Executive Engineer (BM-I) Elect.
Room No- 4, 3rd floor, Mohan Singh Place, BKS Marg, New Delhi-110001
SITC of VRV units in the Council Room, 3rd Floor Palika Kendra Building, New Delhi.
2020_NDMC_189014_1
36/EE(E)BM-I/2019-20
Open Tender
Electrical Works
Works
30 days
Palika Kendra Building
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹17,222
Yes
16 Mar 2020
2 Mar 2020
12 Mar 2020
2 Mar 2020
12 Mar 2020
2 Mar 2020
Amount
Part - A Supply of air cooled variable refrigerant flow modular compact type condensing units, each comprising of 100% inverter scroll compressors, full charge of refrigerant gas (R-410A), lubricating oil and all accessories as per the specifications. The condensing units shall be suitable to work with cooling & heating only. The condensing units shall be suitable for operation on 415 ± 10% volts, 50hz, single phase ac power supply and the condensing units shall be of following capacities. variable refrigerant volume / flow system comprising of the following items: Make: Hitachi / Mitsubishi Electric Outdoor condensing units 5 HP
Hi wall indoor units 2.0 ton
Refrigerant ‘Y’ joint required for distribution of refrigerant in copper piping etc complete as per specifications
Part - B Lifting shifting installation, testing & commissioning of air cooled variable refrigerant flow modular type condensing units, each comprising of 100% inverter scroll compressors, full charge of refrigerant gas (R-410A), lubricating oil and all accessories as per the specifications. The condensing units shall be suitable to work in both cooling and heating mode. The condensing units shall be suitable for operation on 415 ± 10% volts, 50hz, single phase ac power supply and the condensing units shall be of following capacities. Outdoor condensing units 5 HP
Hi-wall indoor unit 2.0 ton
Commissioning of VRF systems including topping R-410A gas per site requirements
Copper refrigerant piping with insulation Supply, installation, testing & commissioning of high pressure copper refrigerant piping suitable for R- 410A refrigerant of following size as required and duly insulated with 19mm/13mm thick closed cell elastomeric nitrile rubber insulation in tubing form. External refrigerant piping shall be laid on the existing gi covered cable trays. Piping inside occupied spaces shall be supported by using supplying & fixing of suitable MS hangers duly painted with black enamel paint. Entire refrigerant piping work is carried out in accordance with the specifications. pipe size min. wall insulation (size thickness) 25.4 mm dia/19 mm thick insulation
19.05 mm dia/19 mm thick insulation
15.9 mm dia/13 mm thick insulation
12.7 mm dia/13 mm thick insulation
9.5 mm dia/13 mm thick insulation
6.35 mm dia/13 mm thick insulation
Condensate drain piping ø 25 mm dia
MS stand for condensing unit
Supplying & drawing control cum transmission cable of size 2 core x 1.5 sq mm, copper conductor PVC insulated PVC sheathed unarmored in the existing steel / PVC conduits pipes between indoor and outdoor unit including making connections at both ends etc. complete as required.
SITC of 40A DP isolator with enclosure
Sujit Electricals And Airconditioning Works
H R REFRIGERATION AND ELECTRICAL WORKS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .