Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC | L1 | Accepted-AOC BeingL1 | |
| 2 | L2₹12.9 L+₹27,182 (2.16%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹12.9 L+₹27,735 (2.20%)Rejected-Finance | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹13.3 L+₹67,810 (5.38%)Rejected-Finance | L4 | Rejected-Finance BEING NOT L1 | |
| 5 | L5₹13.7 L+₹1.1 L (8.96%)Rejected-Finance | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
22 Mar 2022, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
PROVN OF 100 KVA DG SET FOR LTS AT AIR FORCE STATION DEOLALI
2022_MES_510306_1
8853/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
DEOLALI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹28,000
Yes
22 Apr 2022
24 Feb 2022
24 Mar 2022
25 Feb 2022
22 Mar 2022
10 Mar 2022
Amount
Supply, installation, testing and commissioning of silent diesel engine driven ,factory assembled, floor mounted generating set with suitable Automatic on Mains failure control panel (AMF) suitable for out put, 100KVA, 415 volts, 3 phase, 4 wire, 50 HZ,1500 RPM Water Cooled complete with safety control and metering equipment mounted on & including common base frame on new PCC foundation as recommended by manufacturer all as specified and comprising of the following :- Prime Mover: Directly coupled diesel engine with blower fan, suitably matching 80 KW under NTP condition of BS:5514 for driving 100 KVA capacity, alternator electric start, four stroke confirming to latest IS-10001/10002 Part -II 19801 for continuous running and capable for taking 10% over load for 1 hours in every 12 hours complete with following accessories :- (i) Engine (Turbocharged with water cooling) (ii) Fly wheel to suitable coupling with guard (iii) Air cleaner with filters (Dry type, Replaceable paper element air cleaner with restriction indicator,(iv) Spin on filters-fuel, lube oil filter ,(v) Lubricating oil gauge. (vi) Anti- vibration pad as recommended by manufacturers (vii) PT pump with governor of suitable capacity & flywheel housing and flywheel to suit single bearing alternator (viii) Electric starters-self starter 12 Volt DC (ix) 12 volts, as per OEM recomendation battery supplied along with the in charged condition along with flexible copper battery lead and connector & Battery charging alternator(x) Standard safety devices. (xi) Daily services fuel tank ( as per OEM recomendation , Tank complete with level indicator, fuel inlet and outlet, air vent , drain plug including arrangement for direct filling ) for full running capacity of DG set for min 08 hours enclosed within the canopy all as per CPCB with level indicator, fuel outlet drain pug, air vent and locking .
(xii) Exhaust system shall be provided with thermal insulation by using fire retardant / non igniting foam confirming to BS-4735 to prevent excess heat radiation on the engine and sage for operator, Critical grade silencer suitable optimized to meet stringent sound emission standards laid down by MOEF/CPCB, Stainless steel exhaust flexible bellows to meet emission norms & Exhaust system shall not be based on (Exhaust Gas regeneration) i.e. EGR (a) Integrated DG set controller (DG set should have a microprocessor based controller with LCD display for engine and alternator parameter) Integrated Electronic Control Panel (displaying the following Engine parameters): (1) Engine Metering: Oil pressure, Engine temperature, starting battery voltage, Engine running hours. (2) AC Alternator Metering : L-L Voltage and L-N Voltage, (3) Current (phase and total), KVA (phase and total), Frequency, (4) Engine Protection : Low lube oil pressure, Battery Over/under/Weak Volts, Fail to Crank/Start, Sensor failure, cranking lockout MODBUS interface (RS 485 RTU) (5) AC Alternator Protection : Over/Under Voltage, Over/Under Frequency, Loss of AC sensing. (6) Safety Control (Trip & Indication) (7) High water temperature (hwt) (8) low lube oil pressure (llop) (9) Battery Over/Under/Weak Volts. (10) Failed to start, over crank lockout stop pressed. (b) Alternator: 100 KVA / 80 KW at 0.8 power factor, self regulated 3 phase with neutral 415 volts 50 Hz 1500 RPM with brushless excitation, Band of Voltage regulation + 1% of rated voltage, from no load to full load, Insulation Class "H" The alternator generally confirms to BS EN : 60034-1 / IS:4722. (C) Repair/Maint tools to be supplied with DG set are as under :-i) STANLEY 91-931-12-Master Tool set-120 Pieces of Make : STANLEY (ii) Cutting pliers 10 " - 01 No (d) ACOUSTIC ENCLOSURE : Floor Mounted Acoustic Enclosure suitable for 100 KVA DG Set as per CPCB Norms of Make: Kirloskar KOEL Green or equivalent in Cummins/ Crompton Greaves/ Mahindra Note: PCC concrete Type B1 1:2:4 using 20 mm graded stone aggregate cement concrete foundation will be measured and paid separately under respective item of schedule.
Supply and fix in repairs and laying in repairs LT XLPE insulated PVC heavy duty armoured cable 1100 volts grade multi stranded aluminium conductor electric cable cross sectional area 70 Sqmm 3.5 Core including necessary connection with provision of lugs & cable gland fixing arrangements complete all as specified and directed.
Excavation in trenches n. exc 1.5 Mtr wide and n. exc 1.5 mtr in depth and getting out soft/loose type soil complete all as specified and directed.
All as per item No.3 here in before but in hard/dense soil complete all as directed.
Returning Filling in including spreading, leveling, watering & well ramming in layers n. exc 25 Cm complete all as directed..
Removing excavated/Surplus soil n exc 50 Mtr & depositing where directed at a level n. exc 1.5 Mtr above the starting point complete all as directed..
Material & labour for fixing of DWC pipes it should be flexible & should allow deformation in diameter as well as in joints under external load & soil natural movement , socket & spigot joint with elastometric sealing ring, it should be highly corrosive resistant & it should be impact resistant, chemical resistant, flexible, light weight & it should have hih flow capacity of 50/38 mm outer and inner dia complete with coupler, elbows, joints and necessary joints required for completion of work all as specified & as directed by the Enguneer-in-charge.
All as per item No.8 here in before but of size 110/94 mm .
Surface dressing n exc 15 cm deep in loose/soft soil
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
Removing excated material exc 500 m & n exc 1.50 Km & depositing where as directed
Material & labour for Moorum / red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
Material & labour for soling (or sub-base) 200 mm spread thickness of broken or quarried stone, interstices filled, surface formed & rolled & consolidated to required gradient & camber.
Material & labour for hard core of gauge exc 63mm but not exc 100mm depositing, spread and levelled in layers n exc 15cm thick, watered and rolled/ rammed to a true surface.
Material & labour for Formwork to flat rough fnished concrete surfaces foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter.
Material & labour for 75mm thick Cement concrete type D2-1, 1:4:8 (40mm graded aggregate) as in sub base.
Material & labour for for Cement concrete type B- 1,1:2:4 (20 mm graded aggregate) 150 mm thick as bed plates, plinth courses , lacing courses, stings etc..
Material & labour for 15 mm thick plastering on concrete surface or faces of brick work in CM (1:6)
Datar Electrical and Engg Services
E M CONSTROL SYSTEM
SURAJ ELECTRICAL AND ENGINEERS
YASHRAJ ELECTRICALS
Shree Sai Samarth Enterprises
MONA GENERATOR SEVICES PVT. LTD.
M/s.TIRUPATI BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .