Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 LAdmitted-Finance | ₹4.1 L | L1 | Admitted-Finance |
| 2 | L2₹4.2 L+₹8,400 (2.06%)Admitted-Finance ROPAR ROAD NALAGARH TEHSIL NALAGARH DISTRICT SOLAN HP | ₹4.2 L+₹8,400 (2.06%) | L2 | Admitted-Finance |
| 3 | L3₹5.6 L+₹1.5 L (36.6%)Admitted-Finance CHENAB VALLEY DIVISION HPPWD UDAIPUR HIMACHAL PRADESH | CHAMBA | HIMACHAL PRADESH | 176207 | ₹5.6 L+₹1.5 L (36.6%) | L3 | Admitted-Finance |
| 4 | L4₹6.7 L+₹2.6 L (63.9%)Admitted-Finance | ₹6.7 L+₹2.6 L (63.9%) | L4 | Admitted-Finance |
| 5 | L5₹8.0 L+₹3.9 L (95.9%)Admitted-Finance | ₹8.0 L+₹3.9 L (95.9%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SACHN KUMAR L1 | GREWALSUBMERSIBLE AND ELECTRICAL SERVICE L2 | M/S SANTOKH SINGH ELECTRICAL WORKS L5 | Jashwant Singh L4 | LALIT KUMAR L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, erection, testing & commissioning of submersible pumping of reputed make such as BS/ KSB/ Sabar,Johnston/Worthington conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having Charctorstics as mentioned in item No. 1 (a)greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:- | 1 | Set | 4,00,000 ₹4,00,000 | 3,95,000 ₹3,95,000 Lowest | 7,70,000 ₹7,70,000 | 6,58,000 ₹6,58,000 | 5,52,000 ₹5,52,000 |
| 1.01Total Head in mtrs (i/c depth of Column Pipe in case of Bore Well) : 85 Mtrs. | ||||||||
| 1.02Discharge:- (in LPS) of each pump : 40 Lps. | ||||||||
| 1.03Dia of Rising main (in mm) : 250 mm | ||||||||
| 1.04Dia of Column Pipe (in mm):- 200 mm | ||||||||
| 2.00 | lowering new and unlowering of existing pumping set. | 2 | Nos. | 3,500 ₹7,000 | 10,000 ₹20,000 | 5 ₹10 Lowest | 4,400 ₹8,800 | 2,000 ₹4,000 |
| 3.00 | P/F GI nut and bolt, washers for column pipes. | 10 | Nos. | 10 ₹100 | 50 ₹500 | 5 ₹50 Lowest | 80 ₹800 | 70 ₹700 |
| 4.00 | P/F Champion make Jain sheet for column pipe | 15 | Nos. | 80 ₹1,200 | 80 ₹1,200 | 2,000 ₹30,000 | 100 ₹1,500 | 70 ₹1,050 Lowest |
Tender Value
₹11.3 L
EMD Value
₹22,680
Closing Date
31 Jul 2026, 11:00 amClosed
Executive Engineer
Executive Engineer Jal Shakti Division Nalagarh District Solan HP
Repair and maintenance of Tubewell Kalibari in Tehsil Nalagarh, District Solan HP
2026_HPIPH_139929_1
6720-80 dated 24-07-2026
Open Tender
Civil Works
Item Rate
Nalagarh
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
₹22,680
1 Aug 2026
24 Jul 2026
31 Jul 2026
24 Jul 2026
31 Jul 2026
24 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, erection, testing & commissioning of submersible pumping of reputed make such as BS/ KSB/ Sabar,Johnston/Worthington conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having Charctorstics as mentioned in item No. 1 (a)greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:- | 1 | Set | - | - |
| 1.01 | Total Head in mtrs (i/c depth of Column Pipe in case of Bore Well) : 85 Mtrs. | - | - | - | - |
| 1.02 | Discharge:- (in LPS) of each pump : 40 Lps. | - | - | - | - |
| 1.03 | Dia of Rising main (in mm) : 250 mm | - | - | - | - |
| 1.04 | Dia of Column Pipe (in mm):- 200 mm | - | - | - | - |
| 2 | lowering new and unlowering of existing pumping set. | 2 | Nos. | - | - |
| 3 | P/F GI nut and bolt, washers for column pipes. | 10 | Nos. | - | - |
| 4 | P/F Champion make Jain sheet for column pipe | 15 | Nos. | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
Form6.pdf
Tender Documents • 0.33 MB
Form8.pdf
Tender Documents • 1.27 MB
TandC.pdf
Tender Documents • 0.44 MB
BOQ_207412.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .