Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹35.9 L+₹1.7 L (4.87%)Rejected-AOC B 3 3 DHANALAXMI PARK OPP PMT BUS DEPOT BHUSARI COLONY PAUD ROAD KOTHRUD PUNE 411 038 | PUNE | PUNE | MAHARASHTRA | 411038 | L2 | Rejected-AOC L2 | |
| 3 | L3₹41.9 L+₹7.6 L (22.3%)Rejected-AOC MINISTRY OF DEFENCE MES G | L3 | Rejected-AOC L3 | |
| 4 | L4₹47.9 L+₹13.6 L (39.7%)Rejected-AOC 123 23 1 SHRISANT APARTMENT MANGALMURTI NAGAR PASHAN SUTARWADI ROAD PASHAN PUNE MAHARASHTRA 411021 | PUNE | MAHARASHTRA | 411021 | L4 | Rejected-AOC L4 |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
6 Jul 2020, 5:00 pmClosed
GERD PASHAN PUNE
GERD PASHAN PUNE
Addn Altn to Arjun Hall (Sports complex) (Bldg No 385) at DRDO Estate Pashan
2020_MES_312664_3
GERD/PSN/TOKEN/41 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
GERD PASHAN PUNE
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GERD PASHAN PUNE
₹72,000
Yes
28 Jul 2020
8 Jun 2020
11 Jul 2020
9 Jun 2020
6 Jul 2020
23 Jun 2020
9 Jun 2020 - 22 Jun 2020
Amount
Demolition of cement concrete (Unreinforced) of roof, beams, staircases, landings, chajjas including removing APP Membrance and removing rubbish to a distance exceeding 100 metre and n.exc 250 metre complete all as specified and as directed.
Material and labour for brushing neat cement slurry with 3.0kg of cement per sq. metre mixed with approved integral liquid water proofing compound conforming to IS:2654 as per manufacturer's recommendations over the RCC slab and sides upto 300mm high complete all as specified and as directed. Note :- WPC will be measured and paid separately as supply only.
Material and labour for PCC 1:2:4 type B-1 40 mm thick, (using 20mm graded crushed stone aggregates) as in levelling course/padding/coving on roof/sunken slab or chajjas etc to level the undulations of roof or to maintain the slope of roof etc complete all as specified and as directed.
Material and labour for screed bedding 10 mm thick in Cement mortar (1:3) on green concrete surfaces over roof slab using liquid integral water proofing compound to be mixed with mortar as per manufacturers instruction and same mortor shall be used over the fillet between vertical and horizontal concrete surfaces complete all as specified and as directed. Note :- WPC will be measured under separate as supply only
Material and labour for APP based polymeric memberane minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric(wt not less than 160 gms/sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 litre/Sqm by forced action complete all as specified and as directed. Water roof treatment consist of as under:- (i) Applying one coat of bituminous primer conforming to IS-3384 @ 0.3litre per sqm (ii)Laying APP based memberance as specified thickness and weight (iii)Applying one coat of bitumen grade 85/[email protected] Kg/Sqm (iv)Applying once coat of aluminium paint @ 100ml/Sqm
Supply only Liquid water proofing compound from manufacturer Fosroc/Dr Fixit/Pidilite complete all as specified and as directed.
Material and labour for PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregates)as in roof kerbs or mud stops, rounded or chamfered on edges and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerb stone and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and as directed.
Dismantling water tanks of capacity Exc 500 liter and n exc 1000 litre complete all as specified and as directed.
Supply and fix Rotational moulded polyethlene ISI Embossed water storage tank 1000 litres capacity (cylindrical vertical with closed top) double layered hoisted and fixed in position all as specified in SSR part I complete all as specified and as directed.
Material and labour in repairs for Gun-metal, globe or gate valves,20 mm dia with iron wheel head, screwed both end for iron pipe complete all as specified and as directed.
Material and labour in repairs for PTMT ball valve , 20 mm dia high pressure, with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed.
Material and labour for Complete removal of existing paint/distempered surface by scrapping, washing down etc and preparation of plastered or unplastered brick or concrete wall surface and applying two coats of oil bound distemper over and including a coat of primer including 3mm thick interior wall care putty on wall surfaces.complete all as specified and as directed.
All as per item No 12 above but two coat of white wash on ceiling
Material and labour for Complete removal of existing paint/distempered surface by scrapping, washing down etc and preparation of plastered or unplastered brick or concrete wall surface and applying two coats of interior acrylic emulsion emulsion paint over coat of primer including 3 mm thick interior wall care putty on wall surfaces complete all as specified and as directed.
Material and labour for Complete removal of existing treatment on external surface of brick wall/ concrete by scrapping, washing down etc.and preparation of plastered or unplastered brick or concrete surface of wall and applying two coats of exterior weather proof acryalic emulsion paint over and including a coat of alkali resistant primer complete all as specified and as directed.
Supply and fix in repairs vitrious china urinal, full stall type complete including CP self closing 15mm bore tap(Push Cock) , 32mm CP coupling, CP bottle trap, 32mm waste pipe fixing brackets plugs etc complete all as specified and as directed. Make :- Jaguar Cat No. ALD769L or equivalent in make as specified in Appendix 'B'
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified and as directed.
Material and labour for 30 mm thick PCC (1:2:4) type B0 using 12.5 mm graded crushed stone aggregate as base for laying floor finishes complete all as specified and as directed.
Material and labour for vitrified ceramic double charged/ultra charged tiles 10mm thick (square/Rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles etc including and over 15mm thick screed bed in cement mortar 1:4 for laying floor tiles etc complete all as specified and as directed.
All as per Item No 19 here in before but as in skirting/dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to match etc over and including 10 mm thick backing coat in Cement mortar 1:3 etc complete all as specified and as directed.
Material and labour for Non skid ceramic coloured tiles of 7 mm to 8 mm thick (Sqare / rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles etc including and over 15 mm thick screed bed in Cement mortar 1:4 for laying floor tiles etc complete all as specified and as directed..
Material and labour for glazed ceramic colour tiles of size 300mmx600mmx7mm thick in vertical surfaces as in skirting, dados and risers to steps etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles including and over 10 mm thick rendering in Cement mortar 1:3 for laying tiles in vertical surface etc complete all as specified and as directed.
Material and labour for non skid ceramic coloured tiles of 7 mm to 8 mm thick (Square / rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match etc including and over 15 mm thick screed bed in Cement mortar 1:4 for laying floor tiles etc complete all as specified and as directed.
Supply and fix in repair Vitreous china wash basin, white colour, under counter basin oval,shape size 550mmx400mm (Make Jaquar CNS-WHT-WB03) including brackets, CP bottel trap (Make: ALD-769L), fancy type 15mm bore CP pillar tap (Make: Jaquar CON-011KN), CP angular stop cock (Make: Jaquar CON-059KN), 450mm connection pipe (Make: Jaquar ALD-803AB) and CP waste couplig (Make: ALD-705). or equivalent in make as specified in Appendix 'B' for all items complete all as specified and as directed.
Supply and fix in repair CP grating 125 mm dia round with waste hole fixed on floor/Nahani trap fixed with solvent cement complete all as specified and as directed.
Material and labour in repair for 100mm dia CI Nahani Trap with and including grating including jointing to waste pipe fixed in cement concrete ( PCC 1 : 2 : 4)type B1 using 20 mm graded crushed stone aggregate complete all as specified and as directed.
Supply and fix in repairs for 75mm PVC (SWR) multi floor trap, plain with and including CP grating including jointing with solvent cement.complete all as specified and as directed.
Material and labour in repairs for PVC(SWR) gully trap 125 mm/110 mm size setting and jointing with solvent cement complete all as specified and as directed.
Supply and fix in repair 75mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
Supply and fix 75mm dia PVC(SWR) bend any radius with access door complete all as specified and as directed.
Supply and fix 75mm PVC(SWR) branch piece single(single) equal or unequal with access door complete all as specified and as directed.
Taking down steel tubing 15 mm dia and connection, complete all as specified and as directed.
Taking down steel tubing 20 mm dia and connection, complete all as specified and as directed.
Supply and fix steel water tubing 15mm bore medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floor complete all as specified and as directed.
Supply and fix steel water tubing 20mm bore medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floor complete all as specified and as directed.
Material and labour for Cutting chases in Stone, concrete block wall or slab , pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and as directed.
Material and labour for Granite (of any type) work 18mm-20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in including and over 15mm thick screed bed in Cement mortar 1:4 and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform,and other similar work complete all as specified and as directed.
Supply and fix in repairs CP Tabular towel rail 20mm dia 'D' type 60 cm long between flanges complete all as specified and as directed.
Supply and fix in repairs brass chromium plated health foucet standard length of 1.00 meter or 1.20 meter long complete all as specified and as directed. . Make: Jaquar ALD-573 or equivalent in make as specified in Appendix 'B'.
Supply and fix in repairs 15mm bore CP fancy type Bib tap, cast copper ally with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. Make: Jaquar CON-037KN or equivalent in make as specified in Appendix 'B'.
Supply and fix in repairs 15mm bore CP fancy type two way bib cock, screwed for iron pipe or for brass ferrule. complete all as specified and as directed.Make: Jaquar CON-041KN or equivalent in make as specified in Appendix 'B'.
Supply and fix in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed.
Supply and fix in repair CP toilet paper holder with flap fixed in wall (recessed type) complete all as specified and as directed.. Make Jaquar AHS-1553 or equivalent in make as specified in Appendix 'B'.
Dismantling of Plain or corrugated/ semi corrugated steel sheeting, any gauge, thickness, and in any position etc complete all as specified and as directed.
Supply and fix Pre-painted galvalume aluminium zinc coating curved GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws at any height and at any places complete all as specified and as directed.
Supply and fix Pre-painted galvalume aluminium zinc coating GI based PLAIN steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws at any height and at any places complete all as specified and as directed.
Supply and fix Roof top ventilator 2100 CFM dia 24" (600 mm dia) Wind Driven in stainless steel 304 grade with and including UV treated FRP base plate Wind ventilators including cutting and making good existing ceiling of roof any type, sealing and making water tight complete all as specified and as directed. Make : Mukta Engineers/ Sudha ventilators or equivalent make as approved by GE
Taking down cement plaster on brick / concrete / stone surface including raking out joints, hacking for key scrubbing down with water etc.complete all as specified and as directed.
Material and labour for rendering 10mm thick on brick masonry surfaces or surfaces other than fair faces or on one side of lathing in cement mortor 1:6 and finished even and smooth without using extra cement.complete all as specified and as directed.
Material and labour for rendering 15mm thick on brick masonry surfaces or surfaces other than fair faces of brick work or on one side of lathing in cement mortor 1:4 in two layer (i e first layer 10mm thick and second layer 5mm thick using WPC as per manufacturer's instructions) and finished even and smooth without using extra cement complete all as specified and as directed. Note: Supply only WPC shall be measured and paid seperately.
Material and labour for Rendering 5 mm thick in cement mortar 1:3 on ceiling finished even and smooth without using extra cement complete all as specified and as directed..
Material and labour for preparation of newly plastered surfaces and applying two coats of oil bound distemper over and including a coat of 3mm thick wall care putty and primer on wall surfaces.complete all as specified and as directed.
Material and labour for preparing new ceiling surfaces of plastered or unplastered and applying three coats of white colour wash on ceilling complete all as specified and as directed.
Material and labour for Preparation of old painted steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint at any height complete all as specified and as directed.
Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) (unreinforced) complete all as specified and as directed.
Material and labour for PCC 1:3:6 type C-2, (using 40mm graded crushed stone aggregate) as in plinth protection,75 mm thick, finished the surface fair and even without using extra cement complete all as specified and as directed.
Forming Construction joint 30mm deep x 10mm wide filled with sealing compound grade 'A'complete all as specified and as directed.
Taking down chowkats or frames (Without taking of shutters from the frame) not exceeding 1.5 Sqm each incl all fittings etc complete all as specified and as directed.
Supply and fix solid PVC door frame of size 50mmX47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS Square tube complete all as specified and as directed.
Supply and fix Factory made solid moulded panel PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement.complete all as specified and as directed.
Supply and fix 125mm long Aluminium, anodised, barrel tower bolt of extruded section complete all as specified and as directed.
Supply and fix 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
Supply and fix 100mm long Butt hinge, heavy weight, cold rolled mild steel, complete all as specified and as directed.
Supply and fix 125mm long Extruded aluminium alloy handle, fabricated type., anodised complete all as specified and as directed.
Taking down Chowkats or frames exceeding 1.5 Sqm but not exc 4 sqm each (Without taking off shutters from the frame)complete all as specified and as directed.
Supply and fix Aluminium anodised powder coated frames for doors, windows, ventilators, grill with one or more rebates including joints cleats for fixing etc, complete all as specified and as directed. (Minimum thickness of powder coating shall be 50 micron)
Supply and fix power coated aluminium door shutters, aluminium section weighing 0.55kg/meter including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and as directed.
Supply and fix in repairs Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet including foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed.
Supply and fix in repairs aluminum composite sheet cladding including using 4 mm thick sheet of approved make consisting of a core of 3mm natural polyethylene core sandwitched between two skins (0.5mm each) of aluminum alloy with outer surface in all colour coating of PVDF paint in fully automatic coil coating process. The PVDF coated finished surface to factory protected with self-adhesive peel off foil tested to withstand at least 6 months exposure to local weathering conditions. The composite sheet cut and bend to shaped profiles as required to, including perimeter extrusions base frame, extruded stiffeners, expansion fasteners and silicone sealant (Dow corning 789) required for installation as per approved elevation drawing. Work includes necessary accessories complete in all respects. The rates shall be including the cost of all materials, tools, tackles, manpower, fuel, consumables, lead and lifts at all levels. Design, fabrication, erection, finishing, erecting and dismantling of scaffolding and testing of water tightness, etc. as per instruction of manufacturer's complete all as specified and as directed. make: ALSTRONG or equivalent as approved by GE.
Supply and fix 4.00 mm thick plain glass, and glazing with and including Al glazing clip in squares exceeding 0.5 Sqm in each pane all complete all as specified and as directed.
Supply and fix Solar control film 25 micron reflective type(gareware sun control or equivalent)complete all as specified and as directed.
Supply and fix in repairs 3 mm thick Figured glass, pin head type and glazing in squares n. exc 0.5 sq.m in each pane.complete all as specified and as directed.
Dismantling of exsting floor concrete using concrete cutting machine for required depth and size for further provision of wooden flooring and making good complete. Note: Dismantling shall be done using concrete cutting machines without damaging the adjacent concrete surface.complete all as specified and as directed.
Material and labour for wooden flooring using Kiln seasoned imported Teak Wood surface board 21 mm thick, 55mm to 85 mm width and in random length as required in tounge and groove shape laid over and including frame work of commercial quality Fir/Spruce/Pine wood runners of size 70 mm x 45mm fixed @ 350mm centre to centre along short side treated with and including antitermite solution and fixed on the bottom side with and including10 mm thick EPDM air cushioning pads below full length of runners by nails through the two wings as per manufacturer's instructions complete all as specified and as directed.
Material and labour for painting floor marking on wooden surface using water based paint in two coats including preparation of surface, as per Indian Sport Standard complete all as specified and as directed.
Disconnecting existing badminton court net poles to carry out nrcessary repair works and refixing in new or old position incuding provision of necessary nuts, bolts, washers etc including necessary excavation and earthwork , PCC 1:2:4 type B1 using 20mm graded crushed stone aggregates, formwork if any, finished exposed surface and painting two coats with synthetic enamel paint including preparation of old steel surafaces complete all as specified and directed.
Taking down carefully copper/AImn point wiring (Light,Fan/Point Socket or power) (fittings such as switches ceiling roeses, pendent, regulators, sockets etc all included in the rates) & making good to disturbed surface of walls/floors etc.
Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as ceiling fitting, bulk head fittings and tube light/ light fittings etc and making good the distrubed surfaces complete all as directed by Engr-in-Charge
Taking down carefully existing ceiling fan and air circulators from site and deposited to MES store as per direction of Engr-in-Charge.
Supply & Fix ceiling fan complete with all accessories 230 V, 1200mm sweep. BEE 5 star rated as per direction of Engr-in-Charge complete all as specified and directed. Make : ES-50 of Havell's or equivalent make as specified in Appx 'B'.
Supply & fix air circulator complete with all acessories 230 V, 600mm sweep as per direction of Engr-in-Charge complete all as specified and directed. Make : Turbo Force of Havell's or equivalent make as specified in Appx 'B'.
M&L point wiring using approved colour coding as per IS with stranded copper conductor single core 1.5Sqmm (Nominal area), FRLS PVC insulated FRLS cable in and incl surface PVC casing-n-caping ISI marked with all connecting accessories including PVC box of required size as per site requirement, incl PVC insulated copper conductor 1.5 Sqmm (Nominal area) single core PVC FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified for the following:- Note : Switch/sockets to be measured and paid for separately (a) One light point controlled by one ; one way switch
(b) One Fan/Exhaust point controlled by one ; one way switch
(c) One 3 pin 5 Amp socket out let controlled by one switch independent board.
(d) One 3 pin 5 Amp socket out let controlled by one switch same board.
All as per item No 83 here-in-before but using 2.5 sqmm stranded copper conductor cable PVC insulated drawn with 2.5 Sqmm stranded copper conductor cable PVC insulated as continued earth wire
Supply & fixing switch piano, flush type, 6 Amp, single pole, one way complete all as specified and directed.
Supply & fixing socket outlet 5 pin 6 Amp surface type complete all as specified and directed.
Supply & fixing switch socket combination 2 in 1, 3/5 pin 5 Amp flush type universal complete all as specified and directed.
Supply & fixing switch socket combination 2 in 1, 3/5 pin 5/16 Amp flush type universal complete all as specified and directed.
Supply & fixing ceiling rose, surface bakelite, 3 terminals, 65x50mm complete all as specified and directed.
Supply & fixing stepped type electronic fa regulaor flush type on the existing/new phenolic sheet etc as required at site complete all as specified and directed.
Taking down carefully MCB DB's after sealing the cable end by unscrewing from boards/outlet boxes carefully and making good the distrubed surfaces complete all as directed by Engr-in-Charge.
Supply fixing & testing of new sheet metal enclosure distribution board SPN 8 way double door type including making good to the disturbed surface all as specified and as directed Note : All incoming/out going MCBs shall be measured and paid under appropriate item here in after.
Supply & fix MCB single pole 5-30 Amps capacity 10 KA, 240 Volts AC 50 Hz
Supply & fix MCB single pole and neutral 32 to 40 Amps capacity 10 KA, 240 Volts AC 50 Hz
Supply & fix new LED decorative luminaires 20 watts extruded heat shrink provided for efficient heat deception and integrated electronic driver luminaries LED as light sources housing complete with all accessories internally prewired all as specified and as directed. Make :Havell' s Model - LUMILINEPLUSB20WLED865SPCSS equivalent in make as specified in Appendix 'B'.
Supply & fix new LED decorative luminaires 10 watts extruded heat shrink provided for efficient heat deception and integrated electronic driver luminaries LED as light sources housing complete with all accessories internally prewired all as specified and as directed. Make :Havell' s Model - LUMILINEPLUSB10WLED865SPCSS equivalent in make as specified in Appendix 'B'.
Supply & fix new generation energy saving environmental friendly, long life, exclusive innovative die-cast aluminium IP-65 flood light with high power LEDs of 120W as light source, suitable for highlighting architectural facade highmast and general purpose lighting, interchangeable electronic driver high efficiency longer life, protection against high surges , high /low voltage cutoff, open/short circuit protection and high power factor LEDs as light source including fitted on existing street light pole bracket complete all as specified and as directed.
Supply, laying and testing of LED Rigid Lights 44 feet (440 Watt approximate) length including aluminium sections, clamps & clips with connection wire complete all as per site requirement and all as directed.
Supply & fix Jet Towel, 230V complete all as specified and directed. Make - Kimberly/Mitsubishi or equivalent as approved by GE.
Taking down sub main wiring of any size, type complete and making good the disturbed surfaces complete all as specified and directed.
Material & labour for sub main wiring using two single core 4 sqmm copper conductor,FRLS cable in including FRLSPVC casing caping of suitable size,including one run of PVC insulated copper earth continuity wire of 4.0 sqmm and connected to earth dolly including cutting chases for concealed conduit wiring complete all as specified and as directed. Note :- 2 run of 4 sqmm & 1 run of 4 sqmm will be measured in 1 run
Material and labour earthing complete with galvanised steel earth plate electrode 600 x 600 x6.0mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with the top edge of plate not less than 1.5 mtr below normal ground level and connecting to using 4mm GI wire by means of GI nuts, bolts check nuts and washers earth lead protected by 20mm dia GI pipe light grade and connected to main distribution board/earthing test point including testing on completion . Notes : The unit rate shall also including for excavation, earth work in any type of strata, plain cement concrete 1:3:6 mix, type C-1 pit, 40mm thick RCC 1:2:4 mix, type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways, GI funnel with GI watering pipe 20mm dia light grade, wire mesh, protection pipe 20mm dia light grade for earth complete. No extra payment will be made against this item.
Supply and fixing of exhaust (ISI marked) fan of 230mm sweep five star rated single phase 230 volts, 50 Hz, 1400 RPM with air delivery 1300CMH including fixing with nut bolts, clamps, connections and other wall surface work complete all as specified and directed.
Baljeet Singh Choudhari
sanjay m. suryawanshi
R. K. Industrial Fabricators
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .