| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹14.6 L+₹44,340.33 (3.13%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹16.3 L+₹2.2 L (15.4%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹16.7 L+₹2.5 L (17.6%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹17.1 L+₹3.0 L (20.9%)Rejected-Finance 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹39,000
Closing Date
28 Oct 2020, 6:00 pmClosed
CWE Patiala
HQ CWE, Bldg No 26, New Lal Bagh Patiala 147001
SPECIAL REPAIR TO LT DISTRIBUTION NETWORK BY CONVERSION OF LT OH LINE INTO UNDER GROUND CABLE AT OFFICERS ACCN AT FAD DAPPAR
2020_MES_381784_1
8320/PAT/T-43/2020-21
Open Tender
Electrical and Maintenance Works
Lump-sum
120 days
Dappar
As per cover 1
6 documents required · 6 mandatory
₹500
Yes
GE (Project) Dappar
₹39,000
Yes
19 Dec 2020
29 Sept 2020
30 Oct 2020
29 Sept 2020
28 Oct 2020
16 Oct 2020
29 Sept 2020 - 5 Oct 2020
Amount
Schedule 'A'Section-I (EXTERNAL ELECTRIFICATION WORKS)
Total amount of Sch 'A' Sec I (External Electrification Works)
Schedule 'A'Section-II (Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Taking down old unserviceable cable of any size complete all as directed by Engineer in Charge.
Dismantling of GI pipe of any size complete all as directed by Engineer in Charge.
M&L for supplying, installing, testing and commissioning of factory fabricated, floor mounted, IP 65 grade, DOUBLE DOOR, outdoor type LT cubical panel of length 610mm, depth 610mm & height 915mm, made out of CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032 of size as per IEC 61439 1&2 norms. Panel should be mounted/grouted on 150 mm thick PCC (1:4:8) type D2 with 100 mm offsets complete. The bottom of the panel (space between bottom of panel and top of PCC foundation) shall be covered with 3 mm thick CRCA sheet covering all the sides of the base frame duly painted with two coats of synthetic enamel paint of approved shade over one coat of red oxide primer. The panel should have following accessories fitted in :-
(i) MCCB 160 Amps ,415 V 4 pole 36 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type, including spreader terminals - set of 04 and direct rotary handle -01No as per OEM specifications - 01 No.
(ii) MCCB 63 Amps, 415 V 4 pole 18 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type ,including spreader terminals - set of 04 and direct rotary handle - 01No as per OEM specifications- 02 Nos.
(iII) MCB 06-32 Amps, 415 V, TPN, 10 KA 50 Hz, 'C' series all as per OEM specifications - 01 Nos.
(Iv) LED indicators - R/Y/B 240 V AC - 12 Nos. - 03 Nos per Incoming and outgoing feeders.
(v) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours and including suitable size CTs (set of 3) - 01 Nos. (01 No. each for Incoming and Outgoing feeders) all equivalent model as per the OEM of the panel.
(vi) MCB SP 'C' series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps) and multifunction meter - 01 Nos.
(vii) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc.
(viii). Suitable size aluminium bus bars for phase and neutral.
NOTE - (i). Quoted rate is deemed to be inclusive of dismantling of old panel, M&L for jobs required at site like, cutting, welding etc. required at site for installation, testing and commissioning of panel all to the satisfaction of Engr-in-Charge. (ii). Detailed specs of panel is specified in the PS schedule of this tender.(iii) Panels should be manufactured by the CPRI approved firm. (iv) Design of panel to be approved by Engineer in Charge and GE prior to manufacturing and installation.
M&L for supplying, installing, testing and commissioning of factory fabricated, floor mounted, IP 65 grade, DOUBLE DOOR, outdoor type LT cubical panel of length 762mm, height 915mm & depth 610mm, made out of CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032 of size as per IEC 61439 1&2 norms. Panel should be mounted/grouted on 150 mm thick PCC (1:4:8) type D2 with 100 mm offsets complete. The bottom of the panel (space between bottom of panel and top of PCC foundation) shall be covered with 3 mm thick CRCA sheet covering all the sides of the base frame duly painted with two coats of synthetic enamel paint of approved shade over one coat of red oxide primer. The panel should have following accessories fitted in :-
(i) MCCB 63 Amps, 415 V 4 pole 18 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type, including spreader terminals - set of 04 and direct rotary handle - 01No as per OEM specifications and model - 01 Nos.
(ii) MCB 06-32 Amps, 415 V, TPN, 10 KA 50 Hz, 'C' series as per OEM specifications and model - 10 Nos.
(iii) LED indicators - R/Y/B 240 V AC - 12 Nos. - 03 Nos per Incoming and outgoing feeders.
(iv) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours , including suitable size CTs (set of 3) - 01 Nos. (01 No. each for Incoming and Outgoing feeders) all equivalent model as per the OEM of the panel.
(v) MCB SP 'C' series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 11 Nos. LED lamps) and multifunction meter - 01 Nos.
(vi) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc.
vii). Suitable size aluminium bus bars for phase and neutral.
NOTE - (i). Quoted rate is deemed to be inclusive of dismantling of old panel, M&L for jobs required at site like, cutting, welding etc. required at site for installation, testing and commissioning of panel all to the satisfaction of Engr-in-Charge. (ii). Detailed specs of panel is specified in the PS schedule of this tender.(iii) Panels should be manufactured by the CPRI approved firm. (iv) Design of panel to be approved by Engineer in Charge and GE prior to manufacturing and installation.
M&L for supplying, installing, testing and commissioning of factory fabricated, floor mounted, IP 65 grade, DOUBLE DOOR, outdoor type LT cubical panel of lenght 610mm, height 915mm & depth 610mm, made out of CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032 of size as per IEC 61439 1&2 norms. Panel should be mounted/grouted on 150 mm thick PCC (1:4:8) type D2 with 100 mm offsets complete. The bottom of the panel (space between bottom of panel and top of PCC foundation) shall be covered with 3 mm thick CRCA sheet covering all the sides of the base frame duly painted with two coats of synthetic enamel paint of approved shade over one coat of red oxide primer.The panel should have following accessories fitted in :-
(i) MCCB 63 Amps, 415 V 4 pole 18 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type , including spreader terminals - set of 04 and direct rotary handle - 01No as per OEM specifications and model - 01 Nos.
(ii) MCB 06-32 Amps, 415 V, TPN, 10 KA 50 Hz, 'C' series as per OEM specifications and model - 04 Nos.
(iii) LED indicators - R/Y/B 240 V AC - 15 Nos. - 03 Nos per Incoming and outgoing feeders.
(iv) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hours and including suitable size CTs (set of 3) - 01 Nos. (01 No. each for Incoming and Outgoing feeders) all equivalent model as per the OEM of the panel.
(v) MCB SP 'C' series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 11 Nos. LED lamps) and multifunction meter - 01 Nos.
(vi) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc.
(vii). Suitable size aluminium bus bars for phase and neutral.
NOTE - (i). Quoted rate is deemed to be inclusive of dismantling of old panel, M&L for jobs required at site like, cutting, welding etc. required at site for installation, testing and commissioning of panel all to the satisfaction of Engr-in-Charge. (ii). Detailed specs of panel is specified in the PS schedule of this tender.(iii) Panels should be manufactured by the CPRI approved firm. (iv) Design of panel to be approved by Engineer in Charge and GE prior to manufacturing and installation.
Supply and fix cable jointing kit for 1100 v grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 core XLPE, armoured, Al conductor cable of size upto 50 sqmm, outdoor type and taking down fault complete all as specified and directed by Engineer in Charge.
Supply and fix weather proof outdoor type made KIOSK box complete with 3 phase and nutral connection suitable to 3 numbers phase cable with end termination joint and housing for one MCB SP 6 Amp including MCB SP 6 Amp on pole with help of FI clamp including nuts and bolts and washers etc complete all as specified and directed by Engineer in Charge.
M&L for . Boring horizontally / inclined 150 mm dia by mechanical means using trenchless technology under the road / hard surface to passing through cables / pipes complete all as directed by Engineer in Charge.
Material and labour for LT cable route indicator / marker with ingreev 'LT Cable" on block made out of PCC of size 800x150x80mm fixed in ground at a distance 50 Mtrs complete all as specified and directed by Engineer in Charge.
ACESOLARR RENEWABLE ENERGY LLP
AK Construction Co
M/S Sonu Traders
Arneja Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .