| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹23.5 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹26.7 L+₹3.2 L (13.6%)Rejected-Finance 63 BAJMASTA RAMBAN | RAMBAN | RAMBAN | JAMMU AND KASHMIR | 2 | Rejected-Finance Other than lowest | |
| 3 | 3₹28.1 L+₹4.6 L (19.7%)Rejected-Finance | 3 | Rejected-Finance Other than lowest | |
| 4 | 4₹28.5 L+₹5.0 L (21.3%)Rejected-Finance | 4 | Rejected-Finance Other than lowest | |
| 5 | 5₹28.8 L+₹5.3 L (22.8%)Rejected-Finance | 5 | Rejected-Finance Other than lowest |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
7 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) 873 EWS
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
PROVN OF LPG SHED WITH BITUMEN MASTIC FLOORING AT STAGING AREA DHURMUND GARRISON UNDER GE (I) 873 EWS
2021_MES_475634_1
NIT-46 of 2021-22
Open Tender
Civil Works
Item Rate
180 days
Bhaderwah
As per NIT
7 documents required · 7 mandatory
₹500
GE (I) 873 EWS
₹59,000
Yes
13 Oct 2021
16 Sept 2021
11 Oct 2021
16 Sept 2021
7 Oct 2021
30 Sept 2021
60 days
Amount
B/R Portion
Surface Excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Rough excavation n exc 1.50m deep and getting out in any type of soil soil, complete all as specified & directed.
Excavation over areas not exc. 1.5m deep in any type of soil and getting out, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Plain Cement concrete type D-2, 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Walling of random rubble stone masonry, well bonded, bedded and solidly hearted built in cement mortar 1:6, uncoursed, complete all as specified and directed. Note : Volume of PCC bond stone shall be deducted from total cumulative quantity of stone masonry.
Precast cement concrete, type C-1 1:3:6 (using 20mm graded crushed stone aggregates) as in bond stone set in cement mortar 1:6 and finishing exposed surfaces including necessary form work, complete all as specified and as directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought up to courses with maximum depression on face from straight edge held against the dressed surface not exceeding 40mm, complete all as specified and as directed.
Raised pointing to random rubble masonry, uncoursed or brought up to courses in cement mortar 1:4, complete all as specified and directed.
Plain cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in cills, lintels up to 1.5 metre clear span, steps, seismic and other similar band, plinth course, string courses, lacing courses, parapets and railing up to 60cm in height, copings, kneelers, apex stone, bed plates, kerbs etc and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form work complete, all as specified and as directed.
PVC (SWR) pipes, 110mm dia, fixed to retaining wall as in weep hole, complete all as specified & directed.
Hand packing (any thickness) using broken stone or boulders at back of walls over arches etc., and raising (or lowering) to the required level, complete all as specified.
Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in in CM 1:6, complete all as specified and directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts, complete all as specified and as directed.
RCC M-25 (design mix) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
RCC M-30 (design mix) in chajjas, complete all as specified and as directed.
Formwork to sides of concrete foundation, footings, bases of columns, rafts and raft beams and similar work; vertical or to batter for rough finished surfaces of concrete, complete all as specified and as directed.
Formwork to sides of pillars, posts, struts, columns (square, circular rectangular on plan or polygonal etc. for rough finished surfaces of concrete, complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of concrete, complete all as specified and as directed.
Form work to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete, complete all as specified & directed.
TMT bars 10mm dia and over, cut to length bent to shape including binding with MS annealed wire of dia not less than 0.90 mm, complete, all as specified and as directed.
TMT bars 6 to 8mm dia as in stirrups, cut to length bent to shape including binding with MS annealed wire of dia not less than 0.90 mm, complete all as specified and as directed.
Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified.
Rendering 15mm thick in cement mortar 1:6 on other than fair face of brickwork or on one side of lathing, finished even and smooth without using extra cement, complete all as specified.
Hard core of broken stone gauge exceeding 63mm and not exceeding 100mm deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surfaces, complete, all as specified and as directed.
75mm thick PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in sub base of flooring finished even and rough, to receive floor finishes, complete all as specified and as directed.
25mm thick PCC 1:2:4, type B-0 (using 12.5mm graded crushed stone aggregate) as in floor, finished rough to receive tiles above, complete all as specified & directed.
100mm thick PCC 1:2:4, nominal mix, type B1, using 200mm graded crushed stone aggregate as in hardstanding, ramp, path etc. (laid in alternate bays where directed) surface finished even and fair without using extra cement, complete all as specified
25mm thick non-sparkable bitumen mastic flooring formed with a mixture of fine aggregate, coarse aggregate, lime stone, carbon black/graphide and pigment thoroughly mixed with hand grade bitumen 10% to 18% by weight of total mass , cooked and laid hot, troweled and floated by means of wooden float, complete all as specified in SSR 2009 Part-1 and as directed.
Steel windows Steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel, complete all as specified and as directed by Engr-in Charge.
Mild steel framed works such as grills, framed guard bars, etc. and similar work conforming to Fe-410-O or Fe-310-O grade, including bending, cutting and welding as required, complete all as specified and as directed.
Mild steel rolled work as in doors or gates of angle or other section with gusset plates, rails, braces, eaves board etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-290 grade-E-165, complete all as specified and directed.
0.80mm thick Mild steel, plain, black sheet in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or elded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required, complete all as specified and directed.
3mm thick sheet glass ordinary quality and glazing with oil putty / screws, in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Mild steel rolled work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (beam, tee, angle, square / rectangle sections, channel or flat section) including distance pieces, cleats etc. confirming to grade FE 410-0 complete all as specified and directed.
Mild steel plates (plain or chequered) channel, square cut or notched (Ordinary and counter sunk) forming holes, without any attachment as in gusset plates all as specified and directed.
Pre-painted galvalume aluminium zinc coating G.I based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering, fixed with self taping screws, complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating G.I based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering / cladding to wall, fixed with self taping screws, complete all as specified and directed.
Preparation new plastered or previously untreated surfaces of walls and applying three coats of white wash , complete all as specified and directed.
Preparation new plastered surfaces of walls and applying two coats of cement base paint including one coat of cement primer complete all as specified and directed.
Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed.
E/M Portion
Air termination single pointed aluminum rod 12mm dia and 300mm long, complete all as specified.
Aluminum strip 25x3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground, complete all as specified.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hex head screw, complete all as specified.
Excavation in post holes (or similar holes) each not exc. 0.50 cum, in any type of soil and getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc. 25cm, watering and removal of excavated materials to a distance n. exc. 50m and making good surfaces, complete all as specified & directed.
GI tubing ‘medium grade’ with all fittings, fixed as in posts as directed, bore of pipe 40mm, complete all as specified.
Plain Cement concrete type C-2, 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation of poles, etc, complete all as specified and directed.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL) connected to galvanized iron strip 25mmx4mm by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 40mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
M S BANSI LAL CONSTRUCTION CO
M/S HAJI MOHD SHAFI AND SONS
N S MANHAS
M/S SHREE KRISHANA ENERPRISES
BALVINDER SINGH AND SONS
AKSHAY CONSTRUCTION COMPANY
RAJINDRA ENGINEERS & CONTRACTORS
Bidder Name
N S MANHAS
AKSHAY CONSTRUCTION COMPANY
M S BANSI LAL CONSTRUCTION CO
M/S DHARAM PAUL GUPTA
RAJINDRA ENGINEERS & CONTRACTORS
BALVINDER SINGH AND SONS
M/S HAJI MOHD SHAFI AND SONS
M/S SHREE KRISHANA ENERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .