| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 LAccepted-AOC 00 ITBAHRA GAUR KANIKAPUR ROAD KANIKAPUR BASTI UTTAR PRADESH 272163 | BASTI | UTTAR PRADESH | 272163 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹40 L+₹1.5 L (3.91%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹44.3 L+₹5.8 L (15.1%)Rejected-Finance H NO 113 APR COLONY KATANGA CANTT JABALPUR M P PIN 482001 | JABALPUR | MADHYA PRADESH | 482001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹45.2 L+₹6.7 L (17.5%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹46.7 L+₹8.2 L (21.2%)Rejected-Finance 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹48.8 L
EMD Value
₹97,600
Closing Date
19 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
PROVN OF CERTAIN LBW, REV AND MINOR WORKS UNDER AGE E/M (W) W/S AND AGE E/M (W) E/S OF GE WEST JABALPUR
2022_MES_525363_2
8442/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (West) Jabalpur
As per Tender documents
5 documents required · 5 mandatory
₹500
GE (West) Jabalpur
₹97,600
29 Aug 2022
20 Jun 2022
21 Jul 2022
20 Jun 2022
19 Jul 2022
27 Jun 2022
21 Jun 2022 - 25 Jun 2022
Amount
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil etc all completed.
M&L for sand cushioning to underground cable providing with a layer 8 cm before laying and 15 cm after laying, jointing and testing the cable all as specified and directed. Note: Punned thickness of sand 18 CM shall be measured for payment.
M&L for Brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed by Engr in charge.
Removing surplus excavated material to a distance not exceeding 50meter above the starting point complete all as specified and directed by Engr in charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr in charge.
Supply, fixing and connecting PVC insulated, round sheathed, multicore, industrial fiexible cable with bright annealed copper conductor, 1100 volts grade cable of size 2.5sqmm, 3 core, confirming to IS 694-1990 complete all as specified and directed
Supply and fix thermoplastic polycarbonate street light juntion box of size 200x160x98mm which is totally safe, shock proof, impact resistant, weather proof, dust proof, rust proof halogen and slica free, having internal embedded gasket technology made of PUR (Make Hensel), complete with IP 65 degree of protection with cable glands (Make AGRO) material polymide in and including the following - Junction box Cat No K- 9255 (box with 5 way Hensel terminal) and having metric knock out on 4 sides ) -01 Nos.cable gland (cat No 1555.32.1.25)M32x1.5, 03 Nos, Lock nut (Cat No 8232, M32x1.5) - 03 Nos, MCB SP, 6 Amps - 01 Nos.
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4.0 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4.0 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core
S&F GI Tubes,of size 40 mm dia light grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
Supply, fixing, connecting and testing of Automatio Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required ilumination level for switching on is < 30 lux and for switching off> 10 lux. The sensor should also have part night operation facility for 4- 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBS should be enclosed in a pole/wall moutaed enclosure made out of kust proof, electric shock proof, termite proof and FR grade SMC Junction box conforming to IP-54, The circuil should be suitable enough to take 8 kw single phase load with contactor 63 Amps conforming to IEC-60947- 4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 63 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 16sqmm coper conductor wire in and including providing of 50x6mm flat iron clamp. necessary nuts and bolts complete etc all as specified and directed by the Engr-in-charge. Make of nature switch - Model No Swadeep-02EC8KW1P of Kakatiya Energy System or equivalent make of Baja/Healer, Make for Contactor- BCH/L&T/Schneider, Make of MCBS- Hager/Schneider/L&T/C&S, Enclouser - Sintax or equivalent.
Disconnecting, dismantling of existing old unserviceable LT Panel/Feeder pillar box and Design, supply. erection, commissioning and testing of outdoor type LT Panel, piatform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main Aluminium bus bars of 630 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 9 tank pre-treatment or surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS 13947. The LT Panel shall be made out of 3 15mm thick CRCA mild steel sheet and 3.00mm thick gland plate, front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. All incoming MCCBS shall be marked with location and rating of MCCBS. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling of old unserviceable LT Panel complere and including the followings:
CONTROL WIRING All control wirings shall have to be carried out with 1100 volts rated FR grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sgmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges.
CABLE ALLEY- Cable alley shall be provided in both side of the panel of suitabie space for all incorning and outgoing cables. Cable terminais shall be provided for conecting of all incoming and outgoing cables, Make of LT Panel : Mc Layer Pvt Ltd, Tricolite, Asian Switchgear
INCOMING - MCCB 250 Amps, 4 pole, 415 volts. 36 KA, 50 Hz. electronicC release Make Legrand -667659 or equivalent make of ABB, Seimens - 01 Nos
OUTGOING (a) MCCB 63 Amps, 4 pole, 415 volts, 25 KA, 50 Hz, thermal magnetic release, Ics= 100%Icu, Make Legrand-420053, ABB, Seimens - 04 Nos.
(b) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos
(c) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 Nos
(d) Current transformer (CT) of rating 630/5, tape wound, rated burden 5 VA - 03 Nos
(e) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply-1set of 03 Nos (Red - 01, Yellow- 01, Blue -01.
(f) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos.
(g) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No.
(h) Danger Notice Plate -02 Nos
(j) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.Cat Part No 412544 of Legrand- 01 Nos.
(k) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos
(l) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved (The panel shall not be less than 2.5 Sqm front area) 'Make of Panel - Asian Switchgear/ Tricolite/Universal Switchgear/ Mc Layer Pvt Ltd
Note: Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.
Dismantling existing ACSR (any size) from over head line completeall as directed by Engr-in-Charge.
Dismantling insulators any type and any size complete all as directed by Engr-in-Charge.
Dismantling of cross arm(made of MS channels / angles etc.) or clamps etc.complete and stacking aside for re-use / replacement all as directed by Engr-in-Charge
Dismantling of stay assembly embedded in concrete and removing materials from site of work complete all as directed by Engineer-in-Charge.
Dismantling of old unserviceable service connection cable with GI wire and reel insulator complete all as directed by Engr-in-Charge.
Dismantling of existing GI earth wire any size complete all as specified and directed
Supplying and fixing,testing the water heater storage type 25 litres, BEE Five star Rated capacity and after connecting electric and water connection and screwing nuts and bolts , anchor hold fast to fixed on wall and making the good the disturbed surface, complete all as required and as directed at site.Make: Bajaj/Racold/Havells.
Supply & fix PVC connection pipe 450mm to 600mm long as required at site complete with PTMT symet nuts on both ends suitable to carry hot water at 60 temp complete all as specified and as directed. Make:- Prayag/ Polytuff/ Shakti
Supply & Fixing single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed.Make- Legrand, L&T,ABB
S & F MCB single pole 240 volts upto 40 Amps, B Series complete all as specified and directed by Engineer in charge. Make- Legrand, L&T,ABB
S&F GI Tubes of size 15mm bore ,ISI MARKED medium grade, galvanised, with all fitting and fixed complete to wall and ceiling or laid in floors complete all as specified and as directed.
S&F stop valves, CP, screwed down, high pressure, with crutch or butterfly handle , screwed both ends for iron pipe or for unions and fixed of size 15mm complete all as specified and as directed.
S&F Bib taps, CP with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule and fixed of size 15mm bore complete all as specified and as directed.
S&F Sub Main Wiring two single core PVC insulated cable of size 4.0 Sqmm multistranded copper conductor two run drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 25mm dia with all conduit fitting,fixing accessories and one run of 2.5 Sqmm multistrand copper conductor cable as continuous earth wire complete all as specified and directed by Engineer in charge Note :- Two Nos of 4.0 Sqmm Wire and one No of 2.5 Sqmm Earth wire in One RM length Measured as one unit length.
S&F Sub Main Wiring two single core PVC insulated cable of size 6.0 Sqmm multistranded copper conductor two run drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 25mm dia with all conduit fitting,fixing accessories and one run of 4.0 Sqmm multistrand copper conductor cable as continuous earth wire complete all as specified and directed by Engineer in charge Note :- Two Nos of 6.0 Sqmm Wire and one No of 4.0 Sqmm Earth wire in One RM length Measured as one unit length.
S&F Exhaust fan heavy duty Plastic body size sweep 300 mm sweep, single phase AC 230 v, 50 Hz , including making hole of required size and making good the disturbed surface and fixing louvers with fitting accessories complete all as specified and directed by Engineer in-charge. Make- Bajaj, Havells,CG
S&F Exhaust fan heavy duty Metal body size sweep 300 mm sweep, single phase AC 230 v, 50 Hz , including making hole of required size and making good the disturbed surface and fixing louvers with fitting accessories complete all as specified and directed by Engineer in-charge. Make- Bajaj, Havells,CG
M&L for one fan point wiring with PVC insulated 1.5 sq mm multi stranded copper conductor cable 1100 volts grade drawn into and including concealed PVC conduit not less than 20mm (ISI marked) including all fitting and fixing accessories fo sunken box in cast iron/pressed steel terminal boxes duly painted with two coats of anticororrrosive paint outside and two coats of aluminium paint inside, 2.8mm thick hylam brand laminated white bakelite sheet cover for mounting of switches, sockets, fan regulators etc and PVC insulated 1.5 Sqmm multistranded copper conductor cable as earth wire and making good the disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engineer in charge.
S & F Switch piano flush type AC 230 volts 5 Amps single pole one way complete all as specified and directed by Engineer in charge.
S&F Ceiling rose surface bakelite 65 mm x50 mm three terminal AC 230 volts flush type complete all as specified and directed by Engineer in charge
S&F sheet steel enclosure 1.6mm thick with hylum shee 3 mm thick with providing 3/6 pin 5/15 amps switch socket combination - 03 Nos with making connection with 2.5 sqmm copper wire with MCB SPN 30 amps with sheet steel enclosure as incoming all as required and directed at site and making good the disturbed surfaces to match with the existing surfaces complete all as specified and directed by Engineer in charge.
S&F sheet steel enclouser distribution boards, double door factory made TPN Vertical 4 way 3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulated copper jumpers of suitable size from the MCCB to the out going circuits one incoming MCCB-100 Amps and MCB TPN 63 A -02 Nos,MCB SP -04 Nos circuits comprising of 3 phase 4 wire of suitable rating all as specified and directed.
S & F sheet metal enclosure MCB DB TPN 4-way type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F MCB TPN 415 volts 63 Amps . complete all as specified and directed by engineer in charge.
Supply,laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc.. all as specified and directed by Engr in Charge.of size 50 mm outer dia and 38 mm inner dia of Make:-Telerex/Tirupati or E-in-C approved
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
S&F the GI earth wire 4 mm dia with fixing all as required and directed at site by Engineer-in-Charge.
Supply and fix Bed Head Panel 2 feet Size BHP as per specification and requirement of site complete all as specified and directed.
Supply and fix Oxygen port, (Oxygen Outlets) gas specific for the services indicated to accept only compatible quick connect Geometric Index type steel adapters as HTM/NFPA standard and as required complete all as specified and directed.
Supply and fix Suction port, ( vacuumOutlets) gas specific for the services indicated to accept only compatible quick connect Geometric Index type steel adapters as HTM/NFPA standard and as required complete all as specified and directed.
Supply and fix Oxygen flow meters with mask made from brass, chrome plated. It shall be back pressure compensated type having housing of Polycarbonate autoclavable reusable flow range 0-15 LPM. Fitted with matching adopter for oxygen outlet point and humidifier shall be compatible with Flowmeter and reusable and as per specifications and as required with suitable steel adopter complete all as specified and directed.
Supply & laying of 12 OD copper pipes, for Medical Gases, complete with elbows, flanges, specials, others fittings, and steel supports. The copper pipe should be of solid drawn seamless deoxidised, un-arsenical, half hard, tempered and of degreased material conforming to BS-EN 1057/13348, of copper pipe with colour coded complete all as specified and directed.
Supply & laying of 15 OD copper pipes, for Medical Gases, complete with elbows, flanges, specials, others fittings, and steel supports. The copper pipe should be of solid drawn seamless deoxidised, un-arsenical, half hard, tempered and of degreased material conforming to BS-EN 1057/13348, of copper pipe with colour coded complete all as specified and directed.
Supply & laying of 22 OD copper pipes, for Medical Gases, complete with elbows, flanges, specials, others fittings, and steel supports. The copper pipe should be of solid drawn seamless deoxidised, un-arsenical, half hard, tempered and of degreased material conforming to BS-EN 1057/13348, of copper pipe with colour coded complete all as specified and directed.
Supply & laying of 42 OD copper pipes, for Medical Gases, complete with elbows, flanges, specials, others fittings, and steel supports. The copper pipe should be of solid drawn seamless deoxidised, un-arsenical, half hard, tempered and of degreased material conforming to BS-EN 1057/13348, of copper pipe with colour coded complete all as specified and directed.
Supply and fix Vacuum Jar with rubber tubings complete with regulator capable of controlling vacuum between 0 to 760 mm Hg and Polycarbonate autoclavable reusable type receiver jar of not less 600 ml. Vacuum regulator shall have a dial gauge, on/off switch, valve control knob and as per specifications and as required. with suitable steel adopter complete all as specified and directed.
Supply and fix Isolation valves 15 mm are to be ball valves, with stainless steel balls and PTFE or Teflon seals. They shall be suitable for a working pressure of 10.2 Kg/cm² gauge. Valves shall be fitted into the pipeline by means of capillary hard soldered joints containing silver. it should be open/close with help of handle with rotation of 90 degreecomplete all as specified and directed.
Supply and fix Isolation valves 22 mm are to be ball valves, with stainless steel balls and PTFE or Teflon seals. They shall be suitable for a working pressure of 10.2 Kg/cm² gauge. Valves shall be fitted into the pipeline by means of capillary hard soldered joints containing silver. it should be open/close with help of handle with rotation of 90 degreecomplete all as specified and directed.
Supply and fix Isolation valves 42 mm are to be ball valves, with stainless steel balls and PTFE or Teflon seals. They shall be suitable for a working pressure of 10.2 Kg/cm² gauge. Valves shall be fitted into the pipeline by means of capillary hard soldered joints containing silver. it should be open/close with help of handle with rotation of 90 degreecomplete all as specified and directed.
Supply and fix Fully Automatic Oxygen Control Panel with the following features: (a) It would be enclosed in a metal cabinet with a hinged cover. The side covers ofthe panel would be made of fiber glass. (b) Panel cover would b efitted with a lock to prevent unauthorized access can be swung open for maintenance. (c) Panel would be fully Automatic Changeover operation and no manual action. (d) Theservice gas would pneumatically operate gas change over system. (e) Delivery of gas through control panel would not be dependent on electricity. (f) Panel would b ecapable of delivering very high flow rate not less than1300 liters per minute at delivery pressure. (g) Panel would have visual indication of the state of the manifold by 3 gauges within the control panel, which would be clearly visible through the transparent cover. (h) Panel would have Audio–Visual alarm indication for changeover of empty cylinder bank to filled cylinder bank Built in transformer to ensure safe operation by low voltage complete all as specified and directed.(CERTIFIED:-18-04-57)
Supply and fix Cylinder Oxygen Manifold for 6+6 cylinder to withstand a pressure of a copper annealed tail pipe with end Brass adapter suitable for oxygen Cylinder and Manifold top frame comprising of high pressure copper pipes, Brass adapter suitable for oxygen Cylinder and Manifold top frame comprising of high pressure copper pipes of with high pressure brass fitting made of high tensile brass and connections through non–returnvalues high pressure copper tail pipes, made of high pressure copper pipe of size . The manifold would be tested (hydraulically) at 3500pig complete all as specified and directed.
Supply and fix junction Box, powder coated & lockable front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position, valve box door cannot be closeed during valve closing position complete all as specified and directed.
Supply and fixing digital alarm system including necessary fittings. complete with and including fittings as required compete all as specified and directed Engr-in-charge.
Supply andlaying MS Pipe heavy grade of ISI marked 150 mm bore for passing of copper pipe laid in under floor, Roads etc. complete with and including fittings as required compete all as specified and directed Engr-in-charge.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in lintels upto 1.5 clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers ,apex stones, bed plates, water troughs and the like including use of formwork (straight or curved) ,including weathering, slightly rounded or chamfered angles and throating, all as specified and as directed (Note :-reinforcement where provided shall be measured and paid seprately)
Cutting chases in brick walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete.
M&L for Prepration of newly metal surfaces of any description n exc 10 cm width or girth and applying two coat of synthetic enamel paint colour coding as per BIS (White,black,blue,yellow etc) complete all as specified.
Supply and fixing vaccum tube PVC transparant and heavy duty including necessary fittings. complete with and including fittings as required complete all as specified and directed Engr-in-charge.
Supply and fixing high pressure tube ( with nut nipple probe and in 3.0 mtr lenth including necessary fittings. complete with and including fittings as required complete all as specified and directed Engr-in-charge.
M/s Ajayshwar Singh Rana
DEEPAK CONSTRUCTION
H V ELECTRICALS
Sachdeva Enterprises
mandeka constructions
ANAMIKA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .