| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹52.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹55.0 L+₹2.5 L (4.74%)Rejected-Finance C O AKBAR FURNITURE HOUSE MALHAR MORH GARHI UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance OTHER THAN L-1 | |
| 3 | L3₹61.6 L+₹9.1 L (17.3%)Rejected-Finance JAGANOO PO JAGANOO JAGANOO DISTT UDHAMPUR1 UDHAMPUR JAMMU KASHMIR 182124 | UDHAMPUR | JAMMU AND KASHMIR | 182124 | L3 | Rejected-Finance OTHER THAN L-1 |
Tender Value
₹60.2 L
EMD Value
₹1.2 L
Closing Date
26 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh A K Dubey IDSE SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR TO BLDG NO P-165 (OTM ACCN) OF PARA (SF) UNDER GE (SOUTH) UDHAMPUR
2022_MES_509543_1
CWE/U(S)-109/2021-22
Open Tender
Civil Works
Item Rate
270 days
UDHAMPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE (SOUTH) UDHAMPUR
₹1.2 L
Yes
31 Mar 2022
21 Feb 2022
28 Mar 2022
21 Feb 2022
26 Mar 2022
14 Mar 2022
60 days
Amount
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engr-in-Charge.
Demolition of Reinforced Cement Concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engr-in-Charge.
RCC M-25 Design mix, (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engr-in-Charge. Note: Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed by Engr-in-Charge.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and includingMS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. , complete all as specified and as directed by Engr-in-Charge.
Non skid, coloured ceramic jointfree/rectified tiles 8 to 9mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Glazed coloured ceramic jointfree/rectified tiles of size (600x300mmx7mm/450mm x 300mm x 7mm) thick in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match, over and including 10 mm thick rendering on fair faces of brick/concrete surfaces works in cement mortar 1:3 finished rough for receiving tiles, complete all as specified and as directed by Engr-in-Charge.
Machine cut kota stone slab flooring 18-20 mm thick over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including Screed bed or bedding layer of mortar 20mm thick in cement mortar 1:3, complete all as specified.
Machine cut kota stone slab flooring 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 10 mm thick CM 1:3 mortar backing for fixing the stone slab, complete all as specified.
150mm wide strip of makrana white marble 18-20 mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing over and including 20 mm thick CM 1:3 mortar backing for fixing the stone slab, complete all as specified.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Grouting 25 mm thick for damaged ceiling,columns, beams, chajjas, parapets etc. including any temporary shuttering to edges with cement mortar 1:2 including strengthening with cement based polymer modified coating for corrosion protection and hard drawn steel wire fabric cut to length bent to shape as required, complete all as specified and as directed by Engr-in-Charge.
Preparation new surfaces plastered or unplastered and applying three coats of white wash on ceiling all as specified
Preparation old surfaces including complete removal of existing treatment ( white wash) and applying two coats of white wash on ceiling all as specified
Preparing newly plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of suitable primer, complete all as specified and as directed by Engr-in-Charge.
M&L preparation of old surfaces, plastered or unplastered of wall (including facia) and applying two coats of weather proof exterior emulsion paint (apex) painting on walls complete all as specified and as directed by Engr-in-Charge.
Preparation old surfaces including complete removal of existing treatment and applying two coats of cement base paint on wall, complete all as specified and as directed by Engr-in-Charge.
Applying two coats of oil bound distemper over and including a coat of primer including preparation of new plastered/ unplastered surfaces of wall incl 3 mm thick wall care putty, complete all as specified & directed by Engr-in-Charge.
Description all as Srl item No 25 above but removal of existing treatment including preparation of old plastered surfaces of wall.
Supply only liquid water proofing compound, complete all as specified & directed by Engr-in-Charge. (Make : Dr Fixit, LW+, STP Ltd No 1 (L) & SIKA or equivalent as specified in PS)
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt. ) , complete all as specified and directed by Engineer-in Charge.
Description all as per item No 28 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete, of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, including filling voids with PCC 1:3:6 type C-0 complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 30 above but frame size 105 x 60 mm.
35 mm thick, factory made, 2nd class hard wood, plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed by Engr in Charge.
35mm thick, factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete, all as specified and directed by Engr in Charge.
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all specified and as directed. Notye : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 (ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Description all as per item above No 34 but without glazing bar complete all as specified and as directed.
Factory made mild steel ventilators box type with upper top hung glazed and gauzed shutters and bottom fixed type glazed shutters including pintol hinges, steel peg stay and one shop coat of red oxide primer complete all specified. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3. ii) MS fillets, glazing, wire gauge shall be measured and paid for separately
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed by Engr-in-Charge.
S&F welded steel wire fabric mesh weight n.exc 4 Kgs per sqm fixed to steel members complete all as specified and directed.
Rolled mild steel work of angle iron as in frames of doors & Cup Board etc conforming to grade Fe -410 (E-165) complete all as specified.
Plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) for filling in the pressed steel door frame/hold fast complete all as specified and as directed by Engr-in-harge.
Cutting holes exceeding 150 sq.cm but nexc 400 sq.cm in to brick walls built in CM 1:3 and making good in cement concrete 1:2:4 type B1 for fixing of cooler brackets etc complete all as specified and as directed by Engr-in-harge.
Mild steel cold rolled butt hinges medium weight 75 mm log fixed to steel /angle iron frame by welding, if required complete all as specified and as directed by Engr-in-harge.
Mild steel, plain, 1.25 mm thick black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and as directed by Engr-in-harge.
Hasp and staple, 100 mm size safety type aluminium anodised with mild steel hinges pin, including bolt to hinge plate and fixed with screws, complete all as specified and as directed by Engr-in-harge.
4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and as directed by Engr-in-harge.
4 mm thick figured glass (frosted) ,pin head type and glazing with oil putty not exc 0.50 Sqm in each pane fixing to window/ventilator complete all as specified and as directed by Engr-in-harge.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed by Engr-in-harge. (ISI Mark)
250 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed by Engr-in-harge. (ISI Mark)
150 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed by Engr-in-harge. (ISI Mark)
150 mm aluminium handles, cast type anodised complete all as specified and as directed by Engr-in-harge. (ISI Mark)
100 mm aluminium handles, cast type anodised complete all as specified and as directed by Engr-in-harge. (ISI Mark)
Aluminium drapory rods of 25 mm dia decorative type with wooden finish alongwith holding for brakets & end caps fix in repairs complete all as specified and as directed by Engr-in-harge.
Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specifiecation and drawings complete all as specified.
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specification & drawing as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Preparation of wooden surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including one coat of pink primer complete all as specified and as directed by Engr-in-Charge.
Preparation of new steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of zink chrome primer complete all as specified and as directed by Engr-in-Charge.
Preparation of old steel and iron surfaces exceeding 10 cms width or girth and applying two coat of synthetic enamel paint, complete all as specified and as directed by Engr-in-Charge.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed by Engr-in-Charge
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 59 above but except bricks.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius in half brick thick built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Providing cement concrete in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, 1:2:4 mix type B-0 complete all as specified and as directed by Engr-in-Charge.
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm including 10mm thick screeding in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately). Applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3.50 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm, complete all as specified and as directed by Engr-in- Charge. Note :- Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency/applicator which will further have to rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise.
Providing 75 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints through out the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified & directed by Engr-in-Charge.
Water closet (Orissa pattern) including lime concrete bedding, vitreous china long pan orissa pattern 580x440mm, white with integral foot rests (excluding flushing cistern & flush pipe) fixed in repairs complete all as specified and as directed by Engr-in-Charge.
10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, fixed in repair complete all as specified and as directed by Engr-in-Charge.
S&F in repairs vitreous China wash down water closet pan pedestal pattern, white (excluding fixing bolts, flushing cistern and flush pipe) with P or S trap but including plastic water closet seal, seat cover ,white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device including connection to drain and flush pipe complete all as specified and as directed by Engr-in-Charge.
Aluminium anodised tubular towel rail, 20mm dia, D type, 60cm long between flanges aluminium anodized, fixed with rawl plugs, fixed in repair complete all as specified and as directed by Engr-in-Charge. (ISI Mark)
Steel peg set colour coated of six as per sample in repairs complete all as specified and as directed by Engr-in-Charge.
Dismantling cast iron pipe & reinforced concrete drain pipes, jointed in cement mortar of any dia taking out from trenches or fixed to wall upto 100mm complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 100mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 75mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall of 100mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall of 75mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall of 50mm bore, complete all as specified and as directed by Engr-in-Charge.
Salt-glazed stoneware gully traps, size 150 x 150 mm, square or round mouthed, type 'P', including setting and jointing to drains with cement mortar 1:1, fixed in repairs, including demolition of old unserviceable gully traps complete all as specified (ISI Marks).
Cast iron bends (any radius diminishing pieces or tapes (larger bore measured), 75mm bore fitted with oval access door fixed with rubber ring joints as in repairs complete all as specified and as directed by Engr-in-Charge.
Cast iron bends (any radius diminishing pieces or tapes (larger bore measured), 100mm bore fitted with oval access door fixed with rubber ring joints as in repairs complete all as specified and as directed by Engr-in-Charge.
75mm Cast iron floor traps with grating including jointing to waste pipe fixed cncrete type B1 (1:2:4), complete all as specified and as directed by Engr-in-Charge. (ISI Mark)
Cast iron branch pieces, single/double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 100 bore, fitted with oval access door as in repairs complete all as specified and as directed by Engr-in-Charge.
Cast iron branch pieces, double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 75 bore, fitted with oval access door as in repairs complete all as specified and as directed by Engr-in-Charge.
50mm Cast iron cowls as in repairs complete all as specified and as directed by Engr-in-Charge.
Cast iron Reducer 100mm by 50mm for connecting and fixing gas pipe on walls as in repairs complete all as specified and as directed by Engr-in-Charge.
Cast iron Reducer 75mm by 50mm for connecting and fixing gas pipe on walls as in repairs complete all as specified and as directed by Engr-in-Charge.
Taking down eaves gutters and and rain water pipes (any size or pattern ), including all fittings incl removal of store and sold to contractor through credit.
110 mm bore PVC SWR bends and fixed solvent etc complete all as specified and as directed by Engr-in-Charge. (ISI Marked)
110mm bore, PVC (SWR) pipes, pressure rating 4 kg/sqcm, single or double socketed, in any length with rubber ring joints, fixed to wall, complete all as specified and as directed by Engr-in- Charge.
Stack clamps out of 50mm by 5mm flat iron and 6mm dia round iron stays,including bolts and nuts and securing ends of stays to wall or roof for 75 mm bore of pipe complete all as specified and as directed by Engr-in-Charge.
Stack clamps out of 50mm by 5mm flat iron and 6mm dia round iron stays,including bolts and nuts and securing ends of stays to wall or roof for 100mm bore of pipe complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:5:10 type E-2 using 40mm graded crushed stone aggregates as in sunken floor/ foundation, complete all as specified and as directed by Engr-in-Charge.
Vitreous china urinal, half stall type white incl CP Spray Nozzale including PVC waste pipe, providing and fixing plugs bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement , flush pipe, grating and union for discharge pipe, incl PVC waste pipe 32mm dia, complete all as specified and as directed by Engr-in-Charge.
S&F in repairs plain, Aluminium sheeting 0.56 mm thick , Alloy 31000 H4 in ridges, hips, valley gutter, drip ,construction joints and straight flashing (length and girth as fixed) , complete all as specified and as directed by Engr-in-Charge.
Dismantling water tank of capacity exceeding 1000 litres but not exceeding 2000 ltrs each and removing from site/to store, complete all as specified and as directed by Engr-in-Charge.
Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 2000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), complete all as specified and as directed by Engr-in-Charge.
Bib taps, long body, fancy type cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Stop valves, fancy type, chromium plated, cast copper alloy, with long shank and cup (concealed type) screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 15mm fixing in repair, complete all as specified and as directed by Engr-in-Charge.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 20mm fixing in repair, complete all as specified and as directed by Engr-in-Charge.
Stop valves/Angle valve, fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge. Make : Jainko Cat Part No CSV-1 or equivalent of makes specified in PS.
Soap dish fancy type chromium plated fixed with brass screws and wooden/plastic cleats complete all as specified and as directed by Engr-in-Charge.
Brass Chromium plated over head shower rose of dia 125mm with swivel joint fixed to pipe or union of 15mm bore, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
32mm size waste coupling of PTMT (half or full threaded) (Minimum weight 32mm-45gms/40mm-60 gms) complete all as specified and as directed by Engr-in-Charge.
32 mm dia PVC waste pipe, for low level cistern, complete all as specified and as directed by Engr-in-Charge
Taking up or down steel tubing of 15 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 20 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
15mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified.
20mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified.
Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc., 15 mm bore, complete all as specified and as directed by Engr-in-Charge.
Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc., 20 mm bore, complete all as specified and as directed by Engr-in-Charge.
PVC connection 15mm size with PTMT nuts of length 450mm, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Providing and injecting Along the external wall below concrete or masonry apron using Antitermite Treatment chemical emulsion @ 2.25 litres per running metre including drilling and plugging holes etc. in apron. complete all as specified and as directed by Engr-in-Charge. Note : The treatment work shall be carried through authorised agency only, and certificate for the same for waranty shall have to be furnished before submitting payment)
Providing and injecting Antitermite Treatment of soil under existing floors using emulsion @ 1 litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand to match the existing floors complete all as specified and as directed by Engr-in-Charge. Note : The treatment work shall be carried through authorised agency only, and certificate for the same for warranty shall have to be furnished before submitting payment)
100mm thick Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in foundation, filling and mass concrete, complete all as specified and as directed by Engr-in-Charge.
Factory made, Machine pressed / vibro mechanically floated coloured interlocking cement paver block ISI marked, glossy finish any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, with topping of cement with imported pigment including 25-30 mm thick sand cushioning bed including spreading levelling watering if required, Shape shall be approved by Engr-in-Charge.
Plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in steps, seismic and other similar bands, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, cills, lintels upto 1.50 metre clear span, copings etc. and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form works, complete, all as specified and directed by Engr-in-Charge.
M&LProviding precast cement concrete block masonary with soild blocks, exc.10cm in width and setting in cement mortar , kerbs stone all as directed, 1:2:4 mix type B-1, complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth in any type of soil and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Demolition and breaking up drain pipe SGSW , jointed in cement mortar of any dia taking out from trenches or fixed to wall upto 150mm complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200mm bore pipes complete all as specified and as directed by Engr-in-Charge. Note:-(i) Thickness of bed below barrel of pipe-10 Cms. (ii) width of bed- outer dia of pipe plus 30 cms.
Reinforced concrete pipes 200mm bore ,class NP2,laid and jointed complete with collars etc. complete all as specified and as directed by Engr-in-Charge.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as specified and as directed by Engr-in-Charge.
Pre-cast cement concrete 1:2:4 type B-I (20mm graded) as in manhole cover slab, chullah hoods and in similar works bedded and jointed in cement morter 1:4, complete all as specified and as directed by Engr-in-Charge.
10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4, finished even and fair without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 150mm bore pipes, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foudation, filling, sub base and mass concrete all as specified.
Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted , built in cement mortar 1:6 complete all as specified and as directed by Engr-in-Charge.
Description all as per description of serial item No 130 here in before but except stone.
Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in surface channels and drains including necessary form work, complete all as specified and as directed by Engr-in-charge.
Extra for forming fair finished drain or channel exc 30cm inner girth in cement concrete ,using extra cement ,incl forms moulds ,mitered/stopped ends etc, complete all as specified and as directed by Engr-in-charge.
Plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in steps, seismic and other similar bands, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, cills, lintels upto 1.50 metre clear span, copings etc. and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form works, complete, all as specified and directed by Engr-in-Charge.
M&L for precast cement concrete 1:3:6 type C1 using 20mm graded crushed stone agregate bonders for stone walling set in cement mortar 1:6 with plain fair faces including chamfers weathering etc, complete all as specified and as directed by Engr-in-Charge.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses of granite or trap stone etc. and hammer dressing with maximum depression on face from straight edge held against the dressed surface n exc. 40mm complete all as specified and as directed by Engr-in-Charge.
110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, as in weep hole, complete all as specified and as directed by Engr-in- Charge.
Raised pointing to random or polygonal rubble, uncoursed or brought upto courses stone masonry in Cement Mortar 1:4 complete all as specified and as directed by Engr-in-Charge.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLSH) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light / bell /exhaust fan controlled by one switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for switches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLSH 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLSH) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light / bell /exhaust fan controlled by two no two way switches with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for switches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLSH 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 140 above but one 3/5 pin 6 Amp socket outlet on the same board with other switch.
Description all as per item No 140 above but one 3/5 pin 6 Amp socket outlet on independent board .
Description all as per item No 140 above but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLSH cable 4 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLSH 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Switch piano flush button single pole one way 5 Amp, 240 Volts, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Switch piano type 5 Amps single pole two way 240 volts complete all as specified and as directed by Engr-in-Charge.
Socket outlet, 2 in 1, 3 pin, 5 Amp flush type , fixed in repair complete all as specified and as directed by Engr-in-Charge.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 Amp flush type, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 & 15/16 Amp flush type, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Stepped type fan regulator 120W, 230V 50 C/S, electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically fixed in repair complete all as specified and as directed by Engr-in-Charge.
Taking down ceiling fan/ exhaust fan and cable etc. and refixing/hanging the same after repair/replacement of damaged/worn out parts like canopy 02 Nos, down rod, clamps with nuts, bolts and washers, rubber bush, greasing, oiling and provn of cable from ceiling rose to fan, etc. including painting with two coats of synthetic enamel white paint and writting Ser No/Mes No with black paint complete, all as specified and as directed by Engr-in-Charge. Note:- (i) The spares like condensor, ball bearing , cotter pin, nuts & bolts, connecting rods & hooks etc if found defective/ damage deemed to be replaced and make the ceiling fans functional. No extra pavements will be done on this account.
Bell (ding dong type), AC electronic type, 230 volts, single pole ,fixing in repairs, complete all as specified and as directed by Engr-in-Charge.
Bell push 6 Amps 230 volts fixed in repair complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used TPN 4 way 415V with 200 Amps rated bus bar, double door type with IP-43, IK-49 protection with appropraite size bus bar and neutral link fixed flush in wall including cutting chases in walls for fixing DB and making good disturbed wall surfaces to match the existing specifiactions ,fixing in repairs complete all as specified and as directed by Engr-in-Charge.
Supply and fixing MCB FP 40 Amp 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning, complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed by Engr-in-Charge.
MCB SPN, 40 to 63 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, fixed in repair, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SPN, 32 to 40 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, fixed in repair, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SP, 6 to 32 Amps,240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable fixed in repairs, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLSH PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC concealed rigid conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 4 Sqmm (1x4sqmm ) single core FRLSH PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 4 Sqmm (1x4 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 2.5 Sqmm ( 2x2.5 sqmm ) 1100 volts grade single core FRLSH PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 1.5 Sqmm (1x1.5sqmm ) single core FRLSH PVC insulated unsheathed copper conductor cable as earth wire, in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 2.5 Sqmm (2x2.5sqmm ) ,one run of 1.5 Sqmm (1x1.5 sqmm ) cable and one metre of conduit will be measured as one unit.
Earthing (in repair) complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 163 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Earthing (in repair ) complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 165 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
New generation energy saving and environmental friendly long life LED street light of 30 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing, fixed in repair complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 150 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Street light Bracket complete made of GI pipe 25mm bore, light grade of suitable size, 1.2m long bent to shape as per site requirement alongwith MS flat iron clamps with nuts, bolts, washers including grouting the same with wall, complete all as per the direction of Engg-in-Charge.
Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 20Watt LED with integral electronic driver complete making connection and testing after fixing fixed in repair complete all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Decorative ultra slim linear surface mounted LED lighting fixture (2 feet length), 10 Watt LED with integral electronic driver complete making connection and testing after fixing fixed in repair complete all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 100 lm/W (e) System Lumens : Not less than 1000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.9 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 25 sqmm 4 core including taking up/down old unserviceable cables fixed in repair. complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed by Engr-in-Charge. NOTE Only punned thickness shall be measured for payment purpose.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles fixed in repair complete all as specified and as directed by Engr-in-Charge.
M/S ASHOK KUMAR PACHIALA
KALSOTRA CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .