Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹17.0 L+₹5,590 (0.33%)Rejected-Finance | L2 | Rejected-Finance Other than L1 Bidder | |
| 3 | L3₹19.9 L+₹3.0 L (17.4%)Rejected-Finance | L3 | Rejected-Finance Other than L1 Bidder | |
| 4 | L4₹22.8 L+₹5.9 L (34.5%)Rejected-Finance MAHALAXMI ENCLAVE OPPOSITE SLP COLLEGE MORAR GWALIOR MP | GWALIOR | GWALIOR | MADHYA PRADESH | L4 | Rejected-Finance Other than L1 Bidder | |
| 5 | L5₹25.2 L+₹8.2 L (48.3%)Rejected-Finance | L5 | Rejected-Finance Other than L1 Bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
11 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Gwalior
Garrison Engineer Morar Cantt Gwalior
8685/GWL/E8 CLEANING AND REPAIR OF SEWAGE LINE INCLUDING CONNECTED WORKS IN THE AREA OF AGE B/R-II UNDER GE GWALIOR
2021_MES_465206_1
8685/GWL/E8
Open Tender
Civil Works
Works
365 days
Garrison Engineer Gwalior
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer
₹40,000
Yes
9 Oct 2021
4 Aug 2021
20 Sept 2021
4 Aug 2021
11 Sept 2021
21 Aug 2021
4 Aug 2021 - 14 Aug 2021
60 days
Amount
Taking of liquid/solid content from sump/septic tank either manually or by pumping clearing thoroughly including disposal of liquid/solid content out of the Cantt Area ,depositing in pit and covering with layers of earth and taking all precautions against foul/hazzardous gas etc, complete all as specified and directed . (Notes :- (i) Volume occupied by silt/sludge & other deposits (Semi solids) shall only be measured and paid for against the item. (ii) Volume occupied by effluent (liquid/ waste water above silt/sludge & other deposits) shall not be measured and paid. However quoted rates shall be deemed to be includde for bailing out of effluent.)
Demolition of brick work or stone/ boulder masonry built in cement mortar or cement lime mortar in existing manholes / septic tank, sumps ,soakage pits including all quoins, arches, pillars etc complete all as specified and as directed.
M&L for Brick work with sub class B bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:6).complete all as specified and as directed.
M&L, 15mm thick rendering on any faces of stone, concrete or brick work in CM 1:4 mixed with water proofing compound as per manufacturer instruction , surface finished even and fair complete all as specified and as directed. Note:- Integral water proofing compound shall be measured and paid for separately under respective items.
M&L,precast cement concrete 1:2:4 type B1 using 20mm graded stone agregate including necessary form work as in manholes cover slab etc, set in cement mortar 1:4 complete all as specified and as directed. (Note :- Re-inforcement shall be measured and paid for separately under respective items of Sch 'A' here in after)
M&L for mild steel TMT 6 to 8mm dia cut to length bent to shape required including cranking etc and binding with MS wire (annealed) not less than 0.9mm dia complete all as directed by Engr-in-Charge
Excavating in trenches in any type of soil , n exc 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soil complete all as specified and as directed.
Excavating in trenches in any type of soil , n exc 1.5 m wide and exc. 1.5 m in deep and n.exc 3.0m deep for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out soil complete all as specified and as directed.
Returning, filling in, including spreading ,leveling, watering and well ramming in layers n. exc 25 cm with soil complete all as specified and as directed.
Removal of excavated material (soil) to a distance n. exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed.
M&L, PCC 1:4:8 type D2 using 40mm graded stone aggregate as in concrete bed to drain pipes of 100 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; including necessary form work complete all as specified and as directed.
M&L, PCC 1:4:8 type D2 using 40mm graded stone aggregate as in concrete bed to drain pipes of 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; including necessary form work complete all as specified and as directed.
M&L, PCC 1:4:8 type D2 using 40mm graded stone aggregate as in concrete bed to drain pipes of 200 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; including necessary form work complete all as specified and as directed.
S&F for reinforced concrete pipes 150mm bore class NP-2 laid and jointed with collar in CM 1:1 complete all as directed by Engr-in-Charge
All as per item No. 14 but 200mm dia of pipe.
All as per item No. 14 but 100mm dia of pipe.
M&L, 50mm thick rough dressed sand stone as in manholes covers, any shape set and jointed in CM 1:6 complete all as specified and as directed.
M&L, PCC 1:4:8 type D2 ,using 40mm graded sand stone aggregate as in base of manholes or in mass concrete complete all as specified and as directed.
M&L, PCC 1:2:4 type B1 using 20mm graded stone aggregate as in bed block, coping / surface channel and the like including weathering, slightly rounded or chamfered angles and throating, including form work complete all as specified and as directed.
M&L ,forming fair finish to drain or channel surface n.exc 30cm inner girth in cement concrete with using extra cement complete all as specified and directed.
Add or deduct of each 25mm girth or part thereof over or under 30cm inner girth in cement concrete using extra cement complete all as specified and directed.
M&L,cutting into existing manholes for connecting new drains of 150 mm internal dia of pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and as directed.
M&L,cutting into existing manholes for connecting new drains of 200 mm internal dia of pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and as directed.
Dismantaling of rain water / vent / waste pipes, any type any size including all fittings complete all as specified and as directed.
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed.
S&F, 110 mm bore PVC (SWR) pipes, single socketed in any length with laid in trenches ,wall and floors. complete all as specified and as directed
S&F, 75mm bore PVC (SWR) pipes, single socketed in any length fixed to walls with necessarycomplete all as specified and as directed.
S&F for 110mm dia PVC(SWR)pipes junction,single (single T/Y ) equal or unequal any radious, complete all as specified and directed.
S&F, 110 mm dia PVC (SWR) bends any radius complete all as specified and as directed.
S&F, 75 mm dia PVC (SWR) bends any radius complete all as specified and as directed.
S&F, 110 mm dia PVC (SWR) bends any radius complete all as specified and as directed.
S&F, 75 mm dia PVC (SWR) bends any radius complete all as specified and as directed.
S&F, 110 mm dia, PVC (SWR) junction single, (single T) complete all as specified and as directed.
S&F, 75 mm dia, PVC (SWR) junction single (single T) complete all as specified and as directed.
M&L for surface dressing n exc 15 cm deep inluding cutting bushess, wages, hages etc and removing to as directed by Engr In Charge complete all as specified and directed.
M&L for digital glazed ceramic tiles, coloured tiles 300mm x 450mm x 7mm thick on vertical faces ie. as in skirting/dado etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles fix over and including 10 mm thick backing coat in cement mortar (1:3) complete (or match with existing) all as specified and directed.
M&L for non skid ceramic Coloured tiles, 300mm x 300mm x 6mm to 7mm thick, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match with the colour of tiles, over and including 15 mm thick screed bed or bedding layer of cement mortar( 1:6) (or match with existing) complete all as specified and directed.
S&F, 110 mm bore PVC (SWR) vent cowl, complete all as specified and as directed.
M&L, cleaning blockage by manually or mechanically in sewage line up to 4.5 mtr depth, WC GT, NT, FT & man holes in entire Field Bty Line, CTC Line & Residency , Gole Ka Mandir incl MAP Bldg & NCC under AGE B/R-II by engagging min two safai wala for each Zone on all working days from 830hr to 1700 hrs alonng with T&P ie. gum boot, mask, safety device etc. as required for cleaning blockage and keep smooth functional the entire sewage lines including manholes to the entire stisfation of Engineer-in-Charge etc and all as specified and diected . Note for sch À'item above (i) Contractor's supervisor will report on all working days along with six safai wala (two for each Fd Bty Line & CTC Area, two for Residency Area and two for Gole Ka Mandir & NCC OTA etc Area) at 0830 hrs at B/R maintainance cell to receive complaint for blockage and to submit complition report on same day by 1700 hrs. (ii) Printed complaint slip Area wise as per format approved by Engineer-in-Charge shall be provided and maintained by contractor. Cost for the same shall deemed inclusive in the quited rate. (iii) Rate quoted above shall be deemed to incl the cost of adequate T&P, equipment, safety device etc alongwith sufficient labour to full fill the requirement to the entire satifaction of Engr-in-Charge. Any despute related to above shall be resolved by Garrison Engineer and his decesion shall be final, binding and conclusive. (iv) If there is any major blockage in sewer line for which additional Safaiwalas and special T&P is required same shall be provided by contractor without any extra cost to Govt there fore contractor is advice to visit the site before quoting the rate in tender. (v) All sewage blokage complaint must be attended within 24 hrs. any sewage blokage complaint is not clear within 24hr( except and otherwise few major/ Difficult complaint prior intimation/ notice to GE/ Engr In Charge) compensation of Rs.100/- per Day per complaint shall be charged from contractor work done without any prior notice based on Job card i.e. user satisfaction.
S&F, in repair vitreous china wash down water closet pan (pedestal pattern) EWC white or coloured with matching plastic water closet seat, black closed pattern with flat bottam and cover & mild steel cromium plated or a lumining hinging device complete all as specified and as directed.
S&F, in repairs vitreous china squatting pan “Orissa Pattern” of size 580 x 440mm white or coloured with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes and 'P' or 'S' etc including lime concrete bedding complete all as specified in SSR complete as specified and as directed.
S&F for in repair PVC valveless syphonic action type flushing cistern low level white with inlet ball valve,float end handle handle including bracket complete of capacity 10 litres, complete all as specified and directed.
Demolition of concrete of any description and in position not otherwise specially provided for complete all as secified and directed.
M&L for cement concrete 75mm thick 1:3:6 type C-2, (40mm graded aggregate ) as in plinth protection/path/paving finishing concrete surface fair and even with out using extra cement complete all as specified and as directed by Engr-in-Charge.
M&L for 10mm thick rendering on any faces of stone, concrete or brick work in CM 1:4 complete all as specified and as directed by Engr-in-Charge.
Supply only water proofing compound (ISI Mark) complete all as specified and as directed.
GURU KIRTH BUILDERS
M/s Manish Contractor
M.S. ENGINEERS
mahamaya constructions
Babatia super works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .