| 1 | L1₹19.9 LAccepted-AOC C 125 A KUNWAR SINGH NAGAR NANGLOI NEW DELHI 110041 | NEW DELHI | WEST DELHI | DELHI | 110041 | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹20.6 L+₹70,805 (3.55%)Rejected-Finance MAGADH COLONY ROAD NO 5 GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹21.9 L+₹2.0 L (10.1%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹22.1 L+₹2.2 L (10.9%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹23.5 L+₹3.6 L (18.1%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹25.1 L
EMD Value
₹50,200
Closing Date
4 Jan 2021, 6:00 pmClosed
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR Pin-273008
SPECIAL REPAIRS AND RESURFACING OF MT BADMINTON COURT AT OFFICERS MESS FLOORING OF BASKETBALL COURT AT CANDIDATES MESS AT MT SECTION AND PROVISION OF SECURITY LIGHT ALONG THE PERIMETER OF A1 DEFENCE LAND AT SURVEY NO 171 AT 4 AFSB VARANASI UNDER GE A
2020_MES_396280_2
8749/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF) GORAKHPUR
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE(AF) GORAKHPUR
₹50,200
Yes
4 Feb 2021
19 Dec 2020
5 Jan 2021
19 Dec 2020
4 Jan 2021
28 Dec 2020
Amount
Demolition of cement concrete un-reinforced in ground floors and paving not exc 15 cm thickness below or above ground level complete all as specified and as directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete or sub base of floor complete all as specified and as directed.
M&L for 100mm thick PCC 1:2:4 type B-1 using 20mm graded mechanically crushed stone aggregate as in floor laid in alternate panels finishing the by brooming complete all as specified and directed.
M&L for forming 12mm thick expansion joints of 100 mm thick concrete filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound grade-A complete all as specified and directed.
M&L for one coat of heat resisting paint on surfaces of any description wood, steel, iron, concrete, brick, stone, etc. n exc 10cm in width or girth complete all as specified and directed.
Removal of building/rubbish material etc to a distance of exc 1.0 Km but n.exc. 1..5 Km including loading unloading transporting & depositing other than MOD land where directed at a level not exc 1.5 mtrs above the starting point complete all as specified and directed. (Each load 0.62 Cum)
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for cable trench complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note: Punned thickness shall be measured for the purpose of payments.
Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
S&F 40mm bore GI pipe, light grade with all fittings laid in trenches, road crossing and fixed to walls, on poles etc for cable protection complete all as specified and directed.
All as per item No. 12 above but for 50mm bore pipe.
Boring of holes horizontally for laying of 50 mm dia pipe (minimum depth 0.75 Mtr from top level) under road, Pavement, hard standing complete all as specified and directed.
Supply, laying and testing 10 Sqmm, 4.0 Core XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, galvanised steel strip or wire, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve complete all as specified and directed Note: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items.
All as per item No. 15 above but for 16 Sqmm, 4 core XLPE cable.
All as per item No. 15 above but for 50 Sqmm, 3.5 core XLPE cable.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass complete all as specified and directed.
M&L for RCC 1:2:4 type B-1 using 20mm graded stone aggregate as in foundation filling and mass complete all as specified and directed.
M&L for work to sides of concrete foundation, footing base of columns, raft and raft beam side and soffit if any of foundation and plinth beams and similar work, vertical of batter rough finished surface of flat concrete complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per Item No. 21 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
S&F or passing through pipe 1100 Voltage grade heavy duty cable with PVC insulated and sheathed copper conductor comfirming to relevent IS size 1.5 sqmm 3 core unarmoured and connecting to system complete all as specified and directed.
S&F of hot dip galvanized octagonal poles of 06 mtr height top dia 70 mm and bottom dia 130 mm and thickness of sheet 3 mm, in single section designed to withstand the maximum wind speed as per IS 875.The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. Octagonal pole shafts shall be provided with the rigid flange plate of size 200X200X12 mm with provision of hole of 24 mm dia for fixing 4 Nos foundation bolts of size 20 mm dia and 600 mm long. This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside. The octagonal Poles shall have door of approximate 500 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance , weather proof to ensure safety of inside connections and shall be flush with the exterior surface with suitable locking arrangement . Inside of door there shall also be suitable arrangement of connector block for the purpose of connection of cable of size upto 16 Sq mm 4 core , earthing and one No MCB SP 06 Amp including provision for cable entry through and inluding HDPE pipe (from trench to pole) of required size complete all as specified and directed. Make Bajaj ,BOP-6030-HSN Code-73089000 or equivalent model of make specified makes. (Note :- Earth work PCC,RCC ,reinforcement & foundation bolt required will be measured and paid separately in respective items)
M&L foundation bolts of size 20mm dia and 600mm long (4 Nos for each pole) & each having three nuts & washers suitable for fixing of octagonal pole of 7 mtr height, complete all as specified and directed.
S&F single arm bracket 1.5 RM long made with 40mm GI tube light grade with pole mounting pipe with welded top cover & stiffner plate, suitable to fit on octagonal pole with three Nos 10mm dia HDG pinch bolts, complete all as specified and directed.
All as per item No. 26 above but double arm bracket.
S&F roadway luminaire LED light fittings with pressure dia cast aluminium of 72 watts and including necessary electric connection with 2.5 Sqmm twin core copper conductor unarmoured cable, complete all as specified and directed. Make Philips Cat part No BRP062 LED 82/84 CW/ Crompton Cat Part No. NEXUS NEO-LSTP-72-CDL-M/ Bajaj Cat part No. BRTFG 72W LED V3
Supply, fabricate, erect, testing and commissioning LT outdoor feeder pillar box 500x500x200mm totally enclosed weather and vermin proof, suitably ventilated, 440 Volts, 50HZ,AC supply, factory made, fully compartmentalized made out of 3.15 mm thick CRCA sheet for load bearing and 2.00 mm thick non load bearing portions, protection of enclosure IP-54 as per IS-2147 of 1962 complete with pre-treatment with approved colour including suitable angle iron/flat iron frame work/supports, danger notice board, excavation and earth work, PCC foundation etc, out door type, cubical type as required with and including the following, supplied fitted and connected internally and connected to existing earthing complete all as specified and directed. (a) 4 No aluminium busbar of 200 Amp (b) MCCB, 100 Amp, 4 Pole 415 V, 01 Nos (c) LED Indicator lamp (R,Y,B,G)-01 set of 04 Nos
M&L for earthing with Galvanised iron earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal GL) with top of earth plate not less than 1.5 mtr below GL connected to GI strip of size 32x6 mm connected to earth plate electrode by means of GI nuts, bolts, and washers with and incl, PCC 1:3:6 type C-1 pit with cover of RCC 1:2:4 type B-1 reinforced with welded steel wire fabric not less than 4 Kg per Sqm, watering arrangements with 20mm dia GI medium grade pipe, GI funnel with GI mesh, filling with mixture of common salt and charcoal, necessary excavation and earth work in any type soil, including test point, testing and commissioning complete all as specified and directed. Note: GI strip upto 7.5 mtr will be included in quoted rate.
BEHL ENGINEERS AND TRADERS
Saraswati Constructions
M/s Deeksha construction
MAHABIR SINGH
HARI OM CONSTRUCTION
H.B. Traders
PANDEY TRADERS
RVRconstructon
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .