| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC 00 KIWADI SAFEDABAD BARABANKI BARABANKI UTTAR PRADESH 225001 | BARABANKI | UTTAR PRADESH | 225001 | L1 | Accepted-AOC L1 bidder is techno commercially qualified. | |
| 2 | L2₹12.4 L+₹18,930 (1.55%)Rejected-Finance AT BALU BANKER COLONY PO DHORI BERMO DIST BOKARO JHARKHAND | BOKARO | JHARKHAND | 825102 | L2 | Rejected-Finance Bid not be opened as per NIT terms. | |
| 3 | Rejected-Technical AT KARGALI BAZAR BERMO DIST BOKARO PIN NO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | - | Rejected-Technical Technically disqualified | |
| 4 | Rejected-Technical C O VOLTAS LIMITED SPARE PARTS DEPOT OLD HUTMENT COLONY NCL NIGAHI SINGRAULI M P 486884 | SINGRAULI | SINGRAULI | MADHYA PRADESH | 486884 | - | Rejected-Technical Technically disqualified |
Tender Value
₹13.3 L
EMD Value
₹16,600
Closing Date
3 Feb 2025, 10:00 amClosed
SO(EnM), Dhori
Office of the General Manager, Dhori , Po- Dhori, pin-825102
Repair and maintenance of 11KV OH line from Dhori Sub-station to CCD Sub-station along with replacement of damaged insulator, stay sets, pole and conductor in jungle area under CCD, G.M. unit, Dhori Area
2025_CCL_326372_7
GM(D)/SO(EnM)/DA/24-25/61
Open Tender
Electrical and Maintenance Works
Item Wise
20 days
CCD
please refer tender documents
2 documents required · 2 mandatory
₹16,600
1 Apr 2025
22 Jan 2025
4 Feb 2025
23 Jan 2025
3 Feb 2025
23 Jan 2025
23 Jan 2025 - 30 Jan 2025
Amount
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling and secured with as required : Above 10.00 Mtrs. & upto 12.00 Mtrs.
Supplying and erection of galvanized stay set for 11KV overhead lines complete with 19/20mm dia x 1.8 metres long stay rod, anchor plate of size 45cm x 45cm x 7.5mm thick, thimble, stay clamps, turn buckle (20mm x 600mm), 7/4.00mm dia G.I. stay wire and 11KV strain insulator etc. in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required.
Erection of ACSR conductor of 7/3.35mm to 7/4.00 diameter and above including binding etc. as required.
Dismantling of overhead lines comprising of copper/aluminium overhead conductor, G.I. wire cross arms, insulators etc. as required.
Clearing jungle including uprooting of rank vegetation, grass, Brush wood, trees and saplings of girth upto 30cm measured at a height of 1M above ground level and removal of rubbish upto a distance of 50M outside the periphery of the area cleared.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. : With ready mixed red oxide zinc chromatic on steel / iron works having VOC content less than 250 grams/ litre
Painting with aluminium paint of approved brand and manufacture to give an even shade : Two or more coats on new work.
8 SWG GI wire (4.0mm dia) (+) Erection of GI wire no. 8 SWG including binding etc. as required. 40 x 50 x 3 x 0.103
Erection of cradle guard as required 32 span x 30 nos.
Supplying and erection of 11KV pin Insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of 11KV disc insulator for 11KLV overhead lines with galvanized insulator fittings, ball and socket type and complete with galvanized strain clamps, bolts, nuts, washers etc. as required.
Supplying of two lengths of channel iron 75mm x 40mm x 6mm (7.14kg per metre) double pole cross arm for three wire 11KV overhead line conductors complete with through bolts and nuts for clamping of the poles, 50mm x 6mm N.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/fittings, bolts, nuts and washers etc. (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/22KV/33KV overhead lines as required.
Transporting of pole.
Dismantling of pole embedded in cement concrete foundation etc. as required.
Supplying and erection of 33KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Repairing of GOS 400 Amp.
Supply of female contact of GOS 400 A.
Supply of male contact of GOS 400 A.
Total impact of GST for the purpose of CTC
M/S UPENDRA ELECTRICAL (BID ID -1123803)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .