Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC 93 1 PREMPURI KANKER KHERA MEERUT INDEX NO E MER 81 HQ CWE MEERUT | L1 | Accepted-AOC Found lowest and reasonable | |
| 2 | L2₹29.1 L+₹1.1 L (4.10%)Rejected-Finance | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹30.4 L+₹2.4 L (8.55%)Rejected-Finance | L3 | Rejected-Finance In order but L3 | |
| 4 | L4₹31.5 L+₹3.5 L (12.4%)Rejected-Finance 164 197 NEWAJPUR DASAULI KURSI ROAD LUCKNOW UTTAR PRADESH 226026 | LUCKNOW | UTTAR PRADESH | 226026 | L4 | Rejected-Finance In order but L4 | |
| 5 | L5₹31.7 L+₹3.7 L (13.1%)Rejected-Finance 4 3 KISHANPUR RAJPUR ROAD DEHRADUN UK | L5 | Rejected-Finance In order but L5 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
26 Feb 2024, 6:00 pmClosed
GE (U) Meerut Cantt
Roorkee road Meerut Cantt
CLEANING, PAINTING AND MARKING OF OVERHEAD RESERVOIR AT VARIOUS PUMP HOUSES OF SOUTH AREA OF AGE E/M (WS) UNDER GE (U) MEERUT CANTT
2024_MES_640784_1
8564/E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
Meerut
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE (U) Meerut Cantt
₹90,000
Yes
6 Jun 2024
5 Feb 2024
28 Feb 2024
5 Feb 2024
26 Feb 2024
19 Feb 2024
Amount
Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets light fitting etc removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per condition seprately) and making good disturbed surfaced of wall , floors etc complete all as specified and as directed by Engr-in-Charge.
Taking down carefully sub-main wiring of any type/description including battens/ casing caping on surface and making good to the disturbed surface to match the existing, complete all as specified and as directed by Engr-in-Charge.
M&L Point wiring surface type with 1.5 sqmm (nominal area) PVC insulated stranded single core unsheathed FRLS copper conductor cable 1100 Volts grade drawn through with and including PVC concealed conduit of 20mm dia or hingher, medium grade complete with and including all PVC accessories (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 1.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FR copper cable as earth continuity wire connecting to common earth point with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of screws and washers etc. for mounting switches, sockets, regulatros etc complete) for One light point or one fan point or exhaust fan controlled by one switch including cutting holes in or through the walls, making good the walls, ceilling etc including two coats of white / colour washing/ distemprering etc to the disturbed surfaces ro match the existing complete all as specified and as directed
-ditto- but for one 3 pin socket outlet, 6 Amp on the same board with other switches
-ditto- but for one 3 pin socket outlet, 6 Amp on the independent board with other switches
M&L Point wiring surface type with 2.5 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLS copper conductor cable 1100 Volts grade drawn through with and including PVC concealed conduit of 20mm dia or hingher, medium grade complete with and including all PVC accessories (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FR copper cable as earth continuity wire connecting to common earth point (with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. for mounting socket combination for 5 pin, 16 Amp on independent board including cutting holes in or through the walls, making good the walls, ceilling etc including two coats of white / colour washing/ distemprering etc to the disturbed surfaces ro match the existing complete complete all as specified and as directed.
M&L Sub main wiring with 4.0 sqmm (Nominal area) with two runs of single core FRLS PVC insulated stranded unsheathed copper conductor cable upto and including 1100 V grade drawn through PVC concealed conduit of 20mm diafixed to wall/ ceilling etc incl one runs 4.0 Sqmm (nominal area) single core, FRLS PVC insulated stranded unsheathed copper conductor as earth wire and duly connected to common earth point etc. complete all as specifed and as directed. Note: Two runs of 4 sqmm single core cable, one run of 1.5 sqmm earth continuity wire and one run of PVC casing caping shall be measured as one length.
M&L Sub main wiring with 2.5 sqmm (Nominal area) with two runs of single core FRLS PVC insulated stranded unsheathed copper conductor cable upto and including 1100 V grade drawn through PVC concealed conduit of 20mm dia fixed to wall/ ceilling etc incl one runs 2.0 sqmm (nominal area) single core, FRLS PVC insulated stranded unsheathed copper conductor as earth wire and duly connected to common earth point etc. complete all as specifed and as directed. Note: Two runs of 2.5 sqmm single core cable, one run of 1.5 sqmm earth continuity wire and one run of PVC casing caping shall be measured as one length.
S&F in repairs surface and wall mounted LED batten, 1 X 20 Watt, 4 feet, 240V, including T-8 poly carbonate diffuser type 20 watt rectrofit tube rod all as specified.
S&F stepped type fan regulator for ceiling fan of sweep 1200/1400 mm stepped type 230 volts, 100 watt flush mounted complete all as specified and as directed.
M&L Ceiling rose, surface type polycarbonate/bakelite, 65 x 50 mm three terminals, conforming to IS, complete all as specified and as directed
S&F Switch piano, flush type 5 amps, 240 volts, single pole, one way, conforming to IS complete all as specified and as directed.
S&F Socket outlet 2 in 1, 5 pin 5 Amps flush type conforming to IS complete all as specified and as directed.
S&F Switch piano, flush type 15 amps, 240 volts, single pole, one way, conforming to IS complete all as specified and as directed.
S&F Socket outlet 2 in 1, 6 pin, 15 Amp flush type 240 volts, single pole, one way, conforming to IS complete all as specified and as directed.
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting complete all as specified & directed
S&F in repairs SPN DB, IP 43 protection, double door, 240 volts, 8 way incl taking down existing DB complete all as specified and directed.
S & F repairs MCB SP 6 to 32 A, AC, 240V, 10KA ISI marked all as specified
S & F repair Isolator DP, 40A, AC, 240V, ISI marked all as specified
S&F in repairs Earth continuity conductor of 25 x 3.0 mm aluminium strip fixed to wall or on batten or recess or chases or burried in ground or drawn in conduit pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and as directed by Engineer-in-charge.
S&F in repairs GI strip 32 x 6mm with porcelain saddles fixed to wall or recess or chases or burried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and all as directed.
Supply and fixing LED street light fittings 25 Watt 230V AC out door type with high pressure die cast alluminium housing and heat resistantcomplete with driver, lamp bracket with impect and corrosion resistant complete and as directed by Engr-in-Charge.
Taking out old unserviceable post top lantern of any type and supply and fixing of post top lantern Clear/Milky defuser, spun cover, Die cast, IP 65, Module with LED. The lantern to include 25 watt LED light/bulb fitting(Warm/White) complete all as specified and directed by Engr-in-Charge Note: The rate quoted are deemed to include cost of fittings,bolts, nur, brackets CA required & all other labour/accessories
Supply and fixing 10 Sqmm flat twin core, 1100 Volts grade, heavy duty, Aluminium stranded conductor cable served with PVC inner sheathing and overall PVC insulated for service connections and suspended by insulating hangers not more than one meter apart including 4 mm GI suspension wire from LT pole to service brackets after and including taking out the existing unserviceable cable,GI, wire etc complete all as specified and directed.
Supply and fixing 06 Sqmm flat twin core, 1100 Volts grade, heavy duty, Aluminium stranded conductor cable served with PVC inner sheathing and overall PVC insulated for service connections complete all as specified and directed.
M&L for seven stage cleaning and sterilization inside the existing RCC overhead tank of capacity of 25000 gallon through bacteriological and fungal treatment by using sodium hypochlorite, potassium permanganate /E-in-C's Branch approved chemical as recommended by Engr-in-Charge and ULTRA VOILET RAY at Pump house at any height (as per site requirement), including suitable staging/scalfolding seven stage are as under follows:- (a) First stage is to drain out the water by using high capacity pump of dewatering system. (b) Second stage is cleaning all the stage formation inside the tank by using sodium hypochlorite a laboratory tested branded chemical/ E-in-C's Branch approved chemical as recommeded by Engr-in-Charge. (c) Third stage is scrubbing the walls and floor with mechanised scrubber and fresh water cleaning high speed jet pump (Rotary & flat) to remove all scalling algae abd other formed particlaes on internal surfaces of the tank completely. (d) Fourth stage and first fungal screening is sterilization by using potassium permangate, Laboratory certified and tested chemical E-in-C's Branch approved chemical as recommended by Engr -in-Charge, test certificate from government laboratory monitoring suitability for sterilization should be submitted to the office before using stralisation. (e) Fifth stage is cleaning the floor of water tank by heavy duty industrial vaccume cleaners and sludge succor having maximum 1200 watt with suitable heavy duty rugged motor to free any foreign and loose particales of any nature (f) Sixth stage is providing UV radition which shall have 360 degree off sterilization with in the tank to kill all suspended bacteria (The radition shall portable and effective for sterilization of drinking water tanks for diminetion of floeting and suspended bacteria.) (g) Seventh stage of cleaning is to sterlizes the floor of the water tank by using branded strong oxidizing agernt non toxic bio-degredable eco-friendly anti-bacterial agent (high potency sodium hypochlorite) certified by a Govt. approved laboratory to disinfect the over head tank from all harmful pathogens. (h) Cleaning of, lid wall of the tank, structure for all scales and other particles any algae, hives and any type of vegetation of any other unwanted matters.
(i) A sticker of appropriate size and colour as directed by Engr-in-Charge and of non degrable material with printed details as under :-Tank capacity, date of cleaning and expiry date will be written or printed on the sticker by permanent marking ink. (J) painting of angle iron ledder for OHT after scrapping of old paint by emery paper or any other means with two coat of enamelled black paint over a coat of red oxide primer including arrangement of bamboo structure required for entire work. (K) The wire mess of ventilaters of the tank shall be replaced with new GI wire mesh. (L) Testing of water sample of OHT each before as well as after cleaning which is to be include the following tests: (i) Chemical and Physical : - Colour, odour, taste, turbodity, PH, total hardness, iron, chloride, free residue chlorine, fluoride, total dissolve solid, calcium, magnesium (ii) Biological testing:- E- coli, Coliform as per IS from any govt NABL approved laboratories and submission of test report complete all as specified and directed by Engr-in- Charge. Note:-(i) Collection of Sample of water shall be done by the authrozied rep of the approved laboratry from whom the testing of water is to be carried out (ii) All required safety equipemnts (Gumboot, helmets, safety belts, safety foogles, torch light etc) and necessary insurance for safety of working staff to execute the work is resposibility of the contractor. (iii) Lighting arrangements if required to be provided by the contractor temporarily at his own arrangements and the amount quoted for that is deemed to be inclusive in the unit rate and electricity/disel shall not be provided by the MES. (iv) Contractor will not be allowed more than one day to do the work inside of the each OH tank /UG sump to prevent interruption of water supply to the users.
All as per item No 26 above but the capacity of the tank is 50000 gallon
All as per item No 26 above but the capacity of the tank is 100000 gallon
All as per item No 26 above but the capacity of the tank is 200000 gallon
All as per item No 26 above but for the UG Sumpof capacity 20000 to 25000 gallon up to 5.0 meter depth
M & L for Semi/UG reservoir water proofing by Epoxy coating of any size height of staging by using mechanical means by carry out the following stages of water proofing by epoxy coating process for disinfection of surfaces:- (a) De water the tanks and drying it up. (b) Make suitable scaffolding as needed for the work (c) Preparing the wall by scrubbing by wire brush where it is needed. (d) Patching the uneven surface withAqua Arm Top Guard a two component cementitious acrylic polymer disperson based protective coating. (e) Apply first Coat of water base portable water grade resin based epoxy Aqua Arm tank coat at the inner surface of the tank.
Repair of valve pit chamber of brick masonary valve pit of size 1000 X 1000 X1000 mm (Internal dimensions ) including all excavation and earth work in any type of soil and disposal of soil to a distance of not exceeding 50mtr and depositing all as directed including 10mm plastering internally in CM 1.4PCC 1:2:4 100mm thick at bottom and top of valve pit, and MS Sheet 3mm thick at with angle iron frame 35X35X5mm and 40X40X5mm at bottom for minting and MS sheet cover inle. Handle locking arrangement inlc two coats of synthetic enamel paint (Make Asian Ist quality ) over a coal of red oxide primer on steel surface complete
M&L for earthing of Over head tank of any type and capacity complete with galvanized steel earth plate electrode 60cm x 60 cm x 6 mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized earth strip 25x4 mm by means of bolts, nuts, check nuts and washers of GI or steel surrounded with adequate quality of charcoal dust mixed with salt on all side of earth plate including complete earthwork PCC 1:2:4 chamber and RCC 1:2:4 cover all as shown in electrical plate No 5 and all as specified and directed by EIC Note:- If desired earth resitance not found, earthing shall be redone by the copntractor at no extra cost to the department
Supply and fixing including taking down old Cast iron flanged Non-return valve, class PN-1, suitable for 200 mm bore CI/DI pipes as per IS-5312 Rub-Bronze and SS pin construction incl fixing in position with by providing flanged joints, nuts, bolts, washers rubber gasket etc as required complete all as specified and directed by Engr-in-Charge.
All as per Srl item No: 30 above but suitable for 150 mm bore CI pipes.
Taking down and refixing after repair of existing Cast iron flanged Non-return valve any make of size 200 mm bore CI pipes as per IS-5312 Rub-Bronze and SS pin construction incl fixing in position with by providing flanged joints, nuts, bolts, washers etc as required complete all as specified and directed by Engr-in-Charge.
Taking down and refixing after repair of existing Cast iron flanged Non-return valve any make of size 150 mm bore CI pipes as per IS-5312 Rub-Bronze and SS pin construction incl fixing in position with by providing flanged joints, nuts, bolts, washers etc as required complete all as specified and directed by Engr-in-Charge.
Taking down and refixing after repair of Cast iron strainer with strainer plate 150 mm bore in Supply line of OH Tank . Note:- The quoted rates are deemed to include packing, nut bolts for suitable, removing old stainer plates and refixing the new stainer plates at existing place all as specified and directed by EIC.
Taking down and refixing after repair of Cast iron strainer with strainer plate 200 mm bore in Supply line of OH Tank . Note:- The quoted rates are deemed to include packing, nut bolts for suitable, removing old stainer plates and refixing the new stainer plates at existing place all as specified and directed by EIC.
Supply and fixing including taking down old Cast iron strainer 150 mm bore both ends flanged and fixing at Supply line of over head tank complete all as specified and directed by Engr-in-Charge. Make:- SIR/BIR/VARVN/MINAR
Supply and fixing including taking down old Cast iron strainer 200 mm bore both ends flanged and fixing at Supply line of over head tank complete all as specified and directed by Engr-in-Charge. Make:- SIR/BIR/VARVN/MINAR
S & F including taking down old sluice valve PN-1.6 with stainless steel spindle conforming to IS-14846-2000 doubles flange and including new flanged rubber joints complete suitable for following sines including necessary outs bolts gas with washer and rubber gasket of following sizes :-
250mm dia bore
200mm dia bore
150mm dia bore
100mm dia bore
Taking down and refixing after repair of existing Cast iron sluice valve any make of size 150 mm bore CI pipes with stainless steel spindle conforming to IS-14846-2000 doubles flange and including rubber joints complete flanged joints, nuts, bolts, washers etc as required complete all as specified and directed by Engr-in-Charge.
Taking down and refixing after repair of existing Cast iron sluice valve any make of size 200 mm bore CI pipes with stainless steel spindle conforming to IS-14846-2000 doubles flange and including rubber joints complete flanged joints, nuts, bolts, washers etc as required complete all as specified and directed by Engr-in-Charge.
Dismantling wrought iron or mils steel work of any description and any height.
M & L framed work such as grills gratings, ladder etc, woth ends of bars shouldered and / or riveted or forged into spiles, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, framework of existing ladder at OHT and underground sump adn similar work conformin g to Fe-290, Gde-E-165 directed.
M & L new or previously untreated surfaces of any description, over 10cm in width or firth, nototherwise sescribed red oxide, zinc chrome and two coat of synthetic enameled paint, for compleete all as specified and directed.
Disconnecting and Taking out old existing CI/ GI pipe and connecting of any description / grade and any position of trenches / under floors/ on walls etc including connecting fitting / accessoriese and fixtures such as bend, union, elbow socket etc. all as directed and specified for the following size of pipe:-
150mm dia bore
100mm dia bore
50mm dia bore
40mm dia bore
25mm dia bore
20mm dia bore
15mm dia bore
M & L DI/CI Specials class B as per IS such as bends, tappers,any type branches cross all sockets and spigot collar caps and plug up to 150mm bore all as specified and as directed
M & L Ductile iron pipes with spigot and socket ends, centrifugally cast (spun) class K9, in any length, externally coated with metallic Zinc Coating finished with bituminous paint complete all as specified of the following bore:- Note :- Excavation, earthwork and GI clamps shall be measured and paid separately)
150mm dia bore
100mm dia bore
S & F GI tubing, medium grade, ISI marked complete with all fittings, laid in trenches or laid under gloors, fixed on walls with and providing clamps etc complete all as specified & directed, for the following size:-
50mm dia bore
40mm dia bore
25mm dia bore
20mm dia bore
15 mm dia bore
S & F long length CI Detachable joint complete with nuts, bolts, washers and rubber ring (Set) suitable for 150mm nominal bore CI/DI pipe complete all as specified.
S & F long length CI Detachable joint complete with nuts, bolts, washers and rubber ring (Set) suitable for100mm nominal bore CI/DI pipe complete all as specified.
S & F long length CI Detachable joint complete with nuts, bolts, washers and rubber ring (Set) suitable for 80mm nominal bore CI/DI pipe complete all as specified.
S & F long length CI Detachable joint complete with nuts, bolts, washers and rubber ring (Set) suitable for 50mm nominal bore GI pipe complete all as specified.
M & L Gun metal gate valve with iron wheel head screwed both ends for iron pipe including tasting of following :-
50mm dia bore
25mm dia bore
20mm dia bore
M&L for directional boring for 180mm dia and up to 1.5m depth with hydraulic machine under any surface ( Hard/Deuse/ RCC/ Coal tar Road) for laying of pipeline including trenching if required . Cost of horizontal Bore Machine (hydraulic) & all allied itemes required for boring is deemed to be included in qnoted Rates
M & L cement concrete type B-1 1:2:4 (20mm grade stone aggregate) as in door cills, path and plinth protection (of any section)including chambers, weatherings, throat-ing etc and setting in mortar complete all as specified and directed.
Excavation in trenches in soft/lose soil n.exc. 1.5M wide & n exc 1.5M deep for laying of GI/CI pipe line & getting out including forming bottom surface all as specified and directed.
All as per item No. 54 above but in Hard/dense soil including cutting of roads/PCC floors etc.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layer n.exc. 250 mm in any type of soil after the pipe laid & tested complete all as specified and directed.
Removing excavated surplus soil to a distance n.exc. 50mtr and depositing where directed at a level n.exc. 1.5 m above the starting point all as specified and directed
NITHYA INFRATECH
CHAUDHARY FURNITURE HOUSE
SIYA ASSOCIATES
M/S RAJESH AGARWAL
M/S JPS Electrical Engineer & Contractor
BHAGWAN DAS & Co
yameen enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .