Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹27.9 L+₹4.1 L (17.4%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹28.0 L+₹4.2 L (17.8%)Rejected-Finance 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹29.4 L+₹5.7 L (24.0%)Rejected-Finance | L4 | Rejected-Finance Not Lowest |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
3 Oct 2024, 6:00 pmClosed
GE NORTH BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINESMEG AND CENTRE BANGALORE 560042
REPAIR REPLACEMENT OF INTERNAL WIRING ELECTRICAL FITTINGS FIXTURES RENEWAL OF BLDG EARTHING CEILING FANS EXHAUST FANS GEYSERS SPIT WINDOW TYPE AIR CONDITIONERS WATER COOLERS DEEP FREEZER AND ALLIED WORKS IN RO MD OTM ACCNS AT AFSOD
2024_MES_672294_1
8201
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
BANGALORE
Class D Category b(i)
7 documents required · 7 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹68,000
Yes
18 Nov 2024
5 Sept 2024
10 Oct 2024
5 Sept 2024
3 Oct 2024
19 Sept 2024
5 Sept 2024 - 19 Sept 2024
Amount
Taking down carefully aluminium / copper wiring / power point wiring (light, fan, call bell socket or power circuits) complete and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concealed in walls incl MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following One light point controlled by one switch
All as per item No. 2 above but for One fan point controlled by one switch / regulator
All as per item No. 2 above but for One light point controlled by 2 way switch
All as per item No. 2 above but for One 3 pin socket out let 5 Amps on independent board
All as per item No. 2 above but for One bell / buzzer point controlled by bell push
All as per item No. 2 above but for One 3 pin socket out let 5 A on same board
Poinrt wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concelaed type wiring incl GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following One light point controlled by one switch
All as per item No. 8 above but for One fan point controlled by one switch / regulator
All as per item No. 8 above but for One light point controlled by 2 way switch
All as per item No. 8 above but for One 3 pin socket out let 5 Amps on independent board
All as per item No. 8 above but for One bell / buzzer point controlled by bell push
All as per item No. 8 above but for One 3 pin socket out let 5 A on same board
All as per item No 2 but concealed wiring drawn through existing PVC conduit. One light point controlled by one switch
All as per item No. 14 above but for One fan / Exhaust point controlled by one switch / regulator
All as per item No. 14 above but for One light point controlled by 2 way switch
All as per item No. 14 above but for One 3 pin socket out let 5 Amps on independent board
All as per item No. 14 above but for One bell/buzzer point controlled by bell push
All as per item No. 14 above but for One 3 pin socket out let 5 A on same board
Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through non-metalic existing PVC conduit medium density ISI marked incl accessories surface type run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing non metallic rigid PVC conduit and conduit accessories all as specified and as directed. Note:- 3 runs of cable will be measured as unit length for payment.
Point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC Casing & Caping ISI marked incl accessories surface type wiring incl 1.6 mm thick MS sunken boxes concealed on walls including laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following One light point controlled by one switch
All as per item No. 22 above but for One fan point controlled by one switch / regulator
All as per item No. 22 above but for One light point controlled by 2 way switch
All as per item No. 22 above but for One 3 pin socket out let 5 Amps on independent board
All as per item No. 22 above but for One bell/buzzer point controlled by bell push
All as per item No. 22 above but for One 3 pin socket out let 5 A on same board
Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic PVC conduit medium density ISI marked incl accessories concealed type Modular/normal run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC casing caping ISI marked incl incl accessories surface type wiring run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. Note for Item No 2 to 29 :- (i) The earth wire for the points in the same circuit can be looped from point to point (ii) Earth wire shall be taken inside the conduit (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. (v) cost of cutting chases for concealed wiring is included in quoted rate.
S&F in replacement of LED batten suitable for indoor applications 20 Watts,4 feet with extruded aluminium housing & integrated LED channel complete with all accessories including taking out old fittings all as specified and directed. Make: Bajaj, Cat No.BCLAB 20 W LED P or equivalent Makes & model
S&F in replacement of LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as specified and directed. Make: Bajaj, Cat No.BCLSB 10 W WH or equivalent Makes & model
S&F in replacement of 2' x 2' Recess mounted LED Luminaire 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. Make: Bajaj, Cat No : BZRSQL 36L LED GX WH or equivalent Makes & model
S&F in replacement of 1' x 1' Surface mounted LED Luminaire 24 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. Make: Bajaj, Cat No : BZSSQL 24W LED WHI or equivalent
S&F in replacement of Bulkhead LED luminaries 10 watt energy efficient solution for upgrading convertional with IP 65 ncluding taking out old fittings as specified and directed. Make: Bajaj, Cat No : BIBWP10WLED or equivalent
Supply and Fix in replacement of Modular switch 1 way 6A,1 module
Supply and fix in replacement of Modular switch 1 way 16A, 1 module
Supply and fix in replacement of Modular switch 2 way 6A,1 module
Supply and Fix in replacement of Modular Bell push 6A 1 module
Supply and fix in replacement of modular Socket, 6A - 2/3 pin combined 2 module
Supply and fix in replacement of modular Socket 6A/16A - 2/3 pin combined 2 module,
Supply and fix in replacement of modular type Fan step regulator, 120W - 2 module
S&F in replacement of Switch piano flush button single pole two way 5 Amps all as specified and as directed.
S&F in replacement of Angle holder PVC/polycarbonate type all as specified and as directed
S&F in replacement of switch piano flush type single pole one way 5 Amps
S&F in replacement of switch socket combination 5 pin 2 in 1, 5 A Flush type all as specified and as directed
S&F in replacement of switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and as directed
S&F in replacement of socket outlet 2 in 1, 3 pin 5 A all as specified and as directed
S&F in replacement of bell push flush type 5A all as specified and as directed .
S&F in replacement of MCB SPN 240 volts 32/40 Amps complete all as specified and as directed
S&F in replacement of MCB single pole 240 volts 10 to 32 Amps complete all as specified and as directed
S&F in replacement of MCB TPN 415 volts, 10KA 'C' curve 63 Amps complete all as specified and as directed
S&F in replacement of MCB TPN 415 volts, 10KA 'C' curve 100 Amps complete all as specified and as directed
Taking down unserviceable sheet metal enclosure/ DB, supply and fix, MCB DB SPN 4 way (Horizontal), double door with Sheet metal enclosure, flush mounted, prewired, 240 V, AC, 50 Hz, Factory made, powder coated, IP-42 protection conforming to IS-13032 universal mounting with 200 Amps rated copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, etc complete all as specified and as directed. Notes : i) All unused modules shall be provided with blanking plate for which the cost is deemed to be included in the cost of MCB DBs. ii) MCB/ Isolators will be measured and paid separately as supply and fix under respective items.
All as per Serial Item No 53 here-in-above, but SPN 8 ways
All as per Serial Item No 53 here-in-above, but TPN 4 ways, 415 V
S&F in replacement of ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
S&F in replacement of stepped type electronic fan regulator flush Switch/socket type all as specified and as directed
S&F in replacement of Ding Dong bell AC 230 volts single pole.
Provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit including removing old unsv submain complete all as specified and as directed. Note: 3 runs of cable and one run of conduit will be measured as unit length for payment.
Provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit including removing old unsv submain complete all as specified and as directed. Note: 3 runs of cable and one run of conduit will be measured as unit length for payment.
Provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 2.5 Sqmm along with 2.5 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit including removing old unsv submain complete for power point all as specified and as directed. Note: 3 runs of cable and one run of conduit will be measured as unit length for payment.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed.
S&F LED lamp suitable to fit in angle holder of capacity 09 watt. Make: Bajaj or eqv in Philips/Havells/CG.
Supply and fixing 30 W LED bldg security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection including taking out old fittings. Make:- Bajaj, Cat No.:- ENXT P 30L WH SY PC SD or Equivalent Makes & model
S&F Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer including removing the old existing GI bracket from bldg complete all as specified and directed.
S&F in replacement PVC Fresh air fan of 200mm sweep 1200/1400 RPM with louver. Make CG/Usha/ Orient/Phillips/Bajaj.
S&F in replacement of Single pole & neutral enclosure 20 Amps & 240 V with two pin and earth plug and socket complete with one single pole MCB 20 Amps.
Inspection, taking down, dismantling of geysers of any type/capacity, cleaning, descaling, reassembling & reinstallation on the old place incl hydraulic pressure test of container with hand operated hydraulic pump complete, brazing inner tank, internal wiring and reinstallation after necessary repair / replacement of old parts all as specified & as directed. Note : Replacement of old parts shall be measured & paid separately.
Supply only stainless/Mild steel inner tank of capacity 25 ltrs unit including internally assembly of any size and type complete all as specified & as directed.
Supply only internal assembly/apparatus rod unit of any size and type of capacity 25 ltrs complete all as specified & as directed.
Supply only heating element of 2 KW rating triangular/round type as per existing size and type including rubber washers all as specified & as directed.
Supply only heating element of 2 KW rating Hexagonal spiral/bend type as per existing size and type including rubber washers all as specified & as directed.
Supply only Thermostat/auto cut off of suitable size and type for 25/50 Ltrs capacity of any size.
Supply only Indicator lamp red and green type square/round.
Supply only Safety valve/high pressure valve / NRV of exisiting type ISI marked.
Supply only PVC insulated Copper cable flexible 3 core of size 40/0.0076 ISI marked.
Supply only outer cover of geyger for capacity 25 ltrs unit complete with all fitting and fixtures as specified & as directed.
Supply only outer cover of geyger for capacity 50 ltrs unit complete with all fitting and fixtures as specified & as directed.
Supply only stainless/Mild steel inner tank of capacity 50 ltrs unit complete with all fitting and fixtures all as specified & as directed.
Supply only internal assembly/apparatus rod unit of any size and type of capacity 50 ltrs complete all as specified & as directed.
S&F in replacement of Thermostat/auto cut off of suitable size and type for 25/50 Ltrs capacity of any size.
S&F in replacement of heating element of 2 KW rating triangular/round type as per existing size and type including rubber washers all as specified & as directed.
S&F in replacement of heating element of 2 KW rating Hexagonal spiral/bend type as per existing size and type including rubber washers all as specified & as directed.
S&F in replacement of PVC flexible pipe 16 mm dia 450mm long with 2 Nos of brass ferrule & rubber washer for hot and cold water all as specified & as directed. (Set of 2)
M&L for Preparation old painted surface & painting the geyser complete after cleaning & applying one coat of spray paint of white enamel, writing MES No incluing taking down and refixing in same or other place complete all as specified & as directed by Engr -in-Charge.
Taking down ceiling fan 1200mm/1400mm and wall mounted fan 300/450 mm sweep from position by duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin, rubber pully etc., including refixing and connecting the same complete all as specified and as directed.
Inspection, disconnecting electric connecting and dismantling of ceiling fan/exhaust/wall mounted fan of any type/size, cleaning including oiling and greasing the bearing, tighting of nuts and bolts and refixing on the old place complete after necessary repair / replacement of old parts all as specified & as directed. Note : Replacement of old parts shall be measured & paid separately.
Supply only ball bearing of various sizes / make as required for ceiling fans/wall mounting / exhaust fan including greasing complete all as specified and as directed.
Supply only Gun metal bush of any size/make suitable for ceiling fans all as specified and as directed.
Supply only capacitor 2.5 Mfd suitable for ceiling / exhaust /wall mounting fans complete all as specified and as directed.
Supply only capacitor 4.0 Mfd suitable for ceiling / exhaust/wall mounting fans complete all as specified and as directed.
PVC flexible cable twin twisted core of 23/0.0076 size multi stranded copper conductor suitable for connecting ceiling fans / exhaust / wall mounting fans complete all as specified and as directed.
Rubber bush with MS bolts, nuts & washers with 'U' clamps for ceiling fans complete all as specified and as directed.
Supply only motor rotar ring for ceiling fans complete all as specified and as directed.
Supply only motor stator for ceiling fans complete all as specified and as directed.
Supply only down rod of 30/45 cm with nut, bolts and safety pin for ceiling fans complete all as specified and as directed.
Supply only plastic cup with screw for ceiling fans complete all as specified and as directed.
S&F in repair of exhaust fans motor upto 300/230 mm sweep, heavy duty, 1400 RPM, AC single phase 230/240 V with blades complete all as specified and directed. Make : Bajaj / CG / Havells / Khatian or Equivalent make.
S&F in repair of exhaust fans outerframe for holding exhaust fan motor upto 280 mm sweep with supporting angle complete all as specified and directed. Make : Bajaj / CG / Havells / Khatian or Equivalent make.
S&F in repair of exhaust fans outerframe for holding exhaust fan motor upto 300/230 mm sweep with supporting angle complete all as specified and directed. Make : Bajaj / CG / Havells / Khatian or Equivalent make.
M&L in repair louver of exhaust fan suitable for 300/230 mm sweep complete accessories all as specified and directed
M&L in repair louver of exhaust fan suitable for 450 mm sweep complete accessories all as specified and directed
Dismantling /opening the ceiling fan of 1200 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling/re-fixing in its location complete all as specified and as directed.
Dismantling /opening the ceiling fan of 1400 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
Dismantling /opening the wall mounted fan of 300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
Taking down exhaust fans 230 mm/300mm / 450mm sweep from position by duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin, rubber pully etc., including refixing and connecting the same complete all as specified and as directed.
Dismantling /opening the exhaust fan of 230 mm/300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
M&L extension of down rod for ceiling fan upto 1.5 mtr including nut, bolts , washers complete accessories all as specified and as directed.
Removing the window type AC/Split type AC of 1.0/1.5/2.0 ton capacity from location servicing the AC, cleaning the condenser and evaporator coil by blower, checking the electrical wiring, repalcement of burnt out wiring terminals, cleaning the air filter, adjusting relays etc., replacement of unserviceable spare parts and fixing back at location, testing and commissioning complete all as directed.
Removing the split type AC of any make from position transporting to a reputed workshop, cutting the suction and discharge line of unserviceable compressor and replace with new factory made hermatically sealed compressor of same make and type, connecting the suction and discharge line, vacuuming the entire system, arresting all leakages, charging of required quantity of refrigerant, adjusting relays, thermostat etc bringing back and installing in its original position incl testing and commissioning complete all as directed for the following capacities:- 1.5 ton capacity
All as per item No. 110 above but for 2.0 ton capacity Note for item No 109 to 111 :- (i) Gas will be measured and paid separately for item No 109 to 111 under relevent item of this schedule. (ii) Spares costing more than 200 Rs will be measured and paid seperately under relevent item of this schedule. (iii) Quoted rate includes for transporation if reqiured.
Labour only for opening split / window type AC including leak detection by using nitrogen gas and arresting leakages if any by necessary brazing and flushing the system complete and testing complete for the following capacities: 1.5 Ton
All as per item No. 112 above but for 2.0 Ton
Removing the damaged/unserviceable fan blades from the condenser motor shaft and replace new fan blade of the same size and type for any capacity of window type AC and water coolers all as specified and directed.
Removing the unserviceable thermostat and Supply and fix new thermostat of same make and type for Split/window type AC 1.5/2 ton capacity. (Make- Indfos/Danfoss)
Removing the unserviceable condenser unit & supply & fix new condenser unit connecting to the discharge line, brazing, vaccumising & gas charging the unit with required quantity of refrigerant for Split/window type AC of 1.5/2 Ton capacity and testing complete all as directed.
Removing the unservicable running capacitor of 40 MFD, Supply and fix of new capacitor suitable for 1.5 ton AC make :- BHEL / EPCOS/ TDK/ TIBCON or equivalent.
All as per item No. 117 above but for Starting capacitor of 80/100 MFD for 1.5 TR/2 TR AC.
Removing the unservicable over load protection and Supply and fix new over load protector for split/window type AC of 1.5/2.0 TR capacity.
Supply and fill refrigrent gas (R-22/410A/134A) for domestic cooling appliance.
Disconnecting and taking out the unservicable sensor/remote unit completely and supply and fix new sensor unit of indoor unit of AC to suit the AC of Makes carrier / Bluestar / Voltas 1.5 Ton Split type AC
All as per item No. 121 above but for 2 Ton Split type AC
Disconnecting and taking out the unservicable PCB, refixing new PCB for split AC / window AC any type and any make all as directed. 1.5 Ton Split type AC
All as per item No. 123 above but for 2 Ton Split type AC
Disconnecting and taking out PCB circuit of disconnecting out PCB from split AC, repairing the same and refixing in original location complete all as specified and directed for 1.5/2 Ton capacity all as directed.
Disconnect electrical connection, removing copper line, discharge line of split type AC upto 2 Ton capacity including indoor and out door units and all accessories and shifting/ reinstalling and testing the whole unit of split type AC in new location with suitable size and length of copper pipe and making the holes in walls complete all as specified.
Supply and fix plastic/coir filter suitable for Split/window type AC 1.5/2 Ton capacity including taking down old unsv filter etc complete all as specified and as directed.
S&F in replacement of brass angle valve for gas charging for split AC 1.5/2 ton of AC compete all as specified and as directed.
S&F in replacement of swing motor of existing capacity and type for indoor unit of split AC fins complete all as specified and as directed
S&F in replacement of MS fabrication clamps for hanging, fan including hook as existing complete all as specified and as directed
S&F in replacement of Nitrile rubber insulation for suction and dischaged pipe of split type AC of size 15/19 mm dia complete all as specified and as directed.
S&F in replacement of Soft copper tubing 15mm dia with nitrile rubber insulation for split type AC complete all as specified and as directed.
S&F in replacement of Soft copper tubing 19mm dia with nitrile rubber insulation for split type AC complete all as specified and as directed.
S&F in replacement of Switch 32 Amps flush type with indication lamp all as specified and as directed
S&F in replacement of switch socket combination 2 in 1, 3 pin 5 and 32 Amps flush type universal with indication lamp all as specified and as directed.
Supply and fix refrigerators, electric driven (single phase), capacity 310 Litres. BEE 5 star rated. Make : LG/Whilpool/IFB.
Supply and fix voltage stabilizer suitable for water cooler complete all as specified and as directed. Make : V Guard / Everest / Sinotech 1 KVA
All as per item No. 137 above but for AC 1.5 Ton 4 KVA
All as per item No. 137 above but for AC 2 Ton 5 KVA
Supply and install hi wall split units indoor / outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TON complete all as specified and as directed. Make - Blue Star/Voltas/LG.
S&F ceiling fans complete with complete accessories, 230V, SP 1200 mm Sweep with BEE 3 star rating complete with all accessories and fixing the fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as specified and as directed Make :- Havells/CG/ Bajaj.
S&F Exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louvers fixed outside with all accessories and fixing the exhaust fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as directed. Make : Bajaj cat No : 70046, MAXX AIR 300 mm or eqv in Make Havells/CGs/ Orient
S&F in replacement PVC Fresh air fan of 150 mm sweep 1200/1400 RPM with louver. Make CG/Usha/ Orient/Phillips/Bajaj.
GS TRADERS (BID ID -3114332)
Vasavi Electricals (BID ID -3116080)
RAMSON TRADERS (BID ID -3127247)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .