Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹74.5 LAccepted-AOC | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹78.3 L+₹2.2 L (2.85%)Rejected-Finance | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹83.0 L+₹6.9 L (9.04%)Rejected-Finance | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹90.9 L+₹14.8 L (19.4%)Rejected-Finance 191 ROHI BHARWARI KAUSHAMBI 212201 | KAUSHAMBI | KAUSHAMBI | UTTAR PRADESH | 212201 | 4 | Rejected-Finance Being other than L-1 |
Tender Value
₹82 L
EMD Value
₹1.5 L
Closing Date
17 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Sharath Ravindran CWE
HQ CWE (AF) Chakeri Pin-208008
UPGRADATION OF SMC AND SHO BLDG AT 24 ED (AF) UNDER AGE (I) MANAURI
2021_MES_492788_1
CA NOCWE(AF)/CHK/MNR/T-32 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
AGE (I) Manauri Prayagraj
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
AGE (I) Manauri
₹1.5 L
15 Feb 2022
6 Dec 2021
20 Jan 2022
6 Dec 2021
17 Jan 2022
30 Dec 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5mtr in depth for foundation, shaft, wells, cesspits, manholes, pier, holes etc and getting out in soft/loose soil, complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified & directed.
Demolition of reinforced cement Concrete of any description and in any position not otherwise specifically provided for including reinforcement cut as required to facilitate demolition, complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars, etc. of any descriptions, keep serviceable bricks in safe custody for re-use, complete all as specified & directed.
M & L Brickwork with fly ash old size bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1: 6 complete all as specified and directed.
Returning & filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/ loose soil, complete all as specified and directed.
Removing excavated material exceeding 250 Mtr but not exceeding 500 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
M & L Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement morter 1:4 finished even & fair complete all as specified and directed.
M & L preparation of new plastered wall surfaces or concrete surfaces and applying two coats of cement base paint over a coat of white cement primer complete all as specified and directed.
M & L preparation of new plastered wall surfaces or concrete surfaces and applying two coats of cement base paint over a coat of white cement primer over 1mm thick Brilacare or JK Putty complete all as specified and directed.
M & L MS work as in framed , joist, channel, angle or tee sections( Fe-410 W or Grade- E-250 quality A) including fixed independently or welding with old frame etc complete all as specified and directed.
Dismantling wall or ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness including snap grid system any type complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) finished even and fair complete all as specified and directed.
M&L RCC M-25 design mix (using 20mm graded stone aggregate) as in slab supported on walls, beams in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L RCC M-25 design mix (using 20mm graded stone aggregate) as in columns, pillar, post, piers, struts complete all as specified and directed.
Use and waste of formwork to sides of columns, pillar, post ,piers, struts finished even and fair complete all as specified and directed.
M&L preparation of existing roof/ chajja's surfaces by cleaning of roof chajja's surfaces free from loose dust / dirt particles or any other foreign materials , vegetation’s etc and applying water proofing treatment with one coat of cold applied polymeric primer @ 0.50 Kg per Sqm and applying a layer of APP based polymeric membrane with gravel /granular finish, not less than 3 mm thick, weighing not less than 3.60Kg/Sqm, reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm). Application of polymeric membrane shall be laid by torch application. Side overlaps shall be 100 mm and at the ends shall be 150 mm and all over laps & joints shall also be sealed by torch application over a coat of hot air blown grade bitumen 85/25 @ 1.2Kg/Sqm complete all as specified and directed.
M&L RCC M-25 design mix (using 20mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5 m span complete all as specified and directed.
S&F 12 mm thick gypsum plastered board flame proof conforming to IS-2095, 1982 fixed/inserted to GI framework with screw, GI frame work, size of grid 605x605mm, for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm center to center /intermediate channel 0.9mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at Approx 900mm center to center with GI cleat and steel expansion fasteners with and including ceiling section (not exc. 1.20 m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm center to center including all hanging materials & two coat of OBD on ceiling surface complete all as specified and directed.
M&L 40 mm thick PCC 1:2:4 type B1 as in floors finished even and smooth with using extra cement as in patches complete all as specified and directed. (NOTE: Glass dividing strip shall be measured and paid separately)
Supply only 3 mm thick and 38 mm wide glass dividing strip complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and removing rubbish off the premises, complete all as specified & directed.
M&L vitrified ceramic tiles of size 10 mm thick area of each tiles exc. 0.36 sqm and not exc 0.42 sqm, laid on floor, jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles, including screed bed or bedding layer 15 mm thick in cement mortar 1:6 complete all as specified & directed.
Taking down Chowkhats or frames not exc 1.5 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed.
Taking down Chowkhats or frames exc 1.5 sqm but not exc 4.0 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed.
Dismantling asbestos cement (corrugated, semi-corrugated, etc) sheets as in roof coverings / valley gutter complete all as specified and directed.
M&L TMT bars 10mm dia dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as above item No 26 but 6 to 8 mm dia TMT bars as in stirrups/spacers etc.
M&L ACP (aluminium composite panel) as in wall cladding of 4mm thick fixed with aluminium beading and aluminium channels, fasteners, cleats angle etc and necessary 'T&P' arrangement of approved colour and shade as approved by AGE (I) complete all as specified and directed.
Complete removal of existing treated surface of walls and applying two coat of oil bound distemper over a coat of alkali resistant primer over 1mm thick Birla care putty or JK putty complete all as specified & directed.
Complete removal of existing treated surface of walls and applying two coat of apex Ultima exterior grade on old walls over a coat of alkali resistant primer over 1mm thick Birla care putty or JK puttycomplete all as specified & directed.
Complete removal of existing treated surface of walls and applying two coat of cement base paint on old walls over a coat of alkali resistant primer over 1mm thick Birla care putty or JK puttycomplete all as specified & directed. (Note for item No 29, 30 & 31: AGE (I)/ Engr incharge will personally get verified that such periodicals items shall not be measured and paid in any other AGe (I) periodicals tenders.
S&F aluminium grill 50 micron powder coated of size 6m dia of aluminium bar mesh size 75mm x 75m and fixed to aluminium window/ ventilator. complete all as specified & directed .
Supply, fabrication and fixing powder coated aluminium sliding window comprising with frame section of size 63x33x2 mm, shutter frame section 110x43x2 mm, side & middle rail of section 83x43x2mm with locking arrangement with lock and self closing device with rebated fixing builders hard wares including provision of 5.5 mm thick tinted or figured glass, glazing clips, rubber beading with roller, locking plate fixed with F channel section 40x18x1.29 mm etc as shown on TD Drg No CE(AF)/NGP/TD/109/2012 sheet No 1/4 to 4/4 complete all as specified and directed.
Taking down cement plaster, any description on brick walls or on concrete surfaces including raking out joints, hacking for key, scrubbing down with water, etc., and removing same from the site(s), complete all as specified & directed.
M & L Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even & fair complete all as specified and directed.
M&L for preparation of newly plastered surface and applying two coat of oil bound distemper, white or tinted over a coat of alkali resistant primer over 1mm thick JK/Birla wall care putty complete all as specified and directed.
M&L cutting & polishing of existing Kota stone flooring of any conditions oily/ reasee surface or yellow shade surface by applying 3 coat of cutting by 75 No, 100 Nos & 200 Nos stone chips through cutting machine and preparing surface of kota stone floor with bee wax shining as with mirror polishing complete all as specified & directed .
M&L for precast cement concrete louvres and jallies, 40mm thick (measured solid) type B-0 (1:2:4) set in cement mortar 1:4 including all mouldings complete all as specified and directed.
Taking down shutters of any description not exc 1.0 sqm each complete all as specified and directed.
Taking down shutters of any description exc 1.0 sqm but not exc 2.0 sqm each complete all as specified and directed.
S & F 2nd Class, hard wood SAL or BEJASAL Plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
S&F factory made, 32mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F of frame work such as grill gratings, etc with ends of bars shouldered and or riveted or welding, forged into spike; framed guard bar barred iron doors incl necessary hinges, pintle hinges, stops handle made sliding bolt etc complete all as specified & directed.
S&F Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
M&L PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in fixing of hold fast complete all as specified & directed.
S&F Butt hinges, medium weight, cold rolled mild steel, of size 100mm long complete all as specified and directed.
S&F aluminium anodised, barrel tower bolts of size 150 mm long of extruded section complete all as specified and directed.
S&F aluminium anodised, handle of size 150 mm long of extruded section complete all as specified and directed.
S&F aluminium alloy, anodised, sliding door bolt of size 250mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy complete all as specified and directed.
S&F 3.5mm thick sheet glass plain, ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and directed.
S&F Mild steel 300mm long , ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
M&L preparing new or previously untreated surface of wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint (first quality) over a coat of red oxide primer complete all as specified and directed.
S&F in repair mild steel chromium plated curtain rod 20mm dia fancy type including decorative brackets, round corner and rings complete all as specified & directed.
Supply only 10 ltr capacity PVC low level flushing cistern complete with siphon handle lever float valve and PVC bend incl connecting to ITWC/ ETWC and fixing on wall bracket complete all as specified & directed.
S&F in repairs vitreous china water closet (pedestal pan) coloured complete with fixing of low level 10 ltr capacity PVC, valve less, symphonic action and white seat cover (PVC) with flat recessed bottom with chromium plated or aluminized hinges devices complete all as specified & directed. (Note: Coloured PVC flushing cistern will be measured and paid separately under respective items).
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed.
E/M WORKS Taking down carefully point wiring from existing place (light/fan/bell point, socket or power points etc complete) with all fittings such as switches, sockets , ceiling rose, pendant holder, light fitting and fixtures , call bell etc and making good to disturbed surface of wall ,floor etc to match with existing surface with cement mortar 1:3 or plaster of peris etc and to match / finish new surface as the existing surface either by using same colour distemper over putty or white/ colour wash as required complete all as specified and directed.(Note: Point wiring on same board shall not be considered for taking down).
M & L concealed point wiring on wall and surface wiring on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including PVC conduit, ISI marked, not less than 20 mm dia, medium grade with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly covered with bakelite laminated sheet 3mm thick, ISI marked for mounting of switches / sockets, fan regulators with brass screw and cup washers including PVC-FRLS insulated and unsheathed copper multistrand conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing complete all as specified and directed for the following :- (a) One light /fan point, controlled by one, one way switch
(b) All as per item No (60) above but one 5/6 Amp socket on the same board with other switch.
(c) as per item No (60) above but one 5/6 Amp socket on independent board.
(d) All as per item No (60) above butOne 3 pin, 15 Amp, socket, independent but with 2.5 sq mm FRLS - PVC insulated unsheathed copper stranded conductor and earth wire with 2.5 sqmm PVC FRLS insulated, unsheathed copper stranded conductor
(e) All as per item No (60) above but one 3 pin, 15 Amp, socket, independent but with 4.0 sq mm FRLS - PVC insulated unsheathed copper stranded conductor and earth wire with 4.0 sqmm PVC FRLS insulated, unsheathed copper stranded conductor multi stranded 1100 volts grade cable as continuous earth lead complete.
Supply and fixing modular switch, one way 6 Amps 1 module complete all as specified and directed. (Note for item No 61 to 76: Colour / model of modular accessories shall be approved by AGE (I)).
Supply and fixing modular switch, one way 16 Amps 1 module complete all as specified and directed.
Supply and fixing modular bell push 6 Amps 1 module complete all as specified and directed.
Supply and fixing modular socket 6 A, 2/3 pin combined 2 module complete all as specified and directed.
Supply and fixing modular socket 16 A, 3/5 pin combined 2 module complete all as specified and directed.
Supply and fixing modular type power unit single phase 220 volts 32 Amps socket and control switch ISI marked 3 module complete all as specified and directed.
Supply and fixing bell musical of approved quality, AC 230 volts single pole complete all as specified and directed.
Supply and fixing ceiling rose surface type 65 MM x 50 MM, 2 to 3 terminal complete all as specified and directed.
Supply and fixing modular fan regulator electrinic five step type 120W 2 module complete all as specified and directed.
Supply and fixing Telephone sockets 2 Pin modular type complete all as specified and directed.
Supply and fixing TV plug sockets 2 Pin modular type complete all as specified and directed.
Supply and fixing white cover plate with frame 2 module complete all as specified and directed.
Supply and fixing white cover plate with frame 3 module complete all as specified and directed.
Supply and fixing white cover plate with frame 4 module complete all as specified and directed.
Supply and fixing white cover plate with frame 6 module complete all as specified and directed.
Supply and fixing white cover plate with frame 8 module complete all as specified and directed. (Note for item No 61 to 76 ): Quoted rates shall be included cost of blanking plate required to cover the gap of modular sockets opening plate.
Supply and laid concealed in surface of wall PVC conduit medium grade heavy duty 25 mm minimum for telephone and TV cable etc complete all as specified and directed. (Note:- Quoted rate shall be included cost of cutting, chasing, plastering, cololuring etc to surface wall/ beam/ roof etc as per site requirement matching with existing surface complete).
Supply and fixing LED recessed mounted 2x2 luminaire LED 36 W light fitting energy saving low glare high power suitable for use in false ceiling with inbuilt SS clip arrangement / screws for fixing etc incl making all electric connection using three core copper cable drawn through in PVC flexible conduit pipe from ceiling rose to fittings including taking out to unsv old fittings complete all as specified and directed. (Make: Philips full glow series RC 380B LED 36- 6500 G 4 L 60 W 60 PSU OD (HSN code 6405) Bajaj SKYLUX LED Cat No BZRSQL 36W GZ1 CW or Crompton or equivalent make in Appx 'B' make & manufactures)
Supply and fixing LED recessed mounted down 12 W light fitting energy saving low glare high power mounting on PVC round/ square block on surface of wall / beam etc incl making all electric connection using three core copper cable drawn through in PVC flexible conduit pipe from ceiling rose to fittings including taking out to unsv old fittings complete all as specified and directed. (Make: Philips (Green LED I) cat No DN 193B LED 12S-3000 PSU WH S2 or make Bajaj Cat No (AMERIS LED) Cat No BXTAR 30W LED WH or Crompton equivalent make in Appx 'B' make & manufactures)
Supply and fixing LED light fitting with frame, driver etc in 20 W 4 feet long white colour mounting on tow Nos of PVC round/ square block on surface of wall / beam etc incl making all electric connection using three core copper cable drawn through in PVC flexible conduit pipe from ceiling rose to fittings including taking out to unsv old fittings complete all as specified and directed. (Make: Philips (Smart bright series) BN 020 LED 25S 6500 PSU GR S1 or Bajaj (flexitron LED) BLTRU 20W NW VIVA or Crompton equivalent make in Appx 'B' make & manufactures) (for un-ceiling covered area)
Supply and fixing LED tube light fitting with frame, driver etc in 10 W 2 feet long white colour mounting on tow Nos of PVC round/ squire block on surface of wall / beam etc incl making all electric connection using three core copper cable drawn through in PVC flexible conduit pipe from ceiling rose to fittings including taking out to unsv old fittings complete all as specified and directed. (Make: Bajaj cat No BCLSB 10W NW or Philips or Crompton equivalent make in Appx 'B' make & manufactures)
Supply and fixing angular base plate type PVC holder with 10 W LED LED bulb in given colour incl making all electric connection using three core copper cable drawn through in PVC flexible conduit pipe from ceiling rose to fittings including taking out to unsv old fittings complete all as specified and directed. (Make: Bajaj / Havells or Crompton equivalent make in Appx 'B' make & manufactures)
Supply and fixing LED street/ Bldg security light fittings 45 watts energy saving incl making all electric connection using three core copper cable drawn through in PVC flexible conduit pipe from ceiling rose to fittings and mounting bracket made out by GI pipe light grade in 25 mm dia of bore in required length bend in 120 degree fixed with clamp made out by GI strip in size 32 x4 mm using nut bolt and washer etc complete all as specified and directed. (Make: Bajaj Cat No BRTFG 45 W LED V3 WW/ Philips/ Crompton or equivalent make in Appx 'B' make & manufactures) Note:- Three core copper cable used for making connection from ceiling rose deemed to be included in quoted unit rate.
M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 10.0 sqmm drawn in and including rigid, non metallic, white ivory, PVC conduit of suitable dia medium grade, ISI marked in concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddles, pipe hooks etc fixed properly on as in concealed position incl cutting chasing & making good to disturbed surfaces & matching with the existing colour of wall/floor etc including one single core 10.0 Sqmm PVC-FRLS insulated unsheathed multistranded copper conductor as a continuous earth wire in conduit including taking down old unserviceable sub main wiring with existing conduit complete all as specified and directed.
M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6.0 sqmm drawn in and including rigid, non metallic, white ivory, PVC conduit of suitable dia medium grade, ISI marked in concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddles, pipe hooks etc fixed properly on as in concealed position incl cutting chasing & making good to disturbed surfaces & matching with the existing colour of wall/floor etc including one single core 6.0 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire in conduit including taking down old unserviceable sub main wiring with existing conduit complete all as specified and directed.
M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid, non metallic, white ivory, PVC conduit of suitable dia medium grade, ISI marked in concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddles, pipe hooks etc fixed properly on as in concealed position incl cutting chasing & making good to disturbed surfaces & matching with the existing colour of wall/floor etc including one single core 4.0 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire in conduit including taking down old unserviceable sub main wiring with existing conduit complete all as specified and directed. (Note for item No 84 to 86 : Three run of single core cable of respective size and one run of PVC conduit shall be measured and paid as one unit length).
Supply and fix sheet metal enclosure distribution board TPN, 4 poles ,double door, 4 way with 200 Amps rated copper bus bar vertical type with MCCB 4 pole 100 Amps 415 volt thermal magnetic base operated as incomer incl concealed in surface of wall and making all connection using gland , thembles in required size including taking down to old unsv DBs in any make/ model/ way etc with accessories complete all as specified and directed (Note: Quoted rate shall be included cost of MCCB , cutting plastering , colouring to surface of wall to be concealed etc all site required matching with existing surface). (Make: Legrand/ Siemens or L&T or equivalent make in Appx 'B' make & manufactures)
Supply and fix sheet metal enclosure for MCB distribution board SPN, double door, 8 way with 200 Amp rated bus bar 230 Volts including taking down to old unsv DBs in any make/ model/ way etc with accessories complete all as specified and directed.
Supply and fix sheet metal enclosure for MCB distribution board SPN, double door, 4 way with 200 Amp rated bus bar 230 Volts including taking down to old unsv DBs in any make/ model/ way etc with accessories complete all as specified and directed.
S&F to MCCB , 415 volt TPN 4 poles 63 Amps ,16 KA breaking capacity, thermal based adjustable type complete all as specified and directed
Supply and fixing MCB , SPN, 2 pole 220 volts , 63 Amps , "C" Curve 10 KA complete all as specified and directed
Supply and fixing MCB , SPN, 2 pole 220 volts , 40 Amps , "C" Curve 10 KA complete all as specified and directed
Supply and fixing MCB , single pole 215 volts , 32 Amps , "C" Curve 10 KA complete all as specified and directed
Supply and fixing ceiling fan in size 1200 MM sweep white colour 5 star rated copper wound energy saving with set of sweep/ extension rod / "U" clamp and other accessories single phase 50 Hzs incl making electric connection using three core copper cable drawn through in PVC flexible conduit pipe complete all as specified and directed. Make : Usha model EX 3, 1200 MM (white colour) or equivalent make as approved by AGE from Appx 'B' list of make & manufactures)
Supply and fixing of wall mounting fan/ air circulators heavy duty 450 MM sweep non capacitor bracket mounted type copper wound motor ISI marked 3 star rated energy saving with fixing accessories complete making necessary electric connection allas complete all as specified and directed. (Make: Usha model MAX Air W/F (white colour) or equivalent make as approved by AGE from Appx 'B' list of make & manufactures)
Supply and fixing as new exhaust fan 300 MM sweep steel body heavy duty with louver mounting bracket ISI marked 4 star rated energy saving less noise capacitor type incl making hole in brick wall plastering colour coding and all site required work for disturbed surface matching with existing and making electric connection using three core copper cable drawn through in PVC conduit pipe complete all as specified and directed. (Make : Crompton Greaves / Havells Sahas) (SI 300-6P) (for toilet)
M&L in replacement earthing complete with galvanized steel earth plate 600 x600 x 6mm thick, buried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtrs below normal ground level, connected to galvanized GI strip 32 x 6 MM as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints including excavation and earth work, GI pipe light grade 40 MM bore for protection of GI strip from earth electrode and 15 MM as watering with wire mesh funnel charcoal dust, common salt, PCC (1:2:4) type B-1 using 20 MM graded stone aggregate for chamber and MS angle iron frame 40x40x3 MM and RCC cover 40 MM thick (1:2:4) type B-1 using 20 MM graded stone aggregate reinforced with 6 MM dia round bars @ 75 MM C/C both ways with MS handle 12 MM dia , PGI funnel and wire mesh , 20 MM bore GI Pipe light grade for watering complete all as shown in electrical plate No 3 of SSR Part-I(2009) and connected to earth test point including testing complete all as specified and directed. (Note: (i) Earthing strip and protection pipe upto 7.5 metre length shall be deemed to be included in the quoted unit rate. Earthing strip beyond 7.5 metre shall be measured and paid for separately. (ii) Payment shall be made only after getting the earth resistance value within standard limit.
M&L earthing complete with galvanised steel earth electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth electrode not less than 1.5 mtr below normal ground level, connected to galvanised iron wire 4mm as earth wire by means of bolt, check nuts & washer of GI or steel connected to earth test point including earth strip from earth electrode to test point, Gl pipe 20 mm dia light grade as protection pipe and 20mm dia GI pipe light grade for watering pipe of required length including charcoal dust, common, salt, excavation and earth work, earth pit with PCC 1:3:6 type C 1 using 20mm graded stone aggregate, precast RCC cover 40mm thickness reinforced with 03 Nos TMT bars, 8 mm dia, both ways, funnel with wire mesh, testing and rest as shown in electrical plate No 3 of SSR Part -I including taking out old earthing material, complete all as specified and directed. Note:- Payment shall be made only after getting the earth resistance value within standard limit.
Supply & filling of sand cushioning (dry sand) free from impurities or vegetable grass in under ground cables for cable protection in layer of 8 cm deep before laying of cable and 15 cm depth after laying the cable, complete all as specified and directed. (NOTE : Punned thickness of sand layers shall be measured and paid .)
M&L sub class B bricks old size well burnt, laid dry flat in trenches for protection of cable over LT/HT cable complete all as specified and directed.
Boring of holes under road/drain/PCC path by manual method for inserting upto 150 mm dia of bore pipe /GI tubing for cable protection complete all as specified and directed. (NOTE: Depth of bore shall not be more than 1.5m below natural Ground level.)
Supply and fixing to 80mm bore, galvanised steel tube, light grade with and including all fittings accessories such as clamp etc laid in trenches, under road crossing, fixed on poles/walls for cable protection complete all as specified and directed.
All as per item No 102 above but size 50mm bore, galvanised steel tube, light grade.
All as per item No 102 above but size 40mm bore, galvanised steel tube, light grade.
S&F flood light fitting LED 160 W with fixing accessories ,mounting bracket nut bolt washer to be fix on top edge of high mast tower / steel structure as site with making all connection using three core flexible copper cable in size 2.5 Sqmm drawn through in PVC conduit medium grade heavy duty pipe with accessories fixed inside the tower from MCB in control box for each light fittings (minimum 18 RM Cable length with each fittings)complete all as directed. Note ; Quoted rate shall be included the cost of copper cable , PVC conduit and fixing accessories etc all as site required complete. (Make:- Bajaj (Turbo) cat No BARFEG 160 W LED in equivalent Wipro/ Philips in other makes as per list of make & manufactures approved by AGE (I))
Supply, laying, jointing, testing & commissioning in trances/ fixing with pole/ connecting, thembling, glanding of XLPE insulated under ground screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core (earthed) including taking down existing cable complete all as specified and directed. (NOTE: Excavation & earth work, sand cushioning, brick protection shall be measured and paid under respective items)
All as per item No-106 here-in-above but of size 95.00 Sqmm 3.5 core (earthed).
All as per item No-106 here-in-above but of size 50.00 Sqmm 3.5 core (earthed).
All as per item No-106 here-in-above but of size 35.00 Sqmm 3.5 core (earthed).
All as per item No-106 here-in-above but of size 10.00 Sqmm 2.0 core (earthed).
M&L in replacement earthing complete with galvanized steel earth plate 600 x600 x 6mm thick, buried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtrs below normal ground level, connected to galvanized GI strip 25 x 4 MM as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints including excavation and earth work, GI pipe light grade 40 MM bore for protection of GI strip from earth electrode and 15 MM as watering with wire mesh funnel charcoal dust, common salt, PCC (1:2:4) type B-1 using 20 MM graded stone aggregate for chamber and MS angle iron frame 40x40x3 MM and RCC cover 40 MM thick (1:2:4) type B-1 using 20 MM graded stone aggregate reinforced with 6 MM dia round bars @ 75 MM C/C both ways with MS handle 12 MM dia , PGI funnel and wire mesh , 20 MM bore GI Pipe light grade for watering complete all as shown in electrical plate No 3 of SSR Part-I(2009) and connected to earth test point including testing complete all as specified and directed. (Note: Earthing strip and protection pipe upto 7.5 metre length shall be deemed to be included in the quoted unit rate. Earthing strip beyond 7.5 metre shall be measured and paid for separately).
Supply, Installing, testing and commissioning of LT Panel in cubical housing cabinet, out door type, platform mounted (minimum height 45 CM above normal GL and 30 CM below normal GL) , CPRI approved factory made totally enclosed dust and vermin proof made out by 3.15 MM thick CRCA MS sheet of overall indicating size 1200mm x 900mm x 450mm and full built upon angle iron frame in size 40 x 40 x 6 mm having front and rear hinged both side openable doors and lifting lugs (02 Nos) locking arrangement to be connect to earthing strip at rear side, bottom detachable both side openable ,gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers sheet steel bus bar chambers having front hinged covers with a set of electrolytic grade high conductivity. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment. The panel shall be epoxy powder coated and the control circuit shall be connected by multi stranded copper conductor flexible wire 1.5 Sqmm in proper colour coding and drawn through in flexible conduit. The panel should be suitable for 415 volts ,50 Hzs, 3 phase wire system ,suitable rating CTs and PTs . internal connection should be made by copper strip in suitable rating ,making incoming and outgoing connection using gland in suitable size including grouting KIOSK on floor (60 CM above the ground surface) in floor angel iron 50 x 6 MM imbedded to fixed the KIOSK with nut bolt, floor PCC (1:2:4) type B1 using 20 MM grade stone aggregate ( minimum 50 CM above GL and 30CM below GL) including name plates/ danger plates & other configuration of cross bone / danger identification & lugs etc complete comprising the following items:- Note : (i) Panel drawing shall be approved by Deptt for size/ qty/ Tech specification before placing order (ii) All MCCB shall be confirming to Icu 100% and IEC 60947 -2. in compact series of same make (Make for MCCB : Schneider / Legrand/ Siemens) (a) 04 Nos bus bars equal size made out of aluminium conductor strip in colour coating 600 Amps rated mounting on both side heat to shrinkable insulators and PVC sleeve. -01 Set (b) LED indicating lamps of 'R' 'Y' and 'B' phase. (Set of three -01) (c) Digital volts meter rating 3 phase class 1 - 01 No (Make :- L&T or equivalent) (d) Digital Ammeter rating 3 phase 1A class 1 - 01 No (Make :- L&T or equivalent) (e) INCOMING: MCCB , 160 Amps rated, 4 pole, TPN, 415 volts grade , 36 KA breaking capacity Thermal/Magnetic based operated - 02 Nos (As main incoming+ 01 stand by) (f) OUTGOING: MCCB ,63 Amps rated, 4 pole, TPN, 415 volts grade , 16 KA breaking capacity thermal magnetic based operated - 04 Nos (Out going each TPN DB ) (g) MCCB 40 Amps rated 4 pole TPN 415 volts grade 16 KA Thermal magnetic based - 03 Nos (as outgoing) (h) MCB 63 Amps rated 4 pole TPN 415 volts grade 10 KA Thermal magnetic based - 04 Nos (for security and out fit area light) (i) Off load change over switch 4 pole TPN 415 volts 200 amp rated - 01 No
Supply & fixing GI strip of size 32x6mm buried in trances/ fixing with pole/ walls etc complete all as specified and directed.
Supply & fixing GI strip of size 25x4mm buried in trances/ fixing with pole/ walls etc complete all as specified and directed.
S&F water heater storage type 5 star rating energy efficient, electrical operated , capacity 25 liters with inner copper tank, thermostat etc complete incl making good the disturbed surface complete all as specified and directed. Make : Havells/Racold/Crompton
S&F steel water tubing 15mm dia (Bore), galvanised, ‘medium grade’ with all fittings, fixed on walls, ceiling or laid in floors or any other situation with fittings and connections, etc., complete all as specified & directed.
S&F steel water tubing 20mm dia (Bore), galvanised, ‘medium grade’ with all fittings, fixed on walls, ceiling or laid in floors or any other situation with fittings and connections, etc., complete all as specified & directed.
S&F Gun metal gate valve or globe valves, ISI marked of 15mm dia/ bore with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S&F in repair 15mm bore bib tap cast copper alloy with crutch or butterfly handels screwed down for iron pipes or for brass ferrule complete all as specified & directed.
Supply installation connecting and commissioning of water cooler fully satin less steel, electric driven steel electric driven single phase 240 Volt 50 Hzs having storage 40 Ltrs and normal cooling capacity 80 Ltrs per Hours in latest features energy saving 4 star rated with two (02) year warranty including with fully automatic servo control voltage stabilizer wall mounted in capacity 2 KVA single phase 220 volts making with electric connection using three core copper cable in required length and water connection using flexible inter connection pipe in 20 MM dia both side sockets complete all as specified and directed. (Make: Voltas/Samsung/Usha)
Supply installation connecting to water dispenser in latest features as air press sensor based touch less operation suitable for hot, cold (02) year warranty, cold storage 3.5 Ltrs cooing capacity 3 (Three) LPH hoting capacity of water 6 Ltr single phase 220 Volt 500 W including making all connection for electric using 3 core X 2.5 Sqmm copper cable in suitable length and water connection using 01 Nos gate valve in 15 MM dia bras single cutting threading etc all as site required including flexible inter connection pipe with both side sockets etc all as site required work required to be made serviceable including with dully automatic servo control voltage stabilizer wall mounted in capacity 2 KVA single phase 220 volts making with all connection complete all as specified and directed. (Note:- (i) Quoted rate shall be included the cost of all accessories such as Gate valve & connection pipe. (ii) Cost of Voltage stabilizer deemed to be included in quoted unit rate.)
Labour for removing to existed Geyser in all types make model etc safely with all connection pipe and accessories and taken over in safe custody for re-using to same on given site including re-fixing/ connecting and making connection as per existing electric fixtures making all connection using PVC insulated three core copper cable in size 4 Sqmm x three core with 20 Amps modular top plug and making water connection using interconnection wire meshed flexible pipe in 60 CM long both side end sockets including required nut in 12 MM dia 63 MM long 04 Nos grouting in surface of wall to be hanging complete all as specified and directed. (Note : Quoted rates shall be included the cost of inter connection pipe, cable with top plug, nuts (04 Nos) minimum etc all other required to make serviceable).
M&L for painting to body of Geyser in all type and specifications in two coats, one as finishing over one coat of red primer after removing to old faded paint scrabing washing with soda water filling to putty/filler in cavities and making mark as per existed using different colour including re-fixing using nut bolt and washer complete all as specified and directed.
Labour for removing to existed water cooler/split or window AC in all types make model capacity etc safely after removing all connection pipe and connection accessories such as voltage stabilizer copper air tube, out door and indoor unit etc others and taken over in safe custody for re-using to same on given site including re-using/installation/ connecting/testing and making connection as per existing and site required work such as servicing cleaning newly fix condenser/split AC out door unit mounting steel Quoted rates shall be including the cost of inter connection copper cable, cooper air tube required to be made air connection of split ACs in site required length/dia with lagging / GI mounting brackets/nut bolt washers etc complete all as specified and directed.
Supply and fixing refrigerator 4 star rated inverter insisted capacity 284 Ltrs gross volume, storage volume 259 Ltrs double door frost free puff insulation copper coil complete with making connection including fully automatic servo control voltage stabilizer wall mounted in capacity 2 KVA single phase 220 volts making with all connection complete all as specified and directed. (Make:- LG model GL-1302RPZL/2017 or equivalent in Samsung/Whirlpool (for Refrigerator) and Microtek/Blue star (voltage stabilizer) Note:- Cost of Voltage stabilizer deemed to be included in quoted unit rate.
Supply, install, fixing and commissioning split type air conditioner copper of capacity 2.0 TR, five (5) star BEE rated all weather type suitable for cooling and heating with cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, star rated cooling capacity 7034 W, EER 4.7 W/W remote control suitable for wall mounted, single phase, 230/250 volt in built AC digital inverter including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing after commissioning, making necessary connections unplasticised PVC pipes medium duty 20 MM dia for drainage out condensed water all as required including necessary connection through wall for mounting voltage stabilizer copper wound for fully automatic operation single phase naturally air cooled indoor type and designed for input voltage between 140 to 280 volts with output voltage stabilized at 230 V+/- 2.5% with time delay relay and suitable for fixing/ mounting on wall of capacity 5 KVA complete all as specified and directed. (Make: Hitachi model RMRG 524 HEEA/2021 white or in equivalent Voltas ( for AC) and (Make:- Mircotek/ volina/ Blue star (for voltage stabilizer) (Note: (i) Quoted rates shall be included cost of out door mounting bracket, voltage stabilizer, required copper tube in various size, water drain out pipe, hole in brick wall etc all as site required to make serviceable). Note:- Cost of Voltage stabilizer deemed to be included in quoted unit rate.
Supply, install, fixing and commissioning split type air conditioner copper of capacity 2.0 TR, five (5) star BEE rated with cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, star rated cooling capacity 7034 W, EER 4.7 W/W remote control suitable for wall mounted, single phase, 230/250 volt in built AC digital inverter including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing after commissioning, making necessary connections unplasticised PVC pipes medium duty 20 MM dia for drainage out condensed water all as required including necessary connection through making necessary connections through wall for mounting voltage stabilizer copper wound for fully automatic operation single phase naturally air cooled indoor type and designed for input voltage between 140 to 280 volts with output voltage stabilized at 230 V+/- 2.5% with time delay relay and suitable for fixing/ mounting on wall of capacity 5 KVA complete all as specified and directed. (Make: Blue star, model IC 524 DA TX Alloy condenser (white) or in equivalent Voltas (for AC) and (Make: Microtek/ Volina/ Blue star (for voltage stabilizer) (Note: (i) Quoted rates shall be included cost of out door mounting bracket, voltage stabilizer, required copper tube in various size, water drain out pipe, hole in brick wall etc all as site required to made serviceable).Note:- Cost of Voltage stabilizer deemed to be included in quoted unit rate.
Labour for cutting welding threading etc all to existed pipe line in all dia/make / working pressure for taking up new connection including fitting such as “T” elbow sockets T pieces in required dia and medium grade etc as site required including earth work /PCC and brick work on requirement complete and directed.
Supply, installation, commissioning and testing of diesel engine driven factory assembled, floor mounted ,silent type diesel generating set of capacity 100 KVA (80 KW), at 0.8 power factor or nearest higher size , 3 phase, 4 wire, 50 Hz, 415 Volts 1500 RPM as per IS 10001/10002 complete with safety contact and metering equipment mounted on common base frame on PCC platform with anti-vibration pads as recommended by manufacturer including AMF panel of suitable capacity from DG set manufacturer’s with all fixing arrangement complete all as specified, directed and comprising the following:-
(A) PRIME MOVER : Prime mover directly coupled with water cooled engine suitably rated matching BHP for driving 100 KVA (80 KW) capacity alternator, 1500 RPM , electric-start four stroke diesel engine confirming to ISO -3046/ BS- 5514 and IS 10001/10002 for continuous running and capable for taking 10% over load for one hour for every 12 hours with the following accessories:-
(i) Heavy duty radiator
(ii) Radiator fan and fan drive
(iii) Fly wheel with housing
(iv) Thermostat controlled cooling system
(v) Cooling water centrifugal/ gear type pump
(vi) One Number silencer (residential type)
(vii) Rotary fuel injection pump
(viii) Spin on type fuel filter
(ix) Fuel pre filter
(x) Lubrication oil pump with coolent
(xi) Spin on type lubrication oil fuel filter
(xii) Standard air cleaner with replaceable paper element
(xiii) Fuel injection pump/PT pump with mechanical/ electronic governer class G-2
(xiv) Exhaust Manifold
(xv) 12 volt electrical system with engine starter motor and battery charging alternator.
(xvi) Safety switches for high water temperature low lubrication oil pressure and engine over speed.
(xvii) 12 volt stop solenoid energized to run.
(xviii) User hand book
(xix) Maintenance free battery, of appropiate AH value as per OEM recommendations -01 No 12 volt along with battery lead copper and connector.
(xx) Battery mounting rack as per OEM recommendations. -01 No made out of MS angle iron 40mm x40mm x5mm & 150 high
(xxi) Daily services fuel tank suitable for full load running of DG set for min 8 hours enclosed within the canopy all as per CPCB norms with level indicator inlet, fuel outlet, drain plug, air vent and locking arrangement etc including fuel pipe connections with connected GI pipe medium grade connector from fuel tank to the DG set and over flow from the DG set to fuel tank complete with gun metal gate valve.
(xxii) Standard safety device and self starter 12 volts DC
(xxiii) Heavy duty base frame of sturdy design made of MS stud with necessary reinforcement and lifting arrangements.
(xxiv) Set of specially designed AVM pads between the engine alternator feet and the base frame.
(xxv) Exhaust system shall be provided with thermal insulator by using fire retardant / non igniting foam conforming to ISO 3046/ BS-5514 to prevent excess heat radiation on the engine and safe for operator. (xxvi) Flexible coupling with guards.
(B) Repair Tools:- Following set of tools shall be provided alongwith DG Set. (i) Set of DE spanner – 6 – 32 mm - 1 set (ii) Insulated cutting plier 250mm - 1 No (iii) Adjustable spanner 300mm - 1 No (iv) Screw driver 300 mm long - 1 No (v) Screw driver 100mm long - 1 No (vi) Ring spanner set – 6mm to 32mm - 1 Set of 10. (vii) Allen key set - 1 Set (1.5mm to 10mm) (viii) Cell tester - 1 No (ix) Hydrometer - 1 No (x) Tool box-01 N0
(C) ACOUSTIC ENCLOSURE : Floor mounted Accoustic enclosure (canopy) suitable for 100 KVA DG set as per CPCB norms of the make as that of DG set to be provided with following provisions/ specifications:- (i) The enclosure fabricated out of 1.2 mm thick CRCA sheet suitable to accommodate the DG set properly. (ii) The sheet metal components are Hot dip seven tank pretreated. (iii) It is purepolyster based powder coated(inside as well as outside). All nuts / bolts / hardware are zinc coated with salt spray test as per ASTMB-117.` (iv) Baterry is accommodated in a tray in the enclosure. (v) The doors are fitted with gasket with high quality EPON gasketed to avoid leakage of sound. (vi) Sound proofing of enclosure is done with high density fire retardant PU foam 50mm thickness of density 32 Kg / Cum in accoustic enclosure. (vii) Special residential silencer is provided within enclosure to control exhaust noise. (viii) Specially designed alternators are provided to control sound at air entry to the container and exhaust from container. (ix) Adequate ventilation is provided to meet requirement for combustion and heat removal. If required a blower is used to meet total air requirement and air changes. (x) Temperature of enclosure does not exceed beyond 50 degree C of ambient temperature. (xi) The enclosure is provided with 'High enclosure temperature safety device'. (xii) There is provision of emergency shut down from outside the enclosure. (xiii) There is arrangement of proper illumination inside the canopy. (xiv) Noise level is 75DB (A) at 1 mtr distance. (xv) Approved by CPCB.
(D) ALTERNATOR : Alternator 100 KVA (80KW) at 0.8 Power factor self regulated, three phase 4 wire system with neutral, 415 volts, 50 Hz, 1500 RPM conforming to BS 2613/IS-4722 complete with automatic voltage regulator. (i) The alternator shall be self excited self regulated and foot mounted fitted with ball and or roller bearing including making cable connections. The alternator will be suitable for tropical climate. The excitation system consists of an electronic automatic regulator having very fast response to load changes. The silent features of alternator are:- (i) ( + ) or ( - ) 1% voltage regulation under static conditions (ii) Class H insulation (iii) Permanently lubricating bearing (iv) 10% over load allowed for one hour for every 12 hour
(E) AMF CONTROL PANEL SUITABLE FOR 100 KVA DG SET :- Supply, installation and Testing of Automatic main failure panel mounted inside accoustic enclosure, ( Microprocessor Based AMF Controller cum engine control unit with inbuilt timer, counters complete with accessories & relay) internal wiring with copper wire of suitable rating fabricated with 16 SWG CRCA sheet & its base frame with powder coated paints and comprising with following :- (1) MCCB & MCBs of suitable rating as per OEMs recommendation. (2) Power Contactors rating as per OEMs recommendation (3) Aluminium bus Bar as per OEMs recommendations - 01 Sets (4) SMPS battery charger -01 No Note :- AMF panel shall be mounted inside the acoustic enclosure and shall be installed by OEM of DG set.
Note:- (i) The engine of DG set shall be suitable design to suit the climatic condition of Manauri, Allahabad so as to give desired output including 10% over load. (ii) The quoted rate for DG set is inclusive of PCC foundation. The foundation for DG set should be made of PCC 1:2:4 type B-1 using 20mm graded stone aggregate below the ground level minimum 300mm and 200mm above ground level. The size of platform shall be as per manufacturers recommondations including mounting with suitable fastner/ nut/ bolts etc complete all as specified and directed. (iii) The DG set shall be suitable for auto main failure function. (iv) The DHPP (fuel) required for testing of DG sets is deemed to be included in above quoted rate. (v) AMF panel should be prefitted by OEM of DG Set only. (vi) Phase-I test will be carried out by Engineer-in-Charge for no load for 1 hour and 100% load for 01 hour each and Phase-II test will be carried out in presence of rep of Accepting officer for no load, 25%, 50%, 75%, 100% for 11 hours and 110% for 1 hour over load. (vii) DG Set shall be composite type with AMF panel, Prime mover, alternator and allied accesories in one enclosure. (viii) Arrangement of dummy load deemed to be included in quoted unit rate.
VINAYAKA (INDIA) MULTIFARIOUS SERVICES PVT LTD
M/S Garg Sons
Z N Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .