Executive Engineer(E)
Judiciary Electrical Division-I, PWD, Yamuna Western Bank, Lok Nayak Setu, New Delhi-110002
Replacement of PTAC Plant Units at Karkardooma Court Complex Delhi.
2026_PWD_290687_1
29/EE(E)/JED-1/PWD/2026-27
Open Tender
Electrical Works
60 days
Karkardooma Court Complex
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1.9 L
11 May 2026
30 Apr 2026
8 May 2026
30 Apr 2026
8 May 2026
30 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Supplying, Installation, Testing and Commissioning of air -cooled Floor Mounted Package Type Air Conditioner with R-410a refrigerant. The unit shall be supplied in two portions –outdoor portion & indoor unit made up of the evaporator coil made out of copper tube & aluminium fins adequate face area & evaporator fan, 2 nos. Scroll compressors, Microprocessor controlled electric panel and Outdoor unit comprising air cooled condenser made of copper tube & aluminium fins, condenser fan complete in all respect & specifications. Dismantling of old PTAC Indoor & outdoor condensing unit along with refrigerant piping with brazing, after installation of outdoor condenser unit new installed 2 circuit piping of 21/22 / 23 TR PTAC plants, leak detection, flushing pressure testing & vacuumizing the system and charging of refrigerant etc. complete as required. (Without refrigerant). The Package AC Shall be QCO compliant, As per IS 8148 Standard) | 17 | Each | 4,72,000 | ₹80,24,000 | BI01010001010000000000000515BI0100014 |
| 2 | Charging of Refrigerant R 400/410a after re-installation Pressure testing, plants, Leak Detection, Repairing, flushing & vacuumizing the system of condenser/ Cooling Coils in the units of damage 2 Circuits of 21/22/23 TR PTAC etc. required as per site. | 580 | Kg | 1,020 | ₹5,91,600 | BI01010001010000000000000515BI0100015 |
| 3Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : | ||||||
| 3.01 | 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm | 578 | Mtr. | 904 | ₹5,22,512 | BI01010001010000000000000515BI0100017 |
| 3.02 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 425 | Mtr. | 487 | ₹2,06,975 | BI01010001010000000000000515BI0100018 |
| 4Supplying, Fixing, testing and commissioning of fire dampers of minimum 90 minutes fire rated in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal and, in confirmation to IS and as per specifications complete etc. as required.. | ||||||
| 4.01 | Fire damper | 5 | Sqm | 11,355 | ₹56,775 | BI01010001010000000000000515BI0100020 |
| 4.02 | Actuator | 17 | Each | 10,645 | ₹1,80,965 | BI01010001010000000000000515BI0100021 |
| 5 | Duct connection with Plenum | 17 | Each | 2,500 | ₹42,500 | BI01010001010000000000000515BI0100022 |
| 6 | Duct connections to the unit shall be made by inserting a double canvas sleeve fire rated as per NBC 100 mm long. The sleeve shall be securely bonded and bolted to the duct and unit casing. | 17 | Mtr. | 4,000 | ₹68,000 | BI01010001010000000000000515BI0100023 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.76 MB
BOQ_385729.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid