Associate Vice President (HCD)
HLL Lifecare Limited, HLL Bhavan, No26/4, Tambaram-Velachery Main Road, Pallikaranai, Chennai 600 100, Tamilnadu
Setting Up of Virology Laboratory at Sobhan Singh Jeena Govt. Medical Science and Research Almora at Uttarakhand on Turnkey Basis
2023_HLL_171679_1
HLL/CMO/HCD/PS/ALMORA/2023-24
Open Tender
Civil Works - Buildings
Item Rate
60 days
ALMORA
Please refer Tender documents.
23 documents required · 23 mandatory
₹1,770
Yes
Payable To
₹2.9 L
Yes
chennai
3 Apr 2025
20 Oct 2023
15 Nov 2023
20 Oct 2023
14 Nov 2023
20 Oct 2023
25 Oct 2023
Amount
CIVIL WORKS
Scrub Station
Providing and Fixing 2 bay Surgical Scrub Sink made out of 304 Stainless Steel & seamless welded construction polished to a satin finish which is operated on sensors.Overall Size 1600mmL x 622mmW x 718mmH (63"L x 24.5"W x 28.25"H) Sink Size 1525mmL x 508mmW x 356mmH (60"L x 20"W x 14"H) 2Nos of elbow operated water tap and a Soap Dispensor holder. Welding Joints TIG welding with seamless curves Drain and grid Surface. Including the Cost of 35m UPVC IN & OUT Pipes MAKE: . MEDFLOW/BALAJI/ALTOS/MOV MAK
Pass Box
Providing and fixing Pass Box of Chamber dimension 610 mm x 610 mm x 610 mm The unit shall be complete with HEPA filters, blower, motor, door electromagnets, door interlock, UV Lamp with timer, necessary wiring, controls and all other accessories. etc. complete. The Pass Box doors shall be interlocked by providing suitable electromagnet, so that both the door cannot be opened simultaneously. The interlock shall provide visual indicator for door open/close conditions. The blower motor of Pass Box shall of suitable rating and shall be dynamically and statistically balanced. Magnehelic differential pressure gauge shall be provided to indicate the pass box chamber pressure. The pass box shall be provided with UV light with ON/OFF switch and shall be interlocked with the pass box doors
Efluent Decontamination Sysytem
Supplying erection commissioning and testing of Chemical Decontamination System for BSL-3 Laboratory effluent shall comprise of two nos. Effluent Collection tanks for 5KLD (1 Working +1 Standby), each of full required Capacity. The decontamination tanks shall be constructed in SS 304 (14 gauge). The drain line from BSL-3 Laboratory containment area shall be terminated to the effluent decontamination tanks. The effluent decontamination tanks shall be provided with motorized OPEN/CLOSE valves connected with liquid level sensor such that when one tank get filled up to full volume, the supply valve shall automatically close and the supply valve of the standby tank shall automatically open to allow collection of effluent. One number chemical storage tank in SS 304 (14 gauge) fitted with transfer pump and measuring device, piped and connected to both the decontamination tanks shall also be provided for introducing disinfectant chemical into the decontamination tanks. The system shall be complete with items: -Motorized valve connected with liquid level sensor through control panel - Disinfectant Chemical storage tank - Disinfectant Chemical dosing pump - Non return valves - Interconnecting piping including piping for chemical dosing - Pumps for discharging decontaminated effluent into sewer/drain (1W+1S) - Power and control cabling/wiring for pumps and motorized valves with control panel. Including all the works with accessories.
Electrical Works
Point wiring in PVC conduit with modular type switch.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Telephone wiring in existing conduit:
Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
Modular type switch/socket:
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.3 pin 5/6 Amp socket outlet
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.15/16 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.6pin 15/16 Amps (universal) socket outlet
S/F PVC conduit:
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(ISI Make) 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(ISI Make) 25 mm
LAN CABLE
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 run of cable
LAYING OF CABLES
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. FROM EB Mains TO VDB 3.5 X 50 sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. FROM EB Mains FROM VDB TO PBD1,2 3.5 x 25 sq.mm
END TERMINATION
Supply and making end termination with brass compression gland, earth clip and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable fo 1.1KV grade as required. 3.5 X 185 sq.mm
Supply and making end termination with brass compression gland, earth clip and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable fo 1.1KV grade as required. 3.5 X 50 sq.mm
Supply and making end termination with brass compression gland, earth clip and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable fo 1.1KV grade as required. 3.5 x 25 sq.mm
Supply and making end termination with brass compression gland, earth clip and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable fo 1.1KV grade as required. 4 x 16 sq.mm
EARTHING
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc without charcoal/ coke and salt as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
FIRE ALARM SYSTEM-ADDRESSABLE
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required
Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required
PUBLIC ADDRESS SYSTEM
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness
EPABX SYSTEM
Supply, installation, testing and commissioning of EPABX System for upto 2 incoming lines and 8 outgoing lines[including connection for clean room phones] of ISI make complete with its all accessories
Supply and fixing of flush mounted Clean room telehone set for handsfree operation along with its telephone cabling works complete with its all accessories. The phone should have following capabilities 1. smooth front panel sealed with an overlay to keep the phone particulate-free and makes cleaning quick and easy. 2.Auto answer option allows clean room personnel to answer calls without leaving their stations. 3.Oversized buttons allow easy operation for gloved hands. Button function is clearly indicated. 6.Two auto-dial push buttons. 7.on/off push button with keypad for standard telephone operation.
Supply and fixing of Basic landline phone set with jumbo display complete with its all accessories.
FIRE ALARM SYSTEM
Supply, installation, testing and commissioning of 2 loop microprossesor based intelligent and electronically addressable , modular, loop capacity of 159 detectors . Fire alarm control panel with 5.7 inch touch screen LCD display , multiple access levels , 10,000 event history logs in the non volatile memory (EEPROM). The panel should be modular microprocessor based in nature. The panel shall have 240 V AC power supply, automatic battery charger, 24 v , ceiled lead acid maintanance free batteries sufficient for 24 hours normal working and then be capable of operating the system for 30mints during emergency condition. The panel shall be EN 54 /UL certification.
Supply & Fixing ISI marked ( IS : 15683 ) Portable Fire Exitnguisher, ABC type,finished externally with red enamel paint, complete in all respects including initial fill and wall suspension of following capacity.-4 KG
Supply and installation of Co2 Fire Extinguisher (Trolley Mount - Wheel Operating) Type 4.5KG with MS clamps etc. for fixing on wall/wooden partition with 01 year warranty. I.S. No. 13849.
PUBLIC ADDRESS SYSTEM
Mixer amplifier: Supply Installation Testing & Commissioning of Class-D PA Amplifier with USB/SD, FM & Bluetooth with remote controller, RMS power: 35W, Impedence: 4Ω, 8Ω, 16Ω , Speaker output: 100V or 70V, Input: 3x Mic in, 2x Line in
Gooseneck Mic: Supply Installation Testing & Commissioning of 18" Condenser type Gooseneck mic with Frequency response: 30Hz-20kHz, Output impedance: 75Ω, Dynamic range: 109 dB, Signal to noise ratio: 65 dB, On/Off switch
CABLE SUPPLY
Supplying the following PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade as per CPWD standards as required. (Make:Havells/ Glostar/Nicco/Finolex/Polycab) 3.5 x 50 sq.mm
S/F of TP MCB
Supplying and fixing 6 amps to 63 amps rating, 415 Volts, "C" series, miniature cirucuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.(Make: Legrand/Havells/HPL) 63A TP MCB
Supplying and fixing 6 amps to 63 amps rating, 415 Volts, "C" series, miniature cirucuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.(Make: Legrand/Havells/HPL) 40A TP MCB
S/F of TPN RCBO
Supplying and fixing following rating, four pole, (three phase and neutral) 415 volts RCBO, having a sensitivity current upto 100/300 milliamperes in the existing MCB PDB complete with connections, testing and commissioning etc. as required.(Make: Legrand/Havells/HPL) 63 A 4P RCBO 100mA
Supplying and fixing following rating, four pole, (three phase and neutral) 415 volts RCBO, having a sensitivity current upto 100/300 milliamperes in the existing MCB PDB complete with connections, testing and commissioning etc. as required.(Make: Legrand/Havells/HPL) 63 A 4P RCBO 100mA. 40 A 4P RCBO 30mA
EARTHING WIRE
Supplying and laying 10 SWG Copper wire on, surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/ cable as required.
SIGN BOARDS
Provide and Fixing of L.T./H.T danger sign boards
PLC CONTROL SYSTEM
Fabricate, testing, supply and commissioning of Programmable logic control based control system for real time centrallized control & monitoring with all accessories, auxilliaries and associated equipments and cables for safe , efficient and reliable operation. The Control system shall include on-line self-surveillance, monitoring and diagnostic facility giving the details of the fault on the Human Machine Interface System (HMIS) viz. main & standby power supplies, sensor fault, Input/ Output card failure, Memory Status, Controller fault, failure of Communication/ Network links to PLCs, LAN. These faults shall be reported as colour change on system status display and as messages on HMIS as well as through local indication on the faulty module and on respective rack/ cubicle. The diagnostic system shall ensure that the faults are detected before any significant change in any controller output has taken place. PLC basaed system should includes: PLC modules(As per Annexure-1)
Fabricate, testing, supply and commissioning of Programmable logic control based control system for real time centrallized control & monitoring with all accessories, auxilliaries and associated equipments and cables for safe , efficient and reliable operation. The Control system shall include on-line self-surveillance, monitoring and diagnostic facility giving the details of the fault on the Human Machine Interface System (HMIS) viz. main & standby power supplies, sensor fault, Input/ Output card failure, Memory Status, Controller fault, failure of Communication/ Network links to PLCs, LAN. These faults shall be reported as colour change on system status display and as messages on HMIS as well as through local indication on the faulty module and on respective rack/ cubicle. The diagnostic system shall ensure that the faults are detected before any significant change in any controller output has taken place. PLC basaed system should includes: PLC modules.(As per Annexure-2)
Fabricate, testing, supply and commissioning of Programmable logic control based control system for real time centrallized control & monitoring with all accessories, auxilliaries and associated equipments and cables for safe , efficient and reliable operation. The Control system shall include on-line self-surveillance, monitoring and diagnostic facility giving the details of the fault on the Human Machine Interface System (HMIS) viz. main & standby power supplies, sensor fault, Input/ Output card failure, Memory Status, Controller fault, failure of Communication/ Network links to PLCs, LAN. These faults shall be reported as colour change on system status display and as messages on HMIS as well as through local indication on the faulty module and on respective rack/ cubicle. The diagnostic system shall ensure that the faults are detected before any significant change in any controller output has taken place. PLC basaed system should includes: Door access system (As per Annexure-4)
Fabricate, testing, supply and commissioning of Programmable logic control based control system for real time centrallized control & monitoring with all accessories, auxilliaries and associated equipments and cables for safe , efficient and reliable operation. The Control system shall include on-line self-surveillance, monitoring and diagnostic facility giving the details of the fault on the Human Machine Interface System (HMIS) viz. main & standby power supplies, sensor fault, Input/ Output card failure, Memory Status, Controller fault, failure of Communication/ Network links to PLCs, LAN. These faults shall be reported as colour change on system status display and as messages on HMIS as well as through local indication on the faulty module and on respective rack/ cubicle. The diagnostic system shall ensure that the faults are detected before any significant change in any controller output has taken place. PLC basaed system should includes: Control panel (As per Annexure-3)
Fabricate, testing, supply and commissioning of Programmable logic control based control system for real time centrallized control & monitoring with all accessories, auxilliaries and associated equipments and cables for safe , efficient and reliable operation. The Control system shall include on-line self-surveillance, monitoring and diagnostic facility giving the details of the fault on the Human Machine Interface System (HMIS) viz. main & standby power supplies, sensor fault, Input/ Output card failure, Memory Status, Controller fault, failure of Communication/ Network links to PLCs, LAN. These faults shall be reported as colour change on system status display and as messages on HMIS as well as through local indication on the faulty module and on respective rack/ cubicle. The diagnostic system shall ensure that the faults are detected before any significant change in any controller output has taken place. PLC basaed system should includes: CCTV System.(As per Annexure-5)
Fabricate, testing, supply and commissioning of Programmable logic control based control system for real time centrallized control & monitoring with all accessories, auxilliaries and associated equipments and cables for safe , efficient and reliable operation. The Control system shall include on-line self-surveillance, monitoring and diagnostic facility giving the details of the fault on the Human Machine Interface System (HMIS) viz. main & standby power supplies, sensor fault, Input/ Output card failure, Memory Status, Controller fault, failure of Communication/ Network links to PLCs, LAN. These faults shall be reported as colour change on system status display and as messages on HMIS as well as through local indication on the faulty module and on respective rack/ cubicle. The diagnostic system shall ensure that the faults are detected before any significant change in any controller output has taken place. PLC basaed system should includes: Computer (As per Annexure-6)
BAG-IN-BAG-OUT
Supply, installation, testing and commissioning of Bag in Bag out[BIBO] unit complete with its all accessories. The unit should have the following specification listed as per annexure 8.
DUCTABLE TYPE SPLIT AIR CONDITIONER
SITC of DX type double skinned air handling units, ceiling suspended/ floor mounting type 11TR, 750lps capacity complete with suitable DIDW blower (as per approved make), blower section, static presure of 150 mm of water column, built in pre filter, fine filter & hepa filter 99.97% effieciency down to 0.3 microns and controls connected to condensing units, insulated SS drain pan 6 row cooling coil, electric motor , direct driven package with TEFC motor class B insulation, suitable for 3 phase, 415V 50Hz supply, suitable AHU panel & cabling. AHU temp & speed control panel, ARI certified, with 0.70 mm sheet for outer skin and plain GP 0.63 mm sheet for inner skin 47mm thick PUF panel, belt guards, suitable supports for suspending from slab, vibration isolator, strip heater etc. conforming to specifications. Refer Annexure 9: 8.5 Tr (3600 cfm) with 3 stage Filteration
Supply, installation, testing and commissioning (SITC) of 8.5 TR capacity aircooled inveter type Outdoor condensing unit with single/multi scroll compressor as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll compressor, electronic microprocessor pendant controller with digital display, first charge R 407A/R410A refrigerant gas, vibration isolator pads and saftey devices like thermal protector, pressure relief valve, over load relays single phase preventor, high-low pressure cut out, suitable for three phase 440V supply.
Supply, installation, testing and commissioning of suitable sized hard drawn copper refrigerant piping(both suction and liquid piping) including 25mm thick dosed cell elastomeric insulation as per specification for 11 TR machine between indoor & outdoor units as per site conditions complete in all respect.
Canvass connection out of synthetic SRF cloth with zip fastener for measuring temperature at the outlet of AHU.
Supply, installation and testing of Exhaust fan/blowers with hepa filtered for uni directional air circulation-As per Annexure 11) Exhaust Fan location for BSL-3 : Minimum 25 ft from AHU intake Air velocity at exhaust discharge : 15-20 m/s (3000-4000 fpm) for BSL-3
FILTERATION FOR ICU STANDARDS
Supply, installation, testing and balancing of Powder coated/Anodised extruded aluminium construction, inlet air louvers with bird screen, volume damper & filter for fresh air as per specifications and approved drawings.
FILTERS: F-7 Filter & Discharge supply section ,Flanged type F-7( 3 micron) Fine filter Flanged type G-4 Pre-filters of capacity-1 no spare.
Lowside Ancillary Works-Part C
Supply, installation, balancing and commissioning of ISI-655 site fabricated make 22 swg 19mm insulation of class O, aluminium sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications.
Supply, installation, testing and commissioning of centrifugal stainless steel air curtain with remote and sensor with high quality international standards - CE GS Approved Casing made in Stainless Steel body which is sealed to resist dust going inside, with fire and corrosion resistance, and easy for cleaning and maintenance. Blowers are made of high quality ABS to ensure less noise with toughness intensified High quality motor, low noise, overload protection, and long life-span. Air speed is with High and Low two switch of speeds
DUCT INSULATION / ACOUSTIC INSULATION
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19mm
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 25mm
Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.
AIR TERMINAL DEVICES
Supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications, 200mm dia
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Fire Damper
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Actuator
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room. Damper
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room. Actuator
Supply & fixing of powder coated extruded aluminium SUPPLY AIR DIFFUSER with aluminium volume control dampers as per specification with anti smudge ring & removable core.
Supply & fixing of powder coated extruded aluminium RETURN AIR DIFFUSER with louvers without volume control dampers as per specification anti smudge ring & removable core.
LT CABLES
Supplying the following PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade as per CPWD standards as required. (Make:Havells/ Glostar/Nicco/Finolex/Polycab) 3.5 x 35 sq.mm
Laying of the following PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade as per CPWD standards as required. (Make:Havells/ Glostar/Nicco/Finolex/Polycab) 3.5 x 35 sq.mm
Supplying the following PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade as per CPWD standards as required. (Make:Havells/ Glostar/Nicco/Finolex/Polycab) 3.5 x 25 sq.mm
Description of Work / Item(s)
Amount
Equipments
Antibiotic Zone Scale
Cross Over Bench (Stainless Steel)
Elisa Reader and Washer
Freezer -20C
Freezer -70C
Incubator
Inverted Light Microscope
Laminar Air flow Cabinet
Liquid nitrogen containers
Microwave Oven
Mini Centrifuge
PCR Workstation
pH Detern'rination apparatus (pH meter with digital display)
Pipette Sterilization Can
Refrigerated Centrifuge for Virology
Refrigerated centrifuge PCR
Ultrapure Water Purifier
UV Lamp
Description of Work / Item(s)
Amount
Elisa Reader and Washer
2nd Year
3rd Year
4th Year
5th Year
6th Year
Freezer -20C
2nd Year
3rd Year
4th Year
5th Year
6th Year
Freezer -70C
2nd Year
3rd Year
4th Year
5th Year
6th Year
Inverted Light Microscope
2nd Year
3rd Year
4th Year
5th Year
6th Year
Laminar Air flow Cabinet
2nd Year
3rd Year
4th Year
5th Year
6th Year
PCR Workstation
2nd Year
3rd Year
4th Year
5th Year
6th Year
Refrigerated Centrifuge for Virology
2nd Year
3rd Year
4th Year
5th Year
6th Year
Refrigerated centrifuge PCR
2nd Year
3rd Year
4th Year
5th Year
6th Year
Ultrapure Water Purifier
2nd Year
3rd Year
4th Year
5th Year
6th Year
6th Year
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .