Range 0 to 500 amp.
Power factor meter of AE/L&T make as per relevent IS Code with upto date ammendments.i)Make ii)Type iii)Range
Frequency meter of AE/L&T make as per relevent IS Code with uptodate ammendments. .i)Make ii)Type iii)Range
Bus bar chamber of L&T / Havells make having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current one copper bar of half the rating of full length for neutral phase as per IS : 8084-1976 and IS: 11353-1985 read with BIS : 5578- 1985 with upto date ammendments. Bus Bar Chamber i)Type ii)Make iii)Rating
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 (P-I&II) with upto date ammendments. i)Type ii)Make iii)Capacity.
Pdg Hour run meter of recommended make of suitable capacity as per IS:722 (latest edition) i) Type ii) Make iii) Range
Capacitor of Mechell/BHEL/GEC/ L&T make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter/IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB Capacitor i) Type ii) Make iii) Range. 2.00 KVAR
Providing suitable DOL starter of L&T/Hevells/Kilburn make as per IS: 8544-1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type overload release and dashpot, time lag, under voltage release with or without initial oil filling as the case mayu be with single phase preventor as per IS 1248 (P-V)-1983 with upto date ammendments. DOL Starter i)Type ii)Make Single phase Preventor i)Type ii)Make
Providing and fixing of double flange Cast steel Sliuce valve of Leader / Kirloskar make for the Delivery pipe and capable of withstanding the normal seat pressure and as per IS 780-1984(Cast Iron) ) with latest ammendments 80mm dia. Class ASA 150
Providing and fixing of double flanged swing type cast steel Reflux valve of Kirloskar/Leader for the Delivery pipe and capable of withstanding the normal seat pressure and s per IS 5312-2004(Cast Iron)with latest ammendments 80mm dia. Class ASA 150.
Providing and fixing of double flanged swing type cast steel Reflux valve of Kirloskar/Leader for Rising main and capable of withstanding the normal seat pressure and s per IS 5312-2004(Cast Iron)with latest ammendments 80mm dia. Class ASA 150.
Providing 100 mm dia circular dial pressure gauge of Prega/Precision make complete with all accessories such as stop cock, Copper tubing as per IS: 3624-1987 with upto date ammendments. i)Make ii)Range.
Installation of all above item as per the systematic drawing attached with the tender documents or as per the direction of Engineer-in Charge.The contarctor should ensure proper jointing of delivery pipe line of pump with the Rising main including all necessary accessories like increaser /reducer specials etc. as per site conditions and as per direction of the Engineer-in Charge.
Fixing of double flanged GMS piping work(layout to be approved by Engineer-in-Charge) for suction and delivery pipes suitable to pumps offered and common header as per the rising main respectively complete with all specials such as bends,Tees,Reducers Inceasers with companion flanges matching with the relevant specifications of the accessories as indicated in the Drawing i/c rubber/ asbestos gasket of 3 mm thickness as per IS : 2712-1979 and required number of Nuts and Bolts as per 1364-1983.-the pipes shall be as per relevent IS code and to withstand 1.5 times total head. (The pipe shall be issued free of cost at divisional store. However MS flanges will be provided by the firm)
i) Suction Pipe 80 mm dia. GMS pipe (L)
ii) Delivery Pipe 80 mm dia. GMS (M) flanged table- 17
iii) Common Header 80 mm dia. (Heavy) flanged table 17 and will extend upto 5 metres from the outer wall of the pump house in the direction of Rising main of 80 mm dia to be joined.
Providing and laying 3 core copper PVC Insulated armoured power cable(One cable carrying all the three phases) of suitable size and capacity to motors and all other elelctrical equipments as per IS: 1554(P-I)1988 or latest with upto date amendments of Seimen/Gloster/IEC/ICC/EICO/National/Grandlay make including all other accessories such as thimble, flelxible pipes, solder, nuts & bolts, cable glands etc. laid in pipes or trenches under floor.
Armoured Power Cable (A) Motor side (From Switch to Starter & Starter to motor) i) Size 2.5 mm2 ii) Make iii)Type iv) Capacity v) Core 3
(B) Supply Side (From meter of HPSEB to Bus Bar & Switch) i) Size 2.5mm2 ii) Make iii) Type iv) Capacity v) Core 3
Providing and fixing double loop earthing with Copper wire/plate 600 mm x 600mm x3.15mm thick electrode complete with material such as thimble, Nuts & Bolts charcoal, salt as per IS:3043-1987 with upto date amenments GI plate & strip of suitable size for motors and other electrical equipments and digging ofpits etc. complete in all respect as per the direction of the Engineer-in-Charge. GI wire SWG-8
Centrifugal Pump Sets for Village Maslana
Providing horizontal spindle ,horizontal / radial split casing / end suction (back pull out arrangement). Single / double / multi stage centrifugal pump or combination of pumps in series / parallel of recommended make such as Mather and Platt /KSB/Beacon weir/Kirloskar / BE/ Jyoti/LUBI/GROUNDFOS/HINDUSTAN as per BIS IS 1520 1980 with upto date ammendments read with IS- 9137. 1978 or latest edition suitable for lifting water for under mentioned characteristic with Bronze impellers / priming funnels, casing ring and shaft sleeves of Bronze shaft of stainless steel with cast iron casing, coupled directly through a flexible coupling on a common cast iron/cast steel base plate (base plate to be framed from the manufacturers of the pumping unit only) to slipring/Squirrel cage screen protected drip proof induction motor/,motors of standard make such as Kirloskar /Bhel /Crompton/NGEF /GEC/ Seimens /jyoti/ LUBI/GROUNDFOS/HINDUSTAN and suitable for operation on 415 (+/-5%) volts. 50 Cycles/Sec., 3 phase AC electric supply. The power of electric motor/motors should be at least + 10% in excess of the maximum power required by the pump/pumps in the Operation range of (+10%) and (-15%) of the duty point head. The motor/motors as per IS 325 IS 1978 with upto date amendments read with IS 900 1972 it should include cost of Bearing. Nuts, Bolts and painting etc. and should meet the following requirements.
Coupling
Base Plate
Discharge (Q) 1.64 LPS.
Total Head (H) 96.43 mtrs.
a)LWL In sump well 95.00 mtr
b)R.L. of shaft 95.00 mtrs.
c)R.L. of discharge Pt. 185.10 mtrs.
d)Suction lift. +tive.
e)Discharge Head
f) Static Head 90.10 mtrs.
Rising main.
Length 950 mtrs.
Diameter 80 MM
Class GMS (M)
Pumping hours. 8 hours.
Altitude of installations above M.S.L 450 mtrs.
Characteristic of Water
a)Temperature 20 Deg.Col.
b)Turbidity ________ JTU
c)Alloanity _________ mg/1 ca Co3
d)Size of solids __________ mm
e) Others.
Providing ICTP Main Switch with HRC fuses of Kilburn/L&T / Havells/Siemens/Standard make and having capacity 30% extra of the operational rating as per IS-4064 : 1978 with upto date amendments, immediately after the Energy meter of the HPSEB. ICTP Switch: i)Make ii)Type iii)Capacity: 16.00 Amp
Providing MS Sheet, steel fabricated floor mounted switch board i/c angle iron post of suitable height and size ISA 40x40x6mm duly painted with steel sheet of 16 Gauge comprising and capable of mounting the following acccessories with all internal connections. Panel/Switch Board. i)Drawing ii)Layout Plan.
MCB of Kilburn/ L&T/MEI /GEC make and of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516-1985 with upto date amendments. OCB i)Make ii)Type iii)Range iv)Capacity. 32.00 Aamp.
ELCB of recommended make L&T/Havells as per IS ;2516-1985 with up to date ammendments, and of suitable range which should have control box , operating handle and trip / reset bush button on / off of indicators,reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELR I) MAKE II) Type iii ) Range iv) Capacity. 25.00 Aamp
The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage reverse phasing, overloading and phase voltage difference as per IS: 3842 (Latest Edition). Voltage Monitor Relay: i)Make ii)Type iii)Range 0 to 500 amp.
Power factor meter of AE/L&T make as per relevent IS Code with upto date ammendments.i)Make ii)Type iii)Range
Frequency meter of AE/L&T make as per relevent IS Code with uptodate ammendments. .i)Make ii)Type iii)Range
Bus bar chamber of L&T / Havells make having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current one copper bar of half the rating of full length for neutral phase as per IS : 8084-1976 and IS: 11353-1985 read with BIS : 5578- 1985 with upto date ammendments. Bus Bar Chamber i)Type ii)Make iii)Rating
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 (P-I&II) with upto date ammendments. i)Type ii)Make iii)Capacity.
Pdg Hour run meter of recommended make of suitable capacity as per IS:722 (latest edition) i) Type ii) Make iii) Range
Capacitor of Mechell/BHEL/GEC/ L&T make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter/IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB Capacitor i) Type ii) Make iii) Range. 2.00 KVAR
Providing suitable DOL starter of L&T/Hevells/Kilburn make as per IS: 8544-1979 with upto date ammendments for squirrel cage/slip ring motor mounted on panel board with magnetic type overload release and dashpot, time lag, under voltage release with or without initial oil filling as the case mayu be with single phase preventor as per IS 1248 (P-V)-1983 with upto date ammendments. DOL Starter i)Type ii)Make Single phase Preventor i)Type ii)Make
Providing and fixing of double flange Cast steel Sliuce valve of Leader / Kirloskar make for the Delivery pipe and capable of withstanding the normal seat pressure and as per IS 780-1984(Cast Iron) ) with latest ammendments 80mm dia. Class ASA 150
Providing and fixing of double flanged swing type cast steel Reflux valve of Kirloskar/Leader for the Delivery pipe and capable of withstanding the normal seat pressure and s per IS 5312-2004(Cast Iron)with latest ammendments 80mm dia. Class ASA 150
Providing and fixing of double flanged swing type cast steel Reflux valve of Kirloskar/Leader for Rising main and capable of withstanding the normal seat pressure and s per IS 5312-2004(Cast Iron)with latest ammendments 80mm dia. Class ASA 150
Providing 100 mm dia circular dial pressure gauge of Prega/Precision make complete with all accessories such as stop cock, Copper tubing as per IS: 3624-1987 with upto date ammendments. i)Make ii)Range.
Installation of all above items as per the systematic drawing attached with the tender documents or as per the direction of Engineer-in Charge.The contarctor should ensure proper jointing of delivery pipe line of pump with the Rising main including all necessary accessories like increaser /reducer specials etc. as per site conditions and as per direction of the Engineer-in Charge.
Fixing of double flanged GMS piping work(layout to be approved by Engineer-in-Charge) for suction and delivery pipes suitable to pumps offered and common header as per the rising main respectively complete with all specials such as bends,Tees,Reducers Inceasers with companion flanges matching with the relevant specifications of the accessories as indicated in the Drawing i/c rubber/ asbestos gasket of 3 mm thickness as per IS : 2712-1979 and required number of Nuts and Bolts as per 1364-1983.-the pipes shall be as per relevent IS code and to withstand 1.5 times total head. (The pipe shall be issued free of cost at divisional store. However MS flanges will be provided by the firm)
i) Suction Pipe 80 mm dia. GMS Pipe (L)
ii) Delivery Pipe 80 mm dia. GMS Pipe (H) flanged table-17.
iii) Common Header 80 mm dia. GMS (M) flanged table 17 and will extend upto 5 metres from the outer wall of the pump house in the direction of Rising main of 80 mm dia to be joined.
Providing and laying 3 core copper PVC Insulated armoured power cable(One cable carrying all the three phases) of suitable size and capacity to motors and all other elelctrical equipments as per IS: 1554(P-I)1988 or latest with upto date amendments of Seimen/Gloster/IEC/ICC/EICO/National/Grandlay make including all other accessories such as thimble, flelxible pipes, solder, nuts & bolts, cable glands etc. laid in pipes or trenches under floor.
Armoured Power Cable (A) Motor side (From Switch to Starter & Starter to motor) i) Size 2.5 mm2 ii) Make iii)Type iv) Capacity v) Core 3
(B) Supply Side (From meter of HPSEB to Bus Bar & Switch) i) Size 2.5mm2 ii) Make iii) Type iv) Capacity v) Core 3
Providing and fixing double loop earthing with Copper wire/plate 600 mm x 600mm x3.15mm thick electrode complete with material such as thimble, Nuts & Bolts charcoal, salt as per IS:3043-1987 with upto date amenments GI plate & strip of suitable size for motors and other electrical equipments and digging ofpits etc. complete in all respect as per the direction of the Engineer-in-Charge. GI wire SWG-8
SCHEDULE- OPERATION & MAINTENANCE OF SCHEME FOR 5 YEARS
Operation & Maintenace of water supply scheme( all scope as taken in DNIT) i.e. pumping machinery along with allied acessories ie. Starters, pannel boards, valves, Cables, common headers,delivery line , Suction , Pump Houses Cum attendent rooms, Collection tanks, and Treatment plant and Infiltration gallory for five years to be reckoned from the last day of successful trial run period (90 days).
Operation & maintenance for Ist year
Operation & maintenance for 2nd year
Operation & maintenance for 3rd year
Operation & maintenance for 4th year
Operation of maintenance for 5th year
MS Kamal Dev Sharma
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .