Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹36.4 L+₹7.6 L (26.4%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | Rejected-Technical | - | Rejected-Technical Incomplete Document |
| Sl No | Description | Qty | Unit | M/S RAGHAV and BROTHERS L1 | shree sai enterprises L2 |
|---|---|---|---|---|---|
| 1.00Carriage of following material from store center PVVNL to site & vice-versa of work including loading & unloading at both ends maximum distance up to 100 Km. :- | |||||
| 1.01 | ST/PCC Pole 11 mtr long | 6 | Nos | 1,500 ₹9,000 | 500 ₹3,000 Lowest |
| 1.02 | PCC Pole 8.5 mtr long | 69 | Nos | 500 ₹34,500 Lowest | 500 ₹34,500 Lowest |
| 1.03 | ACSR Weasal Conductor | 1,878 | Mtr | 5 ₹9,390 | 4 ₹7,512 Lowest |
| 1.04 | 11 KV Pin Insulator with nut and bolt | 186 | Nos | 10 ₹1,860 | 5 ₹930 Lowest |
| 1.05 | 11 KV Disc Insulator with nut and bolt | 108 | Nos | 10 ₹1,080 Lowest | 10 ₹1,080 Lowest |
| 1.06 | LT AB Cable 3x120 sq.mm | 3,365 | Mtr | 10 ₹33,650 Lowest | 12 ₹40,380 |
| 1.07 | LT AB Cable 3x95 sq.mm | 4,405 | Mtr | 10 ₹44,050 Lowest | 10 ₹44,050 Lowest |
| 1.08 | 400 KVA T/F 11/0.4V | 7 | Nos | 3,500 ₹24,500 Lowest | 3,500 ₹24,500 Lowest |
| 1.09 | 250 KVA T/F 11/0.4V | 6 | Nos | 3,000 ₹18,000 Lowest | 3,500 ₹21,000 |
Tender Value
₹31 L
EMD Value
₹31,000
Closing Date
12 Sept 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER
SE, EDC-1, Meerut
ETN0-32/EDC-1/MT/2025-26
2025_PVVNL_1069324_1
ETNo.32/EDC-1/MT/2025-2026
Open Tender
Electrical Works
Lump-sum
180 days
Under EDD-KITHORE
ETN0-32/EDC-1/MT/2025-26
2 documents required · 2 mandatory
₹3,540
SUPERINTENDING ENGINEER
₹31,000
25 Sept 2025
28 Aug 2025
12 Sept 2025
28 Aug 2025
12 Sept 2025
28 Aug 2025
Amount
Carriage of following material from store center PVVNL to site & vice-versa of work including loading & unloading at both ends maximum distance up to 100 Km. :-
ST/PCC Pole 11 mtr long
PCC Pole 8.5 mtr long
ACSR Weasal Conductor
11 KV Pin Insulator with nut and bolt
11 KV Disc Insulator with nut and bolt
LT AB Cable 3x120 sq.mm
LT AB Cable 3x95 sq.mm
400 KVA T/F 11/0.4V
250 KVA T/F 11/0.4V
100 KVA T/F 11/0.4V
25 KVA T/F 11/0.4V
11 KV Fuse set
Stay set
11 KV XLPE Cable 3x120 sq mm
LT XLPE Cable 1x240 sq mm
Al Cable 400 sq mm 1 Core
LT XLPE Cable 3.5x70sq mm
Errection ST/PCC Pole 11 mtr long/PCC pole 8.5 mtr long after digging a pit of size 1.6 mtr deep in all type of Soil including grouting ratio (1:4:8) of the pole with proper ramming after completion of work. (as per UPPCL Respo).
Laying, lifting of LT AB Cable 3x95 (As Per Direction of Supervising Engineer).
Laying, lifting of LT AB Cable 3x120 (As Per Direction of Supervising Engineer).
Laying of ACSR Weasal Conductor for jumpering. (As Per Direction of Supervising Engineer).
providing and Fixing of Stay rod complete as per norms. (As Per Direction of Supervising Engineer).
Providing and Fixing of MS Nut and Bolts. (as per UPPCL Respo).
Providing and Fixing Clamp with nut and bolt (as per UPPCL Respo).
Providing and Fixing 2" dia GI Pipe upto 80 feet Water level earthing 250/400 KVA T/F (Neutral and Body) (as per UPPCL Respo).
Making of New 250/400 KVA T/F Plinth of size 6'x6'x3' (feet) (as per UPPCL Respo).
New Wiremesh Fencing of 250/400 KVA T/F. (as per UPPCL Respo).
Providing and Fixing of Dropper Channel. (as per UPPCL Respo).
Fixing of 11 KV Fuse Set. (As Per Direction of Supervising Engineer).
Providing and Fixing of Top channel. (as per UPPCL Respo).
Providing and Fixing of T-off channel. (as per UPPCL Respo).
Providing and Fixing of Piercing Clamp. (as per UPPCL Respo).
Providing and Fixing of Suspension Clamp. (as per UPPCL Respo).
Providing and Fixing of Dead and Clamp (as per UPPCL Respo).
Providing and fixing of Stone Pad (as per UPPCL Respo).
Providing and fixing of Tailless Unit (as per UPPCL Respo).
Providing and fixing of Danger Board (as per UPPCL Respo).
Providing and fixing of LT Fuse Set (As Per Direction of Supervising Engineer).
Providing and fixing of J- Hook (as per UPPCL Respo).
Providing and fixing of Jointing Kit 3x120 sq mm (as per UPPCL Respo).
fixing of 11 KV XLPE Cable 3x120 sq mm with trench (As Per Direction of Supervising Engineer).
Providing and fixing of Lug 400 sq mm (as per UPPCL Respo).
Providing and fixing Distribution Box 3 Phase (as per UPPCL Respo).
fixing LT XLPE Cable 1x240 sq mm (As Per Direction of Supervising Engineer).
Providing and fixing 11 KV TPMO (as per UPPCL Respo).
fixing Al Cable 400 sq mm 1 Core (As Per Direction of Supervising Engineer).
fixing LT XLPE Cable 3.5x70sq mm (As Per Direction of Supervising Engineer).
shree sai enterprises (BID ID -5529796)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .