| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹39.1 L+₹2.7 L (7.46%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹39.4 L+₹3.0 L (8.15%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹40.1 L+₹3.7 L (10.0%)Rejected-Finance LANE NO 2 HOUSE NO 3 COL KEHAR SINGH COLONY KHUSROPUR JALANDHAR CANTT JALANDHAR PUNJAB 144005 | JALANDHAR | PUNJAB | 144005 | L4 | Rejected-Finance L4 | |
| 5 | L5₹40.1 L+₹3.7 L (10.1%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹40.8 L
EMD Value
₹81,580
Closing Date
8 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
SPL REPAIRS TO BLDG NO. T-64 (OFFRS MESS) OF 4011 FD HOSP AND CERTAIN OTHER SANCTIONED WORK UNDER GE (EAST) JALANDHAR CANTT
2024_MES_646515_1
GE/JULL/ET-76/2023-24
Open Tender
Civil Works
Item Rate
183 days
Jalandhar Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹81,580
Yes
31 May 2024
26 Mar 2024
16 May 2024
26 Mar 2024
8 May 2024
26 Apr 2024
Amount
Dismantling wall and ceiling boards’ fibre, pulp, insulations etc or insulation boards/slabs/blankets any thickness incl cover fillets complete all as specified and as directed.
Supply and fixing 6mm thick non asbestos fibre cement building boards one side laminated in ceiling fixed with as per manufacturers instructions purpose, 60 X 60 cm size fixed with powder coated Gl frame work for ceiling comprising of Gl perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre. including necessary GI wire hangers 2mm dia for securing frame work to ceiling, and also including necessary notching complete all as specified and directed
Material and labour for PVC Lining consisting of 5mm thick hollow profile coloured decorative PVC sheet inclusive of solvent cement and fixing on ceiling to make frame as and fixing at site on PVC frame as per manufacturer instruction.
Dismantling floor hearth or wall tiling/china mosaic including cement mortar bedding (but not backing), rubbish off the premises complete all as specified and directed
Material and labour for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed
Material and labour for 20 to 25mm thick machine cut Kota stone in flooring laid over and including 15mm thick screed in cement mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the colour of stone slab including rubbing and polishing complete all as specified and directed
Material and labour for glazed ceramic coloured tiles (premium quality) in vertical surface such as skirting/ dado etc of size 450x300x7mm thick set and jointed in cement slurry and pointed in white or colour cement to match the tiles over and including 10mm thick plaster in CM 1:4 to receive the tiles complete all as specified and directed
Material and labour for vitrified ceramic tiles light shed 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick cement screed bedding layer in cement mortar 1:6 complete all as specified and directed
Material and labour vitrified ceramic tiles 10mm thick, any shade as approved, polished area of each tiles n. exc. 0.36 Sqm (square/ rectangular) in vertical surfaces such as skirting/ dado, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including rendering 10mm thick in cement mortar (1:4) complete all as specified and directed.
Excavating in trenches, n exc 1.5m wide and n.exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 Sqm on plan and n.exc 1.5m in depth and getting out soft/ loose soil complete all as specified
Material and labour for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling/mass concrete complete all as specified
Material and labour for reinforcement cement concrete 1:1.5:3 type A-1 nominal mix (using 20mm graded stone aggregates) as in foundations, including raft footing, foundation beams, for columns etc, basement slabs and mass concrete complete all as specified and directed
Material and labour for reinforcement cement concrete 1:1.5:3 type A-1 nominal mix (using 12.5mm graded stone aggregates) as in columns, pillars, piers, posts and struts complete all as specified and directed
Material and labour reinforcement cement concrete 1:1.5:3 type A-1 nominal mix (using 12.5mm graded stone aggregates)Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and complete all as specified and directed
Material and labour for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified
All as per Srl item No 15.00 here-in-before but TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders all as specified
Use and waste form work to sides of concrete foundations, footings, bases of columns and similar works rough finished flat surfaces of concrete all as specified.
Use and waste form work to sides of pillars, posts, columns and similar works rough finished square, rectangular or polygonal surfaces of concrete all as specified.
Use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick works rough finished surfaces of concrete all as specified
Removal of excavated material upto exc. 250m but n.exc 500m and deposited where directed
Returning filling in including spreading levelling watering & well ramming in layers n.exc 25 cm in soft/ loose soil complete all as specified.
Material and labour for providing cement concrete type B-1, 1:2:4 using 20mm graded stone aggregates as coping and like including weathering, slightly rounded or chamfered angles and throating as directed.
Dismantling of asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings complete all as specified
Supply and fixing pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws complete all as specified
Supply and fixing pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws complete all as specified
Supply and fixing 3mm thick Aluminium composite panel cladding of approved quality and colour as approved by GE, fixing in aluminium frame work and filling the joint with all weather silicon sealant including all mouldings, cuttings, etc complete all as specified and directed
Dismantling cast iron work of any description complete all as specified
Material and labour for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified
Material and labour for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1998 complete all as specified
Taking down cement plaster on brick/ stone masonary including raking out joints, hacking for scrubbing down with water etc. complete all as specified and as directed.
Material and labour for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified
Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-Charge
Supply and fixing hollow PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet and fixing at site including fillets as per manufacturing instruction complete all as specified
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed..
Material and labour for brick work with fly ash brick, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified
Material and labour for 15mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all specified and directed.
Material and labour for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion over a coat of primer complete all as specified
Material and labour for preparation of old decorated/treated surface of walls including removing existing treatment by rubbing, scrapping, washing and applying two coats of oil emulsion including 3mm thick wall care putty on wall complete all as specified
Taking down chowkhats or frames with shutter (without taking off shutters form the frames) area not exc 1.5 sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutter (without taking off shutters form the frames) area exc 1.5 sqm but not exc 4.0 sqm each complete all as specified and directed.
Taking down only shutters area exc 1.00 sqm but not exc 2.0 sqm each and complete all as specified and directed.
Taking down only shutters area exc 1.5 sqm but not exc 4.0 sqm each and complete all as specified and directed.
Refixing of shutters of any description exc 1.00 and n exc 2 Sqm each in same opening complete all as specified and directed.
Refixing of shutters of any description exc 2 Sqm each in same opening complete all as specified and directed.
Supply and fixing 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply and fixing 3 mm thick sheet glass ordinary quality and glazing with oil putty in square exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply and fixing 5.5 mm thick sheet glass ordinary quality and glazing with oil putty in square exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply and fixing stainless steel wire cloth 0.48 mm nominal dia and average width of aperture 1.40 mm fixed with tinned tacks or galvanised wire staples complete all as specified and as directed.
Supply and fixing solid PVC door frame of size 50mmx47mm made out of 5mm plain, colour PVC sheet reinforced with MS square tube, supplying and fixing opening as per specification and drawing
Supply and fixing Factory made solid panel PVC door shutters 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the M.S frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site, complete all as specified, shown on drawing and as directed .
Supply and fixing Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing Fe 410-W (Gde-E-250) complete all as specified and directed.
Supply and fixing 100 mm but hinges extruded aluminium alloy with mild steel hinge pin anodized and fixed complete all as specified
Supply and fixing aluminium anodised barrel tower bolt 125 mm long of extruded section complete all as specified
Supply and fixing aluminium anodised barrel tower bolt 100mm long of extruded section complete all as specified
Supply and fixing aluminium anodised handle cast type 125 mm, anodised complete all as specified
Supply and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge
Supply and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Chief.
Supply and fixing Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring overall length of cover plate 75mm complete all as specified and directed.
Supply and fixing cast iron door closer hydraulically regulated designation No 3 universal type suitable for door shutter of width between 851 to 1000mm having weight between 61 kg to 80 kg and fixed, complete all as specified and directed.
Material and labour for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint with primer red oxide complete all as specified and directed
Material and labour for preparation of old steel surfaces of any description over 10cm width or girth and applying one coat to old surfaces incl preparation of surfaces complete all as specified and as directed
Supply and fixing stainless steel, 25mm dia heavy duty superior quality curtain rod with brackets, stops, rollers etc as approved by GE complete all as specified and directed.
Taking down old GI tubing and connection including fittings 15mm bore pipe complete all as specified and as directed.
Taking down old GI tubing and connection including fittings 20mm bore pipe complete all as specified and as directed.
Supply and fixing 15mm bore galvanized iron tubing medium grade with all fittings, fixed to walls, ceiling or laid in floors, complete all as specified and directed.
Supplying and laying 20mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified
Supply and fixing 20mm bore galvanized iron tubing medium grade with all fittings, fixed to walls, ceiling or laid in floors, complete all as specified and directed.
Supply and fixing in repairs Stop valve / Angle valve fancy type cast copper alloy chromium plated screwed down high pressure with capstan heads screwed both ends for iron pipe or for union and fixed 15mm bore complete all as specified and directed
Supply and fixing in repairs Stop valve cast copper alloy chromium plated with long shank and cup (concealed type) screwed down high pressure with capstan headed screwed both ends for iron pipe or for union and fixed 15mm bore complete all as specified and directed.
Supply and fixing in repairs 15mm bore bib tap cast copper alloy, chromium plated, long body fancy type with capstan headed, screwed down, screwed for iron pipe complete all as specified and directed
Supply and fixing in repairs WHB mixer chromium plated brass, size 15mm bore screwed down high pressure with lettered Hot and Cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed
Supply and fixing in repairs Vitreous China wash down water closet white with concealed S-Trap/P-trap, 360mm wide, 390mm high and 415 to 445mm long at top including fixing bolt Plastic water closet seat cover white closed pattern with flat bottom and cover and mild steel chromium plated hinging device fixed complete all as specified and directed
Supply and fixing in repairs PVC 10 litre syphonic action type flushing cistern, low level with inlet, ball valve, float and handle (ISI Marked) including brackets, flush pipe PVC 32mm bore and connection to WC complete all as specified and directed
Supply and fixing PVC connection 450mm long suitable for 15mm bore pipe including PTMT nuts complete all as specified and directed
Supply and fixing in repairs Vitreous China Wash hand basin white, angle back size 600 x 450 mm size including pedestal all as specified and directed
Supply and fixing in repairs Chromium plated brass shower rose, swivel type of size 150mm x150mm fixed to pipe complete all as specified and directed
Supply and fixing in repairs Chromium plated grating 125mm dia circular of approved make and fixing with cement mortar 1:3 on Nahani trap or floor trap complete all as specified and directed
Supply and fixing marble for shelves for soaps etc embeded in wall with cement mortar and making good complete all as specified and directed.
Supply and fixing soap dish, vitreous china white approx size 160mm x 160mm x 90mm complete all as specified and directed
Supply and fixing brass chromium plated tubular 20 mm dia D type towel rail 600mm long complete all as specified and directed.
Material and labour for cutting holes in brick walls, built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1as required in exc. half brick but not exc. one brick thick walls, complete all as specified and as directed
Dismantling water tanks exc 250 ltr but not exc 500 ltr capacity removing to store complete all as specified and as directed
Dismantling water tanks exc 500 ltr but not exc 1000 ltr capacity removing to store complete all as specified and as directed
Supply and fixing Rotational moulded polyethylene water storage tanks 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed
Supply and fixing Rotational moulded polyethylene water storage tanks 2000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed
Material and labour for pre-cast reinforced cement concrete 1:2:4 (20mm graded aggregate) in cover slab of manholes, septic tanks, etc., set in cement mortar 1:4 including necessary forms, moulds, etc., complete all as specified and as directed. Note : Reinforcement will be Measured and Paid separately under appropriate Items
Supply and fixing cast iron floor trap diameter of outlet 75mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4 (20mm graded aggregate) and fixed-in-repairs, complete all as specified and as directed
Supply and fixing cast iron nahani trap diameter of outlet 75mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4 (20mm graded aggregate) and fixed-in-repairs, complete all as specified and as directed.
Supply and fixing in repair PVC (SWR) pipe 75mm bore (dia), single socketed, in any length with Rubber Ring Joints fixing to floor/Walls etc, including clamp/hook for holding of pipe, complete all as specified and as directed.
Supply and fixing in repair PVC (SWR) pipe 110mm bore (dia), single socketed, in any length with Rubber Ring Joints fixing to floor/Walls etc, including clamp/hook for holding of pipe, complete all as specified and as directed.
Supply and fixing PVC (SWR) 75mm bore (dia) Bend any type, provided with Access Door, etc. and Jointing with Solvent Cement and fixed-in-repairs, complete all as specified and as directed.
Supply and fixing PVC (SWR) 110mm bore (dia) Bend any type, provided with Access Door, etc. and Jointing with Solvent Cement and fixed-in-repairs, complete all as specified and as directed.
Demolition/Breaking up Drain Pipes (SGSW) 150mm bore (dia), Jointed in Cement Mortar of any description including PCC of Packing and Haunching to Sides of the Pipes (except Bed), complete all as specified and as directed.
Demolition/Breaking up Drain Pipes (RCC) 200mm bore (dia), Jointed in Cement Mortar of any description including PCC of Packing and Haunching to Sides of the Pipes (except Bed), complete all as specified and as directed.
Material and labour for concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C2 for bore 150mm dia complete all as specified
Material and labour for concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C2 for bore 200mm dia complete all as specified
Material and labour reinforced concrete drain pipe 150mm bore (dia), class NP2, laid in trenches, jointed complete with collars and in cement mortar 1:1 and testing, complete all as specified and as directed
Material and labour for reinforced concrete drain pipe 200mm bore (dia), class NP2, laid in trenches, jointed complete with collars complete all as specified and as directed.
Material and labour for wire brushing and cleaning top surface of cement concrete, including flashing and junction of parapets etc complete all as specified
Material and labour for brushing neat cement slurry with 3 kg of cement per sqm complete all as specified and as directed
Material and labour for cement concrete in foundations, filling and mass concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in roof padding 50mm thick in average complete all as specified and directed
Material and labour for 12mm thick cement plaster in cement mortar (1:3) on concrete roof surfaces finished even and fair, including cleaning the roof top by water etc all as specified and directed
Supply and applying high built elastomeric waterproofing coating based on pure hydrophobic polyurethane cold applied of spray/brush applied, membrane with an elongation of 280% and tensile strength of 2.7 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm, no leakage upto 5 bars of water pressure as per DIN 1048, min 88% solid content. The system includes final base preparation, epoxy primer 1: (resin; harder) application with 100% water dilution and pure polyurethane application in 2 coats with a tortal min consumption of 1.25 kg per Sqm. Application should be done with Graco sprauer by a company authorised applicator complete all as specified and directed
Supply and fixing powder coating aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
Supply and fixing in repairs 3mm thick ACP wall panel plain colour PVC sheet fixed in bottom portion of aluminium door shutter complete all as specified and directed
Supply and fixing aluminium mortice lock, vertical type size 65mm 4 lever brass body complete all as specified and directed.
Supply and fixing in repairs Door closer hydraulically of aluminium extruded section body regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified.
Excavating in post holes (or similar holes) each n.exc 0.5 cum getting out in any type of soil returning, filling in and ramming earth in layers n.exc 25cm, watering and removing surplus soil to a distance n.exc 50m and making good surfaces complete all as specified and directed.
Material and labour for mild steel plates plain, square cut welding to base of hollow pipes etc complete all as specified and directed
Supply and fixing collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed
Material and labour for framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, framed guard bars, barred iron doors, ladders, framed balusters, walk ways railings and similar work conforming to Fe-290, Gde-E-165, complete all as specified and directed
Taking down carefully existing point wiring of any type/ any size (i.e. on wooden/ batten, surface conduit, casing capping or concealed conduit) complete for light, fan, socket or power point etc including removing switches, sockets, holders, ceiling rose, pendants, regulators, light fittings, switch board outlets with sheets and other materials from site for refixing of serviceable light, accessories for taking credit of unserviceable light and accessories as per Sch of credit and making good disturbed surface of walls, roof, floors etc. with any type of civil work involved complete all as specified and directed
Material and labour for point wiring for light/fan point with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm cable drawn in and including concealed rigid PVC conduit medium grade not less than 20mm dia with accessories including cutting chases for laying of conduit /fixing of boxes in walls/floor etc including making good to disturbed surfaces as per adjoining specification and terminated in and incl sunken pressed steel boxes duly painted with anti corrosive paint over a coat of red oxide primer with plastic laminated bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with cup washers etc including FRLS PVC insulated unsheathed multi stranded copper conductor 1.5 Sqmm single core as earth continuity conductor (green colour) connected with earth dolly with thimble complete all as specified and as directed by Engr-in-Charge.
All as per srl item No. 115.00 here-in-before but for one socket outlet 5 Amps on independent board complete all as specified
All as per srl item No. 115.00 here-in-before but for one socket outlet 5 Amps on the same board controlled complete all as specified
All as per srl item No. 115.00 here-in-before but with 2.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multistranded copper conductor cable for one 3 Pin 15 Amp socket on independent board including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and directed by Engineer-in-Charge
Supply and fixing switch piano flush type, 6 Amps, 240 Volt AC single pole, one way complete all as specified.
Supply and fixing switch piano flush type, 16 Amps, 240 Volt AC single pole, one way complete all as specified.
Supply and fixing socket out let 6 Amp, 5 pin, 2-in-1 flush type complete all as specified.
Supply and fixing socket outlet multi purpose 2 in 1, 5/6 pin, 6 & 16 Amps, flush type complete all as specified.
Supply and fixing ceiling rose surface type PVC/ polycarbonate 65mm x 50mm three terminal complete all as specified.
Material and labour for sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 6.0 Sqmm drawn through in and including new PVC rigid non metallic concealed conduit (medium grade) with all fittings including earth continuity single wire FRLS PVC insulated unsheathed multistranded copper conductor cable 6.0 Sqmm ( green insulation) with any type of civil work including making good to disturbed surfaces to match existing surface complete all as specified. NOTE: Two run of 6.0 sqmm wire and one run of 6.0 sqmm wire as earth wire including PVC conduit shall be measured as one unit.
Material and labour for sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 2.5 Sqmm drawn through in and including new PVC rigid non metallic concealed conduit (medium grade) with all fittings including earth continuity single wire FRLS PVC insulated unsheathed multistranded copper conductor cable 2.5 Sqmm ( green insulation) with any type of civil work including making good to disturbed surfaces to match existing surface complete all as specified. NOTE: Two run of 2.5 sqmm wire and one run of 2.5 sqmm wire as earth wire including PVC conduit shall be measured as one unit.
Supply & fixing MCB SP 6 to 32 Amps 240 V, 10 KA, B curve as per Osafe series of HPL/ Acti 9 series of Schneider/ Optipro of Indoasian or equivalent in Havells/ Legrend/ ABB/ Siemens/ Hager. complete all as specified and directed by Engineer-in-Charge
Supply and fixing MCB SPN 40 Amps 240 V, 10 KA, B curve as per Osafe series of HPL/ Acti 9 series of Schneider/ Optipro of Indoasian or equivalent in Havells/ Legrend/ ABB/ Siemens/ Hager. complete all as specified and directed by Engineer-in-Charge
Supply and fixing LED lights fitting 1x 20 Watt, 220V AC decorative box type frame with holder including LED tube rod 20 watt connecting up single/ double connections with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
Supply and fixing LED light fitting mirror type with high out put diffuser 9/10 watt 220 V AC decorative type including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed
Fixing only serviceable tube light fittings any type and any description retrieved under item Srl No. 114.00, including necessary electric connection with round flexible wire with multi stranded copper conductor of size 0.50 sqmm, 3 core, 1100 volts grade complete all as directed.
Supply and fixing five step fan regulator, electronic type, single phase, including connection complete all as specified.
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 16 amp 240 V 10 KA complete all as specified and as directed
Material and labour in replacement for sheet metal DB for MCBs, SPN, 8 ways 240 v, double door, single phase, with copper bus bar, neutral bar/ connectors/ earth link suitable copper thimbles, lugs etc complete all as specified. Make: EKINOX3 series of Legrand/Acti 9 metalic series of Schneider/Optipro of Indoasian/Osafe of HPL/Metallica of Havells or equivalent in ABB/ Siemens/ Hager.
Supply and fixing energy saving & environmental friendly long life versatile pressure die-cast aluminium housing luminaire with heat resistant glass and suitable optics for uniform distribution of light 35 watt LED bldg security lights with high efficiency electronic driver BIS approved, having IP-66 protection, surge protection operative on AC supply 140 volts to 270 volts pre-wired complete with GI pipe of 25mm bore of suitable length and MS clamp duly painted with two coat aluminium oxide paint all as specified and directed
Earthing complete in replacement with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick burried directly in ground (earth pit not less than 2.25 meters deep below normal ground level with the top edge of electrode not less than 1.5 meters below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and incl GI lead protection pipe of GI light grade 15mm dia upto 7.5 mtrs and watering pipe 20mm bore of GI medium grade with funnel and wiremesh, earth plate covered on all sides with min 150mm thick alternate layers of charcoal, salt all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing point with PCC chamber and RCC cover in 1:2:4 complete with any type of earth work involved all as specified and directed and testing on completion. Note:- PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground vertically at a depth not less than 2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI strip 32mm x 6mm upto test point (of GI strip) and of Aluminium strip of 25x3.15mm from test point to equipment with & including GI pipe 40mm bore light grade as protection pipe (upto the body of equipment max 7.50 metre) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of coal dust and common salt 15cm thick, all around top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh complete all as shown in Electrical plate No. 3 of SSR Part-I (2009), testing on completion including PCC chamber (1:3:6) using 20mm graded stone aggregate with MS angle frame of size 25x25x3mm and RCC M-25 cover with MS iron handle of 8mm complete all as specified. Note 1. The cost of GI strip/ wire from top of earth plate upto 7.50 metre above GL with GI protection pipe shall be deemed to be included in unit rate. 2. PCC pit shall be provided at least 0.50 metres away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction elbow etc shall be deemed to be included in the unit rate. 3. In case the testing result of earthing work not found satisfactory, the contractor shall have to carry out earthwork at new location and nothing extra shall be admissible on this account. 4. The earthing work shall be carried out in presence of MES representative detailed by Engineer-in-Charge
Supply and fixing in repair MCCBs 100 Amp 4 pole 415 V, fixing type with breaking capacity 16 KA complete all as specified and directed.
Supply and fixing in repair VTPN DB 4 way double door, suitable for MCCB 100 Amp, having copper bus bar for neutral and earth, blanking strips complete all as specified and directed.
Supply, installation, commissioning and testing of Diesel Engine driven generator set (silent type) with sound proof, weather proof acoustic enclosure confirming to CPCB-IV+ norms with AMF panel, 20 KVA capacity at NTP as available/manufactured or next higher capacity available 415 volts (AC 3 phase,4 wire system of supply) 50 Hz at 0.8 power factor directly coupled alternator & engine, water cooled, common base platform with inbuilt fuel tank, anti-vibration pads including standard control panel other accessories as per manufacturer's design, suitable RCC/PCC platform with foundation as per OEM recommendation and comprising of the following:- (A)ENGINE (Prime mover) : Diesel engine 1500 RPM of suitable BHP as per manufacturer recommendation, natural aspirated, water cooled,12 volts electric battery start, complete with fly wheel and all standard fittings/ fixtures as per manufacturer recommendations including suitable engine control panel with microprocessor controller, battery charger, auto/ manual oeration switch, remote monitoring system and display to show RPM, voltage L-L, L-N, battery voltage, engine speed, phase current and total VA, frequency, fuel level, DG running hrs, KWH generated, lubrication oil pressure, engine temp. including safety automatic shutdown in case of fault such as high water temperature, low oil pressure, over speed, DC over/under voltage etc including self-starter, alternator, cogged V belt, fuel tank, first fill of lub oil and coolant (as applicable) etc complete all as specified.
(B) ALTERNATOR: Alternator AC ,3 phase 415 volts 4 wire rated line current for output 20KVA, PF 0.8, 1500 RPM, 'H' class insulation, enclosure Screen Protected & Drip Proof, self-excited, self-regulated brushless, complete with AVR with ±1% voltage regulation directly coupled with above engine. The alternator shall have permissible overload of 10% for one hour in 12 hrs of operation. (C) Anti vibration pads for mounting engine and alternator assembly on the base frame/plate or as recommended/ provided by the manufacturer (D) Base Plate made out of structural steel as per manufacturer's recommended design/specifications. (E) ACOUSTIC ENCLOSURE Provision of an integral type CPCB IV+ approved/certified acoustic enclosure (sound & weather proof). It shall be made of 16 SWG or as per manufacturer's standard norms made out of CRCA sheet with powder coated finish on outside and provided with foam/rockwool or other suitable acoustic material of suitable thickness and perforated sheet of stainless steel as per manufacturer design to maintain noise level within 75dBA at a distance of 1 mtr. The doors and glass window shall be as per manufacturer's design for easy monitoring of parameters on display. The base frame shall be of ISMC. It shall also include the following:- (i) Silencer : Specially designed low noise silencer. (ii) Internal wiring with PVC copper cable (ISI 694marked) FRLS in conduit and for light and lamp fittings including lamp.
(iii) Fuel tank of suitable capacity as per OEM recommendation with fuel lid having lock facility. (iv) 12V x 180AH maintenance free battery 1 No or as recommended by manufacturer. (F) AMF Panel : The AMF control panel enclosure should be powder coated and weather proof having suitable contactor 4 pole-02 Nos and switchgear to control main supply, DG supply with suitable over voltage/ under voltage/ single phase protection and required CT’s as per OEM recommendations. The DG controller shall have suitable control wring and MCCB to control the output of DG set. Note : (1) Operation and maintenance manual, spare parts list shall also be supplied within overall cost quoted. (2) PCC/RCC platform as per OEM recommendation for mounting of DG set shall be done as per manufacturer design within overall cost quoted. (3) Pre-commissioning test with strip heaters/ heater load as per PS clause shall be carried out by representative of Accepting officer/ IEM and cost of testing, FOL, lubricants and any T&P required etc is deemed to be included in unit rate quoted till the satisfactory results are achieved. (4) POL/Fuel, lub oil or any other spare required for testing shall be arranged by the contractor without any extra cost to the Deptt.
Supply, laying, jointing and testing XLPE insulated, PVC sheathed, GI strip or wire armoured ,heavy duty electric cable with stranded aluminium conductor 1100 Volts grade of cross sectional area 35 sqmm 3.5 core laid in trenches/ducts/through pipes /in floor or road/ along the pole etc complete all as specified and directed
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge
Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified. Note : Punned thickness of 18 cm shall be considered for payment
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-Charge
Supply, install, testing and commissioning of Feeder pillar, outdoor cubicle type weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed, compartment type, suitable to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear hinged (bottle type) openable shutters with locking arrangement with frame made out of angle iron of size 50mm x 50 mm x 6mm, having inner hinged shutters on all independent compartments for switch gears, metering units and bus bar, bottom gland plate for each incoming & outgoing cable of suitable size as per cable's size having openable apron on 3 sides of panel from base to ground level, prewired complete with suitable copper strip/bar etc duly powder coated with 7 tank process having legs made out of angle iron 0.7 mtr long of size 50mm x50mm x 6mm duly grouted in 30 cm in PCC (1:3:6) type C-1 including brick masonary platform all as directed by Engineer-in-Charge comprising with following complete. Note: On panel front and rear side should be properly mentioned with red enamel paint of proper size of word which should be clearly visible from 30 mtr distance :- (a) Bus bar made of copper suitable for capacity 100 Amps with coloured insulated sleeves in four colours (Red, Yellow, blue and black) fixed on porcelain/ DMC insulators with necessary GI nuts, bolts and washers etc. INCOMING : - (a) MCCB 63 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -01 No. with ICS=ICU=100%
(b) Multi function meter with LCD display, accuracy class 1.0, having parameters KW, KWh/ KVA, KVAh/ KVAr, KVArh & PF, duly prewired with suitable size of copper insulated FRLS wire including suitable size of CTs complete - 01 No. (c) Indicator with neon lamps for RYB, 3 Phase-01 set (d) Manually operated onload changeover switch of 63A , 415V AC, 4 pole - 01 No OUTGOING:- (a) MCB TPN 40Amp, 415 V, 16 KA-04 Nos.
M/S RAJESH CONSTRUCTION COMPANY
M/S Vinod Kumar
SANDEEP JHANJI CONSTRUCTIONS
G S TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .