| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 CrAccepted-AOC | ₹5.9 Cr | L1 | Accepted-AOC being lowest and reasonable bid |
| 2 | L2₹6.1 Cr+₹19.1 L (3.22%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹6.1 Cr+₹19.1 L (3.22%) | L2 | Rejected-Finance being not lowest bid |
| 3 | L3₹6.2 Cr+₹23.5 L (3.96%)Rejected-Finance | ₹6.2 Cr+₹23.5 L (3.96%) | L3 | Rejected-Finance being not lowest bid |
| 4 | L4₹6.4 Cr+₹50.6 L (8.53%)Rejected-Finance | ₹6.4 Cr+₹50.6 L (8.53%) | L4 | Rejected-Finance being not lowest bid |
| 5 | L5₹6.5 Cr+₹60.4 L (10.2%)Rejected-Finance | ₹6.5 Cr+₹60.4 L (10.2%) | L5 | Rejected-Finance being not lowest bid |
Tender Value
₹3.7 Cr
EMD Value
₹4.5 L
Closing Date
22 Oct 2024, 6:00 pmClosed
CHIEF ENGINEER AIR FORCE JAMMU
CHIEF ENGINEER AIR FORCE OFFICE JAMMU
WORK SERVICES FOR INDUCTION OF G-PROJECT AT AF STN JAMMU
2024_MES_641091_3
CEAFU-19-2023-24
Open Tender
Civil Works
Lump-sum
456 days
JAMMU
AS PER TENDER DOCUMENTS AND NIT
9 documents required · 9 mandatory
₹2,000
GE AF JAMMU
₹4.5 L
CHIEF ENGINEER AIR FORCE OFFICE JAMMU
5 Feb 2025
1 Oct 2024
30 Oct 2024
1 Oct 2024
22 Oct 2024
15 Oct 2024
4 Oct 2024 - 8 Oct 2024
10 Oct 2024
Amount
Schedule A Part-I (BUILDING WORK )Note: this Schedule is not pre priced by MES and the pre priced rate indicated as Rs 0.00 under Col 5 signifies this fact only.
Construction of building for workshop, Lab 1,Lab 2 ,Lab 3,Office,Toilets and inspection pits etc with permanent specification complete all as specified and shown in drg.
Construction of parking shed for 17 number of motorcycles etc with permanent specification complete all as specified and shown in drg.
Construction of parking shed for parking shed for 03 number of cars etc with permanent specification complete all as specified and shown in drg.
Construction of parking shed for platform with ramp (02 Nos) for special vehicle etc with permanent specification complete all as specified and shown in drg.
Total amount of Schedule 'A' PART-I (BUILDING WORK)
Total amount of Sch 'A' PART-II ( SITE CLEARANCE AND DEVELOPMENT)
Total amount of Sch 'A' PART-III (SECTION-I) ( INTERNAL ELECTRIC SUPPLY WORKS)
Sch 'A' PART-III ( Section-II) ( INTERNAL ELECTRIC SUPPLY WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
M & L for 8 module Modular metal Flush box as per site requirement.
S&F Telephone Jack RJ-11 complete with all accessories all as directed and specified.
M&L Telephone Cable RJ-11 complete all as directed and specified.
S & F LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption <20W, luminaire lumen >2000 lm, system efficiency of > 120 lumens/W, LED Make : Nichia/ Cree/ Everlite / Eclison/ Osram/ Lumiled, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class 1, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficiency>85%, power factor > 0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min) as per L7O criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level < 60 V DC as per IEC standard with LM70 & LM 80certification.
S & F 2ft x 2ft recess mounted full panel LED luminaire with white powder coated housing acting as heat sink and frame in CRCA sheet, high efficiency LED grade diffuser , in built electronic driver duly wired up to terminal block, power consumption< 36W, luminaire lumen > 3500lm and system efficiency >120lm/W, CRI>80, LED Make:- Nichia/ Cree/ Everlite / Eclison/ Osram/ Lumiled with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class 1, colour temp -5700K, Ingress protection IP 20, , driver efficiency >85%, 50,000 burning hours (min) as per L70 criteria, ambient temp 0 to 500C, power factor >0.95, THD < 10% , surge protection in CM -3 KV, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard, with LM79 & LM80 certification.
S & F LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption <10W, luminaire lumen >1000 lm, system efficiency of > 100 lumens/W, LED Make : Nichia/ Cree/ Everlite / Eclison/ Osram/ Lumiled, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class 1, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficiency>85%, power factor > 0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min) as per L7O criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level < 60 V DC as per IEC standard with LM70 & LM 80certification.
S & F rugged LED midbay / highbay LED light fittings of capacity 300 Watts,41000lm with black colour, powder coated al;uminium heat sink for efficient heat dissipation and high purity anodized refelector with electro-chemcially anodised matt finish inside, the effective glass optics for maximum illumination radius of aluminium reflector not less than 240mm dia of outer peripherials. Driver and accessories prewired power consumption less than 300W, with luminaire lumen 41000lm,colour temperature not less than 6600k, Ingress protection IP-65 with high lumen output minimum 137lm/Watts with insulation class 1 overall current protection ( IEC61000,61547 and 61347) and SC protection ( IEC 61000,61547and 61347) with automatic inbuilt high voltage protection and surge protection of 14 KV (04 inbuilt and 10 KV out),50 HZ 110 VAC to 440 VAC with all certifications of ISI,CE and ROSH having working tempertaure range of -10 degree celius to +70 degree celisus ,antiglare properties dimmable waterproof with 120 degree light beam spread downward direction complete in all respect and as specified .
S&F of wall mounted Air circulator 750 mm sweep, heavy duty motor ( 3 Nos Motor speed) with double ball bearings ZZ (permanent Lubricated) for longer life made of metallic , With sturdy close mesh guards (112 Spikes) with powder coating to ensure corrosion resistance as per standards with aerodynmically designed blades ( 03 to 04 Nos) for higher air delivery and minimum noise level (60 db to 65 db ), AC, single phase, 230 Volts, 1400 revolutions per minute with thermal overload protection including connection with 1.5 sqmm mutistrand copper conductor flexible wire from ceiling rose, including wall bracket and mounting accessories etc proper hole, with adjustable upward and downward tilt mechanism and necessary fixing arrangement and making good to disturbed surface complete all as specified and directed.
S&F of wall mounted Air circulator 450 mm sweep, heavy duty motor ( 3 Nos Motor speed) with double ball bearings ZZ (permanent Lubricated) for longer life made of metallic , With sturdy close mesh guards (112 Spikes) with powder coating to ensure corrosion resistance as per standards with aerodynmically designed blades ( 03 to 04 Nos) for higher air delivery and minimum noise level (60 db to 65 db ), AC, single phase, 230 Volts, 1400 revolutions per minute with thermal overload protection including connection with 1.5 sqmm mutistrand copper conductor flexible wire from ceiling rose, including wall bracket and mounting accessories etc proper hole, with adjustable upward and downward tilt mechanism and necessary fixing arrangement and making good to disturbed surface complete all as specified and directed.
S&F of Exhaust fan 200mm sweep, heavy duty motor with double ball bearing, made of sturdy engineering plastic/PVC body , With bird guard / louver shutter to protect the fan in running condition, AC, single phase, 230 Volts, including connection with 1.5 sqmm mutistrand copper conductor flexible wire from ceiling rose, including outside louvers with proper hole, and necessary fixing arrangement and making good to disturbed surface complete all as specified and directed.
S&F LED Street Light fitting 45 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K), CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012, for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, complete all as specified and as directed by Engr-in-charge.
Supply and fixing MCB Single Pole 2 Amps rating 240V, 10KA 'C' curve miniature circuit breaker complete with connection testing and commissioning complete all as specified.
Supply and fixing MCB Single Pole 6 Amps rating 240V, 10KA 'C' curve miniature circuit breaker complete with connection testing and commissioning complete all as specified.
Supply and fixing MCB Single Pole 16 Amps rating 240V, 10KA 'C' curve miniature circuit breaker complete with connection testing and commissioning complete all as specified.
S and F MCCB 4P 63 Amps Icu =16 KA at 415 volts with fixed type thermal magnetic release and adjustable over load setting Ir = (0.8 to 1.0) x In,Ics = 100 % Icu and adjustable short ckt 5 to 10 ln setting complete with phase seperator, Spreaders, Phase barrier etc
Supply, installation,testing and commissioning of turbo roof ventilators of size 600x600mm made of aluminium with integrated and reinforced main bearing housing, twin ZZ ball bearings encased in single integrated bearing housing assembly (AERODYNAMICAL) top disc should be aluminium material and bearing will be ZZ double 6002 bottom ring will be Stainless steel , suitable to withstand high wind speed of 125kmph, heavy air charge per hour (10-30) capable to provide free inword airflow without restriction , FRP dome thickness min 2.00 MM FRP dome assembly virotex type equivalent to UV resin type.Fan weight should be min 6 kg with 42 Nos of blades and blade thickness should be min 0.5 mm and should be of stainless steel SS-304 all as specified and directed by engr in charge.
M and L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm GI earth lead wire by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following: (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Notes: (i) On testing after completion of earthing, if the desired earth resistance is not less than 5 ohm obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.The unit rate includes GI pipe up to 7.5m for protection of earth lead.
(ii) The unit rate includes main earthing lead/strip from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance is recorded more than 5.0 ohms then the Earthing shall be re- done by the contractor without any extra cost to the department (iv) If there is a requirement of grid Earthings to achieve the desired earth resistance, as directed by Eng-in-charge, then inter connecting of different earthings shall be done at no Extra cost
Total amount of Sch 'A' PART-III (Section-II) (INTERNAL ELECTRIC SUPPLY WORK)
Total amount of Sch 'A' PART-IV (INTERNAL WATER SUPPLY WORKS)
Total amount of Sch 'A' PART-V (PLUMBING WORKS)
Total amount of Sch 'A' PART-VI (SEC-I) (AIR CONDITIONING AND REFRIGERATION WORKS)
SCHEDULE `A' PART-VI(SEC-II (AIR CONDITIONING AND REFRIGERATION WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply and fix wall mounted Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA with Digital display for showing input/output voltage, Low & High voltage cut off protection, Built in thermal overload protection and copper winding all as specified and as directed by Engineer In Charge
Supply and fix wall mounted Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA with Digital display for showing input/output voltage, Low & High voltage cut off protection, Built in thermal overload protection and copper winding all as specified and as directed by Engineer In Charge
Rapid 4 Modular 1 Plug in socket switch for AC with shutter in three mode ON-OFF-ON including 5 Pin Multi socket 240 volts single phase 50 HZ .of 25 amps current cap.
Rapid 4 Modular 1 Plug in socket switch for AC with shutter in three mode ON-OFF-ON including 5 Pin Multi socket 240 volts single phase 50 HZ .of 16 amps current cap.
S&F for outdoor unit mounting brackets Factory made heavy duty floor anchored made out of 2mm MS sheet bent to shape duly slotted for adjustment, powder coated GI/ aluminium stand for fixing Outdoor Condensing Units on the roof (or on the wall as required) of the room with serrated complete with s/sdash/hole fastener's of adequate length for fixing the bracket to wall or on roof for mounting of Out Door unit complete all as specified and directed (Set of Two)
Total amount of Sch 'A' PART-VI(SEC-II) (AIR CONDITIONING AND REFRIGERATION WORKS
Total amount of Sch 'A' PART-VII (Section-I) (LIGHTENING PROTECTION WORKS)
SCHEDULE `A' PART-VII (SEC-II) (LIGHTENING PROTECTION WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
S and F Epoxy insulator duly coloured with necessary fixing arrangement on wall and roof for fixing of down conductor complete all as specified and directed.
Earthing complete with copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 20 x 3 mm copper earth strip by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following: (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 40 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing Notes: (i) On testing after completion of earthing, if the desired earth resistance is not less than 5 ohm obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.The unit rate includes GI pipe up to 7.5m for protection of earth lead.
(ii) The unit rate includes main earthing lead/strip from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance is recorded more than 1.0 ohms then the Earthing shall be re- done by the contractor without any extra cost to the department (iv) If there is a requirement of grid Earthings to achieve the desired earth resistance, as directed by Eng-in-charge, then inter connecting of different earthings shall be done at no Extra cost
Total amount of SCHEDULE `A' PART-VII (SEC-II) (LIGHTENING PROTECTION WORK)
Total amount of Sch 'A' PART-VIII (Section-I) (FIRE ALARM AND EXTINGUSHER SYSTEM WORKS)
SCHEDULE `A' PART-VIII (SEC-II) (FIRE ALARM AND EXTINGUSHER SYSTEM WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply installation testing and commissioning of repeater panel complying with BS EN 54 suitable for wall mounting confirming to IS-2189 fabricated out of 16 guage CRCA sheet incorporating audio visual indication including dry type maintenance free battery of suitable capicity and battery charger complete all as specified and directed by Engr-In-Charge.
Total amount of Sch 'A' PART-VIII(SEC-II) (FIRE ALARM AND EXTINGUSHER SYSTEM WORKS
Total amount of Sch 'A' PART-IX (Section-I) (EOT CRANE WORKS)
SCHEDULE `A' PART-IX(SEC-II) (EOT CRANE WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Design,Supply, installation, testing and commissioning of electrically operated, overhead traveling (EOT) cranes of capacity 05 Ton, conforming to IS : 3177 (latest revision), with span of 25 mtrs (approx), height of lift 6.5 mtrs (approx), travel length 25 mtrs (approx), suitable for operation on 415 Volts, 3 Phase, 4 wires, 50 HZ supply, double girder box type, with necessary steel supporting structures with Hoist speed 3mtrs / min and creep/micro speed 0.3mtr/min, cross travel speed 10 mtrs / min, long travel speed 10 mtrs / min with micro drive through clutch and geared motor of suitable capacities with control panel, power and controlling cables, confirming to relevant IS, controlled by pendent push button station and radio remote control switch of operation, with and including dia of steel rope of suitable size dia , operation system hoist / cross travel/ long tarvel / electrically operated with pendent DSL system of shrowded busbar type .
2. The crane will be put to use for 365 Days’ continuous duty with CT, LT and Hoist movements. 3. The department shall be responsible for providing suitably rated electrical outlet in the Main Electrical Control Panel/Main Distribution Board of the buildings (Refer Drawings). All other works, electrical earthings and associated incidental and minor works shall be the responsibility of the contractor. 4. The details of RCC brackets, End plates etc are shown in relevant drawings. The contractor shall certify that these are sufficient and meets the requirements of his design. 5. The shop floor environment will be dust prone, humid, welding fume filled and ambient temperature going up to 50ºC. Weather conditions are tropical. Crane shall be kept in the normal shop floor condition without any temperature controlled enclosure / shop. Max. temperature variation is 25 deg Celsius in 24 hours. Sound level should be minimum and the crane should have decent aesthetic look. Ambient Temperature: 4º C - 50º C & relative Humidity: 55%. 6. Major Technical specifications of the crane are given below. These are to be complied with by the contractor/manufacturer. The parameters which are not specified are to be as per Contractors'/OEM's own design. The contractor shall submit following drawings alongwith the design calculation folder ( for mechnical and civil design) , and get the drawings approved from the Accepting Officer . The drawings shall be complete in all respect.
Hoist: Hoist should be as per IS: 3938 (latest version) of STAHL, DEMAG, INDEF make. Only Low Head Room Hoist shall be acceptable. STRUCTURAL FABRICATION (Constructional Details): Bridge Girder: Shall be of Double Girder Box Type construction having Minimum vibrations. End Carriage: Fabricated from rolled steel sections / plates as per IS:2062 Raw Material: Only tested quality steel Fe 410 WB as per IS-2062, IS:1964 & IS:808 and certified for quality by reputed inspection authorities, shall be used. Number of Joints allowed: Single Joint Welding Electrodes for all Horizontal Welding: E 7018 Electrode only should be used. Welded Joint Testing: All Butt Welded Joints (both compression/ tension and flanges / web joints)shall be subjected to 100% X-Ray Testing and X-Ray Films to be produced for evaluation and form part of the completion documentation). Mechanical Joints: Fit Bolts (as per IS 3640 –1982) for all joints coming in main members. Heat Treatment & NDT Examination: The Trolleys shall be stress relieved, if necessary, by thermal heat-treatment process after welding & NDT. All welding shall be tested by NDT means [MPI, LPI & RT] after stress relieving operation (Govt. approved Test House & certificate). Manufacturer to furnish the details of facilities for Heat Treatment furnace & NDT Lab at their works. All the welded joints should be NDT tested by Govt. approved Test House & certificate / X-Ray films to be submitted at time of inspection.
Gear & Gear Boxes Details: Gear Box should be of fabricated type duly stress relieved. Pinions made of En 24 and gears of En 18. Gears in all the Stages shall be helical in design and to be of machined, lapped and hardened Straight and helical spur gearing shall normally be used for all motions. Worm and bevel gears shall not be used. First and high speed reductions shall be through helical gears. All first reduction pinions and also the other pinions if feasible shall be integral with the shafts. All gears shall be of hardened and tempered alloy or carbon steel with machine cut teeth. Gear tooth shall be cut in metric module system. Surface hardening of teeth is not allowed. The Gears / pinions should be hardened to HRC 50-55 and ground. Please note that gears and pinions must have pressure angle of 20° only. Lubrication: Suitable lubrication system shall be provided for gear box, all rotating parts wherever applicable. Details of the same to be furnished. Please indicate the type of Lub. Oil & grease, quantity also. Rope Drum: Shall be of fabricated type stress relieved or seamless pipe. The circumferential weld joints shall be tested by 100% X-Ray quality (Please mention the size). The size of drum shall be 265mm length 1050mm no. of groves each side 29nos . Wheel : Trade mean dia of wheel for cross and long travel shall be made of forged steel of suitable dia. Type of Coupling: Couplings should be flexible geared Barrel type. No pin / bush / rubber type coupling to be used. Machining Operation: All mechanical mating surfaces and wheel seating areas are to be machined to the required finish and protected. Hoist Wire Rope Details: Fiber core confirming to IS: 2266. With adequate Wire rope, No. of fall -08 6x36 constructions with adequate minimum breaking load. Input Power Supply: Shall be 415 ± 10% Volts, 50 ± 3% Hz, 3 Phase, AC.
Control Voltage: Shall be 110V AC. Protection: All Panels, Limit-Switches and Motors shall have IP 54 protection. Motor Details: Squirrel Cage Induction Crane duty motors having 960 RPM, Totally enclosed, fan cooled, ( TEFC) Insulation Class-F & confirming to relevant latest IS:325, and IS-123, S4 duty, 150 starts per hour and 40% CDF and contractor to provide other details like No. of motors, capacity of motor, Frame size, make, type and No. of poles etc.Hoisting motor with design calculation. Type & details of Brakes for all motions: Conical rotor type or "Fail to safe" action type Electromagnetic shoe / disc brakes type to be provided to hold the mechanism in position instantaneously as soon as the power supply is 'OFF' either accidentally or intentionally for all motions. Brake wheel dia for hoisting shall be 150mm having breaking forged 9Kg/m Model MDT-150 . Brake wheel dia cross travel shall be 100mm breaking forged 6kg/m Model MDT-100 Electric Contactors: shall have SIEMENS / L&T / GE / BCH/Schenider contactors suitable for Crane operations. Crane duty AC-4 ratings. Contactors Rating: The rating of all Contactors shall be at least 50% higher than the respective electric motor full load current, at the specified duty cycle. Wiring: All the panel wiring should be done by using standard multi core Copper highly flexible, double insulated cables and of Butyl Rubber. Earthing for Electrical items in Crane: Shall be carried out as per IS. Trailing Cables: Trailing cables (Extra flexible having copper conductors only) should be traveling on rollers moving on separate I- Beam parallel to Bridge Girder and both for LT & CT shall be supplied and Erected by supplier. Illumination: 2 Nos. of 60 Watts LED Lamps & fittings shall be provided under the Bridge and 1 No. shall be provided under CT Trolley. (Total lights 3 Nos.).
Total amount of Sch 'A' PART-IX(SEC-II) (EOT CRANE WORKS
Total amount of Sch 'A' PART-X (BRICK WORK AND GRANITE SIGNAGE WORKS)
Total amount of Sch 'A' PART-XI ( (Section-I) (ROAD/PATH/CULVERT/HARD STANDING WORKS)
Sch 'A' PART-XI ( (Section-II) (ROAD/PATH/CULVERT/HARD STANDING WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
S&F glow sign board of size 1200mmX900mm including all necessary elelctrification and fixing arrangement complete all as specified and directed.
Total amount of Sch 'A' PART-XI (SEC-II) (ROAD/PATH/CULVERT/HARD STANDING WORKS
Total amount of Sch 'A' PART-XII (EXTERNAL WATER SUPPLY WORKS)
Total amount of Sch 'A' PART-XIII (Sec I) (EXTERNAL ELECTRIC SUPPLY WORKS)
Sch 'A' PART-XIII (SEC-II) (EXTERNAL ELECTRIC SUPPLY WORKS) Note: This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply, installation, testing and commissioning of indoor automatic/servo voltage controller three phase, 50Hz (confirming as per BIS 9815 : Part 1: 1994 reaffirmed 2009) Naturally oil cooled of 160 KVA, unbalanced type, copper wound, digital display type, Relay free smooth and silent operation with first Filling ofTransformerOil having the following specification :- (i) Input voltage 340-480V as per ground requirement. (ii) Output voltage stabilized at any designed/desired voltage 415 +/- 1% adjustable. (iii) No distortion in wave form. (iv) Response time not to exceed 10mille seconds (v) Sensitivity (+_ 1%) (vi) Rate of correction 8 volt/second for single phase and 20 volt/second for phase to phase (vii) No load losses less than 0.5% (viii) Full load losses less than 2.0% (ix) Duty cycle continuous 24 x 7, Efficiency more than 95% (x) Type of load 3 Phase, unbalanced type (xi) Digital display voltmeter and amp meter of suitable rating Protections (xii) Over load/short circuit protection (xiii) High/low voltage cut off (ix) By pass arrangement in case of emergency (xv) Single phase sequence change protection
Supply, installation, testing and commissioning of diesel engine driven silent generating set, 415 volts, 160 KVA 3 phase, 0.8 power factor, 50 Hz, brushless, 1500 rpm, self excited, self regulated, AC, and engine as per IS: 10001/ 10002 and alternator as per IS: 13364 complete with foundation, control panel with necessary meters, AMF Panel with relay and switch gear for automatic starting on mains failure and sound proof canopy all as specified and as directed with and including following:- (A) ALTERNATOR: Standard design alternator rated at 160 KVA net output at site after considering all derating factors, site conditions and at power factor 0.8, AC 3 phase, 4 wire 415 volts, 50 cycles, 1500 rpm, self excited, self regulated, screen protected, drip proof IP-23 enclosure, brushless design with hub and sealed ball/roller bearing, with winding on each pole faces, insulating class H, band of voltage regulation +/- 1% operated voltage from no load to full load and shell conforming to BS-2613/BS-5000 and shell B in position to ganarate supply with frequency regulation within +/- 3% tolerance, revolving field type. (B) DIESEL ENGINE: Adequate capacity diesel engine suitable to above alternator, water cooled, to drive independently above above alternator and after considering derating as applicable for tropical conditions existing at jammu ( J and K) site directly coupled to alternator through flexible coupling or multicylinder, multistroke, direct injection, cold starting, 1500 rpm, as per relevant ISI/BS-5514 with an overload cap of 10% for 1 hour in any 12 hours continuous running complete with standard accessories all as specified and required for safe running and operation. salient features of accessories shall be as under:-
(i) Flywheel housing (ii)Air cleaner wet/dry type (iii) fuel Filter (iv) Fuel Injection system incl.injection pump, solenoid switch, nozzle as per manufacturer's specifications. (v) Lubricating oil filter, bypass filter, oil cooler (vi) Lubricating oil pump (vii) Turbocharger (viii) Radiator for water cooling (ix) 12 volts starting system consisting of batteries of capacity as recommended by manufacturer, battery connections with copper leads and with lugs of adequate size, initial charging of batteries, battery charger/ generator with regulator, starter motor, starter gear, start and stop push buttons, ignition key and switch. (x) Residential type exhaust silencer complete with exhaust pipe of 150 mm dia upto outside the accoustic enclosure, all covered with glass wool wrapped with aluminium foil of 28 swg adequate to create draft for safe exhaust without transferring vibrations to buildings/walls, flexible exhaust pipe complete. (xi) Microprocessor control electronic metering and module (ECPG) for indication of battery voltage, oil pressure, water pump, engine rpm, hour meter and protection against low oil pressure, high water temperature and over speed of engine incl. electronic governing. (xii) Battery charging indicator (xiii) Radiator cooling system comprising of radiator, radiator fan belt, water pump with belts, thermostat. (xiv) Fuel hoses. (xv) Air intake system
(xvi) Common base frame of sturdy design suitable for antivibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions ( C) CONTROL PANEL/AMF Panel: Control panel & AMF Panel shall be indoor cubical type made out of suitable thick CRCA sheet complete factory made dust and vermin proof, totally enclosed with front opening of 415V 3 phase, 4 wire system AC 50 Hz, having Aluminium busbar of capacity suitable for 110% full load of 128 KW generating set with relays, contactors, timers, switchgears, indicators, switches and standard accessories as per manufacturers instructions (D) Accoustic insulated enclosure/canopy for Generating set:- Accoustic enclosure shall be factory built suitable and conforming to the provisions of environment (protection) second amendment rules 2002 issued vide notification no. GSR371(E) dated 17 May 2002 at Sl No 94 (Para 1&3) (noise limit for warded DG Set upto 1000KVA type) and tested complete. NOTE:- The capacity of generator set shall be net after all de-rating factors as per relevant design.
Construction of Platform with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 mm thick in foundation, brick work in CM 1:6 with sub class "B" old size brick, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc of size 3000mm x 2500mm x 1200mm with fencing foldable upto 1.5m height, gate with locking arrangements using GI wire mesh, GI wire 4mm dia, angle iron, MS plate etc, complete all as specified and shown in drawing No. CEPZ/ TD-504
(b) OUTGOING (i) MCCB Four pole 160 Amps Icu =36 KA at 415 volts with micrprocessor release - 02 No (O/G) ( 1 W + 1S) It should be with adjustable over load setting Ir = (0.8 to 1.0) x In,Ics = 100 % Icu and with adjustable thermal setting.Class II front face with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc. (ii) MCCB Four pole 125 Amps Icu =16 KA at 415 volts fixed type with thermal magnetic release - 01 No (O/G) .It should be with adjustable over load setting Ir = (0.8 to 1.0) x In,Ics = 100 % Icu and with adjustable thermal setting.Outgoing MCCB 160 Amp, Four pole , should be thermal based release with adjustable O/L, Adjustable S/C setting Class II front face with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc iii) MCCB Four pole 40 Amps Icu =16 KA at 415 volts with thermal magnetic release - 01 No (O/G) .It should be with adjustable over load setting Ir = (0.8 to 1.0) x In,Ics = 100 % Icu and Class II front face with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc (iv) MCB SPN 32 Amps 10 KA - 02 No All accessories prewired with suitable size copper wire with stand high temperature, housed in cubical panel made out of standard MS sheet factory made duly powder coated front and rar door open able with locking arrangement complete with foundation as required or recommended by manufacturer.
M and L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 25 x 4 mm GI earth strip by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following: (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 40 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Notes: (i) On testing after completion of earthing, if the desired earth resistance is not less than 5 ohm obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.The unit rate includes GI pipe up to 7.5m for protection of earth lead.
(ii) The unit rate includes main earthing lead/strip from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance is recorded more than 5.0 ohms then the Earthing shall be re- done by the contractor without any extra cost to the department (iv) If there is a requirement of grid Earthings to achieve the desired earth resistance, as directed by Eng-in-charge, then inter connecting of different earthings shall be done at no Extra cost
Total amount of Sch 'A' PART-XIII (SEC-II) (EXTERNAL ELECTRIC SUPPLY
Total amount of Sch 'A' PART-XIV (Section-I) (CHEMICAL EARTHING WORKS)
Total amount of Sch 'A' PART-XIV (Section-II) (CHEMICAL EARTHING WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply & fix Copper strip 50 x 6 mm with saddles and fixing screws etc. for roof conductors and down conductors above groundcomplete all as specified and directed
M and L for Advance chemical Maintenance free earthing system based on ground soil resistivity condition including surveying and testing of soil strata and providing the solution to achieve Earthing resistance less than one ohm. with and including necessary earthwork & excavation or boring the required nos of holes in any type of soil, refilling with good earth and backfill compound, removing excavated soil, levelling and making good the surrounding of earth pit all as specified and directed by Engineer in charge. Chemical earthing complete with copper earthing plate electrode of size 900x600x5mm thick buried directly into ground vertically to the depth not less than 5.0 metre below normal ground level with top edge of earth plate not less than 4.0 metre below normal ground level,surrounding on the all size by charcoal, common salt and magnisium sulphate(or any chemical recommended by manufacturer for increasing earth conductivity) starting from the ground below earth plate in alternate layers including replacement of excavated soil with artificially treated soil (soil having low resistivity) connected to copper strip of size 50 x 6 mm earth lead by means of copper lugs, nut, bolts and washers, earthing strip protected by 50mm bore light grade GI pipe in floor and fixed with wall with proper size of Fe clamps and watering pipe 20 mm bore GI light grade including wire mess , funnel PCC earth chamber pit with 1:2:4 type b-1 (using 20 mm graded crushed stone aggregate) including form work cement mortar with height 300mm above normal pit, excavation and earth work in any type of soil including testing on completion for desired result of 1 Ω all as shown and specified in plate No 3 of SSR part-I 2009 complete all as specified and directed.
(a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 80 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. (g) Earth enhancing compound for Earthing pit as required to have a desired result of less than 1 ohm. (h) No of electrodes can be increaed wherever required as recommened by original manufacturer to achive desired result (i.e. below 1 Ohm) without any extra cost. (i) The earth enhancing compound shall be highly conductive and anti-corrosive having chemical composition of required quantity Bentonite 40%. Copper Sulphate 10%, gypsum 5%, Graphite 10%, Alum 5%, Zinc Sulphate 10%, Aluminium Sulphate 10% surrounded by soil friendly backfill compound 10% non-soluble in water with recommended quantity 25 kg/bag x 9 Bag/Earth Pit all as specified and directed. (j) In case of requirement of replacing the earth around the electrode with high conducting earth, the same shall be done without any extra cost and quoted rate is inclusive for the complete job.
(k) The complete job is inclusive of Forming of grid Earthing system to achieve desired result as directed and specified by engr in charge with interconnecting all the earthing electrode seperated by appropriate distance with and including provn of copper earth strips of require size to make ring earth and connected upto test point terminal with brazing and to be burried in appropriate depth not less than 40cm below normal ground level all as specified and as directed.
Total amount of Sch 'A' PART-XIV (SEC-II) (CHEMICAL EARTHING WORK)
Total amount of Sch 'A' -XV (Section-I) (SEWAGE DISPOSAL WORK)
Total amount of Sch 'A' PART-XV (Section-II) SEWAGE DISPOSAL WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 M dia X 3.0 M effective depth with over flow fillter complete all as specified shown on drg no CEAF/TD-15/2020 sheet 1/1 to 1/2.
On site LLDPE septic tank conventional type, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 20 users.
Total amount of Sch 'A' PART-XV (SEC-II) (SEWAGE DISPOSAL WORK)
Total amount of Sch 'A' Part-XVI (AREA DRAINAGE WORK)
NOTE: Amount against schedule of credit for retrieved materials mentioned under relevant part of Sch of Credit of tender document in PDF form will be deducted offline/manually from overall amount quoted by the lowest bonafide bidder during award of contract.
MAMTA ENTERPRISES (BID ID -3147229)
bamral builder (BID ID -3144852)
M/s V6 Infrastructures Pvt. Ltd. (BID ID -3145535)
R R CONSTRUCTION (BID ID -3146715)
SURAT SINGH AND SONS (BID ID -3147104)
Chandra Construction (BID ID -3147187)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .