| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.8 LAccepted-AOC C2 PAIXOMONTIRO APTS BEHIND NSD ALTO DABOLIM VASCO DA GAMA GOA 403 801 | SOUTH GOA | GOA | 403801 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹44.8 L+₹5.5 L (14.1%)Rejected-Finance FLAT NO 7 MHAMBRE BLDG DR FRANCISCO LUIS GOMES ROAD VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹45.3 L+₹6.1 L (15.6%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹46.8 L+₹7.5 L (19.2%)Rejected-Finance | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹65.0 L+₹25.7 L (65.6%)Rejected-Finance PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
Refer Docs
EMD Value
₹99,500
Closing Date
25 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
STRUCTURAL STRENGHTHING AND REPAIR TO CERTAIN BUILDING AT HANSA TECHNICAL AREA AND NAY GOA UNDER AGE BR I OF GE NW VASCO
2020_MES_406378_1
85343/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE NW VASCO
₹99,500
Yes
11 Mar 2021
23 Dec 2020
27 Jan 2021
23 Dec 2020
25 Jan 2021
11 Jan 2021
60 days
Amount
Chipping removing carefully concrete work by low impact hammer, breakar without damaging the structure & cleaning and disposal of debries outside the premises etc complete all as specified and as directed. Note: Hard concrete should not be removed by force.
Clean existing reinforcement with wire/ rotary wire brush making the surfaces free from loose material dirt etc complete, Applying two coats of alkaline rust converting primer confirming to ASTM-B-117 on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 6 hour between the coats and applying protective coating complete all as specified and as directed.
M&L for carry out application of 'Bi-polar migratory corrosion inhibitor of approved make on concrete surface. This inhibitor has migratory kind of property which permits the material to migrate to a vertual extent of 100mm, through pores of concrete, inhibiting the corrosion and de-passivating the Electro-chemical reaction. It has properly to attack anode as well as cathode, which is purely alkaline in nature (pH-9.5), so it has no carcinogen activity with concrete.
Providing and applying structural grade of approved make prior to application of any type of mortar plaster conforming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bond between old concrete and new concrete all as specified and as directed.
Building up the profile of structural members by using latex additives of approved make modified air cured mortar system (Polymer modified mortar) (1:5:15) in damaged areas in 30 mm thickness including leveling profiling etc complete all as specified and as directed.
M&L for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep hole in structural members at the interval of 500mm center to center in staggered manner or as directed by Engineer-in-Charge in RCC structural element. Work shall be carried out as under :- (i) Cleaning of holes - Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles - Insert 12mm dia Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun. Fix it inside the hole by applying thixotropic epoxy putty to ensure complete sealing . Cure the system for min 12 hrs. (iii) Cutting of nozzles - Cut the nozzles by chisel after completion of grouting without damaging structural elements.
M&L for Injecting of site mixed cement slurry grout, in the ratio 1:2 (1-cement, 2-water) including super plasticizer 250 ml/50 kgs. Mixing shall be done by mechanical mixture continuously stirring mechanically to keep cement particals in suspension. Injection of approved/specified grout by means of pump at a pressure of 0.5 Kg/sqcm etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled (for repair to slab) all as specified and as directed.
M&L for Injecting low viscosity high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, including mixing of material. Mixing of materials :- Mixing of material components (part a&b) in the required quantities as per manufacturer's instruction by weigh batching. Grouting maintain the pressure at exit (0.5 to 1.0 kg/sqcm) by monitoring pressure gauge at exit. Grout the material through prefixed nozzles in the structural element @ 100ml per nozzle. Repeat the process for all the nozzles. (Beam and columns)
Providing and applying jacketing around columns with Micro concrete M-40 including all lifts, shuttering, drilling holes and fixing shear Anchor as per specification complete all as specified and as directed. Notes:- 1.Reinforcement shall be measured and paid saperately. 2.Rates including jacketing, formwork and Micro concrete.
Replacement of steel reinforcement with TMT bars of appropriate size where 20% of cross section is reduced including dismantling of rusted steel including application of rust converter and applying protective coating complete all as specified and as directed.
M&L CRS TMT steel bars 10mm dia and over cut length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire all as specified and as directed.
All as per item No 11 here in before, but for 6 to 8 mm dia all as specified and as directed.
All as per item No 11 here in before, but for 5mm dia and over upto and including 10mm dia as in stirrups, binders etc all as specified and as directed.
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
S&F hard drawn steel wire fabric cut to length bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm dia not exc. 4 Kg/sqm all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) all as specified and as directed.
S&F PVC Rain Water Pipe 150 mm dia including all fittings, head , shoes, branches fixed in wall including joint with PVC adhesive all as specified and as directed.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls all as specified and as directed.
Dismantling mild steel work of any description not otherwise provided for all as specified and as directed.
S & F Mild steel roof trusses (framed), Trussesd, purlins, crane grantries, rails and framings and heavy bracket framing (Beam,tee, angle, channel or flat sections) conforming to Fe 410-W including cleats,distance pieces etc all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets all as specified and as directed.
Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with ANF (Board) edge tiles with Armstrong 24mm exposed grid. The tiles should have Humidity Resistance (RH) of 90%, NRC 0.5, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 34%.The tile shall be laid on Armstrong Prelude38 with 24 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15.34Kgs/M2 & pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make. The Tile & Grid system used together should carry a 10 year warranty all as specified and as directed.
Dismantling/Taking out existing hessain base felt of any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and levelled all as specified and as directed.
M&L for preparation of surface with wire brush and remove loose particle & laitance, wash with clean water, damaged or hollow portion, sharp edges etc. must be cut and removed till the morther slab. Fillig the cracks and damaged portion with polymer mortar and allow it to cure for 24 hrs. Brush apply the 1st Priming coat on prepared concrete/plastered surface by diluting 2 parts of Primeseal with 1 (one) part of water and allow to dry for 04 (four) hours. Apply the first coat of waterproofing coating without any dilution at the rate of 2 Sqm per liter over the primed surface. On the wet surface of 1st coat overlay a open-woven fibre glass mesh, min 40 GSM of size 2mm x 2mm and allow it to soak completely. Immediately apply the second coat with a roller, to ensure complete coverage of the fibre mesh. Apply the third coat after 6 to 8 hrs once the second coat is dry. Drying time between coats shall be 6 to 8 hours all as directed and as per manufacturers instructions.
M&L for 10mm thick plaster in cement mortar 1:4 mixed with 3% integral water proofing compound over roof top surface finished to even & smooth without using extra cement. Note :- Integral water proofing compound shall be measured and paid seperately
Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided for all as specified and as directed.
M&L for 75 mm thick Cement concrete type C2, 1:3:6 using 40 mm graded stone aggregate as in plinth protections, finished even and smooth without using extra cement all as specified and as directed.
Disconnecting existing tanks of capacity exc 500 and n exc 1000 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position all as specified and as directed. Note :Cleaning repairing, etc. shall be measured and paid separately
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. capacity exc 500 and n exc 1000 ltrs, complete all as specified and as directed.
S&F PVC ball valve 20mm dia high pressure of PTMT with aluminium rod & high density plastic ball screwed for iron pipe all as specified and as directed.
S&F 20 mm bore dia stop/Gate valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union, complete all as specified and as directed.
Dismantling water tanks exc 500 but n. exc 1000 ltrs all as specified and as directed.
Dismantling water tanks exc 250 and n.exc 500 ltrs all as specified and as directed.
Fixing only rotational moulded polyethylene water storage tanks (Cylinderical, vertical with closed top) of 500 Ltrs capacity hoisted and fixed in position all as specified and directed in SSR Pt I. Note - Rotational moulded polyethylene water storage tanks shall be issued under Schedule B stores free for fixing only.
Fixing only rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position all as specified and directed in SSR Pt I. Note - Rotational moulded polyethylene water storage tanks shall be issued under Schedule B stores free for fixing only.
S&F 15mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 15mm-142gms) all as specified and as directed.
S&F 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm-210gms) all as specified and as directed.
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 15 mm dia all as specified and as directed.
All as per item No. 40 here in before, but for 20 mm dia all as specified and as directed.
Supplying and laying of 25 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
All as per item No. 42 here in before, but for 20 mm dia all as specified and as directed.
S&F in repairs Stop Valve 20 mm bore of standard PTMT any colour high pressure screwed for iron pipe and fixed all as specified and as directed.
S&F in repairs Stop Valve 15mm bore of standard PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm-90gms) all as specified and as directed.
S&F in repairs fancy type chromium plated 15 mm bore stop valve/angle cock cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S & F in repair 50 mm bore Low density polyethylene pipes (LDPE) of pressure rating 6 Kgf/ Sq. Cm., fixed complete to walls, ceilings or in floors etc. all as specified and as directed.
Demolition of stone /boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed.
M&L for Pre - cast cement concrete masonry with Grade C-5.0, using 20mm graded stone aggregate with solid blocks wall built in cement mortar 1:6 all as specified and as directed.
Taking down cement plastering at any description on brick or stone wall etc including raking out joints hacking for key scrubbing down with water etc and removal of debries and depositing where directed all as specified and as directed.
M & L for complete removal of existing treatment on ceilings all as specified and as directed.
M&L for rendering 5 mm thick in cement mortar 1:3 in ceiling finished even and smooth without using extra cement all as specified and as directed.
M&L for preparation of new plastered ceiling surface for painting all as specified and as directed.
M&L for preparation of plastered surfaces of ceiling and applying 3 mm thick wall care putty on ceiling and two coat of oil bound distemper over chalk whiting all as specified and as directed.
M&L for rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in cement mortar 1:4 & 2nd coat of 5mm in cement mortar 1:4 mixed with integral water proofing compound finished to even & smooth without using extra cement. Note :- Integral water proofing liquid shall be measured and paid seperately.
Supply only water proofing compound all as specified and as directed.
M & L for preparation of old surfaces by complete removal of existing treatment of painted walls and applying two coat of acrylic anti-fugal weather proof exterior grade paint of first quality over a coat of primer including sealing the cracks all as specified in manufacturers instruction all as specified and as directed.
M & L for preparation of new surfaces by complete removal of existing treatment of painted walls and applying two coat of acrylic anti-fugal weather proof exterior grade paint of first quality over a coat of primer including sealing the cracks all as specified in manufacturers instruction all as specified and as directed.
M&L for applying two coats of water proofing treatment @ 5 Sqm per Ltr for first coat and 6 Sqm per Ltr for second coat alongwith suitable pigments for colour all as specified in manufacturer's instructions and to be applied through applicator of authorised manufaturer with 5 Years guarantee all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on concrete solid block wall internal surface finished even and smooth without using extra cement all as specified and as directed.
M & L for complete removal of existing treatment on walls all as specified and as directed.
M&L for preparation on newly plastered surface of wall for painting all as specified and as directed.
M&L for applying 3 mm thick wall care putty on plastered wall surfaces and applying two coats of oil bound distemper over suitable primer all as specified and as directed.
M & L for complete removal of existing treatment and preparation of old surfaces of walls and applying two coat of distemper oil emulsion over a coat of primer complete all as specified and as directed.
M&L for preparation of old painted surface of wall and applying one coat of oil bound distemper all as specified and as directed.
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for all as specified and as directed.
M&L for mild steel deformed bars or TMT bars 6mm to 8mm dia, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L for reinforced Cement Concrete Type A1 1:1.5:3 using 20 mm graded stone aggregate for slabs suspended on walls, beams and columns, in floors, roofs, landings and in shelves and the like similar works or beam, column, wall etc including necessary form work all as specified and as directed.
M&L for preparation of steel surface and applying one coat of red oxide zinc chrome primer and two coats of Epoxy anticorrosive paint over 10 cm width or girth all as specified and as directed.
S& F in repair Ball brass valve, high pressure, with polythene float horizontal plunger type, IS-1703-2000 marked screwed to iron pipe or brass ferrule of size 20 mm bore complete all as specified and as directed.
S& F in repair Ball brass valve, high pressure, with polythene float horizontal plunger type, IS-1703-2000 marked screwed to iron pipe or brass ferrule of size 25 mm bore complete all as specified and as directed.
M&L for precast cement concrete 1:2:4, type B1 using 20 mm graded stone aggregate in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4 all as specified and as directed.
M&L for providing Plain Cement Concrete 1:3:6 type C1 using 20mm graded stone aggregate as in surface channel and drain or wherever required all as specified and as directed.
M/s J.D. DESAI
M/S Kartik Enterprises
K M SUBHANAIAH
pk janardhanan
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .