| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC DAYA BAGH SATTANI DHAR ROAD UDHAMPUR DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹18.5 L+₹1.8 L (10.6%)Rejected-AOC GROUND FLOOR MH ROAD UDHAMPUR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC OK | |
| 3 | L3₹18.7 L+₹2.0 L (11.9%)Rejected-AOC WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC OK | |
| 4 | L4₹20.8 L+₹4.1 L (24.6%)Rejected-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-AOC OK | |
| 5 | L5₹20.9 L+₹4.2 L (25.1%)Rejected-AOC | L5 | Rejected-AOC OK |
Tender Value
₹24.4 L
EMD Value
₹48,700
Closing Date
9 Jul 2024, 6:00 pmClosed
GE Army Dhar Road
GE Army Dhar Road
REPAIR MAINT REPLACEMENT OF SECURITY LIGHT HIGH MAST LIGHT FLOOD LIGHTS BAY LIGHTS POST TOP LANTERN ETC AND OTHER CONNECTED WORKS INCL REPAIR AND MAINT OF LIGHTENING CONDUCTOR INFRASTRUCTURE AT JINDRAH UNDER GE ARMY DHAR ROAD
2024_MES_659165_1
8070/NIT-48/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE Army Dhar Road
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE Army Dhar Road
₹48,700
Yes
24 Sept 2024
11 Jun 2024
11 Jul 2024
12 Jun 2024
9 Jul 2024
26 Jun 2024
Amount
Labour only for taking down and lifting up high mast light fitting including replacing the unserviceable items to make the fitting serviceable ,serving, greasing of steel reopened adjust/repair the timer, supply and fixing in replacement the contacts lifting mechanism with all accessories as required, complete all as directed by the Engineer-in-Charge. (Note :- Spares like chokes, ignitor lamp & LED fitting will be measured and paid separately)
Dismantling and taking down the existing defective street light/security light/Post top Lantern fitting of any type and any capacity fixed at any height Complete all as directed by Engr-in-Charge.
Supply,fixing, connecting, testing and commissioning LED Street light fitting 90 Watt, 240 watt, 0.42 Amps, PF> 0.95, colour Temp 5700K new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 road luminaire with high power LEDs as light source and electronic driver.
Supply,fixing, connecting, testing and commissioning LED street light fittings 70 Watt ,240 VOLT, current 0.31 Amps, 5700 Temp, new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 road luminaire with high power LEDs as light source and electronic driver.
Supply,fixing, connecting, testing and commissioning LED flood light fittings 120 watt ,240 volt, 0.57 Amp current, > 0.95 PF, 5700 K Temp ,new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 road luminaire with high power LEDs as light source and electronic driver.
S&F Post top energy saving , environmental friendly, aesthetically designed with indirect symmetrical light distribution die-cast aluminium IP-65 luminaire with high power COB LED as light source of capacity 40/35 Watt, 6500K all as specified and directed.
S&F Post top energy saving , environmental friendly, aesthetically designed with indirect symmetrical light distribution die-cast aluminium IP-65 luminaire with high power COB LED as light source of capacity 20 Watt, 6500K incl dismantling and taking down unsv fitting any type all as specified and directed.
Note for item 3 to 7 : (i) A certificate of Gurrantee shall be submitted by the contractor for period 3 (three) years from the certified date of completion of work as a whole for repair/replacement of lamp & light fittings to GE. Performance guarantee amount @ 5% of quoted amount of LED lamps & light fitting shall be kept reserved for a period of three years. Atlernatively after completion of work contractror may furnished guarantee amount in the shape of FDR/BGB pleased in favour of GE. (ii) Luminarie shall be provided with all parameters mentioned above.
Supply and install 10 W bollard decorative luminaire IP 65 rated inverted Pyramid type LED bollard with soft 360 deg light distribution including fixing arrangement installaed in PCC foundation and taking down old unserviceavle all as specified and directed.
Supply and fix water proof electric distribution box( 3 Phase, 4 Wire), wheather proof IP-65 protection suitable for outdoor use, pole mounted, factory made of size 300mm x 250mm x 150mm comprising one No. MCB SP 6 Amps, 240 volts SPN bus bar not less than 25mm x 5mm aluminium strip and fixing clamps of size 25mm x 3mm two nos including necessary nuts, bolts and locking arrangement with lock, pressure type, four Nos connection holes in each bus bar with nuts, bolts and washers made of galvanized iron and connection thimble etc. complete all as specified and directed.
Supply and fixing Street light fitting electronic constant current drivers/PCB/electronic gear suitable for 40 to 60 Watt LED flood light/street light fitting as required at site or as per sample incl taking out old unserviceable all as specified and directed .
Supply and fixing Street light fitting electronic constant current drivers/PCB/electronic gear suitable for 70 to 90 Watt LED flood light/street light fitting as required at site or as per sample incl taking out old unserviceable all as specified and directed .
Supply and fixing Street / flood light fitting electronic constant current drivers/PCB/electronic gear suitable for 120 to 150 Watt LED flood light/street light fitting as required at site or as per sample incl taking out old unserviceable all as specified and directed .
GI bracket 1.5 mtr long made out of 40mm bore light grade, GI pipe, bend to shape as required complete with two Nos MS clamps fabricated out of MS flat of size 40 x 5 mm, nuts and bolts duly painted with two coats of aluminium paint of superior quality over a coat of red oxide primer, to be fixed on pole/on roof of building including taking down old brackets complete all as specified and directed by the Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in deep getting out in hard/dense soil for stay assembly/laying of cable/errection of poles etc complete all as specified and directed.
Excavation in trenches n exceeding 1.5m wide and exceeding 1.5 m deep and getting out in Soft/loose soil including forming bottom surface to requirted level for laying pipes complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
M & L for well burnt brick sub class B old size laying in trenches perpendicular to axis of the cable complete all as specified and directed.
Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 40 mm bore for protection of cable including dismantling existing pipe complete all as specified and directed by the Engineer-in-Charge.
Taking down old unserviceable 40mm dia light grade pipe
Taking out existing worn out/old PVC insulated cable in 4/2 core of 50 sqmm to 6 Sqmm size of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES compitent staff complete in all respect and as directed at site.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wal or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 35 Sqmm 3.5 core with required aluminium cable lugs all as specified and directed.
-- do-- as per item no. 23 above but size 50 sq mm 3.5 core
-- do-- as per item no. 23 above but size 25 sq mm 4 core
-- do-- as per item no. 23 above but size 16 sq mm 4 core
-- do-- as per item no. 23 above but size 6 sq mm 2 core
-- do-- as per item no. 23 above but size 10 sq mm 2 core
Supply and laying or fixing or passing through pipe from junction box to street light connection, 1100 volts grade heavy duty cable with PVC solid insulated aluminium conductor served with an inner sheathing PVC tape and over all PVC sheathed 10 Sqmm 2 core (TC) nominal cross section.
Supply and laying or fixing or passing through pipe from junction box to street light connection, 1100 volts grade heavy duty cable with PVC solid insulated aluminium conductor served with an inner sheathing PVC tape and over all PVC sheathed 6 Sqmm 2 core (TC) nominal cross section.
Dimentling and taking down old/unsv cross arms, bracing, supports etc complete all as specified and directed.
S&F cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complte all as specified and directed.
Dismantling old Unsv copping, foundation etc from pole, busbar,panel complete all as specified and directed.
PCC (1:4:8) type D-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed.
PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed.
PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and directed
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
S&F sheet metal enclosure box made out of 3.15 mm thick CRCA sheet with powder coated paint (CPRI approved) double door outdoor type including solid aluminium bus bar of capacity 100 Amp 4 Nos strip with locking arrangements, enclosure box to be fixed on plinth foundation 1:2:4 and 150 mm above ground level including MS angle/ channel consisting of necessary fixing arrangements for incoming & out going cables with cable glands, lugs, nut, bolts, washers and fixing arrangement , PCC work including necessary flat iron clamps with nuts, bolts & washers and Powder coated all as specified and directed.
S&F MCCB 100 Amps 4 Pole, 16 KA, 415 V, 50 Hz adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
S&F MCCB 160 Amps 4 Pole, 25 KA, 415 V, 50 Hz adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
M &L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried in ground vertically to a depth not less than 2.25 mm below ground level with top edge of the earth plate not less than 1.5 mm below normal ground level, connected to GI strip 32 x 6 mm continuity conductor including 15 mm bore pipe light grade for protection of strip by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel connected to earth test point upto 7.5 mt away from earth electrode all as shown as per plate No 03 of SSR I including necessary earth work, PCC 1:3:6 type C 1 chamber, RCC cover slab of 50 mm thick 1::2:4 with 8 mm CTD 140 mm C/C with suitable handle,watering pipe 20 mm dia light grade pipe with funnel,. charcoal salt and testing on completion and including taking old unserviceable earthing with connected items all as specified and directed by Engr in charge including taking down old/unsv earthing.
S & F in replacement air termination single pointed aluminium rod 12 mm dia and 300 mm long fitted on exisiting lightening conductor tube 40 mm on buildings with F clamps nut bolts complete all as specified and directed.
S & F in replacement earth test point terminal block made out of gun metal or phorphorus bronze size 75 x 75 x 5 mm , drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw grouting on wall with PCC, nut bolts and washers, including making good to disturbed surface complete all as specified and directed.
S&F Galvanised iron strip 32 x 6 mm for extension of earth and connected to equipment or panel complete all as specified and as directed .
S & F aluminium strip 25 x 3.15 mm with saddle and fixing screws, gutties etc on wall and roof top conductors including grouting wooden gutties complete all as specified and directed.
Refixing GI tubing light grade 40 mm bore obtained from above item no 49 including grouting in PCC complete all as specified and directed for fixing leghtening arrester on roof top.
Taking out old handing GI strip/Aluminium (damaged by Monkey ) from roof and wall complete excluding straightening the strip and refixing in the same position with saddle fixing screws gutties etc on wall and roof op conductors including grouting wooden gutties complete all as specified and directed.
S & F GI tubing light grade 40 mm bore fixing in bricks/stone wall with 2 Nos sopporting clamp made of flat iron of size 25 x 4 mm including nut bolt and grouting bolt complete all as specified and directed for fixing lightening arrester on roof top.
S&F GI tubing light grade 40 mm bore fixing including grouting in PCC complete all as specified and directed for fixing lightening arrester on roof top.
M&L for testing of earthing (in Half Yearly Ending Dec-2023 and June 2024 ) inside/outside depot area ( 1 ASD, 2ASD, ATA, E/M Installation, Quarter Guard) duly filling the respective register of earthing provided by JE E/M office Note- necessary tools and plants and earth tester to be provided by Contractor in deemed quoted rate.
M&L for constructing Earth pit of internal size not less than 300x300x150mm PCC 1:3:6 type C 1 chamber, RCC cover slab of 50 mm thick 1:2:4 with suitable handle.Dismantling old unsv one.
M&L for preparing scraping the old painted surfaces of GI Pipe light grade 40 mm fixed on wall/roof for lightening conductor and applying two coat of aluminium paint on GI Pipe light grade 40 mm approx 3 mtr long and bracket, clamp complete and all as specified and directed.
M&L for removing old paint from the LT panels/feeder box/pole by paint removers, cleaning by scrapping and preparing the surface and applying two coats Painting complete to LT panels/feeder box with synthetic enameled paint of existing colour over a coat of red oxide primer and writing work as written of existing ie feeder feeding location etc complete all as directed by Engr-in-Charge.
Supply and errect steel tubular swaged poles complete with MS base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (09 metres long) conforming to IS 2713 including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer over the exposed surface and applying two coats of black bituminous paint over the embeded portion of pole, errecting in truly vertical position complete all as specified and directed.
Supply and errect steel tubular swaged poles complete with MS base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metres long) conforming to IS 2713 including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer over the exposed surface and applying two coats of black bituminous paint over the embeded portion of pole, errecting in truly vertical position complete all as specified and directed.
Supply and fixing of guard rails wire netting of galvanized steel wire 1.40mm dia with 25x25mm mesh size fixed with tinned tracks of wire staples duty painted with two coat of synthetic enamel aluminium/smoke grey paint over a coat primer complete for transformer platform all as specified and directed.
S&F Angle iron guard rail of 600mm height welded with M.S Angle iron 60x60x6mm, MS flat 50x6mm for interlocking arrangements all as specified and directed.
Dismantling concrete/steel poles/struts, any size all as specified and directed.
Material and labour for Brick Work with sub class B Bricks Straight or Curved or plan to any radius in half brick thick wall built in cement mortar (1:4) for construction and repair of transformer platform.
Dismantling the old brick work complete
Material and labour for plastering on fair faces of Brick Work with 10mm thick cement plaster (1:4)
Material and labour for Distempering 2 Coats on walls with distemper dry, white or tinted plastering on fair faces of Plaster
Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 150 mm bore for protection of cable including dismantling existing pipe complete all as specified and directed by the Engineer-in-Charge.
M&L for removing old paint from chain link fencing , steel section post by paint removers, cleaning by scrapping and preparing the surface and applying two coats Painting complete with synthetic enameled paint of existing colour over a coat of red oxide primer complete all as directed by Engr-in-Charge.
Supply and fixing in replacement of Automatic Light Timer switch with Nature switch Cat No. SWADEEP-02EC12KW3P, infra ray sensor with pre sawn switching off timer, 4-8 hrs, of Maximum load capacity of 4KW per phase. Degree of protection conforms to IP 65 complete all as specified and directed.
Supply and making in replacement new LT 1100 V end termination with suitable size of aluminium lugs duly crimped for LT 3 ½ core armoured aluminium conductor cable after isolating supply to transformer/LT panel and disconnecting brunt/fault cable from the bunch of cables in trenches,alleries, removing cable loop, opening the cable blank and connecting back after end terminals, testing and commissioning for following sizes all as specified and as directed Note Excavation,Removal, Return filling in to be paid in deemed quoted rate.
95 Sqmm to 120 Sqmm
35 Sqmm to 70 Sqmm
6 Sqmm to 25 Sqmm
Surface dressing not exceeding 15 cm deep and getting out in soil including cleaning away all grass vegetation saplings, bush under grouting, roots etc and removing rubbish to a distance of 50 M outside the periphery of area complete all as specified and as directed. Location- Transformers, LT Panels, 2/3/4 Pole structures/LT street light Poles etc.
Deduct Schedule of Credit of Rs. (-) 103020.00 (Minus) as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount Note: Tenderers will not quote against this item being a firm amount.
M/S DHARAM & SONS ENTERPRISES
DAVINDER SINGH
K S BUILDERS
PROACH ASSOCIATES BUILDERS & ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .