Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC SHIVAJI NAGAR GALI NO 1 DHANGU ROAD MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹24.8 L Quoted ₹24.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹25.2 LRejected-Finance | ₹25.2 L | L2 | Rejected-Finance L2 |
| 3 | L3₹27.6 LRejected-Finance | ₹27.6 L | L3 | Rejected-Finance L3 |
| 4 | L4₹28.7 LRejected-Finance | ₹28.7 L | L4 | Rejected-Finance L4 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Tender fee i.e DD uploaded not in favour of GE (South) Pathankot and Not enlisted in requisite category |
| Sl No | Description | Qty | Unit | KEWAL SONS L1 | Abrol construction co L4 | Micky Traders L3 | M/S GOLDEN CONSTRUCIONS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing and commissioning of High Temperature Air Cooled Refrigeration System (Walk in Cooler) 5.5 TR Capacity and Cooling Capacity 5.5 Ton/66000 BTU/hr and having Room temperature between 0 Degree Celcius to 10 Degree Celcius with hermetically sealed scroll/ reciprocating type compressor 5.5 HP to 6.5 HP depends upon models and power supply 3 Phase , 415 Volts , 50 Hz , ceiling or wall mounted type and Evaporator forced air type and Air cooled condenser having suitable qty of Eco friendly Refrigerant Gas R-404A/R-134a/R-407C etc and having Compressor/ Condensing unit Out door type, Evaporator coil indoor unit, copper refrigeration piping , Digital temperature controller, Expansion valve and drier filter , control panel with MCBs and over load relays, door heaters for anti condensation , temperature recorder motion sensor lights , remote monitoring system , alarm system for temperature breach and electrical safety as per IEC/IS standards. Stainless steel body indoor unit, corrosion resistance, inner grooved copper tubes, uniform air throw for uniform air distribution, low noise level and confirm IP45 standards, Removable side panel, Outdoor units have energy efficient scroll/ reciprocating compressors, Powder coated body, filter drier for moisture and dust protection, Pre - Charged unit with suitable refrigerant Gas with service valves, safety control device ,weather proof polyester powder coated canopy thermal protection and permanently lubricated fan moters with controller including power panel, electrical connection with necessary accessories and wiring connection panel to indoor and outdoor unit etc complete and Dismantling/ Removing the existing old UNSV walk in cooler/ refrigeration system and deposite to MES Store yard complete all a specified and directed by Engr-in-charge with the following specification :- | 5 | Each | 4,30,000 ₹21.5 L | 4,90,000 ₹24.5 L | 4,50,000 ₹22.5 L | 4,20,000 ₹21 L |
| 1.01 | INDOOR UNIT :-,
1. Nominal Cooling Capacity - 5.5 Ton/ 66000 Btu/hr
2. Power Supply - 415 Volt
3 Phase - Three (03)
4. Frequency - 50 Hz
5. No of Circuit - as per site requirement
6. Air Flow - Between 2000 to 2500 CFM
OUTDOOR UNIT :-
8. Compressor Type - Hermetically sealed Scrool/reciprocating type
9. Power Supply - Three Phase 415 Volt
10. Frequency - 50 Hz | - | - | - | - | - | - |
| 2.00 | Supply and Fixing of 100 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 16 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board including taking down old unsv MCCB complete all as specified and directed. | 3 | Each | 4,500 ₹13,500 | 6,000 ₹18,000 | 6,100 ₹18,300 | 4,100 ₹12,300 |
| 3.00 | Supply and Fixing of 63 AMP MCCB, 3 pole 415 volt, AC 50 Hz, 16 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board including taking down old unsv MCCB complete all as specified and directed. | 2 | Each | 4,500 ₹9,000 | 6,000 ₹12,000 | 6,100 ₹12,200 | 4,100 ₹8,200 |
| 4.00 | M&L for laying cable in replacement XLPE insulated armoured heavy duty electric cable with aluminum conductor, 1100 volts grade of cross sectional area 50 Sq mm 3.5 core complete all as specified and directed.
Note: Earth work (Excavation, Returning & refilling and removal), sand cushioning , cable protection cover, GI protection pipe shall be measured and paid for separately under respective item of Schedule | 270 | RM | 390 ₹1.1 L | 500 ₹1.4 L | 490 ₹1.3 L | 550 ₹1.5 L |
| 5.00 | Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out in any type of soil all as required for laying of cables, Foundation, filling of poles or stays complete all as specified and directed by Engineer-in-Charge. | 62 | Cum | 90 ₹5,580 | 100 ₹6,200 | 80 ₹4,960 | 100 ₹6,200 |
| 6.00 | Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. | 21 | Cum | 60 ₹1,260 | 80 ₹1,680 | 88 ₹1,848 | 20 ₹420 |
| 7.00 | Returning, filling in, including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required complete all as specified and directed by Engineer-in-Charge. | 41 | Cum | 60 ₹2,460 | 90 ₹3,690 | 82 ₹3,362 | 20 ₹820 |
| 8.00 | M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified and directed.
Note: Punned thickness of sand shall be measured. | 18 | Cum | 500 ₹9,000 | 100 ₹1,800 | 80 ₹1,440 | 500 ₹9,000 |
| 9.00 | Supply and laying sub class 'B' bricks of (230x115x75 mm) or of size locally available, aid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge | 1,990 | Each | 6 ₹11,940 | 10 ₹19,900 | 20 ₹39,800 | 9 ₹17,910 |
Tender Value
₹27.6 L
EMD Value
₹55,300
Closing Date
24 Dec 2025, 6:00 pmClosed
GE SOUTH PATHANKOT
GE SOUTH PATHANKOT
GES/PKT/70/2025-26 REPLACEMENT OF EXISTING OLD VINTAGE WALK-IN-COOLER WITH CONNECTED ACCESSORIES IN BLDG NO. NP-126 AT FMSD, QM AND MEDICAL STORE AT MH INCLUDING PROVN OF 50 WALL MOUNTED FANS FOR VARIOUS WARDS AND DEPTS AT MH UNDER GE SOUTH PATHANKOT
2025_MES_742267_1
GES/PKT/70/2025-26
Open Tender
Electrical and Maintenance Works
180 days
PATHANKOT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE SOUTH PATHANKOT
₹55,300
Yes
11 Feb 2026
1 Dec 2025
26 Dec 2025
1 Dec 2025
24 Dec 2025
16 Dec 2025
Amount
Supply, Installation, Testing and commissioning of High Temperature Air Cooled Refrigeration System (Walk in Cooler) 5.5 TR Capacity and Cooling Capacity 5.5 Ton/66000 BTU/hr and having Room temperature between 0 Degree Celcius to 10 Degree Celcius with hermetically sealed scroll/ reciprocating type compressor 5.5 HP to 6.5 HP depends upon models and power supply 3 Phase , 415 Volts , 50 Hz , ceiling or wall mounted type and Evaporator forced air type and Air cooled condenser having suitable qty of Eco friendly Refrigerant Gas R-404A/R-134a/R-407C etc and having Compressor/ Condensing unit Out door type, Evaporator coil indoor unit, copper refrigeration piping , Digital temperature controller, Expansion valve and drier filter , control panel with MCBs and over load relays, door heaters for anti condensation , temperature recorder motion sensor lights , remote monitoring system , alarm system for temperature breach and electrical safety as per IEC/IS standards. Stainless steel body indoor unit, corrosion resistance, inner grooved copper tubes, uniform air throw for uniform air distribution, low noise level and confirm IP45 standards, Removable side panel, Outdoor units have energy efficient scroll/ reciprocating compressors, Powder coated body, filter drier for moisture and dust protection, Pre - Charged unit with suitable refrigerant Gas with service valves, safety control device ,weather proof polyester powder coated canopy thermal protection and permanently lubricated fan moters with controller including power panel, electrical connection with necessary accessories and wiring connection panel to indoor and outdoor unit etc complete and Dismantling/ Removing the existing old UNSV walk in cooler/ refrigeration system and deposite to MES Store yard complete all a specified and directed by Engr-in-charge with the following specification :-
INDOOR UNIT :-, 1. Nominal Cooling Capacity - 5.5 Ton/ 66000 Btu/hr 2. Power Supply - 415 Volt 3 Phase - Three (03) 4. Frequency - 50 Hz 5. No of Circuit - as per site requirement 6. Air Flow - Between 2000 to 2500 CFM OUTDOOR UNIT :- 8. Compressor Type - Hermetically sealed Scrool/reciprocating type 9. Power Supply - Three Phase 415 Volt 10. Frequency - 50 Hz
Supply and Fixing of 100 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 16 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board including taking down old unsv MCCB complete all as specified and directed.
Supply and Fixing of 63 AMP MCCB, 3 pole 415 volt, AC 50 Hz, 16 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board including taking down old unsv MCCB complete all as specified and directed.
M&L for laying cable in replacement XLPE insulated armoured heavy duty electric cable with aluminum conductor, 1100 volts grade of cross sectional area 50 Sq mm 3.5 core complete all as specified and directed. Note: Earth work (Excavation, Returning & refilling and removal), sand cushioning , cable protection cover, GI protection pipe shall be measured and paid for separately under respective item of Schedule
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out in any type of soil all as required for laying of cables, Foundation, filling of poles or stays complete all as specified and directed by Engineer-in-Charge.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required complete all as specified and directed by Engineer-in-Charge.
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified and directed. Note: Punned thickness of sand shall be measured.
Supply and laying sub class 'B' bricks of (230x115x75 mm) or of size locally available, aid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
S&F of 400 mm (16 Inch) Wall Mounted Fan with 03/05 Nos ABS or Aluminium blades white in colour and power consumption 45-80 watt , operating voltage 165-285 V AC 50 Hz and air delivery not less than 65-85 m3/min, fan speed , 1300-1500 RPM, and 90' automatic oscillation system (motorized) along with pull cord or rotary switch with 03/05 speed settings and copper wounded shaded pole/induction motor with suitable wall brackets , screws and plugs for mounting of fan on wall including making good disturbed surfaces during the work complete all as specified and as directed.
M&L for point wiring with FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm in FRLS PVC concealed conduit heavy duty and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc.) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting for the following all as specified and directed. Note:- In ceiling Portion surface conduit wiring shall be carried out.
One wall fan point controlled by one switch SP, one way, 5 Amp, 240 Volts
One 3 pin 5A socket outlet independent board.
M&L for switch with switch piano polycarbonate body type single pole one way 5/6 Amp, 230 volts, complete all as specified and directed.
M&L for socket outlet with socket outlet Polycarbonate body , 5 pin 5 Amp, 230 volts flush type complete all as specified and directed.
Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account. (ii) The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum.
M/S GOLDEN CONSTRUCIONS (BID ID -3507127)
Micky Traders (BID ID -3507168)
Abrol construction co (BID ID -3507015)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_831185.xls
BOQ • 0.83 MB
tender70.pdf
Tender Documents • 1.28 MB
Download all tender documents and submit your bid