| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.1 LAccepted-AOC | ₹43.1 L | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹43.1 LSame as L1Rejected-AOC | ₹43.1 LSame as L1 | L2 | Rejected-AOC L2 |
Tender Value
₹47.8 L
EMD Value
₹95,680
Closing Date
28 Nov 2023, 2:00 pmClosed
CE, PWD(Roads), Assam, Chandmari, Ghy-3
O/O The CE, PWD(Roads), Assam, Chandmari, Ghy-3
Package No. KAMRUP METRO/MMPNA/R_R/02 Repair and Rehabilitation of the bridges 1) located at G.G. Road (Paltanbazar Bijuli Bhawan Police Point- Lokhra NH 37 near Nepali Mandir at Ch. 0.4887 km , 2) located at Rajgarh bridge near Aruna Menorial Hospi
2023_PWD_34035_2
CE/STBR/MMPNA/R_R/09/2023-24/1 Dated 29-09-2023
Open Tender
Civil Works – Roads
Item Rate
180 days
Kamrup(M)
Please refer Tender documents.
5 documents required · 5 mandatory
₹957
₹95,680
Yes
24 Apr 2024
18 Nov 2023
29 Nov 2023
18 Nov 2023
28 Nov 2023
18 Nov 2023
18 Nov 2023 - 28 Nov 2023
Amount
1) located at G.G. Road (Paltanbazar Bijuli Bhawan Police Point- Lokhra NH 37 near Nepali Mandir at Ch. 0.4887 km Chipping of deteriorated concrete and removal of all loose & friable materials and fully exposing rusted reinforcement followed by proper cleaning and removing of rusts and other foreign materials using sand blasting/ emery cloths/ wire brush etc. including formwork as directed and specified by the department complete
Replacement of corroded reinforcement by cutting and welding new reinforcement of minimum 25mm dia. including lapping on both sides to the specified length as directed and as per relevant IS/IRC codes and cost of gas ,welding rods,higher charge of welding machines etc. including formwork as required.(Reinforcement to be measured and paid seperately)
Supplying and applying two coats of Zinc rich anti-corrosive protective coating with "Nitozinc primer" of Fosroc or euivalent @ 0.20 Lit per Sqm over thoroughly cleaned and prepared steel bars including formwork as directed and specified by the department complete.
Supplying and applying Epoxy based bonding agent Nitobond EP of Fosroc Chemicals or MasterBrace 1414 of BASF or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface with clean water for proper bonding of old and new concrete including formwork as specified and directed by the department complete.
Patching of damaged concrete surface with structural grade polymer modified reinstatement mortar to like Fosroc Renderoc S2 or equivalent at a thickness of 10 to 20mm as per instructions of manufacturer and as approved by the Engineer.The prepacked repair mortar should have a compressive strength 45 N/mm²,Flexture strength 8 N/mm² at 28 Days.
Concreting of the structure with free flow nonshrink cementitious microconcrete with Renderoc RG of Fosroc or equivalent after proper mixing with cleanwater including formwork followed by proper curing for 28 days as per manufacturer's specifications complete and as directed by the Department .
'Repair of joint Grooves with Epoxy Mortar Repair of spalled joint grooves of contraction joints, longitudinal joints and expansion joints in concrete pavements using epoxy mortar or epoxy concrete)
Providing & fixing 16mm dia MS nozzles in a grid of 1m c/c up to the half of the thickness of the concrete structure.A grout slurry of neat cement & chloride free expanding grout Cebex 100 of Fosroc Chemicals or Mastergrout CPG-1 of Choksey Chemicals or MasterFlow 150 of BASF or equivalent @ 0.5% by weight of cement water cement ratio 0.35 to 0.40 and viscosity not more than 1.02 centipoise with grouting pressure till the refusal of injection grout . The grouting operation pressure shall be 2Kg/sq.cm.Cutting the exposed nozzle after the grouting with a good cutter to make the surface free from the grouting pipes and to seal the gap with plugging compound Masterplug of Choksey Chemicals as per the specification and the direction of the department complete including formwork.
Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy
Sealing of crack / porous concrete with Epoxy Grout by injection through nipples complete as per clause 2803.1.
Supply and fixing of rebarring chemical FOSROC LOKFIX E75- pure Chemical anchor grout or equivalent for various diameters of reinforcement bar provide embedment depth as per the manufacturer’s specifications and instructions for use in concrete applications as directed by Engineer in charge. a) 8mm dia rebar at 120mm depth
Supply and fixing of rebarring chemical FOSROC LOKFIX E75- pure Chemical anchor grout or equivalent for various diameters of reinforcement bar provide embedment depth as per the manufacturer’s specifications and instructions for use in concrete applications as directed by Engineer in charge. a) 12mm dia rebar at 120mm depth
Supplying, fitting and placing TMT bar reinforcement in sub-structure complete as per drawing and technical specifications (ii)Super Ductile (SD) TMT reinforcement bar of Fe-500 N/mm2
Providing and applying Deckguard E 2000 or Masterseal 878 of BASf or equivalent a High Performance Anticarbonation Protective Coating System, over the prime surface using an airless spray or roller at right angles to each other @ coverage of 5 Sqm per litre per coat @ 200 microns wft / 100 microns DFT with an intercoat period of minimum 12 hrs @ 35ºC. The coverage per litre for 2 coats shall be 2.5 Sqm @ 200 microns DFT. The protective coating system should have CO2 diffusion resistance not less than 240mm equivalent of air thickness and 60cm equivalent of 30N concrete along with a water vapour transmission resistance of less than 1.0 metre (Taywood method), the coating should have static crack accommodation of not less than 2mm (BRE) and adhesion greater than 1.0 N/mm² as per BS 1881.
Non-destuctive testing with Ultrasonic Pulse Velocity Meter with data storage facility for detection of cracks, voids and other imperfections in Reinforced concrete structures and furnishing the findings thereof in proper comprehensible format , complete as directed by the department.
Conducting Concrete Core tests of 75mm diacores, on concrete stucture, as per stipulated procedures, for determination the equivalent cube compressive strength, concrete of the structures including preparation and furnishing the report showing the findings thereof in proper comprehensible format , complete as directed by the department.
2) bridge located at Rajgarh bridge near Aruna Menorial Hospital on Rajgarh Road Chipping of deteriorated concrete and removal of all loose & friable materials and fully exposing rusted reinforcement followed by proper cleaning and removing of rusts and other foreign materials using sand blasting/ emery cloths/ wire brush etc. including formwork as directed and specified by the department complete
Replacement of corroded reinforcement by cutting and welding new reinforcement of minimum 25mm dia. including lapping on both sides to the specified length as directed and as per relevant IS/IRC codes and cost of gas ,welding rods,higher charge of welding machines etc. including formwork as required.(Reinforcement to be measured and paid seperately)
Supplying and applying two coats of Zinc rich anti-corrosive protective coating with "Nitozinc primer" of Fosroc or euivalent @ 0.20 Lit per Sqm over thoroughly cleaned and prepared steel bars including formwork as directed and specified by the department complete.
Supplying and applying Epoxy based bonding agent Nitobond EP of Fosroc Chemicals or MasterBrace 1414 of BASF or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface with clean water for proper bonding of old and new concrete including formwork as specified and directed by the department complete.
Patching of damaged concrete surface with structural grade polymer modified reinstatement mortar to like Fosroc Renderoc S2 or equivalent at a thickness of 10 to 20mm as per instructions of manufacturer and as approved by the Engineer.The prepacked repair mortar should have a compressive strength 45 N/mm²,Flexture strength 8 N/mm² at 28 Days.
Concreting of the structure with free flow nonshrink cementitious microconcrete with Renderoc RG of Fosroc or equivalent after proper mixing with cleanwater including formwork followed by proper curing for 28 days as per manufacturer's specifications complete and as directed by the Department .
'Repair of joint Grooves with Epoxy Mortar Repair of spalled joint grooves of contraction joints, longitudinal joints and expansion joints in concrete pavements using epoxy mortar or epoxy concrete)
Providing & fixing 16mm dia MS nozzles in a grid of 1m c/c up to the half of the thickness of the concrete structure.A grout slurry of neat cement & chloride free expanding grout Cebex 100 of Fosroc Chemicals or Mastergrout CPG-1 of Choksey Chemicals or MasterFlow 150 of BASF or equivalent @ 0.5% by weight of cement water cement ratio 0.35 to 0.40 and viscosity not more than 1.02 centipoise with grouting pressure till the refusal of injection grout . The grouting operation pressure shall be 2Kg/sq.cm.Cutting the exposed nozzle after the grouting with a good cutter to make the surface free from the grouting pipes and to seal the gap with plugging compound Masterplug of Choksey Chemicals as per the specification and the direction of the department complete including formwork.
Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy
Sealing of crack / porous concrete with Epoxy Grout by injection through nipples complete as per clause 2803.1.
Supply and fixing of rebarring chemical FOSROC LOKFIX E75- pure Chemical anchor grout or equivalent for various diameters of reinforcement bar provide embedment depth as per the manufacturer’s specifications and instructions for use in concrete applications as directed by Engineer in charge. a) 8mm dia rebar at 120mm depth
Supply and fixing of rebarring chemical FOSROC LOKFIX E75- pure Chemical anchor grout or equivalent for various diameters of reinforcement bar provide embedment depth as per the manufacturer’s specifications and instructions for use in concrete applications as directed by Engineer in charge. a) 12mm dia rebar at 120mm depth
Supplying, fitting and placing TMT bar reinforcement in sub-structure complete as per drawing and technical specifications (ii)Super Ductile (SD) TMT reinforcement bar of Fe-500 N/mm2
Providing and applying Deckguard E 2000 or Masterseal 878 of BASf or equivalent a High Performance Anticarbonation Protective Coating System, over the prime surface using an airless spray or roller at right angles to each other @ coverage of 5 Sqm per litre per coat @ 200 microns wft / 100 microns DFT with an intercoat period of minimum 12 hrs @ 35ºC. The coverage per litre for 2 coats shall be 2.5 Sqm @ 200 microns DFT. The protective coating system should have CO2 diffusion resistance not less than 240mm equivalent of air thickness and 60cm equivalent of 30N concrete along with a water vapour transmission resistance of less than 1.0 metre (Taywood method), the coating should have static crack accommodation of not less than 2mm (BRE) and adhesion greater than 1.0 N/mm² as per BS 1881.
Non-destuctive testing with Ultrasonic Pulse Velocity Meter with data storage facility for detection of cracks, voids and other imperfections in Reinforced concrete structures and furnishing the findings thereof in proper comprehensible format , complete as directed by the department.
Conducting Concrete Core tests of 75mm diacores, on concrete stucture, as per stipulated procedures, for determination the equivalent cube compressive strength, concrete of the structures including preparation and furnishing the report showing the findings thereof in proper comprehensible format , complete as directed by the department.
Bridge located at Sati Joymati Road (Sarabbhati Police Point - AT Road Athgaon) Chipping of deteriorated concrete and removal of all loose & friable materials and fully exposing rusted reinforcement followed by proper cleaning and removing of rusts and other foreign materials using sand blasting/ emery cloths/ wire brush etc. including formwork as directed and specified by the department complete
Replacement of corroded reinforcement by cutting and welding new reinforcement of minimum 25mm dia. including lapping on both sides to the specified length as directed and as per relevant IS/IRC codes and cost of gas ,welding rods,higher charge of welding machines etc. including formwork as required.(Reinforcement to be measured and paid seperately)
Supplying and applying two coats of Zinc rich anti-corrosive protective coating with "Nitozinc primer" of Fosroc or euivalent @ 0.20 Lit per Sqm over thoroughly cleaned and prepared steel bars including formwork as directed and specified by the department complete.
Supplying and applying Epoxy based bonding agent Nitobond EP of Fosroc Chemicals or MasterBrace 1414 of BASF or euivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface with clean water for proper bonding of old and new concrete including formwork as specified and directed by the department complete.
Patching of damaged concrete surface with structural grade polymer modified reinstatement mortar to like Fosroc Renderoc S2 or equivalent at a thickness of 10 to 20mm as per instructions of manufacturer and as approved by the Engineer.The prepacked repair mortar should have a compressive strength 45 N/mm²,Flexture strength 8 N/mm² at 28 Days.
Concreting of the structure with free flow nonshrink cementitious microconcrete with Renderoc RG of Fosroc or equivalent after proper mixing with cleanwater including formwork followed by proper curing for 28 days as per manufacturer's specifications complete and as directed by the Department .
'Repair of joint Grooves with Epoxy Mortar Repair of spalled joint grooves of contraction joints, longitudinal joints and expansion joints in concrete pavements using epoxy mortar or epoxy concrete)
Providing & fixing 16mm dia MS nozzles in a grid of 1m c/c up to the half of the thickness of the concrete structure.A grout slurry of neat cement & chloride free expanding grout Cebex 100 of Fosroc Chemicals or Mastergrout CPG-1 of Choksey Chemicals or MasterFlow 150 of BASF or equivalent @ 0.5% by weight of cement water cement ratio 0.35 to 0.40 and viscosity not more than 1.02 centipoise with grouting pressure till the refusal of injection grout . The grouting operation pressure shall be 2Kg/sq.cm.Cutting the exposed nozzle after the grouting with a good cutter to make the surface free from the grouting pipes and to seal the gap with plugging compound Masterplug of Choksey Chemicals as per the specification and the direction of the department complete including formwork.
Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy
Sealing of crack / porous concrete with Epoxy Grout by injection through nipples complete as per clause 2803.1.
Supply and fixing of rebarring chemical FOSROC LOKFIX E75- pure Chemical anchor grout or equivalent for various diameters of reinforcement bar provide embedment depth as per the manufacturer’s specifications and instructions for use in concrete applications as directed by Engineer in charge. a) 8mm dia rebar at 120mm depth
Supply and fixing of rebarring chemical FOSROC LOKFIX E75- pure Chemical anchor grout or equivalent for various diameters of reinforcement bar provide embedment depth as per the manufacturer’s specifications and instructions for use in concrete applications as directed by Engineer in charge. a) 12mm dia rebar at 120mm depth
Supplying, fitting and placing TMT bar reinforcement in sub-structure complete as per drawing and technical specifications (ii)Super Ductile (SD) TMT reinforcement bar of Fe-500 N/mm2
Providing and applying Deckguard E 2000 or Masterseal 878 of BASf or equivalent a High Performance Anticarbonation Protective Coating System, over the prime surface using an airless spray or roller at right angles to each other @ coverage of 5 Sqm per litre per coat @ 200 microns wft / 100 microns DFT with an intercoat period of minimum 12 hrs @ 35ºC. The coverage per litre for 2 coats shall be 2.5 Sqm @ 200 microns DFT. The protective coating system should have CO2 diffusion resistance not less than 240mm equivalent of air thickness and 60cm equivalent of 30N concrete along with a water vapour transmission resistance of less than 1.0 metre (Taywood method), the coating should have static crack accommodation of not less than 2mm (BRE) and adhesion greater than 1.0 N/mm² as per BS 1881.
Non-destuctive testing with Ultrasonic Pulse Velocity Meter with data storage facility for detection of cracks, voids and other imperfections in Reinforced concrete structures and furnishing the findings thereof in proper comprehensible format , complete as directed by the department.
Conducting Concrete Core tests of 75mm diacores, on concrete stucture, as per stipulated procedures, for determination the equivalent cube compressive strength, concrete of the structures including preparation and furnishing the report showing the findings thereof in proper comprehensible format , complete as directed by the department.
RAJKAMAL SINGHA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .