Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.2 LAccepted-AOC 123 23 1 SHRISANT APARTMENT MANGALMURTI NAGAR PASHAN SUTARWADI ROAD PASHAN PUNE MAHARASHTRA 411021 | PUNE | MAHARASHTRA | 411021 | L1 | Accepted-AOC Awarded lowest bidder (L1) | |
| 2 | L2₹46.1 L+₹4.8 L (11.6%)Rejected-AOC PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L2 | Rejected-AOC Being second lowest (L2) | |
| 3 | Rejected-Technical NEAR SWAMI SAMARTH MANDIR GROUND FLOOR 28 1 1 D SHIVRAJ NAGAR SAI MIRACLE ROAD RAHATNI PUNE 411 017 | PUNE | MAHARASHTRA | 411017 | - | Rejected-Technical Not enlisted in required category | |
| 4 | Rejected-Technical GALA NO B 128 129 130 SATYAM INDUSTRIAL ESTATE OFF KARVE ROAD OPP SNDT COLLEGE ERANNDWANE PUNE 411038 PUNE MAHARASHTRA 411038 | PUNE | MAHARASHTRA | 411038 | - | Rejected-Technical Not enlisted in required category | |
| 5 | Rejected-Technical 5 KEDAR APARTMENTS 484 60 PARVATI MITRAMANDAL COLONY PARATI PUNE 411 009 | PUNE | PUNE | MAHARASHTRA | 411009 | - | Rejected-Technical Not enlisted in required category |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
28 Dec 2019, 6:00 pmClosed
GERD PASHAN PUNE
GERD PASHAN PUNE
Repair Maintenance of fire fighting system including fire deglue system inside technical area under GE I RD Pashan Pune
2019_MES_299615_2
GERD/PSN/TOKEN/38 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
GERD PASHAN PUNE
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GERD PASHAN PUNE
₹84,000
Yes
17 Feb 2020
14 Dec 2019
1 Jan 2020
15 Dec 2019
28 Dec 2019
23 Dec 2019
15 Dec 2019 - 21 Dec 2019
Amount
Material and labour for Comprehensive maintenance consisting of normal repairs,Periodical and preventive maintenance operational and performance testing and attending day-to-day break down of 2 zone/4zone /8 zone deluge fire system locted in processes building of SRP/HE/GP/ED/ECP complex/Inhibition bldg at inside process building in side HEMRL complex/techanical area for following complete all as specified and directed Note (i) Checking of all control wiring in fire alarm panel including checking fire alaram panel / data card/sensors / contactors /relays complete for loose connection, leakage of current, battery backup system including tightening of glands (ii) checking of all butterfly/sluice/deluge valve/srainers including deluge pipelines at required working pressure complete including repair of system to avoid leakage (iii) Checking of IR detector/UV detectors /zero velocity spray nozzles/manual call points/ Hooters/dynamically balanced siren/ sensor /solenoid valve (a)2 zone fire deluge system - 4 Nos
(b) 4 zone Fire Deluge system -12 Nos
(c) 8 Zone Fire deluge system-09 Nos
Supply,fix,test and commissioning of with weather shed type manual call points in repair, manual call point resettable type wall mounting type with and including dust and moisture proof cover and designed to rise the alarm once the glass is broken complete all as specified and directed Make:-Newage industries/Minimax/Safex/Ravel/Agni
Supply,fix,test commissioning in repair Fire Alarm hooter electronic type with and including weather shed complete all as specified and directed. Make:-Naveen or equivelant ISI marked as approved by GE
Supply,fix,test and commissioning in repair high velocity water spray nozzles having end connection of 10.05 mm BSPT,spray angle of 90 degree brass finish,UL listed suitable for deluge system for fire protection application suitable for max pressure 12.3 kg/sqcm complete all as specified and directed.
Supply,fix test and commissioning in repair dynamically balanced siren Fire Alarm Sounders / Sirens electronic type horizontal single stage continous normal operation 24 V/6000 RPM,1000 mtrs radius range for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 meter with sound output variation of +5 DB complete with provision of GI mounting arrangements complete all as specified and directed. Make:-Kheraj electrical(I) Pvt Ltd. or equivelant ISI marked as approval By GE
Material and labour in repair for rechargeable SMF batteries of BP-46,for 20Hours backup for microprocessor based intelligent control panel and DG set complete including comprising the followings, complete all as specified and directed of following capacities:- i) The cells shall be sealed in type with and including anti-splash type vent plug. ii) The cell terminal posts shall be provided with and including connector bolts and nuts, effectively coated with lead to prevent corrosion. Lead or lead coated copper connectors shall be furnished to connect up cells of battery set. iii) Positive and Negative terminal posts shall be clearly and indelibly marked for easy identification. iv) The electrolyte shall be of battery grade Sulphuric Acid conforming to IS: 226-2962. Water for storage batteries conforming to IS: 1069 shall be used in the preparation of the electrolyte. Make:-Exide/Tata/Standerd Farukha (a). 12 Volts,40 AH
(b). 12 Volts,28 AH
(c). 12 Volts,7 AH
(d). 12 Volts, 180 AH
Material and labour in repair for flame / weather proof continuous monitoring detector UV sensors simultaneously detect the presence of flame, an alarm signals complying with type certified to EN-45 addressable type smoke/flame detection of suitable capacity working on DC 24 volts and angle of detection not less than 90 degree generated including fame sensing and high degree of discrimination against gamma rays, X ray and arc weldings complete all as specified and directed for the following type Make : Hochaki / Honey well/Applo/Simens/Ntifire (a) Ultraviolet (UV) detctor working on 24 volts DC with operating range 18 to 24 volts and maximum power consumption 2.8 watts with and including inbuilt three type of relays for fire alarm, fault and auxillary 5 amps rated.
(b) Infrared (IR) detctor working on 24 volts DC with operating range 1.45 to 2.9 volts and s with and including inbuilt three type of relays for fire alarm, fault and auxillary 5 amps rated and radiation centred not less than 4.4 microns.
Supply,fix,testing and commissioning in repair for medium velocity water spary nozzles having end connections of 15 mm BSPT,spray angle of 65 digree brass finish,UL listed suitable for deluge system for fire protection application suitable for maximum working pressure 12.3 Kg/sqcm complete all as specified and directed. Make:-HD fire protect Pvt ltd,Model-A or equivelant
Supply and fix,test and commissioning in repair for microprocessor based intelligent control panel two zone to control deluge system including battery backup 20 hours with and including provision of battery charger 2 Nos rechargeable SMF batteries of BP 46,12 volts,40 AH/20 HR in each building complete including glands lugs and indication on cable control wiring for two zone complete all as specified and directed. Make:- Ravel electronics/Tricks fire control/ Notifier/Minimax/ Wizmart/ Seimens/Cerbrus
all as per item no.15 here-in before but for four zone
all as per item no.15 here-in before but for eight zone
Supply,fix,test and commissioning in repair Cast iron fabricated "Y" type stainer complete with and including nut,bolts,washer and rubber gasket complete all as specified and directed of following sizes:- (a). 50 mm bore
(b).80 mm bore
Supply,fix,test and commissioning in repair Cast iron fabricated electricaly /hydraulically operated type deluge valve complete with and including nut,bolts,washer and rubber gasket complete all as specified and directed by Engineer-in-charge of following sizes:- (a) 80 mm bore
All as per item No 20 here-in before but for 50 mm bore
Supply,fix,test and commissioning in repair TRIM ASSEMBLY of cast iron fabricated electricaly /hydraulically operated deluge valve complete with and including solenoid valve pressure switch to activate an electric alarm, to shut down the desired equipment or to give “Tripped” indication to the panel complete with and including nut,bolts,washer and rubber gasket complete all as specified and directed by Engineer-in-charge of following sizes:- (a) 50 mm bore
All as per item No 22 here-in before but for 80 mm bore
Material and labour in repair for 2 way Solenoid valve 15mm size with and including 24VDC/110 VAC/220 VAC for remote activation suitable to withstand 10bar hydraulic pressure complete including complete wiring necessary for smooth funtioning of complete deluge system complete all as specified and directed
Material and labour in repair for Coil of solenoid valve 24VDC/110 VAC/220 VAC remote activation suitable to withstand 10bar hydraulic pressure complete including complete wiring necessary for smooth functioning of complete deluge system complete all as specified and directed
Supply,laying,testing and commissioning in repair on wall,roof or floor,armoured FRLS cables from detector to panel,panel to hooters,manual call points,deluges valves etc.of size 2 core1.5 sqmm PVC insulated and sheathed complete all as specified and directed by engineer-in-charge.Make:-Universal/Finolex/CCI/Incab/Havells
Supply,laying,testing and commissioning in repair on wall,roof or floor,armoured FRLS cables from detector to panel,panel to hooters,manual call points,deluges valves etc.of size 2 core 2.5 sqmm PVC insulated and sheathed complete all as specified and directed by engineer-in-charge.Make:-Universal/Finolex/CCI/Incab/Havells
Supply and fix in repairs CI sluice valve of dia 80 mm bore,both end flanged conforming to IS 14846,ISI marked with stainless steel spindle including jointing with and including 3.o mm thick rubber gasket,nuts,bolts,washers etc class PN 1 with and including iron wheel head complete all as specified and directed by Engineer-in-charge.Make:-Kartar/Venus/Bir/Kirloskar/Upadhya
All as per item No.28 here-in before but 100 mm dia bore Make:-Kartar/Venus/Bir/Kirloskar/Upadhya
All as per item No.28 here-in before but 150 mm dia bore.Make:-Kartar/Venus/Bir/Kirloskar/Upadhya
Supply and fix in repairs CI Butterfly valve 50 mm dia bore wafer type , ISI marked with and including stainless steel disc including jointing with 3 mm thick rubber /nitrital gasket,nuts,bolts,washers etc class PN 1.0 with and including iron lever complete all as specified and directed by Engineer-in-charge. Make:-Kartar/Venus/Bir/Kirloskar/Upadhya
All as per item No 31 here-in before but for 80mm dia bore
All as per item No 31 here-in before but for 100mm dia bore
All as per item No 31 here-in before but for 150mm dia bore
Material and labour in repair for fire hydrant post 80mm dia both end flanged,1.5 metre long with one end bent to 90 degrees suitable for long single fire hydrent valves including painting with two coats of fire red colour synthetic enamel paint over one coat of zinc chrome primer including preparation complete all as specified and directed.
Material and labour in repair for fire hydrant valve assembly 65 mm dia with single flanged end pattern confirming to IS-5290 type"A" including neoprene gasket, nuts bolts washer complete all as specified and directed. Make:-Newage/Bir/Kartar/Kirloskar
Material and labour for repair of existing fire hydrant valve assembly 65 mm dia with single flanged end pattern complete including neoprene gasket, nuts, bolts, washers including replacement of following spares complete all as specified and directed Note -Spares required to be replaced shall be measured and paid as 'supply only' under relevant item here-in-after
Supply only CI operating Wheel all as specified and directed.
Supply only Stainless Steel Spindle all as specified and directed
Supply only Female coupling with and including Neoprene washers all as specified and directed
Material and labour for prepration of old steel surface and applying one coat of red post office synthetic enamel paint to the MES fire hose box of glass of size 30"x24"x10" including mild steel angles and name plate clearly indicating HYDRANT NO complete all as specified and directed by Engineer-in-charge.
All as per item No.41 here-in before but of size 36"x30"x10'' including mild steel angles and name plate clearly indicating HYDRANT NO complete all as specified and directed by Engineer-in-charge.
Material and labour for prepration of old steel surface and applying one coat of red post office synthetic enamel paint to pipes above ground level of different sizes of fire/deluge system complete all as specified and directed by Engineer-in-charge
Material and labour for painting of chain link fencing having mesh of size 50mmx50 mm/60mmx60 mm including stiffeners nuts bolts MS angle by applying one coat of red oxide primer and two coats of red post office synthetic enamel paint complete all as specified and directed by Engineer-in-charge.
Material and labour in repair for mild steel fire hose box made from mild steel sheet,glass in front,painted with 2 coats of fire red colour synthetic enamel paint, PCC foundation 3 mx 0. 3m x 0.3 m in PCC (1:2:4) type B1 using 20mm graded crushed stone aggregate duly supported with and including mild steel angle of size 40mmx40mmx5mm duly painted to accommodate two nos of 15 meter long 63 mm dia hose with and including quick jointing coupling made out of brass hose complete all as specified and directed by Engineer-in-charge of following sizes:- (a).Size 30''x24''x10''
Supply and fix in repair for gunmetal branch pipe 63 mm instantaneous inlet ,made threded outlet ,15 mm bore nozzle as per IS 903 complete all as specified and directed by Engineer-in-charge.
Material and labour for testing of the pressure of fire hydrants at least 03 Nos of fire hydrants,at the adjecent side of hydrants opened with test providing nipple made out of brass 20 mm outlet with all fittings pressure guage 0-14 Kg/Cm2 all as per IS-13039-1991 Para 7.5.
Material and labour for plain cement concrete 1:3:6 type C1 using 20 mm graded crushed stone aggregate for mass filling finished even and fair on exposed surfaces for route indicators complete all as specified and directed by Engineer-in-charge.
Supply and fix in repairs CI/DI fitting for spigot socketed pipes such as Bends (any type, radius an angle) Tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, `Y' junction, double branch, cross (all sockets or flanged ) collars, caps and plugs of size 200mm -300 mm bore complete all as specified and directed
Supply and fix in repair CI/DI fitting for spigot socketed pipes such as Bends (any type, radius an angle) Tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branc, `Y' junction, double branch, cross (all sockets or flanged ) collars, caps and plugs, Connecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth Upto150 mm bore complete all as specified and directed. Note for item No 49 & 50 :- Joint including jointing material shall be measured and paid for seperately.
Burning out leaking lead joints in position including removing of old lead for the following sizes complete all as specified and directed by Engineer-in-charge :- (a).80 mm dia bore of pipe
(b).100 mm dia bore of pipe
(c).150 mm dia bore of pipe
(d).200 mm dia bore of pipe
Material and labour for run lead joints for CI pipes/fittingscomplete with necessary jointing material such as pig lead and spun yarn,fire wood for jointing of pipes complete all as specified and directed by Engineer-in-charge for the following sizes:- (a).80 mm bore of pipe
(b).100 mm dia bore of pipe
(c).150 mm dia bore of pipe
(d).200 mm dia bore of pipe
Supply and fix in repairs unservicable water pressure gauge 4" dia with and including tube to match with the existing for range 0 to 14 kg/sq cm rating complete all as specified and directed
Supply and fix in repairs unservicable water pressure gauge 4" dia with and including tube to match with the existing for range 0 to 21 kg/sq cm rating complete all as specified and directed
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter deep for taking out/laying for GI/CI pipes and geeting out in:-(a) Soft/loose soil
As as per item No 61 above but for Hard / dense soil
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms in soft /loose soil complete all as specified and directed by Engr-in-Charge
Removing excavated materials to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point.for soils complete all as specified and directed
Material and labour for cleaning of potable water tank semi under ground sump capacity 5.50 lakh Litres by draining out complete residual water/dewatering of residual mud water, scrapping the internal surface walls of tanks with wire brush / brooms, for removing the fungus, algae particals , soil, sludge mud etc complete including rewashing the walls of tank with fresh water to ensure complete cleaning including painting with and including water proof antifungal epoxy paint and writing on the outer walls of the tank with and including synthetic enamel paint the date of cleaned, due date of next cleaning complete all as specified and directed including followings:- (a) Preparation of old surface shall include brooming or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots.
Material and labour for cleaning of deluge fire fighting water tank semi under ground sump capacity 2.70 lakh Litre by draining out complete residual water/dewatering of residual mud water, scrapping the internal surface walls of tanks with wire brush / brooms, for removing the fungus, algae particals , soil, sludge mud etc complete including rewashing the walls of tank with fresh water to ensure complete cleaning including white washing 2 coats on old surface and writing on the outer walls of the tank with synthetic enamel paint the date of cleaned, due date of next cleaning complete all as specified and directed including followings:- (a) Preparation of old surface shall include brooming or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots.
Material and labour for cleaning of fire Hyderant water tank semi under ground sump open type capacity 2.70 lakh Litre by draining out complete residual water/dewatering of residual mud water, scrapping the internal surface walls of tanks with wire brush / brooms, for removing the fungus, algae particle, soil, sludge mud etc complete including rewashing the walls of tank with fresh water to ensure complete cleaning including white washing 2 coats on old surface and writing on the outer walls of the tank with synthetic enamel paint the date of cleaned, due date of next cleaning complete all as specified and directed including followings:- (a) Preparation of old surface shall include brooming or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots. .
Material and labour for cleaning of fire fighting water tank semi under ground sump open type capacity 1.20 lakh Litre( Near building No 102) by draining out complete residual water/dewatering of residual mud water, scrapping the internal surface of walls of tanks with wire brush / brooms, for removing the fungus, algae particle , soil, sludge mud etc complete including rewashing the walls of tank with fresh water to ensure complete cleaning including white washing 2 coats on old surface and writing on the outer walls of the tank with synthetic enamel paint the date of cleaned, due date of next cleaning complete all as specified and directed including followings:- (a) Preparation of old surface shall include brooming or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots.
Material and labour for cleaning of satic water tank semi under ground sump open type capacity 1.40 lakhs Liters by draining out complete residual water/dewatering of residual mud water, scrapping the internal surface walls of tanks with wire brush / brooms, for removing the fungus, algae particle , soil, sludge mud etc complete including rewashing the walls of tank with fresh water to ensure complete cleaning including white washing 2 coats on old surface and writing on the outer walls of the tank with synthetic enamel paint the date of cleaned, due date of next cleaning complete all as specified and directed including followings:- (a) Preparation of old surface shall include brooming or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots.
Material/labour for routine maintenance consisting of normal repairs with periodical routine maintenance and testing of following capacity DG set complete (i.e. Engine, Alternator etc) under GE (I) R&D Pashan including provision of all consumables like cotton, waste cloth, kerosene oil etc. Maintenance will be carried out as and when ordered in writing by Engineer-in-Chagre, complete all as specified and directed comprising of maintenance the following :- (a) Change engine oil. (b) Check clearance of suction and exhaust valves and adjust if required. (c ) Changing of oil filter, fuel filters, screen filters assy. (d) Changing of water filter element. (e) Topping up of coolent. (f) Change of Hydraulic governer oil. (g) Tightening of all nut bolts. (h) Greasing of all points. (j) Checking of any leaking in fuel and oil lines. (k) Cleaning of fuel tank by taking out the dirt and sludge, cleaning the tank thoroughly. (j) Replacement of battery terminal made of Brass with necessary brazing to cable NOTE 1 : Labour charges for dismantling / taking down and replacement / refixing new parts as and when required is deemed to be included in unit rate quoted. NOTE 2 : Spare parts like oil filter, fuel filter, screen filter, by pass filter will be measured and paid separately as supply only. Other spare parts required to be replaced shall be measured and paid for seperately. (a) 62.5 KVA DG Set at pump house Bldg. HEMRL.
(b) 100 KVA DG Set at Non-Hazardous Bldg &TEG Bldg. HEMRL.
(c) 125 KVA DG Set at Small Arms, BMS Centre, AIRPP in ARDE and Admin bldg,PBX bldg, TF II, Glass blowing bldg in HEMRL
(d) 200 KVA DG Set at PZT in ARDE and HD 1.1 Bldg, Chemical Bldg in HEMRL
(e) 250 KVA DG Set at B Power House in ARDE , CADAS in ARDE & MIXER House bldg in HEMRL
(f) 380 KVA DG Set at I division Bldg. HEMRL.
(g) 625 KVA DG Set in B power house, ARDE
Material and labour in repair for battery cable of 70 sqmm, PVC insulated, multi stranded, copper conductor single core cable with and including necessary copper lugs and connections.complete all as specified and directed Make : Polycab / Finolex / ICI.
Supply and top up of Premix Ethylene Glycol coolent for Engine Radiator.complete all as specified and directed Make : castrol or equivalent make of others.
Material and labour in repairs for repair of battery terminals made out of brass with nut bolts and washers and necessary brazing to cable complete all as specified and as directed
Supply and fix in repair for flexible braided high pressure hydraulic hose including both ends chromium plated end connections check nuts and washers complete all as specified and directed for the following :- a) For by pass filter / super by pass filter.
b) For fuel supply.
c ) For fuel return.
d) For pressure guage.
e) For water vent.
Supply only by pass filter element with and including 'O' ring suitable for DG Sets complete all as specified and directed of following capacities :- (a) 250 KVA to 625 KVA
Supply only fuel filter primery and secondary with and including 'O' ring for DG Sets complete all as specified and directed of following capacities :- (a) 125 to 200 KVA
(b) 250 KVA to 625 KVA
(b) 125 KVA to 250 KVA
Supply only oil filter with and including 'O' ring for DG Sets complete all as specified and directed of following capacities:- (a) 125 to 200 KVA
(c) 250 KVA to 625 KVA
(c) 250 KVA six CT Engine
Supply and fix in repair rubber hose set with and including clamps for DG Set radiator by replacing the unserviceable hose set complete all as specified and directed for the following capacities of DG Sets :- (a) 125 KVA to 200 KVA DG Set
(b) 250KVA to 380 KVA DG Set
(c) 625 KVA DG Set
Supply and fix in repair water temperature gauge dial of dia 50mm.complete all as specified and directed Make : Yankey / Flebig or equivalent make as approved by GE.
Supply and fix in repair oil pressure gauge dial of dia 50mm.complete all as specified and directed
Supply and fix in repair oil temprature gauge dial dia 50mm.complete all as specified and directed Make : Yankey / Flebig or equivalent make as approved by GE.
Supply and fix in repair the fan belts for DG Sets,complete all as specified and directed for following Make : Fenner / Dunlop or as per existing make as approved by GE. (a) 125 to 200 DG Set
(b) 250 to 625 KVA DG Set
Supply and fix in repair ignition switch with and including key for DG set complete all as specified and directed Make : Minda or other equivalent make as approved by GE.
Supply and fix in repair LED type lamps with and including holders for DG Set control panel/AMF panel.complete all as specified and directed
Supply and fix in repair digital voltmeter 0-600 Volts complete all as specified and directed
Supply and fix in repair digital ammeter CT operated 0-200/400 amps,complete all as specified and directed
Supply and fix in repair digital frequency meter 40-55 Hz complete all as specified and directed
Material and labour in repair for AC/DC alternator of 125 to 250KVA DG Set,with replacement of burn copper wirng of the same guage and refixing the same after duly repair including testing and calibration.complete all as specified and directed
Marerial and labour in repair for cleaning of raditor,external cleaning by vaccum cleaner,petrol washing and taking out the carbon deposits from cooling fins and internal cleaning by using restor plus liquid and inhibitor corrosion of 125 KVA to 625 KVA DG Set complete all as specified and directed
Supply and fix in repair heavy duty maintenance free batteries suitable for AMF DG set of capcity 12 Volts, 100 AH including connecting brass and copper lugs with terminals.complete all as specified and directed Make : Exide or equivalent standard Amron, Tata Green, Furukawa with replacement warranty 18 Months.
Supply only diluted sulphuric acid specific gravity 1250 for lead acid batteries.complete all as specified and directed
.Supply only distilled water for batteries complete all as specified and directed
Supply and fix in repairs 4 pole power contactor , coil voltage 230/415 Volts complete all as specified and directed for following capacity :- (a ) 160 Amps - 200 Amps
(b) 225 Amps - 300 Amps
(c) 320 Amps to 400 Amps
Repair / modification of control wiring of AMF panel using AMF relay making oprative of DG Set 125 to 250 KVA including replacement of wornout spare parts complete all as specified and as directed. Note:- (i) Spares required to be replaced will be measured and paid separately as "Supply only" except certain minor /wiring of suitable size (ii) Labour charges for dismantling / taking down and replacement / refixing new parts as and when required is deemed to be included in unit rate quoted.
b) AMF relay 12/24 volts
c) Magnetic relay 12/24 volts DC
d) Push button with element
e) Single phase preventor
f) electronic battery charger 12/24 volts with AC/DC conversion
g) Control fuse with base
h) Add on block with No/NC
Supply and fill Engine oil 15 W of 40 grade or as required grade complete all as specified and as directed Make : Castrol / HP / Kirloskar or equivalent as approved by GE.
Supply, fixing, testing and commissioning in repair microprocessor DG Set controller along with and including electronic circuits and controlls DG Set of capacity 100 KVA to 125 KVA complete all as specified and as directed
Supply, fixing, testing and commissioning in repair microprocessor DG Set controller along with and including electronic circuits and controlls DG Set of capacity 200 KVA to 250 KVA complete all as specified and as directed
Material and labour in repair for self starter assembly 12 volts /24 volts suitable for of 125 to 250KVA DG Set,including replacement of burn copper wirng of the same guage and refixing the same after duly repair including testing complete all as specified and directed NOTE;- (i) Spares required to be replaced will be measured and paid separately as "Supply only" except certain minor /wiring of suitable size (ii) Labour charges for dismantling / taking down and replacement / refixing new parts as and when required is deemed to be included in unit rate quoted.
Supply only following spare parts to incorporate as per Item No 127 complete all as specified and directed :- (a) Field winding
(b) Armature assembly
(c ) Penion assembly
(d) Solenoid coil
(d) carbon brush
(e) Clutch set assembly
Supply only Petroleum Jelly in 1 Kg plastic sealed container.complete all as specified and directed
Material and labour in repair for solenoid coil for fuel pump 12/ 24 volts complete all as specified and directed
Material and labour in repair for power contactor coil for any type of contactor up to 100 Amps to 200 Amps complete all as specified and directed
Material and labour in repair for power contactor coil for any type of contactor up to 250Amps to 400 Amps complete all as specified and directed
Material and labour in repair for Automatic Voltage Regulator for 100 KVA to 250 KVA DG Set suitable for existing DG Set complete all as specified and directed
Material and labour in repair for VAF meter for AMF Panel of DG Set suitable for existing DG Set complete all as specified and directed
Material and labour in repair for Line Voltage Magager (LVM) for AMF Panel of DG Set suitable for existing DG Set complete all as specified and directed
Material and labour in repair for half overhauling of 125 KVA DG Set model NTC 495 including provision of following spares in replacement complete all as specified and directed (i) Head gasket set -01 Nos (ii) Radiator Hose set - 01 Set (iii) Hose clamp set - 01 Set (iv) Water manifold pipe - 01 No. (v) Fuel connections - 08 Nos (vi) Hose terbo oil drain with gasket - 01 Nos (vii) Necessary hardware
shakti engineering and electrical works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .